Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Monitoring Surface Condition of Plasma Grid of a Negative Hydrogen Ion Source

Surface condition of a plasma grid in a negative hydrogen ion source is controlled so as to maximize the beam current under a discharge operation with introducing Cs into the ion source. Photoelectric current induced by laser beams incident on the plasma grid can produce a signal to monitor the surface condition, but the signal detection can be easily hindered by plasma noise. Reduction in size of a detection electrode embedded in the plasma grid can improve signal-to-noise ratio of the photoelectric current from the electrode. To evaluate the feasibility of monitoring surface condition of a plasma gird by utilizing photoelectric effect, a small experimental setup capable of determining quantum yields of a surface in a cesiated plasma environment is being assembled. Some preliminary test results of the apparatus utilizing oxide cathodes are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multivariate Empirical Mode Decomposition Based Signal Analysis and Efficient-Storage in Smart Grid

Wide-area-measurement systems (WAMSs) are used in smart grid systems to enable the efficient monitoring of grid dynamics. However, the overwhelming amount of data and the severe contamination from noise often impede the effective and efficient data analysis and storage of WAMS generated measurements. To solve this problem, we propose a novel framework that takes advantage of Multivariate Empirical Mode Decomposition (MEMD), a fully data-driven approach to analyzing non-stationary signals, dubbed MEMD based Signal Analysis (MSA). The frequency measurements are considered as a linear superposition of different oscillatory components and noise. The low-frequency components, corresponding to the long-term trend and inter-area oscillations, are grouped and compressed by MSA using the mean shift clustering algorithm. Whereas, higher-frequency components, mostly noise and potentially part of high-frequency inter-area oscillations, are analyzed using Hilbert spectral analysis and they are delineated by statistical behavior. By conducting experiments on both synthetic and real-world data, we show that the proposed framework can capture the characteristics, such as trends and inter-area oscillation, while reducing the data storage requirements

Big Data↗

Anomaly Detection Using Optimally-Placed μPMU Sensors in Distribution Grids

IEEE As the distribution grid moves toward a tightly-monitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. Here, focusing on Micro-Phasor Measurement Unit (μPMU) data, we propose a hierarchical architecture for monitoring the grid and establish a set of analytics and sensor fusion primitives for the detection of abnormal behavior in the control perimeter. And due to the key role of the μPMU devices in our architecture, a source-constrained optimal μPMU placement is also described that finds the best location of the devices with respect to our rules. The effectiveness of the proposed methods are tested through the synthetic and real μPMU data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electricity Supply Infrastructure Improvements: Final Technical Status Report, December 2010

This report is about a work effort where the overall objectives were to establish a methodology and approach for selected transmission and distribution (T&D) grid modernization; monitor the results; and report on the findings, recommendations, and lessons learned. The work reported addressed T&D problems and solutions, related reliability issues, equipment and operation upgrades, and respectivefield testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mobile electric field sensor based phasor measurement unit for monitoring an electric power grid

A system may include an electric field sensor, an analog to digital converter, and an estimator. The electric field sensor may measure electric fields of electric power grid. The analog to digital converter may generate digital output based upon measurements from the electric field sensor. The estimator may estimate phasor data of the electric power grid based upon the digital output.

Liu, Yilu↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Grid site availability evaluation and monitoring at CMS

The Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) uses distributed grid computing to store, process, and analyse the vast quantity of scientific data recorded every year. The computing resources are grouped into sites and organized in a tiered structure. Each site provides computing and storage to the CMS computing grid. Over a hundred sites worldwide contribute with resources from hundred to well over ten thousand computing cores and storage from tens of TBytes to tens of PBytes. In such a large computing setup scheduled and unscheduled outages occur continually and are not allowed to significantly impact data handling, processing, and analysis. Unscheduled capacity and performance reductions need to be detected promptly and corrected. CMS developed a sophisticated site evaluation and monitoring system for Run 1 of the LHC based on tools of the Worldwide LHC Computing Grid. For Run 2 of the LHC the site evaluation and monitoring system is being overhauled to enable faster detection/reaction to failures and a more dynamic handling of computing resources. Furthermore, enhancements to better distinguish site from central service issues and to make evaluations more transparent and informative to site support staff are planned.

43 PARTICLE ACCELERATORS↗

SEM Grid Testing at NLCTA in BeamNetUS Program

We report on the performance of a secondary electron monitor (SEM) grid used to measure the transverse profile of an MeV range electron beam at SLAC National Accelerator Laboratory’s Next Linear Collider Test Accelerator (NLCTA) facility. When inserted into the path of the electron beam, secondary electron emission results in a measurable current on the wires that make up the grid. We present measurements using this technique to reconstruct the beam profile. The SEM grid was designed and manufactured by a team of undergraduate students at Harvey Mudd College (HMC) and was tested at SLAC’s NLCTA facility in collaboration with NCLTA staff as part of the BeamNetUS program. Developed for real-time diagnostics of MeV-range electron beams, this SEM grid has potential applications in both industrial and medical contexts.

43 PARTICLE ACCELERATORS↗

Formulation of Three-Phase State Estimation Problem Using a Virtual Reference

State Estimation (SE) is the backbone of modern Energy Management System (EMS) due its capability of processing real time measurements and provide reliable information to system operators. Since its introduction to power systems in the 70’s, SE has been widely used in transmission networks. Distribution grids on the other hand lack sufficient number of real time measurements, and for that reason SE has not been widely implemented on these systems. The recent increase in the number of renewable energy sources connected to the grid at lower voltage levels, the advent of Distribution Automation (DA) and Smart Grids necessitate closer monitoring of distribution networks and thus forcing utilities to upgrade their operations and deploy Advanced Distribution Management Sytems (ADMS). Therefore, Distribution System State Estimation (DSE) is paramount to provide real time monitoring of active distribution grids. This papers investigates the formulation of the three-phase distribution state estimation where in the most general case, none of the system buses may have balanced three phase voltages. In such a case, the choice and definition of the slack bus need to be revisited. Most of the existing work arbitrarily assign the root bus of the distribution feeder as the balanced three-phase reference which may not be realistic for today’s active distribution systems. This paper addresses this shortcoming of the existing SE formulations by introducing a virtual reference bus. Here, the proposed approach is effectively validated by simulations carried out on distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A System for Monitoring and Management of Computational Grids

As organizations begin to deploy large computational grids, it has become apparent that systems for observation and control of the resources, services, and applications that make up such grids are needed. Administrators must observe the operation of resources and services to ensure that they are operating correctly and they must control the resources and services to ensure that their operation meets the needs of users. Users are also interested in the operation of resources and services so that they can choose the most appropriate ones to use. In this paper we describe a prototype system to monitor and manage computational grids and describe the general software framework for control and observation in distributed environments that it is based on.

Smith, Warren↗

Fiber optic sensors for monitoring sodium circuits and power grid cables

At Kalpakkam, India, a programme on development of Raman Distributed Temperature sensor (RDTS) for Fast Breeder Reactors (FBR) application is undertaken. Leak detection in sodium circuits of FBR is critical for the safety and performance of the reactors. It is demonstrated that RDTS can be usefully employed in monitoring sodium circuits and in tracking the percolating sodium in case of any leak. Aluminum Conductor Steel Reinforced (ACSR) cable is commonly used as overhead power transmission cable in power grid. A second application demonstrates the suitability of using RDTS to monitor this transmission cable for any defect. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report - "UCM-Grid Service for User-Centric Monitoring"

The User Centric Monitoring (UCM) project was aimed at developing a toolkit that provides the Virtual Organization (VO) with tools to build systems that serve a rich set of intuitive job and application monitoring information to the VO's scientists so that they can be more productive. The tools help collect and serve the status and error information through a Web interface. The proposed UCM toolkit is composed of a set of library functions, a database schema, and a Web portal that will collect and filter available job monitoring information from various resources and present it to users in a user-centric view rather than and administrative-centric point of view.

97 MATHEMATICS AND COMPUTING↗

Robust Real-Time Modeling of Distribution Systems with Data-Driven Grid-Wise Observability (Final Technical Report)

The overall objective of this project is to leverage existing and emerging sensor measurements to develop data-driven observability enhancement algorithms as well as robust state estimation and parameter identification techniques to enable real-time grid-wise monitoring and modeling of loads and distributed energy resources (DERs). The project resulted in a holistic framework with the following key components: 1) data-driven and machine learning-based grid-edge visibility enhancement, 2) robust branch-current-based state estimation (BCSE), and 3) robust real-time steady-state and dynamic-state modeling of loads and DERs. The research outcomes have provided utility companies better network visibility, higher-fidelity load/DER models, and more accurate assessment of DERs’ impacts, thus, facilitating the integration of renewable energy sources. The synergistic collaborative project among Iowa State University (ISU), Argonne National Laboratory (ANL), Electric Power Research Center (EPRC), SIEMENS Industry, Alliant Energy, Cedar Falls Utilities (CFU), and Maquoketa Valley Electric Cooperative (MVEC) to leverage the team’s extensive expertise and experience in power distribution systems, state estimation, online modeling and identification, and DER integrations. The proposed frameworks have been verified with industry adopted software and attempted integrated with existing tool wherever possible

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time Condition Monitoring of Power Modules in Grid-tied Power Converter

This paper proposes and demonstrates a real-time condition monitoring method using gate driver integrated sensing circuits and sensor fusion algorithms. Power device on-state voltage (VDSon) measurement and junction temperature (Tj) sensing circuits with high noise immunity are built and integrated into an adaptive gate driver circuit for power modules. Considering the inherently noisy measurement environment of power converters, VDSon together with several other measurements are fused together to provide accurate descriptions of the stress and degradation of each power device. Furthermore, the gate driver circuit can actively control the turn-on gate voltage (VGSon) for each device based on the stress and degradation state. The proposed sensing circuits and power device condition assessment algorithms are implemented in a 75 KVA grid-tied power converter. This paper focuses on the sensing circuits hardware designs and testing in grid-tied power converter prototype and device stress index generation. More comprehensive results on the device state of health index generation will be presented in future work.

Fan, Junchong↗

Cyber-Physical Attack-Resilient Wide-Area Monitoring, Protection, and Control for the Power Grid

Cyber security and resiliency of Wide-Area Monitoring, Protection and Control (WAMPAC) applications is critically important to ensure secure, reliable, and economic operation of the bulk power system. WAMPAC relies heavily on the security of measurements and control commands transmitted over wide-area communication networks for real-time operational, protection, and control functions. Also, the current “N-1 security criteria” for grid operation is inadequate to address malicious cyber events and therefore it is important to fundamentally redesign WAMPAC and to enhance Energy Management System (EMS) applications to make them attack-resilient. In this paper, we propose an end-to-end defense-in-depth architecture for attack-resilient WAMPAC that addresses resilience at both the infrastructure layer and the application layers. Also, we propose an attack-resilient cyber-physical security framework that encompasses the entire security life cycle including risk assessment, attack prevention, attack detection, attack mitigation, and attack resilience. The overarching objective of this paper is to provide a broad scope that comprehensively describes most of the major research issues and potential solutions in the context of cyber-physical security of WAMPAC for the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atmospheric tracer monitoring and surface plume development at the ZERT pilot test in Bozeman, Montana, USA

A controlled release of CO 2 was conducted at a field site in Bozeman, Montana, USA in July of 2008 in a multi-laboratory study of near surface transport and detection technologies. The development of a subsurface CO 2 plume near the middle packer section of the horizontal release was studied using soil-gas and surface flux measurements of CO 2 . A perfluorocarbon tracer was added to the CO 2 released from this section of the horizontal well, and the development of atmospheric plumes of the tracer was studied under various meteorological conditions using horizontal and vertical grids of monitors containing sorbent material to collect the tracer. This study demonstrated the feasibility of using remote sensing for the ultra low level detection of atmospheric plumes of tracers as means to monitor the near surface leakage of sequestered CO 2 .

54 ENVIRONMENTAL SCIENCES↗