Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid supporting function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Anti-Islanding with Advanced Grid Support in Single- and Multi-Inverter Islands

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1. In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2. The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness.

14 SOLAR ENERGY↗

Hawaiian Electric Advanced Inverter Test Plan - Result Summary

This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the converters combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.

14 SOLAR ENERGY↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Final Report Report: Smart Grid Ready PV Inverters with Utility Communication

In 2011, EPRI began a four-year effort under the Department of Energy (DOE) SunShot Initiative Solar Energy Grid Integration Systems - Advanced Concepts (SEGIS-AC) to demonstrate smart grid ready inverters with utility communication. The objective of the project was to successfully implement and demonstrate effective utilization of inverters with grid support functionality to capture the full value of distributed photovoltaic (PV). The project leveraged ongoing investments and expanded PV inverter capabilities, to enable grid operators to better utilize these grid assets. Developing and implementing key elements of PV inverter grid support capabilities will increase the distribution system’s capacity for higher penetration levels of PV, while reducing the cost. The project team included EPRI, Yaskawa-Solectria Solar, Spirae, BPL Global, DTE Energy, National Grid, Pepco, EDD, NPPT and NREL. The project was divided into three phases: development, deployment, and demonstration. Within each phase, the key areas included: head-end communications for Distributed Energy Resources (DER) at the utility operations center; methods for coordinating DER with existing distribution equipment; back-end PV plant master controller; and inverters with smart-grid functionality. Four demonstration sites were chosen in three regions of the United States with different types of utility operating systems and implementations of utility-scale PV inverters. This report summarizes the project and findings from field demonstration at three utility sites.

14 SOLAR ENERGY↗

Voltage Regulation with Customer-Sited Resources

This presentation provides a high-level overview of the simulation of feeder operations with advanced inverter grid support functions to understand operational and customer curtailment impacts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Evaluation of a Secure Virtual Power Plant.

For three years, Sandia National Laboratories, Georgia Institute of Technology, and University of Illinois at Urbana-Champaign investigated a smart grid vision in which renewable-centric Virtual Power Plants (VPPs) provided ancillary services with interoperable distributed energy resources (DER). This team researched, designed, built, and evaluated real-time VPP designs incorporating DER forecasting, stochastic optimization, controls, and cyber security to construct a system capable of delivering reliable ancillary services, which have been traditionally provided by large power plants or other dedicated equipment. VPPs have become possible through an evolving landscape of state and national interconnection standards, which now require DER to include grid-support functionality and communications capabilities. This makes it possible for third party aggregators to provide a range of critical grid services such as voltage regulation, frequency regulation, and contingency reserves to grid operators. This paradigm (a) enables renewable energy, demand response, and energy storage to participate in grid operations and provide grid services, (b) improves grid reliability by providing additional operating reserves for utilities, independent system operators (ISOs), and regional transmission organization (RTOs), and (c) removes renewable energy high-penetration barriers by providing services with photovoltaics and wind resources that traditionally were the jobs of thermal generators. Therefore, it is believed VPP deployment will have far-reaching positive consequences for grid operations and may provide a robust pathway to high penetrations of renewables on US power systems. In this report, we design VPPs to provide a range of grid-support services and demonstrate one VPP which simultaneously provides bulk-system energy and ancillary reserves.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Scale Shared Energy Storage Deployment: Challenges, Research Gaps, and Opportunities

Although community energy storage (CES) and behind-the-meter (BTM) energy storage systems have been widely used to offer homeowners and communities a variety of localized benefits, their scalability and grid support functionalities are limited. On the other hand, utility-scale shared energy storage (USES) systems may offer a number of benefits for grid integration, scalability, and economic viability. When compared to BTM and CES alternatives, these large-scale systems provide more storage capacity, more efficient operations, and more economically viable options. The deployment of USES presents opportunities for optimizing grid performance, integrating renewable energy resources, and improving energy security at the community level. However, significant research gaps exist in optimizing the integration and operation of these systems, especially to allocate energy for consumer use, grid services, and enhancing energy resilience. This paper reviews the literature in this regard, focusing on the opportunities, research gaps, and challenges associated with USES deployment. Firstly, the paper provides an overview of USES systems and emphasizes their benefits. Secondly, the key challenges are identified, and research gaps associated with the operation and integration of these systems are highlighted. Lastly, some potential solutions and opportunities that can be adopted to facilitate the rapid deployment and management of USES are presented. Technological, economic, regulatory, and environmental aspects are also discussed in this paper, providing an overview of the current state and future prospects of this technology.

Gautam, Mukesh [BATTELLE (PACIFIC NW LAB)] (ORCID:↗

Experimentation in Exploring Photovoltaic Inverter Dynamics Under Different Irradiance Levels Through a Data-Driven Approach

As conventional direct connections of synchronous generators are being phased out, inverter-based resources (IBRs) with grid support functions are increasingly being integrated into power systems. This transition requires the development of accurate dynamic models for IBRs to predict how power systems will adapt to varying levels of IBRs penetration, establish grid code requirements, and ensure compliance. Here, this study introduces an active probing signal-based data-driven modeling technique to accurately derive the dynamics model of a smart photovoltaic inverter operating in Volt-Watt and Freq-Watt modes, in compliance with the IEEE 1547–2018 standard. The paper focuses on investigating how the dynamics of the PV inverter model respond to fluctuations in solar irradiance, utilizing real-time digital simulator experimentation. The experimental analysis demonstrates that the amplitude of dynamics fluctuates with changes in irradiance across both operational modes and confirms the active power’s dependence on irradiance levels. Furthermore, the nature of inverter dynamics varies distinctly between the different modes of activation. Critically, our findings indicate that dynamic models require DC-gain adjustments to accommodate contrasting irradiance levels, highlighting a negative gradient linear relationship between the DC-gain of each model and the irradiance.

14 SOLAR ENERGY↗

Grid-Forming Wind: Getting Ready for Prime Time With and Without Inverters

Variable wind power is one of the fastest-growing energy-generation technologies, harnessing the energy of wind, both on land and at sea. During the past decade, the global share of wind power has grown tremendously, and wind power is evolving into a major contributor to electricity supplies in many countries. In this journey, wind is also becoming a source of reliability services to the grid, which has required grid-supporting functions originally provided by synchronous generators, enabling very high levels of instantaneous penetration (ranging from 60 to 70% in some power systems). To get beyond this, a fundamental shift is required to address challenges associated with the transition to a grid with only a few remaining (or even without any) conventional synchronous generators while achieving a minimum acceptable level of stability.

energy consumption↗

Proactive Intrusion Detection and Mitigation System

SAND2023-05661O The proactive intrusion detection and mitigation system (PIDMS) provides grid-edge situational awareness for cybersecurity defense by capturing real-time distributed energy resource (DER) network traffic and performance data with a novel approach that improves the detection and prevention of cyber-physical attacks. The PIDMS addresses the grid-edge security gap with real-time analysis of both network traffic and photovoltaic performance data to deliver a novel, cyber-physical intrusion detection system (IDS) approach that increases the accuracy and effectiveness of detection and mitigation. This hybrid IDS analysis enables dual monitoring that increases the workload of the adversary; both cyber and physical data would have to be simultaneously spoofed to evade detection. Furthermore, monitoring and analyzing cyber data are insufficient in some cases. For example, in an insider threat aimed at disrupting inverter grid-support functions where proper credentials and authentication are achieved, only the altered PV performance would indicate abnormal behavior. All in all, the PIDMS provides novel capabilities for: • Distributed, real-time cyber-physical detection and mitigation analysis • Cybersecurity defense for grid-edge systems • Analysis framework that can provide situational awareness across the transmission, distribution, and DER systems The PIDMS sensor is designed to collect cyber-physical data, process the data using machine-learning algorithms, detect abnormal events, and deploy mitigations. With these goals, the main functional PIDMS objectives are: • Capability to collect cyber-physical data • Onboard storage of cyber-physical data • Peer-to-peer communication • Computationally efficient machine-learning algorithms • Online cyber-physical data analysis • Alerting/visualization capabilities • Mitigation deployment capability with bump-in-the-wire (BITW) implementation Each of these functional objectives enable PIDMS to perform effective cyber-physical intrusion detection and mitigation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Jones, Christian↗

Advanced Inverter Voltage Controls: Simulation and Field Pilot Findings

This report describes work performed by the Hawaiian Electric Companies and the National Renewable Energy Laboratory (NREL) to model and simulate advanced inverter grid-support functions and to validate and expand on those simulations through a field pilot study. This work builds on earlier research, referred to as the Voltage Regulation Operational Strategies study. The objective of both is to investigate functionalities available in most photovoltaic (PV) inverters to modulate active and reactive power autonomously based on local voltage measurements for the purpose of mitigating off-nominal grid voltage conditions. Specifically of interest are volt/volt-ampere reactive (VAR) control and volt/watt control, the effect of those functions on quasi-steady-state feeder voltages, and the impact of the functions on PV energy production. Because volt/VAR and volt/watt control autonomously adjust inverter output based on local conditions without requiring communication with any other devices, they are good candidates to increase PV hosting capacity when it is limited by voltage constraints in a feeder with very large numbers of PV systems.

14 SOLAR ENERGY↗

Development of a Power Electronics-based Testbed for a Flexible Combined Heat and Power System

A flexible combined heat and power (F-CHP) concept, enabled by a power electronics-based power conditioning system (PCS), has been recently proposed as a cost-effective way for supporting the grid with high penetration of renewable energy sources. To verify the design, control, and performance of the overall system, a laboratory-scale testbed is essential. This paper focuses on the development of a power electronics-based testbed for such a F-CHP system. The developed testbed can test the control, grid-connected mode operation, islanded mode operation, and mode transitions, including planned/unplanned islanding and reconnection, of the F-CHP system. In the grid-connected mode, both the steady state and transients of the ac grid can be emulated, and various grid support functions can be tested with the help of the developed PCS converter. In the islanded mode, the external ac loads can also be supported by the F-CHP system. Also, the central controller, which is implemented in a NI CompactRIO, can be tested. Experimental test results for the grid-connected mode, islanded mode, and mode transitions are provided to validate the testbed design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Roadmap for photovoltaic cyber security

Cyber-secure, resilient energy is paramount to the prosperity of the United States. As the experience and sophistication of cyber adversaries grow, so too must the US power system’s defenses, situational awareness, and response and recovery strategies. Traditionally, power systems were operated with dedicated communication channels to large generators and utility-owned assets but now there is greater reliance on photovoltaic (PV) systems to provide power generation. PV systems often communicate to utilities, aggregators, and other grid operators over the public internet so the power system attack surface has significantly expanded. At the same time, solar energy systems are equipped with a range of grid-support functions, that—if controlled or programmed improperly—present a risk of power system disturbances. This document is a five-year roadmap intended to chart a path for improving cyber security for communication-enabled PV systems with clear roles and responsibilities for government, standards development organizations, PV vendors, and grid operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗