Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Gridder, Version 3

GRIDDER is a simple interactive grid generation tool for creating orthogonal, 2D quadrilateral or 3D hexahedral grids. Grid spacing can be even, logarithmic, or geometric. Gridder creates orthogonal one-dimensional, two-dimensional, or three- dimensional grids. Each dimension can have multiple regions, each with different nodal spacing. This spacing can be equal spacing, geometric spacing, or logarithmic spacing. The resulting grid can be output in AVS (Advanced Visualization Systems) format, Tracer 30, Vectors, or FEHM format. Coordinate and connectivity data are output for AVS, but only coordinate data is output for Tracer30. As it runs, Gridder prompts the user for input such as number of dimensions, number of regions in each dimension, coordinates of region borders, number of divisions in each region, spacing specifications of each region, and output format. The Gridder can also accept the necessary information from a file, bypassing the interactive interface. Every time the interactive interface is used, the input parameters are saved to a file so that the same grid can be regenerated from that file.

Gable, Carl↗

Novel artificial neural network model for instantaneous power losses and operational efficiency mapping of MW-scale vanadium redox flow battery for improved technoeconomic analysis

A novel data-driven, machine-learning-based method for modeling the instantaneous power losses of a distribution-sited 2 MW/8MWh vanadium redox flow battery (VRFB), a grid-scale electrochemical storage technology, is introduced and compared against benchmark empirical modeling approaches, including symmetric and asymmetric models, as well as a recent convex hull modeling approach. The novel loss modeling method introduces several advantages over the benchmark models and over simplistic efficiency estimates, the most significant of which is that the model can accurately reflect the stepwise and non-linear parasitic losses associated with the duty cycles of mechanical auxiliary systems like pump motor drives and blower fans. Residuals of the models are compared; the proposed data driven model features significantly improved accuracy over the benchmark models. The model's coefficient of determination is also improved relative to that of the benchmark models. Furthermore, a novel method for visualization of operational efficiency of the grid-scale storage technology is introduced. To demonstrate the benefits of the novel data-driven method for modeling the VRFB, the benchmark models and the proposed models are embedded into an Open DSS distribution network model to study two applications of the grid-scale electrical storage system: load leveling for grid support and energy arbitrage. This article demonstrates that the accuracy of the instantaneous power loss model significantly impacts the understanding of the state of charge of the VRFB. In turn, the accuracy of the efficiency modeling of the VRFB impacts the understanding of the potential economic value and technical benefits to the distribution network operators. In conclusion, the presented power loss modeling approach is, therefore, highly relevant for utility-stakeholders, battery asset owners, system engineers, system designers, and financial planners interested in evaluating or optimizing the operation of grid-scale VRFBs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resource Cybersecurity Framework and Cyber Range Integration

Distributed energy resource (DER) systems feature complex, data-driven communications networks that require careful system coordination and constant vigilance to ensure that grid assets are secure. Because DERs are an important component of the decarbonization strategy, agencies need to secure energy data that could implicate issues of national security if compromised. To help federal energy managers assess, monitor, and manage cybersecurity while achieving decarbonization, the National Renewable Energy Laboratory's (NREL's) Distributed Energy Resource Cybersecurity Framework (DER-CF) offers a comprehensive, web-based assessment tool focusing on cyber governance or policies, technical management, and physical security. The DER-CF currently presents users with a series of pertinent cybersecurity questions that are used to generate a site-specific report and recommendations. This paper outlines a plan to integrate the DER-CF with another key asset-NREL's cyber range-to visualize cybersecurity resilience and compliance and to enhance the usability and accessibility of the DER-CF for federal facility energy managers and planners. This integration will result in a visualization environment to interpret and interact with compliance data. Its development will include regular conversations with stakeholders to assess the effectiveness of these efforts, refine the visualization capability, and ensure its value to our partners.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrophasor Visual Integration and Event Evaluation for Utilities (SynchroVIEEU) with High Penetration of Renewables

The Hawaiian Electric Companies (Companies), operating independent grid systems on the islands of Oahu, Hawaii, Maui, Molokai and Lanai, have been contending with some of the highest levels of renewable generation from both utility-scale and distributed generation resources. Renewable penetration levels exceeding 50% of generation are some of the highest in the nation and are changing the system characteristics and requiring operational changes to grid management. The Companies have aggressively leveraged federal, multi-state and industry grant funding to demonstrate new technologies for monitoring, visualization, forecasting and analysis to inform transformation needs and to improve operational awareness, especially at the distribution level. As part of the American Recovery and Reinvestment Act (ARRA) supported efforts to facilitate integration of renewables, synchrophasor devices were deployed on the islands of Hawaii and Maui in 2010. The devices have potential to provide Hawaii Electric Light Company (HELCO) on Hawaii Island and Maui Electric Company (MECO) with additional information to support post-event analysis and to help quantify observed area-wide changes in voltage and frequency on the systems. Consistent with the U.S. Department of Energy’s (DOE) Office of Electricity Delivery and Energy Reliability (OE) FOA objectives, the goal of this project was to accelerate the integration of synchrophasor information into production grade data visualization and analysis platforms/models to inform timely, efficient and reliable operations of a modern grid in light of high penetrations of renewable resources. The project comprised a two-year development effort to investigate the integration and visualization of synchrophasor field data into production-ready transmission and distribution proactive modeling efforts and a common data analysis platform application currently being used by the Companies. Conceptually, the project was about getting the right data to the right people at the right time in an easily accessible and timely environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Turbulent Flow around a Rod Bundle Induced by a 5 x 5 PWR Mixing Vane Grid using Particle Tracking Velocimetry

This study presents an experimental visualization technique developed for the measurement of the lateral liquid velocity components within a vertical up-flow 5 x 5 rod bundle. The experimental technique uses refractive index matching (RIM) and time resolved particle tracking velocimetry (PTV) to obtain full field measurements at different axial locations. Relevant features of the technique are first, the multi-scale capability, which allows measurements either on a single subchannel or measurements to include the full bundle accounting for the 25 rods and corresponding liquid subchannels. Secondly, the use of FEP tubes to match the refractive index of water allows a uniform illumination which in turn reduces the velocity measurements uncertainty, and third, the use of a high energy continuous laser allows for the temporal evaluation of fluctuating structures within the bundle. This study was conducted with the aim to quantify the effect of the mixing vanes on the development of the liquid turbulence and to test the motivation feasibility of the technique to serve as a benchmark for advanced CFD simulations. In this context, there have been multiple experimental studies with the objective to improve the database for CFD benchmarking purposes. Several experimental techniques have been used to this end; for instance, laser doppler velocimetry (LDV) is a preferred tool to measure the axial and lateral velocity components through bundles due to its accuracy. Although LDV is a mature technique, it only provides point measurements which do not allow for the instantaneous investigation of the momentum exchange among neighboring subchannels; moreover, the small spaces between the rods and within the subchannels makes LDV measurements difficult. In the other hand, flow visualization techniques can provide a 2D map of the instantaneous and average structure of the liquid velocity. Among the used visualization techniques, PIV has gained a lot of attention due to its high accuracy, relative simple application, and non-intrusiveness. Several studies had applied PIV to study the flow structures within bundles sub-channels with some success; however, in these studies there exist an increased uncertainty due to reflections and shadows from the rods. Shadows and undesired reflections appear when the light passes through materials with different refractive indexes. This issue was addressed in other studies on which the refractive index of the rod bundle (or sections of it) was matched with that of water. These studies used particle tracking velocimetry (PTV) and obtained comparable results with LDV measurements. This success indicated that RIM-PTV experiments can be successfully implemented to gather information for simulation benchmarking. The present work is an extension of previous efforts on which measurements were performed only on vertical planes but lacked of the important flow structures that can only be observed through a horizontal cross section of the bundle at different axial height. The focus of the present study was to fill this information gap by measuring the lateral velocity in horizontal planes at different heights. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Final Report to the National Energy Technology Laboratory on FY14- FY15 Cooperative Research with the Consortium for Electric Reliability Technology Solutions

The Power System Engineering Research Center (PSERC) engages in technological, market, and policy research for an efficient, secure, resilient, adaptable, and economic U.S. electric power system. PSERC, as a founding partner of the Consortium for Electric Reliability Technology Solutions (CERTS), conducted a multi-year program of research for U.S. Department of Energy (DOE) Office of Electricity Delivery and Energy Reliability (OE) to develop new methods, tools, and technologies to protect and enhance the reliability and efficiency of the U.S. electric power system as competitive electricity market structures evolve, and as the grid moves toward wide-scale use of decentralized generation (such as renewable energy sources) and demand-response programs. Phase I of OE’s funding for PSERC, under cooperative agreement DE-FC26-09NT43321, started in fiscal year (FY) 2009 and ended in FY2013. It was administered by DOE’s National Energy Technology Laboratory (NETL) through a cooperative agreement with Arizona State University (ASU). ASU provided sub-awards to the participating PSERC universities. This document is PSERC’s final report to NETL on the activities for OE, conducted through CERTS, from September 2015 through September 2017 utilizing FY 2014 to FY 2015 funding under cooperative agreement DE-OE0000670. PSERC is a thirteen-university consortium with over 30 industry members. Since 1996, PSERC has been engaged in research and education efforts with the mission of “empowering minds to engineer the future electric energy system.” Its work is focused on achieving: • An efficient, secure, resilient, adaptable, and economic electric power infrastructure serving society • A new generation of educated technical professionals in electric power • Knowledgeable decision-makers on critical energy policy issues • Sustained, quality university programs in electric power engineering. PSERC core research is funded by industry, with a budget supporting approximately 30 principal investigators and some 70 graduate students and other researchers. Its researchers are multi-disciplinary, conducting research in three principal areas: power systems, power markets and policy, and transmission and distribution technologies. The research is collaborative; each project involves researchers typically at two universities working with industry advisors who have expressed interest in the project. Examples of topics for recent PSERC research projects include grid integration of renewables and energy storage, new tools for taking advantage of increased penetration of real-time system measurements, advanced system protection methods to maintain grid reliability, and risk and reliability assessment of increasingly complex cyber-enabled power systems. A PSERC’s objective is to proactively address the technical and policy challenges of U.S. electric power systems. To achieve this objective, PSERC works with CERTS to conduct technical research on advanced applications and investigate the design of fair and transparent electricity markets; these research topics align with CERTS research areas 1 and 2: Real-time Grid Reliability Management (Area 1), and Reliability and Markets (Area 2). The CERTS research areas overlap with the PSERC research stems: Power Systems, Power Markets, and Transmission and Distribution Technologies, as described on the PSERC website (see http://www.pserc.org/research/research_program.aspx). The performers were with Arizona State University (ASU), Cornell University (CU), University of California at Berkeley (UCB), and University of Illinois at Urbana-Champaign (UIUC). PSERC research activities in the area of reliability and markets focused on electric market and power policy analyses. The resulting studies suggest ways to frame best practices using organized markets for managing U.S. grid assets reliably and to identify highest priority areas for improvement. PSERC research activities in the area of advanced applications focused on mid- to long-term software research and development, with anticipated outcomes that move innovative ideas toward real-world application. Under the CERTS research area of Real-time Grid Reliability Management, PSERC has been focused on Advanced Applications Research and Development (AARD), a subgroup of activities that works to develop advanced applications and tools to more effectively operate the electricity delivery system, by enabling advanced analysis, visualization, monitoring and alarming, and decision support capabilities for grid operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time Sequence Machine Learning-Based Data Intrusion Detection for Smart Voltage Source Converter-Enabled Power Grid

Smart inverters of distributed energy resources can enable cloud computing, condition monitoring, result visualization, remote control, and peer-to-peer energy trading in advanced power systems. However, the advent of data injection attacks in the communication architecture can alter measurement characteristics of power grids and have devastating consequences. In this article, we propose a time sequence machine learning-based anomaly detection methodology for detecting cyber intrusion into control signal setpoints and dc voltage signal measurement bias of the voltage source converter (VSC) in wind generators. We first investigated the effects of four types of denial of service, tampering signal, and stealthy-type data intrusion attacks on smart VSCs and overall wind farms. We then proposed a novel time sequence machine learning-based intrusion detection framework that can be implemented to detect different cyberattacks in the VSCs. The performance of the proposed framework has been compared with that of autoencoder and clustering-based intrusion detection framework. The proposed framework was validated by using the IEEE 39 bus power system in the presence of four wind farms in different locations. Using several metrics for intrusion detection performance, we validated the effectiveness of the proposed framework.

42 ENGINEERING↗

Grid Data Crossing Platform (GriD-Xing)

This project is to develop a data management and analytics platform called Grid Data Crossing (GriD-Xing) that integrates data processing, storage, analysis, and visualization functionalities for users at industry (e.g., EMS and DMS) and universities. It intends to increase the applicability of large set of multi-source data (e.g., SCADA, PMU, μPMU, AMI, inverter, load/DER forecasting, and cyber data) and eventually improve the resilience, reliability, and security of critical energy infrastructure. GriD-Xing also intends to be a research platform to identify the usefulness of large multi-source data via case studies of interest to industry (e.g., 2011 southwest cold weather and 2016 Blue Cut fire events). In the first year, the team focused on the development and demonstration of large multi-source data (e.g., PMU, μPMU, SCADA, AMI, and cyber data) processing, storage, and analysis. Specifically, the team designed GriD-Xing framework in functional and structural aspects, developed GriD-Xing algorithms for large multi-source grid data processing, storage, and analysis, and finally demonstrated GriD-Xing prototype algorithms performance through a series of tests and case studies using real-world and simulation data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of Mesoscale Cellular Convection in Marine Stratocumulus: 2. Nondrizzling Conditions

This is the second of two large-eddy simulation studies on the mechanisms of mesoscale cellular organization in drizzling (open cells) and nondrizzling marine stratocumulus (closed cells). This study uses a hard nudging approach which maintains fixed horizontal-mean temperature and humidity profiles for a well-mixed boundary layer with a constant boundary layer depth. For the case studied, closed cells develop and broaden by 32 hr to an aspect ratio of 25. Simulations show that the closed-cell mesoscale cellular convection is driven by positive feedback from cloud-induced mesoscale perturbations of longwave radiative cooling. A conceptual model for closed-cell stratocumulus as a mesoscale wavelength hydrodynamic instability in which mesoscale moist and dry anomalies spontaneously grow is presented. In simulations in which long-wavelength sinusoidal moisture anomalies are initially imposed, these anomalies evolve into amplifying closed cells. The cell structure is visualized with a compositing approach based on sorting grid columns by their mesoscale-smoothed total water path. A thermally direct mesoscale circulation pattern develops in the interior of the boundary layer with buoyant mesoscale updrafts, thicker cloud, and a slightly higher capping inversion in the moister columns. There is a mesoscale flow of above-inversion air down the slightly sloping capping inversion from the moist to the dry regions, reinforced by cloud top radiative cooling. This strengthens the mesoscale anomalies by preferentially cooling and drying the already dry regions. The sloping inversion flow is not driven as efficiently if the radiative cooling is artificially horizontally homogenized, partly disrupting this positive feedback and the resulting closed-cell development.

54 ENVIRONMENTAL SCIENCES↗

Data From: "Warming and snow loss increase reliance on old groundwater in a Colorado River headwater"

This repository contains the data and code associated with the paper titled "Warming and snow loss increase reliance on old groundwater in a Colorado River headwater," published in Nature Geoscience, 2026. This study seeks to answer how various ages of groundwater interact with mountainous streamflow in mountainous headwaters such as the East River. It includes various model-data processing scripts, primarily for ParFlow-CLM analysis of simulated water years 2015-2021, and two numerical warming experiments (+2.5 and +4.0 degrees C), including run scripts, forcing scripts, and post-processing, as well as comparison to observation datasets, detailed below. This data requires the use of R (.r, .rmd), Python (.py), Jupyter Notebook or Jupyter Lab (.ipynb), ParFLOW-CLM, EcoSLIM. Further information on the use of all file formats mentioned below (e.g. .tff. .nc) are provided within the associated scripts and directory where the files are located. Contents & Usage ASO/: ​​Contains the bash and python scripts used to convert airborne snow observatory (ASO) data (ASO, 2023) in various data formats (georeferenced tiff file, NetCDF, UTM, and to latitude/longitude) then regrided to the ParFlow equivalent grid. Output data are in regrid_regll_data.zip and subsequently visualized and analyzed in plot_and_compare.py for Supplementary Figures A14 and A15. The wksht_ASO_comparison.xlsx spreadsheet is used to calculate the data for Supplementary Figure A16. EcoSLIM/: Contains the scripts and input files to run the EcoSLIM particle tracking simulations (/run_scripts) and the post-processing python script (/plot_scripts/eco_agedist_plots.ipynb). Jasechko et al./: Contains the jupyter notebook (Extract_Elevation.ipynb) to determine the outlet elevations of the 260 watersheds used in Jasechko et al. (2016), and the corresponding table, Table_S1_Watersheds_alt.csv. Used to create Supplementary Information Figure A2. PLM_Wells/: Contains the QA/QC-ed groundwater level time series of the PLM-1 and PLM-6 Monitoring Wells from Faybishenko et al. (2023), reformatted to water years used for Supplementary Figures A19 and and A20. ParFlow/: Contains the input files and run scripts to run ParFlow-CLM (/run_scripts), the python and tool command language (Tcl) scripts to create and distribute the ParFlow forcing simulation files (/forcing), and various scripts and intermediary files to analyze the model outputs (/post_process). SQUIRE/: Contains the processing scripts and intermediary files for the Surface QUantitatIve pRecipitation Estimation (SQUIRE) data (Grover, 2023) used to generate Supplementary Figure A18. USGS_Streamflow/: Contains the raw and gap-filled United States Geological Survey streamflow data (U.S. Geological Survey, 2026) used at the Almont station (site number 09112500). Gap-filling is performed in the R script with data from the Taylor station (site number 09110000). (/USGS_09112500_EAST_RIVER_AT_ALMONT_GAP_FILLED/code_almont_streamflow_gap_fill.Rmd). discharge/: Contains the gap-filled discharge data at the Watershed Function SFA East River pumphouse site (Newcomer et al., 2022) used to generate Supplementary Figure A13 and to compute hourly Nash-Sutcliffe model efficiency coefficients (NSE) in Table A4. snotel_and_flux_tower/: Contains the snow telemetry data (U.S. Department of Agriculture, 2024) from the Butte (site ID 380) and Schofield (site ID 737) stations, reformatted by water year, accessed with the snotelr R package. Used to create Supplementary Figure A17. Also contains the flux tower observational data (FluxTower_Pumphouse_ESS-DIVE.ET_only.h.txt) from Ryken et al. (2022) and sap flux transpiration data (MaxB_Transpiration_5Sites.daily_sums.h.txt) from Ryken (2021), used to create Supplementary Figures A22 and A23, respectively. Raw EcoSLIM model outputs are in excess of 24TB, and are stored on National Energy Research Scientific Computing Center (NERSC) and publicly available via the external link provided in the paper.

atmospheric warming↗

Variable Grid Method

NETL’s Variable Grid Method (VGM) is a novel approach that leverages GIS capabilities to simultaneously visualize and quantify spatial data trends and underlying data uncertainty. The flexible VGM approach utilizes a range of spatial datasets and uncertainty quantifications, which can be calculated using data related to sample density, sample variance, interpolation error, multiple simulations, etc., to create an integrated visualization of data and uncertainty. The intuitive manner of the VGM helps communicate the relationship between uncertainty and spatial data to effectively guide research, support advanced computation analyses, and helps inform research, management and policy decisions. The VGM approach is being developed into a standalone tool designed to integrate into a variety of research workflows, providing users the capabilities to utilize the VGM for their datasets, analysis, and models in support of their decision making needs. The VGM approach was developed as part of NETL’s Offshore portfolio. It was further matured and utilized in projects associated with both NETL’s Unconventional Resources and Carbon Storage portfolios, and is now being further developed by Varigrid, LLC.

Carbon Storage↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Paracousti v. 2.0.0

Paracousti simulates 3-D acoustic wave propagation in fixed (non-moving) complex media. It solves the linear acoustic equations of motion using the velocity-pressure system of first order linear differential equations on a finite-difference Cartesian grid using Newton’s law of motion and mass continuity equations. It also has the ability to incorporate acoustic attenuation to simulate non-recoverable energy losses via the velocity-memory-pressure system of linear differential equations. We assume stationary, non-heat conducting, adiabatic media (fluid) where the background sound speed and material density are fixed in time. Capabilities include massively parallel design, optimization for high contrast media interfaces, inclusion of arbitrary pressure and force sources defined by the user, inclusion of arbitrary pressure and velocity receivers defined by the user, acoustic wavefield snapshots in time for visualization, and convolutional perfectly matched layers to minimize artificial grid boundary reflections. Paracousti was built upon the foundational framework of TDAAPS (Time-Domain Atmospheric Acoustic Propagation Suite) by Neill Symons, Dave Aldridge, and Leiph Preston.

Preston, Leiph↗

Supercomputing meets seismology in earthquake exhibit

When the California Academy of Sciences created the "Earthquake: Evidence of a Restless Planet" exhibit, they called on Lawrence Livermore to help combine seismic research with the latest data-driven visualization techniques. The outcome is a series of striking visualizations of earthquakes, tsunamis and tectonic plate evolution. Seismic-wave research is a core competency at Livermore. While most often associated with earthquakes, the research has many other applications of national interest, such as nuclear explosion monitoring, explosion forensics, energy exploration, and seismic acoustics. For the Academy effort, Livermore researchers simulated the San Andreas and Hayward fault events at high resolutions. Such calculations require significant computational resources. To simulate the 1906 earthquake, for instance, visualizing 125 seconds of ground motion required over 1 billion grid points, 10,000 time steps, and 7.5 hours of processor time on 2,048 cores of Livermore's Sierra machine.

58 GEOSCIENCES↗