Search NASA⌕ Search

SEARCH · Search NASA

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Testosterone and muscle hypertrophy in female rats

The effects of chronic treatment with testosterone propionate (TP) on compensatory muscle hypertropy in female rats are examined. The 48 female rats were placed in one of four test groups: (1) no overload (synergist removal), no TP, (2) overload, no TP, (3) no overload + TP, and (4) overload + TP. The technique used to administer the TP is described. The preparation of the plantaris muscle, the analysis of pyruvate oxidation and the determination of malate and lactate dehydrogenases and the noncollogen protein are explained. The results which reveal the effect of overload and TP on body weight, noncollogen protein concentration, lactate and malate dehydrogenase activities, and pyruvate oxidation are presented and discussed. It is concluded that in terms of body weight, protein content, pyruvate, glycolysis, and oxidative metabolisms chronic TP treatments do not change compensatory muscle hypertropy.

Kuhn, F. E.↗

Total-dose radiation effects data for semiconductor devices. 1985 Supplement. Volume 2, part B

Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 (Parts A and B) provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done steady-state 2.5-MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose. All data were generated in support of NASA space programs by the JPL Radiation Effects and Testing Group (514).

Martin, K. E.↗

Effect of boron on intergranular hot cracking in Ni-Cr-Fe superalloys containing niobium

Solidification mechanisms had a dominant influence on microfissuring behavior of the test group. Carbon modified the Laves formation significantly and showed that one approach to alloy design would be balancing carbide formers against Laves formers. Boron's strong effect on microfissuring can be traced to its potency as a Laves former. Boron's segregation to grain boundaries plays at best a secondary role in microfissuring.

Thompson, R. G.↗

Stress-life relation of the rolling-contact fatigue spin rig

The rolling-contact fatigue spin rig was used to test groups of SAE 52100 9.16-inch-diameter balls lubricated with a mineral oil at 600,000-, 675,000-, and 750,000-psi maximum Hertz stress. Cylinders of AISI M-1 vacuum and commercial melts and MV-1 (AISI M-50) were used as race specimens. Stress-life exponents produced agree closely with values accepted in industry. The type of failure obtained in the spin rig was similar to the subsurface fatigue spells found in bearings.

SURFACES, CONTACT - ROLLING↗

Lower Extremity Muscle Thickness During 30-Day 6 degrees Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

Muscle thickness was measured in 19 Bed-Rested (BR) men (32-42 year) subjected to IsoTonic (ITE, cycle orgometer) and IsoKi- netic (IKE, torque orgometer) lower extremity exercise training, and NO Exercise (NOE) training. Thickness was measured with ultrasonography in anterior thigh-Rectus Femoris (RF) and Vastus Intermadius (VI), and combined posterior log-soleus, flexor ballucis longus, and tibialis posterior (S + FHL +TP) - muscles. Compared with ambulatory control values, thickness of the (S + FHL + TP) decreased by 90%-12% (p less than 0.05) In all three test groups. The (RF) thickness was unchanged in the two exercise groups, but decreased by 10% (p less than 0.05) in the NOE. The (VI) thickness was unchanged In the ITE group, but decreased by 12%-l6% (p less than 0.05) in the IKE and NOE groups. Thus, intensive, alternating, isotonic cycle ergometer exercise training is as effective as intensive, intermittent, isokinetic exercise training for maintaining thicknesses of rectus femoris and vastus lntermedius anterior thigh muscles, but not posterior log muscles, during prolonged BR deconditioning.

Ellis, S.↗

Structural Loads Test Measurement Acquisition System (SLTMAS)

This presentation package, a PowerPoint presentation, will be presented at NASA's Sixteenth Annual Continual Improvement and Reinvention Conference as part of an Agency level competition highlighting continual improvements within NASA. The presentation provides a brief overview of the process used to improve the Structural and Dynamics Testing Group's data acquisition capabilities. Results measuring the success of the improvement cycle for the PC based SLTMAS will be presented.

Patterson, Alan↗

Computing and combustion

Coming into the Combustion Branch of the Turbomachinery and Propulsion Systems Division, there was not any set project planned out for me to work on. This was understandable, considering I am only at my sophmore year in college. Also, my mentor was a division chief and it was expected that I would be passed down the line. It took about a week for me to be placed with somebody who could use me. My first project was to write a macro for TecPlot. Commonly, a person would have a 3D contour volume modeling something such as a combustion engine. This 3D volume needed to have slices extracted from it and made into 2D scientific plots with all of the appropriate axis and titles. This was very tedious to do by hand. My macro needed to automate the process. There was some education I needed before I could start, however. First, TecPlot ran on Unix and Linux, like a growing majority of scientific applications. I knew a little about Linux, but I would need to know more to use the software at hand. I took two classes at the Learning Center on Unix and am now comfortable with Linux and Unix. I already had taken Computer Science I and II, and had undergone the transformation from Computer Programmer to Procedural Epistemologist. I knew how to design efficient algorithms, I just needed to learn the macro language. After a little less than a week, I had learned the basics of the language. Like most languages, the best way to learn more of it was by using it. It was decided that it was best that I do the macro in layers, starting simple and adding features as I went. The macro started out slicing with respect to only one axis, and did not make 2D plots out of the slices. Instead, it lined them up inside the solid. Next, I allowed for more than one axis and placed each slice in a separate frame. After this, I added code that transformed each individual slice-frame into a scientific plot. I also made frames for composite volumes, which showed all of the slices in the same XYZ space. I then designed an addition companion macro that exported each frame into its own image file. I then distributed the macros to a test group, and am awaiting feedback. In the meantime, a am researching the possible applications of distributed computing on the National Combustor Code. Many of our Linux boxes were idle for most of the day. The department thinks that it would be wonderful if we could get all of these idle processors to work on a problem under the NCC code. The client software would have to be easily distributed, such as in screensaver format or as a program that only ran when the computer was not in use. This project proves to be an interesting challenge.

Thompson, Daniel↗

Spinoff For Survival

The Givens Buoy Raft cannot be overturned, its manufacturer claims and others concur. An independent test group conducted a series of demonstrations and found that every type of raft :I except the Givens could be capsized either by one man boarding or several shifting weight within the raft. Termed by the group "a remarkable stability achievement," the Givens Buoy raft offers the first major advance in inflatable survival equipment in many years. It is a spinoff product resulting in part from NASA technology and in part from years of research by Jim Givens, president of Res-Q-Raft, Inc., of Lake Worth, Florida and Seattle, Washington. NASA used inflatable rafts to transfer astronauts returning from space between their ocean-landed spacecraft and a recovery ship. NASA found a problem in the use of conventional flat-bottom inflatables; they tended to overturn when exposed to the downdraft from helicopters of the recovery fleet. So Johnson Space Center developed a new and highly-effective method of raft stabilization for which NASA secured a patent. Working separately, Jim Givens came up with a very similar system. He subsequently patented his own invention and secured an exclusive patent license to use the NASA technology

Source record↗

ISS SGANT Group Level Offloading Test Mechanism

The International Space Station (ISS) Space-to-Ground Antenna (SGANT) is used for ISS communication with earth through the Tracking and Data Relay Satellite (TDRSS). Due to the different speeds of travel between earth, ISS and TDRSS, a steerable SGANT was required on the ISS. The mechanical design of SGANT is an unbalanced mechanism with insufficient strength and driving torque to support and drive itself in a 1G environment. For ground testing, a specially designed offloading mechanism is required. Basically, the test mechanism must offload the SGANT in a two-axis operation, allowing the SGANT to move within a specific range, speed and acceleration; therefore the SGANT can move from elevation 0 to 90 deg and be tested at both the 0 and 90 deg positions. The load introduced by the test equipment should be less than 10.17 N-m (7.5 ft-lbf). The on-ground group level tracking test is quite challenging due to the unbalanced antenna mechanical design and tough specification requirements. This paper describes the detailed design, fabrication, and calibration of the test mechanism, and how the above requirements are met. The overall antenna is simplified to a mass model in order to facilitate the offloading mechanism design and analysis. An actual SGANT mass dummy was made to calibrate the system. This paper brings together the theoretical analysis and the industrial experience that were relied upon to meet the above-mentioned requirements for the ground test. The lessons learned during the calibration phase are extremely important for future double or multiple offloading system designs. The ISS SGANT QM and FM units passed their ground test and the SGANT/Boom fit check successfully, and the Flight Model (FM) was delivered to SSPF in April 1998. It is now installed on ISS and functioning well.

Zhang, Xi-Lin↗

Euler computations of AGARD Working Group 07 airfoil test cases

In an attempt to provide a set of accurate standard test problems for computational code developers, a series of inviscid airfoil test cases were chosen by the AGARD Working Group 07, a subpanel of the AGARD Fluid Dynamics Panel. The cases include three different airfoils at transonic to supersonic conditions. A large number of international experts responded in this effort with computations that have been contrasted for accuracy and consistency. This paper is a summary of the authors' contribution to this study. In particular, the important aspects of the solution process that made it possible to obtain the high level of accuracy needed in this study are stressed.

Pulliam, T. H.↗

Application of differential similarity to finding nondimensional groups important in tests of cooled engine components

The method of differential similarity is applied to the partial differential equations and boundary conditions which govern the temperature, velocity, and pressure fields in the flowing gases and the solid stationary components in air-cooled engines. This procedure yields the nondimensional groups which must have the same value in both the test rig and the engine to produce similarity between the test results and the engine performance. These results guide the experimentalist in the design and selection of test equipment that properly scales quantities to actual engine conditions. They also provide a firm fundamental foundation for substantiation of previous similarity analyses which employed heuristic, physical reasoning arguments to arrive at the nondimensional groups.

Sucec, J.↗

JANTX/N759A voltage regulating diode

Diodes manyfactured by Texas Instruments and Siemens performed well in group I testing. Failure analysis shows that group II testing is most detrimental to both sample lots. Same failure mode of excessive I(sub) R leakage can be clearly seen in group III testing.

Source record↗

A model for the formation of the Local Group

Observational tests of a model for the formation of the Local Group are presented and analyzed in which the mass concentration grows by gravitational accretion of local-pressure matter onto two seed masses in an otherwise homogeneous initial mass distribution. The evolution of the mass distribution is studied in an analytic approximation and a numerical computation. The initial seed mass and separation are adjusted to produce the observed present separation and relative velocity of the Andromeda Nebula and the Galaxy. If H(0) is adjusted to about 80 km/s/Mpc with density parameter Omega = 1, then the model gives a good fit to the motions of the outer members of the Local Group. The same model gives particle orbits at radius of about 100 kpc that reasonably approximate the observed distribution of redshifts of the Galactic satellites.

Peebles, P. J. E.↗

Fracture behavior of hybrid composite laminates

The tensile fracture behavior of 15 center-notched hybrid laminates was studied. Three basic laminate groups were tested: (1) a baseline group with graphite/epoxy plies, (2) a group with the same stacking sequence but where the zero-deg plies were one or two plies of S-glass or Kevlar, and (3) a group with graphite plies but where the zero-deg plies were sandwiched between layers of perforated Mylar. Specimens were loaded linearly with time; load, far field strain, and crack opening displacement (COD) were monitored. The loading was stopped periodically and the notched region was radiographed to reveal the extent and type of damage (failure progression). Results of the tests showed that the hybrid laminates had higher fracture toughnesses than comparable all-graphite laminates. The higher fracture toughness was due primarily to the larger damage region at the ends of the slit; delamination and splitting lowered the stress concentration in the primary load-carrying plies. A linear elastic fracture analysis, which ignored delamination and splitting, underestimated the fracture toughness. For almost all of the laminates, the tests showed that the fracture toughness increased with crack length. The size of the damage region at the ends of the slit and COD measurements also increased with crack length.

Kennedy, J. M.↗

JANTX1N5552 switching diode

Switching diodes manufactured by Micro Semidonductor and Semtech were tested. In groups 2 and 3 there were no Micro Semiconductor catastrophic failures. Testing of both lots was stopped in group 1 test because of 50% failure rate.

Source record↗