Search NASA⌕ Search

SEARCH · Search NASA

Results for “harmonic distortion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Anomaly Detection in Power Quality at Data Centers

The goal during my internship at the National Center for Critical Information Processing and Storage (NCCIPS) is to implement an anomaly detection method through the StruxureWare SCADA Power Monitoring system. The benefit of the anomaly detection mechanism is to provide the capability to detect and anticipate equipment degradation by monitoring power quality prior to equipment failure. First, a study is conducted that examines the existing techniques of power quality management. Based on these findings, and the capabilities of the existing SCADA resources, recommendations are presented for implementing effective anomaly detection. Since voltage, current, and total harmonic distortion demonstrate Gaussian distributions, effective set-points are computed using this model, while maintaining a low false positive count.

Grichine, Art↗

Single-stage transmitter for wireless power transfer

A single-stage transmitter for wireless power transfer is provided. The transmitter includes a rectifier stage and an inverter stage sharing a first phase leg. The rectifier stage further includes a rectifying leg including two diodes connected in series, and a boost inductor coupling the first phase leg and the rectifying leg to an input port. The inverter stage further includes a second phase leg. Each phase leg includes two switches connected in series. The first and second phase legs are coupled to an output port. A bus capacitor is coupled across the first phase, second phase, and rectifying legs. A controller is programmed to determine first and second parameters, based on an output power at the output port, to simultaneously control the rectifier stage and the inverter stage to maintain constant bus voltage and achieve high power factor and low total harmonic distortion at the input port.

Costinett, Daniel Jes↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Propulsion System Design using a Dual 3-Phase PM Synchronous Reluctance Machine with X-Type Multi-Level GaN Inverter

— A propulsion system design is exhibited here that comprises of an X-type GaN power module based dual multi-level inverter and a PM Synchronous Reluctance motor. With the critical benefits of multi-level operation, namely low common mode EMI noise, low switching loss, low current Total Harmonic Distortion (THD), smoother torque and lower iron loss, this topology targets high system-level efficiency and high power density while using reduced rare earth (RE) elements in its motor. General Motors and Purdue University jointly designed and developed this 800V class, highly scalable traction drive that can deliver 200+ kW of power suitable for C-SUV to truck vehicle class. The 3-phase electric machine design utilizes dual winding with 6 terminals to work in line with the GaN X-type inverter, and results in a tractive solution that ensures higher machine efficiency while reducing cost and uncertainty related to use and availability of heavy rare earth/rare earth elements in its rotor.

MOMEN, FAIZUL [General Motors LLC, Detroit, MI (Un↗

Radio frequency distortion in plasmas.

RF harmonic and intermodulation distortion produced by glow discharge and high energy flame plasmas during electromagnetic wave propagation

Trammell, R. D., Jr.↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benchmarking Real-Time Control Platforms Using a Matlab/Simulink Coder with Applications in the Control of DC/AC Switched Power Converters

In the control of DC/AC switched power converters (SPC), one of the most important aspects to be considered is the selection of the real-time control platform. The real-time control platform must be able to meet the high performance efficiency and regulation requirements of the DC/AC SPC, as these typically operate at switching frequencies in the order of kHz to MHz. For this reason, the hardware characteristics of the ADC and PWM, and the processing capacity of the real-time control platform are of vital importance when implementing advanced digital controllers that maintain voltage and current levels within regulatory standards. In this context, we aimed to perform a comparative study of the computation times of different real-time control platforms when implementing different control strategies for DC/AC switched power converters. We also analyzed the impact of the real-time control platforms on the THD of the voltages generated by the DC/AC switched power converters. With the help of this paper, researchers and developers will have criteria to select which real-time control platform to use in real-time control for DC/AC SPC applications.

42 ENGINEERING↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interaction of finite-amplitude sound with air-filled porous materials

The propagation of high intensity sound waves through an air-filled porus material was studied. The material is assumed: (1) to be rigid, incompressible, and homogeneous, and (2) to be adequately described by two properties: resistivity r and porosity. The resulting wave equation is still nonlinear, however, because of the u sgn(u) term in the resistivity. The equation is solved in the frequency domain as an infinite set of coupled inhomogeneous Helmholtz equations, one for each harmonic. An approximate but analytical solution leads to predictions of excess attenuation, saturation, and phase speed reduction for the fundamental component. A more general numerical solution is used to calculate the propagation curves for the higher harmonics. The u sgn(u) nonlinearity produces a cubic distortion pattern; when the input signal is a pure tone, only odd harmonic distortion products are generated.

Nelson, D. A.↗

Reducing distortion in an fm modulator.

Free-running oscillator incorporating correction circuit to improve linearity of voltage-variable capacitor for reducing second harmonic and intermodulation distortion

FREQUENCY MODULATION↗

Nearly spherical constant-power detonation waves as driven by focused radiation

An analysis is made of the flow within a three-dimensional explosion, or spark, created in a gas absorbing energy from a steady conical beam of radiation with nearly spherical symmetry. The radiation, typically from an array of lasers with a common focus, is assumed to be very intense and absorbed immediately behind an outwardly advancing strong shock. Departures of the laser power from spherical uniformity, which would result from practical problems of arrangement, are conveniently represented by an ascending series of Legendre polynomials in the polar angle. For nonuniformities of small amplitude, first-order perturbations of the flow field are analyzed in detail. Self-similarity is shown to be retained for zero counter-pressure and power constant with time. For the first five harmonics in power distortion, the resulting fourth-order system of equations is solved numerically for profiles of velocity components, density, pressure, and shock shape. Results are presented graphically.

George, Y. H.↗

Nanoionics-Based Switches for Radio-Frequency Applications

Nanoionics-based devices have shown promise as alternatives to microelectromechanical systems (MEMS) and semiconductor diode devices for switching radio-frequency (RF) signals in diverse systems. Examples of systems that utilize RF switches include phase shifters for electronically steerable phased-array antennas, multiplexers, cellular telephones and other radio transceivers, and other portable electronic devices. Semiconductor diode switches can operate at low potentials (about 1 to 3 V) and high speeds (switching times of the order of nanoseconds) but are characterized by significant insertion loss, high DC power consumption, low isolation, and generation of third-order harmonics and intermodulation distortion (IMD). MEMS-based switches feature low insertion loss (of the order of 0.2 dB), low DC power consumption (picowatts), high isolation (>30 dB), and low IMD, but contain moving parts, are not highly reliable, and must be operated at high actuation potentials (20 to 60 V) generated and applied by use of complex circuitry. In addition, fabrication of MEMS is complex, involving many processing steps. Nanoionics-based switches offer the superior RF performance and low power consumption of MEMS switches, without need for the high potentials and complex circuitry necessary for operation of MEMS switches. At the same time, nanoionics-based switches offer the high switching speed of semiconductor devices. Also, like semiconductor devices, nanoionics-based switches can be fabricated relatively inexpensively by use of conventional integrated-circuit fabrication techniques. More over, nanoionics-based switches have simple planar structures that can easily be integrated into RF power-distribution circuits.

Nessel, James↗

Reconstruction of magnetic island electron temperature in mixed second and third harmonic electron cyclotron emission conditions

Here we develop a method to use the mixed third and second harmonic electron cyclotron emission (ECE) signal in the DIII-D tokamak to reconstruct the electron temperature profile of a rotating magnetic island. The third harmonic ECE is removed by extracting the rotating-island-associated fluctuations in the mixed signal, and the extracted fluctuation is combined with the equilibrium temperature obtained from other diagnostics after correcting for the third harmonic reabsorption. The accuracy of the reconstruction is studied by considering a DIII-D shot where an unmixed signal from an island is available on the low field side of the plasma and a mixed signal from the same island is available from the high field side. It is found that the reconstruction method successfully reproduces the island shape and temperature perturbation magnitude without the distortion caused by third harmonic ECE mixing. However, the radial location of the reconstructed island is somewhat displaced relative to the location of the q = 2 surface in the axisymmetric equilibrium reconstruction, resulting in a corresponding inaccuracy in the absolute temperature of the island. It is conjectured that this may arise from an inaccuracy of the reconstructed axisymmetric equilibrium in this region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of laminar-turbulent transition in a spatially-developing flat plate wake

Laminar-turbulent transition of an incompressible flat-plate wake is investigated by direct numerical integration of the Navier-Stokes equations. For the numerical integration, a combination of finite-difference and spectral methods along with an ADI/Crank-Nicolson/Adams-Bashforth time integration scheme is employed. Subject to 2D forcing, the wake exhibited a rapidly-growing fundamental disturbance that quickly saturated. This saturation was due partly to the stabilizing effect of the mean flow distortion. Downstream of the saturation point, disturbance energy was concentrated in the fundamental disturbance, the second harmonic, and the mean flow distortion component. At large amplitude levels, a Karman vortex street formed. Variations in the 2D forcing level did not alter the qualitative behavior of the disturbances. Simulations of 3D breakdown indicates that the presence of large-amplitude, 2D disturbances tends to initially suppress small-amplitude 3D disturbance growth. Following this initial suppression, a resumption of 3D growth is observed that may have been due to a secondary instability mechanism. For high levels of 3D disturbance energy, lambda-shaped vortical structures formed between adjacent Karman vortices.

Dratler, D. I.↗