Search NASA⌕ Search

SEARCH · Search NASA

Results for “hazard components”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

MARVEL Hazard Evaluation ECAR-6440

MARVEL Hazards Evaluation evaluated the impacts of MARVEL operations, hazards, and postulated accidents. The hazard evaluation of MARVEL events and associated operations was performed for selection and evaluation of safety classification of systems, structures, and components (SSCs) and SSC safety functions, and for selection of design basis accidents (DBAs) applicable to the MARVEL microreactor design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Conceptual Design for a Blanket Tritium Extraction Test Stand

Future fusion reactors must be able to breed the tritium they will consume. Several breeding and tritium extraction technologies are under investigation internationally. PbLi is of particular interest as a breeder material. A new forced convection PbLi loop, the Tritium Extraction eXperiment (TEX), is being designed and constructed to investigate tritium extraction from PbLi. Specifically, TEX will serve to investigate the extraction efficiency of various vacuum permeator membranes and configurations. The major components of the loop include a moving magnet pump, reverse permeator, furnace test section, analysis chamber, supply tank, and plenum. As significant hazards are present in such experiments, safety is an integral focus of the experimental design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessing Historical Extreme Weather Event Impacts

Resilience planning, particularly energy and water resilience planning, has been a key priority for the federal government for many years, leading federal agencies to develop processes for identifying and addressing critical resilience gaps at their facilities and sites. Furthermore, recent federal policy is driving agencies to prioritize climate change impacts as a more central component of their resilience planning efforts. To achieve this, federal sites must understand their vulnerability to climate change, which involves identifying climate hazards projected to impact the site (known as exposure), as well as understanding the sensitivity (the degree to which a site, including its people and the things they value, could be harmed by that exposure), and adaptive capacity of the site (the degree to which the site could lessen bathe potential for harm by taking action to reduce exposure and sensitivity). To assess and understand sensitivity and adaptive capacity, it is important to first obtain a baseline and understand how a site has been impacted by past events, in addition to considering the potential for unprecedented impacts based on climate projections. This information paper highlights current limitations for developing event history assessments and suggests a framework for more consistently capturing key data points. The purpose of this paper is to help inform how organizations could begin structuring a comprehensive process for recording the impacts of extreme weather events in order to facilitate climate vulnerability assessments, and thus, resilience planning.

54 ENVIRONMENTAL SCIENCES↗

Toward the application of the Risk-Based Maintenance approach to a hydrogen-fueled manufacturing plant

Safety, reliability, and maintenance of hydrogen-based equipment, including Risk-Based Maintenance (RBM), have recently gained increasing attention, as hydrogen, while key to decarbonizing hard-to-abate sectors, raises safety concerns. However, two literature gaps limit the development of risk-based strategies for hydrogen technologies. First, existing RBM methodologies do not account for hydrogen-specific components, such as electrolyzers, which differ from conventional equipment. Second, available studies on electrolyzer reliability remain largely qualitative or laboratory-scale. This study addresses these gaps by proposing an adapted RBM methodology tailored to hydrogen-fueled manufacturing facilities. Integrating qualitative tools (e.g., FMEA) with probabilistic models (e.g., Bayesian Networks) enables comprehensive hazardous scenarios identification and likelihood estimation. A conceptual layout of a glass furnace supplied by a 3 MW PEM electrolyzer is considered as a case study to demonstrate the feasibility of the adapted RBM framework in identifying high-risk components and enabling maintenance prioritization, potentially improving plant safety.

08 HYDROGEN↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

Characterizing Hazardous Gases from NMC811 Materials and Coin Cells with TGA and Tube-Furnace FTIR-MS Evolved-Gas-Analysis

Abuse testing is useful for informing the risks of different battery chemistries but has been limited to larger formats. This paper conducted thermal abuse tests at the smaller coin cell level to determine its relevance in specifying vent gas flammability and toxicity. A nitrogen purge carried the evolved gases into a parallel Fourier-transform infrared spectrometer (FTIR) and a mass spectrometer (MS) downstream of the tube furnace. The experimental system was validated by comparing evolved gas data for single components between the tube furnace system and a thermogravimetric analysis (TGA) instrument. Multiple samples were tested during validation, including CaCO3, electrolyte, delithiated NMC 811 cathode, and lithiated graphite anode. Temperature-resolved gas evolution of HF, CO2, CO, H2, and hydrocarbons from isolated components helped to characterize the emission sources. A previously unreported H2 generation mechanism was found. It was shown that the reduced NMC cathode acts as a catalyst to crack polypropylene-decomposed hydrocarbons into H2 at around 450 degrees C. It was also shown, while studying LiPF6 thermal decomposition, that using the tube furnace with a coin cell casing as the sample holder has some advantages for evolved-gas analysis of environmentally sensitive samples relative to testing in TGA instruments. After validation with single components, a fully charged NMC 811 coin cell was failed in the tube furnace. The measured evolved gases were found to be a combination of the species measured from the single component tests. H2 formation related to the reduced cathode was found to have greater abundance than H2 formed from the anode. Hydrogen fluoride emission factors and diethyl carbonate conversion emission factors assist in understanding the gaseous hazards for larger format cells.

25 ENERGY STORAGE↗

Database-wide hazard modelling of the onset of DIII-D tearing modes with field features

The rate of onset (hazard) of tearing modes is modelled probabilistically using statistical learning algorithms. Axisymmetric energy-density equilibrium fields are taken as raw high-dimensional input features which are reduced with principal component analysis. Signal processing of non-axisymmetric magnetics fluctuation array data provides the target information from which to learn. Model selection, visualization and calibration assessment procedures are detailed. Here, the analysis is deployed at large scale across the DIII-D tokamak database. Standard model selection criteria suggest that the energy-density post-processed feature is a better choice for modelling the onset rate compared to the non-processed equilibrium reconstruction solution. Two example applications of the learned rate function are demonstrated: (i) proximity-to-onset discharge monitoring and (ii) database analysis showing an (expected) observational global trend that the general hazard increases as a plasma performance metric increases. An important connection between the hazard function and its use as a conditional probability generator is reviewed in the Appendix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton nuclear magnetic resonance (1H NMR) of flammable organic chemicals in radioactive high–level supernatant waste at the Savannah River Site (SRS)

The Savannah River Site stores approximately 36 million gallons of radioactive and hazardous waste that contains approximately 245 million curies. The waste is sent through various chemical processes to reduce its volume and to separate various components. The facility plans to replace formic acid (a chemical used to reduce soluble mercury) with glycolic acid. Recycle solution with glycolate may flow back to the tank farm, where the glycolate can generate hydrogen gas by thermal and radiolytic mechanisms. The current analytical method for detecting glycolate (ion chromatography) in supernatant requires a large dilution to reduce interference from the nitrate anions. Hydrogen nuclear magnetic resonance is an analytical method that requires less sample dilution. It takes advantage of the CH 2 group in glycolate. Liquid samples were spiked with four different levels of glycolate to build a calibration line, as it is recommended in the standard addition method. The detection and quantitation limits determined were 1 and 5 ppm, respectively, for 32 scans, which is well below the process limit of 10 ppm. In one test, 800 scans of a supernatant spiked with 1 ppm glycolate resulted in a -CH 2 peak with a signal-to-noise ratio of 36.

1H↗

Olivine Dissolution in Simulated Lung and Gastric Fluid as an Analog to the Behavior of Lunar Particulate Matter Inside the Human Respiratory and Gastrointestinal Systems

With the Artemis III mission scheduled to land humans on the Moon in 2025, work must be done to understand the hazards lunar dust inhalation would pose to humans. In this study, San Carlos olivine was used as an analog of lunar olivine, a common component of lunar dust. Olivine was dissolved in a flow-through apparatus in both simulated lung fluid and 0.1 M HCl (simulated gastric fluid) over a period of approximately 2 weeks at physiological temperature, 37°C. Effluent samples were collected periodically and analyzed for pH, iron, silicon, and magnesium ion concentrations. The dissolution rate data derived from our measurements allow us to estimate that an inhaled 1.0 μm diameter olivine particle would take approximately 24 years to dissolve in the human lungs and approximately 3 weeks to dissolve in gastric fluid. Results revealed that inhaled olivine particles may generate the toxic chemical, hydroxyl radical, for up to 5–6 days in lung fluid. Olivine dissolved in 0.1 M HCl for 2 weeks transformed to an amorphous silica-rich solid plus the ferric iron oxy-hydroxide ferrihydrite. Olivine dissolved in simulated lung fluid shows no detectable change in composition or crystallinity. Equilibrium thermodynamic models indicate that olivine in the human lungs can precipitate secondary minerals with fibrous crystal structures that have the potential to induce detrimental health effects similar to asbestos exposure. Our work indicates that inhaled lunar dust containing olivine can settle in the human lungs for years and could induce long-term potential health effects like that of silicosis.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Delayed coastal inundations caused by ocean dynamics post-Hurricane Matthew

Post Hurricane Abnormal Water Level (PHAWL) poses a persistent inundation threat to coastal communities, yet unresolved knowledge gaps exist regarding its spatiotemporal impacts and causal mechanisms. Using a high-resolution coastal model with a set of observations, we find that the PHAWLs are up to 50 cm higher than the normal water levels for several weeks and cause delayed inundations around residential areas of the U.S. Southeast Coast (USSC). Numerical experiments reveal that while atmospheric forcing modulates the coastal PHAWLs, ocean dynamics primarily driven by the Gulf Stream control the mean component and duration of the shelf-scale PHAWLs. Because of the large spatial impact of the post-hurricane oceanic forcing, the coastal hazards are not limited to a direct hit from a hurricane but can be detected throughout the USSC where the oceanic processes reach.

54 ENVIRONMENTAL SCIENCES↗

MSW Variability Mapping and Conversion to Biofuel

MSW (Municipal Solid Waste) is a form of biomass which consists of categorized components of waste/trash. The general categories are paper, yard trash, construction & debris, appliances, tires, glass, metals, aluminum & steel cans, plastics, organics, inorganics, and HHW (Household Hazardous Waste). This project focuses on the factors within a region or population that contribute to variability in the composition of MSW and in turn MSW’s convertibility to biofuel. A list of contributors was determined (Social Vulnerability Index, Access to Public Transportation, Racial Distribution, GDP, Personal Income) and then JMP was used to perform a Multivariate analysis to determine correlations and a Partial Least-Squares regression to determine Variable Importance Plots for each MSW category. In addition to data analysis, the convertibility of MSW to biofuel was studied via microwave pyrolysis system in order to separate and characterize the various gaseous and bio-oil products.

09 BIOMASS FUELS↗

Large-scale Hydrogen Storage – Risk Assessment Seattle City Light and Port of Seattle [Abstract]

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL), and the Port of Seattle (Port) in performing a risk assessment of large-scale hydrogen storage. Risk assessment is often used to ensure that adequate measures are taken to protect workers and the public, the environment, infrastructure, and assets. A detailed risk assessment can also be used to direct funding and upgrades, to specific components and sub-systems in order to mitigate risks to the larger system. In this way risk assessments are often employed as a part of a larger risk management strategy, with the goal of minimizing the occurrence of hazards and to identify means to limit their consequences. Risk assessment is often used to engage and inform regulators, and to communicate how specific regulations are being met. However, it is important to note that the proposed work is not intended for SCL and the Port to use in order to gain regulatory acceptance for their proposed activities. The work performed as a part of this effort will be a preliminary risk assessment for early-stage component and system designs and should be considered research and development (R&D). As such, the proposed work will be performed to a quality level and design maturity consistent with R&D and is not considered appropriate for final safety analysis and regulatory compliance purposes. Previous and on-going work at SCL and the Port demonstrated the utility of deploying hydrogen systems at the Port. The deployment of hydrogen at the Port is a part of a larger vision of using hydrogen to address a range of issues for SCL and the Port. These include large-scale fueling of MD/HD vehicles, cargo-handling equipment (CHE), and harbor vessels to reduce emissions; support of adjacent LD vehicles; support of critical port operations during extreme events (i.e., resiliency); deferral of more capital- and time-intensive electrical distribution system upgrades while still supporting evolving port operations and decarbonization efforts; facilitating electrification by establishing energy storage as a grid resource, starting at strategic port locations; creation of a flexible market resource that can be used by SCL to generate revenue via arbitrage; support of planned future maritime operations that involve heavy use of hydrogen for ocean-going vessels; and future end-use applications involving natural gas pipeline hydrogen injection. Ultimately, the success of these activities is underpinned by the deployed storage capacity. Large-scale deployment of hydrogen systems will require hydrogen storage at a scale that has not been demonstrated. In addition, the ideal location for such multi-use systems is near the end user which will often necessitate deploying into urban and/or industrial areas. A detailed risk assessment using the Port as a test case is necessary to ensure the deployment of large-scale hydrogen is successful. Many technologies have been proposed for hydrogen storage; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for the Port will be analyzed, and a risk assessment for compressed hydrogen, liquified hydrogen, and Liquid Organic Hydrogen Carrier (LOHC) storage will be performed. These risk assessments will be useful for understanding how each of these technologies would perform in terms of facility and public safety. The operating states of the proposed hydrogen systems at the Port will be analyzed and incorporated into the storage risk assessment. Scalability will also be analyzed to understand how future port uses would affect the overall risk assessment. Finally, using the risk assessment as a tool to inform engagement and to gain stakeholder acceptance will be explored.

08 HYDROGEN↗

Elucidating the challenges in extracting ultra-slow flame speeds in a closed vessel - A CH 2 F 2 microgravity case study using optical and pressure-rise data

Refrigerants with a low global warming potential (GWP) possess mild flammability. Hence, a fundamental understanding of their combustion characteristics is required to assess their fire-hazardous potential. The laminar burning velocity is one fundamental property to describe these under safety evaluation aspects. However, measuring laminar burning velocities for slow-burning components, such as low-GWP alternatives, is challenging. This is due to influencing effects such as buoyant flame deformation, stretch, radiation, and confinement, especially at the flammability limits. Here, in the present study, we investigated near-limit flames of the representative refrigerant difluoromethane (CH 2 F 2 ) with nitrogen-enriched oxidizer mixtures to elucidate the potentials and limitations at ultra-slow flame speeds of two widely used flame speed measurement methods in the closed vessel configuration: the optical flame speed measurement in the early quasi-isobaric regime and the flame speed determination from the pressure-rise during the later phase of the isochoric combustion process. Experiments were performed under terrestrial- and microgravity, conducted in a specially designed setup suitable for drop tower applications, using both methods in parallel. Recommendations for the extraction of flame speed data are derived from the non-buoyant reference investigations under microgravity and transferred to ultra-slow flames at terrestrial gravity. Near-limit flames under microgravity were found to be significantly affected by stretch effects for the optical method so that flame speed extrapolations to unstretched conditions are prone to errors. Stretch also affects the pressure method’s lower evaluation limit, and errors can be estimated by combining flame speed data from the pressure method and Markstein lengths from optical experiments.

42 ENGINEERING↗

Synthetic Atmospheric River Ensembles Generated by Deep-AR

This dataset contains 35,850 synthetic landfalling atmospheric river (AR) realizations generated by the Deep-AR two-stage deep-learning framework over the Northeast Pacific and U.S. West Coast. The archive contains 25 stochastic ensemble members for each of 1,434 held-out observed seed events. Each synthetic realization is initialized from conditions 48 hours before the corresponding observed AR landfall and is generated autoregressively at 6-hour intervals over a 144-hour period. Deep-AR combines a deterministic residual network (ResNet) that advances the large-scale atmospheric state with a Wasserstein generative adversarial network (WGAN) that produces stochastic, high-resolution fields. Each HDF5 file contains 0.25° gridded synthetic integrated vapor transport components (qu, qv), 10 m wind components (u10, v10), and 6-hour accumulated precipitation on a common 200 × 480 grid. The files also include coordinate and datetime arrays. This dataset supports AR hazard analysis, ensemble-based uncertainty characterization, precipitation-extremes research, and regional stress testing. Synthetic files follow the naming convention deepar.model.YYYYMMDD.HHMMSS.vNN.h5. YYYYMMDD.HHMMSS identifies the UTC initial-condition timestamp, which occurs 48 hours before the diagnosed observed landfall, and vNN identifies the zero-padded ensemble member, ranging from v01 through v25. Each synthetic file can be paired with its corresponding observed file by matching the initial-condition timestamp. The paired observed file follows the naming convention deepar.obs.YYYYMMDD.HHMMSS.h5 and is available in the separately registered oracle/deepar.obs dataset at https://wdh.energy.gov/ds/oracle/deepar.obs (DOI: https://doi.org/10.21947/3377671).

17 WIND ENERGY↗

Robotic Mapping and Monitoring of Nuclear Infrastructure

Routine inspection of nuclear infrastructure is currently expensive and slow. To remedy this the Applied Research Center (ARC) at Florida International University (FIU) is developing a field robot capable of gathering valuable data quickly, safely, and cheaply. Motivation: Nuclear infrastructure should be inspected routinely to ensure early detection of problems. This process is expensive, hazardous, and slow. Objective: Develop a platform capable of surveying nuclear infrastructure autonomously. Discussion: The quality of the captured data depends on the success of every component of the robot. Good sensors, hardware, localization, data collection, and autonomy are required. Conclusion: This is a promising approach for surveying nuclear infrastructure. The captured data is rich with information and can be evaluated by both people and algorithms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Physics and technology considerations for the deuterium–tritium fuel cycle and conditions for tritium fuel self sufficiency

The tritium aspects of the DT fuel cycle embody some of the most challenging feasibility and attractiveness issues in the development of fusion systems. The review and analyses in this paper provide important information to understand and quantify these challenges and to define the phase space of plasma physics and fusion technology parameters and features that must guide a serious R&D in the world fusion program. We focus in particular on components, issues and R&D necessary to satisfy three 'principal requirements': (1) achieving tritium self-sufficiency within the fusion system, (2) providing a tritium inventory for the initial start-up of a fusion facility, and (3) managing the safety and biological hazards of tritium. A primary conclusion is that the physics and technology state-of-the-art will not enable DEMO and future power plants to satisfy these principal requirements. We quantify goals and define specific areas and ideas for physics and technology R&D to meet these requirements. A powerful fuel cycle dynamics model was developed to calculate time-dependent tritium inventories and flow rates in all parts and components of the fuel cycle for different ranges of parameters and physics and technology conditions. Dynamics modeling analyses show that the key parameters affecting tritium inventories, tritium start-up inventory, and tritium self-sufficiency are the tritium burn fraction in the plasma (f b ), fueling efficiency (η f ), processing time of plasma exhaust in the inner fuel cycle (t p ), reactor availability factor (AF), reserve time (tr) which determines the reserve tritium inventory needed in the storage system in order to keep the plant operational for time t r in case of any malfunction of any part of the tritium processing system, and the doubling time (t d ). Results show that η f f b > 2% and processing time of 1–4 h are required to achieve tritium self-sufficiency with reasonable confidence. For η f f b = 2% and processing time of 4 h, the tritium start-up inventory required for a 3 GW fusion reactor is ~11 kg, while it is <5 kg if η f f b = 5% and the processing time is 1 h. To achieve these stringent requirements, a serious R&D program in physics and technology is necessary. The EU-DEMO direct internal recycling concept that carries fuel directly from the plasma exhaust gas to the fueling systems without going through the isotope separation system reduces the overall processing time and tritium inventories and has positive effects on the required tritium breeding ratio (TBR R ). A significant finding is the strong dependence of tritium self-sufficiency on the reactor availability factor. Simulations show that tritium self-sufficiency is: impossible if AF < 10% for any η f f b , possible if AF > 30% and 1% ≤ η f f b ≤ 2%, and achievable with reasonable confidence if AF > 50% and η f f b > 2%. These results are of particular concern in light of the low availability factor predicted for the near-term plasma-based experimental facilities (e.g. FNSF, VNS, CTF), and can have repercussions on tritium economy in DEMO reactors as well, unless significant advancements in RAMI are made. There is a linear dependency between the tritium start-up inventory and the fusion power. The required tritium start-up inventory for a fusion facility of 100 MW fusion power is as small as 1 kg. Since fusion power plants will have large powers for better economics, it is important to maintain a 'reserve' tritium inventory in the tritium storage system to continue to fuel the plasma and avoid plant shutdown in case of malfunctions of some parts of the tritium processing lines. But our results show that a reserve time as short as 24 h leads to unacceptable reserve and start-up inventory requirements. Therefore, high reliability and fast maintainability of all components in the fuel cycle are necessary in order to avoid the need for storing reserve tritium inventory sufficient for continued fusion facility operation for more than a few hours. The physics aspects of plasma fueling, tritium burn fraction, and particle and power exhaust are highly interrelated and complex, and predictions for DEMO and power reactors are highly uncertain because of lack of experiments with burning plasma. Fueling by pellet injection on the high field side of tokamak has evolved to be the preferred method to fuel a burning plasma. Extrapolation from the DIII-D penetration scaling shows fueling efficiency expected in DEMO to be <25%, but such extrapolations are highly uncertain. The fueling efficiency of gas in a reactor relevant regime is expected to be extremely poor and not very useful for getting tritium into the core plasma efficiently. Gas fueling will nonetheless be useful for feedback control of the divertor operating parameters. Extensive modeling has been carried out to predict burn fraction, fueling requirements, and fueling efficiency for ITER, DEMO, and beyond. The fueling rate required to operate Q = 10 ITER plasmas in order to provide the required core fueling, helium exhaust and radiative divertor plasma conditions for acceptable divertor power loads was calculated. If this fueling is performed with a 50–50 DT mix, the tritium burn fraction in ITER would be ~0.36%, which is too low to satisfy the self-sufficiency conditions derived from the dynamics modeling for fusion reactors. Extrapolation to DEMO using this approach would also yield similarly low burn fraction. Extensive analysis presented shows that specific features of edge neutral dynamics in ITER and fusion reactors, which are different from present experiments, open possibilities for optimization of tritium fueling and thus to improve the burn fraction. Using only tritium in pellet fueling of the plasma core, and only deuterium for edge density, divertor power load and ELM control results in significant increase of the burn fraction to 1.8–3.6%. These estimates are performed with physics models whose results cannot be fully validated for ITER and DEMO plasma conditions since these cannot be achieved in present tokamak experiments. Thus, several uncertainties remain regarding particle transport and scenario requirements in ITER and DEMO. The safety standard requirements for protection of the public and release guidelines for tritium have been reviewed. General safety approaches including minimizing tritium inventories, reducing tritium permeation through materials, and decontaminating material for waste disposal have been suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of elevated temperature and oxygen on the capture of radioactive iodine by silver functionalized silica aerogel

Reprocessing is considered a competent strategy for spent nuclear fuel management, yet radioiodine ( 129 I) is emitted in reprocessing off-gas as a hazardous byproduct. Silver functionalized silica aerogel (Ag 0 -aerogel), a promising iodine capture material, experiences a reduction in its capacity after prolonged exposure to off-gas components at elevated temperatures, a phenomenon termed as aging. To fully understand this process, we isolated the contribution of each aging factor, exposing Ag 0 -aerogel samples to N 2 and dry air gas streams, respectively, at 150 °C for different time periods. Aged samples were loaded with I 2 to examine the capacity change and comprehensively characterized to investigate the evolution of their properties. Results show that temperature alone did not alter Ag 0 -aerogel's capacity but triggered Ag 0 nanoparticles sintering and generated organic sulfur species. The presence of O 2 reduced the capacity by ~20 %, causing (i) formation of silver sulfide (Ag 2 S) crystals and (ii) oxidation of Ag-thiolate (Ag-S-r) to Ag sulfonate (Ag-SO 3 -r). Given that Ag 2 S readily adsorbs I 2 , the formation of Ag-SO 3 -r is the major inhibitor for iodine adsorption. This hypothesis was supported by density functional theory (DFT) simulations. These findings unraveled key mechanisms of Ag 0 -aerogel aging, which are useful in the development of materials that withstand realistic spent-nuclear-fuel-reprocessing off-gas conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗