Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat sink”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Short-range thermal magnon diffusion in magnetic garnet

Here, using the spin Seebeck effect (SSE), we study the propagation distance of thermally induced spin currents inside a magnetic insulator thin film in the short-range regime. We disambiguate spin currents driven by temperature and chemical potential gradients by comparing the SSE signal before and after adding a heat-sinking capping layer on the same device. We report that the measured spin decay behavior near the heat source is well accounted for by a diffusion model where the magnon diffusion length is in submicron range, in other words, two orders of magnitude smaller than previous estimates inferred from the long-range behavior. Our results highlight the caveat in applying a diffusive theory to describe thermally generated magnon transport, where a single decay length may not capture the behavior on all length scales.

36 MATERIALS SCIENCE↗

Effect of cold cap coverage and emissivity on the plenum temperature in a pilot-scale waste vitrification melter

Integrated computational fluid dynamics (CFD) models are being developed to model the complex physics occurring within the high-level waste melter for vitrification of legacy tank waste at the Hanford site. Here, we present a validation of the integrated CFD model by using data from two experimental runs in a pilot-scale melter. While the model uses several simplifying assumptions (such as constant heat sinks from a cooling jacket and inleakage of ambient air, steady state feed-to-batch conversion heat, and a cold cap model with a simplified shape), it closely predicts the molten glass (1150°C and 1175°C) and plenum temperatures (550°C) obtained from thermocouples during two pilot-scale tests, with an average cold cap coverage of 80%. Additional simulations were performed to explore the sensitivity of the predicted plenum temperatures to variations in cold cap coverage (fraction of melt surface covered by the glass batch) and batch emissivity. The plenum temperature was found to be in the range of 606°C when cold cap coverage decreased from 95% to 70%. Cold cap emissivity had a smaller effect, increasing the plenum temperature by as much as 179°C when cold cap emissivity increased from 0.2 to 0.8. Maintaining a high cold cap coverage without overfeeding is important for a sustained melter operation with high glass throughput. This work provides a tool for achieving that goal in terms of correlating the plenum temperature with the cold cap coverage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Heating assemblies, heat exchange assemblies, methods for providing and/or exchanging heat, turbine combustion engines, and methods for powering turbine combustion engines

Heat exchanger assemblies and methods for providing heat exchange as well as methods providing specific energy to predetermined materials within an assembly as well as gas turbine engines as well as methods of powering same are provided. Heating assemblies are provided that can include: a heat-sinking substrate; and a selective emitter layer in thermal communication with the substrate. These assemblies can be provided as part of heat exchanger assemblies. Methods for providing heat to a fluid are also provided that can include heating a layer upon a substrate to provide photons of a predetermined wavelength to a fluid from the layer.Turbine combustion engines are also provided that can include a turbine having at least a portion of the blades in the hot section of the turbine coated with an emissivity layer in thermal communication with the turbine blade. Methods for powering turbine combustion engines are also provided.

McGrail, B. Peter↗

Dual‐Functional High‐Entropy Polymer Exhibiting Giant Cross‐Energy Couplings at Low Fields

A key component of cooling devices is the transfer of entropy from the cold load to heat sink. An electrocaloric (EC) polymer capable of generating both large electrocaloric effect (ECE) and substantial electroactuation can enable EC cooling devices to pump heat without external mechanisms, resulting in compact designs and enhanced efficiency. However, achieving both high ECE and significant electroactuation remains challenging. Herein, it is demonstrated that poly(vinylidene fluoride‐trifluoroethylene‐chlorofluoroethylene‐double bond) [P(VDF‐TrFE‐CFE‐DB)] tetrapolymers can simultaneously generate high electrocaloric effects and electroactuations under low fields. These P(VDF‐TrFE‐CFE‐DB) tetrapolymers are synthesized through the dehydrochlorination of P(VDF‐TrFE‐CFE) terpolymer. By facile tuning the composition of the initial terpolymer to avoid pure relaxor state, tetrapolymers with optimal DB compositions are achieved, near the critical endpoint of normal ferroelectric phase with diffused phase transition. The nearly vanishing energy barriers between the nonpolar to polar phases result in a strong electrocaloric response and significant electroactuation. Specifically, the P(VDF‐TrFE‐CFE‐DB) tetrapolymer exhibits an EC entropy change Δ S of 100 J kg −1 K −1 under 100 MV m −1 : comparable to state‐of‐the‐art (SOA) EC polymers, while delivering nearly twice the electroactuation of the SOA EC polymers. This work presents a general strategy for developing EC materials that combine large electrocaloric effect and electroactuation at low electric fields.

36 MATERIALS SCIENCE↗

Computational Fluid Dynamics and Heat Transfer Modeling of a Dimpled Heat Exchanger

Multiphysics and analytical calculations were conducted for a heat exchanger with passive, natural circulation flow. A glycol/water working fluid convects the heat to a dimpled heat exchanger shell, which subsequently transfers the heat to the soil, which acts as the ultimate heat sink. Because the system is fully-passive, it is not subject to the expenses, maintenance, and mechanical breakdowns associated with moving parts. Density, heat capacity, and thermal conductivity material properties were measured for various soil samples, and subsequently included as input for the soil heat conduction model. The soil model was coupled to a computational fluid dynamics (CFD) heat exchanger model that included the dynamic Smagorinsky large eddy simulation and k- omega turbulence models. The analysis showed that the fluid dynamics and heat transfer models worked properly, albeit at a slow pace. Nevertheless, the coupled CFD/heat conduction simulation ran long enough to determine a key parameter—the amount of heat conducted from the heat exchanger to the ground. This unique performance value, along with experimental data, was used as input for stand-alone, fast-running CFD models, as well as boundaries to obtain solutions to partial differential equations for soil heat conduction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Magnesium Oxysulfate Formulation for SRPPF Aqueous Recovery Liquid Solidification

The liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery Processes will be solidified into a stable form that is acceptable by Waste Isolation Pilot Plant (WIPP) for disposal. The current Aqueous Recovery flow sheet proposes to solidify the liquid effluent using a grout formula that was developed and tested for the former Waste Solidification Building process. This Portland cement based mixture results in a high pH (~13) leachate from the solidified waste form which is not acceptable to WIPP in the large quantities expected from production at SRPPF. Various cementitious materials were previously evaluated as alternative grout formulations to Portland cement and a MgO-based mix was identified as a promising alternative. A magnesium oxysulfate (MOS) cement formulation comprised of reactive magnesium oxide (MgO), anhydrous magnesium sulfate (MgSO 4 ), and sand, as a non-reactive heat sink provided good mixability, similar density to the original Portland-cement based mix, and a leachate pH of 9.4, within the assumed WIPP brine pH range. However, the MOS formulation exhibited an appreciable amount of heat generation, which resulted in premature setting of a large-scale test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Catalytic Enhancement of Inductively Heated Fe 3 O 4 Nanoparticles by Removal of Surface Ligands

Abstract Heat management in catalysis is limited by each material's heat transfer efficiencies, resulting in energy losses despite current thermal engineering strategies. In contrast, induction heating of magnetic nanoparticles (NPs) generates heat at the surface of the catalyst where the reaction occurs, reducing waste heat via dissipation. However, the synthesis of magnetic NPs with optimal heat generation requires interfacial ligands, such as oleic acid, which act as heat sinks. Surface treatments using tetramethylammonium hydroxide (TMAOH) or pyridine are used to remove these ligands before applications in hydrophilic media. In this study, Fe 3 O 4 NPs are surface treated to study the effect of induction heating on the catalytic oxidation of 1‐octanol. Whereas TMAOH was unsuccessful in removing oleic acid, pyridine treatment resulted in a roughly 2.5‐fold increase in heat generation and product yield. Therefore, efficient surfactant removal has profound implications in induction heating catalysis by increasing the heat transfer and available surface sites.

Moura, Natalia S.↗

Evaluation of the DC bus link capacitors and power transistor modules in the qualification testing of PV inverters

To achieve useful, fair, and cost-effective design qualification and type approval testing for PV inverters, two procedures were developed and demonstrated to evaluate the bus link capacitors and power transistor—and where applicable, its module—for long-term reliability. We evaluate the inverter under simulated use conditions with heat run tests to find the highest operating temperatures reached by these components. The procedures are demonstrated in this study with a 4-kVA class string inverter. The maximum temperature of the DC bus link capacitors was determined to be 76.4°C when the ambient temperature was at the inverter's maximum rated temperature of 60°C with derating occurring. On the other hand, the power transistor module's maximum temperature using the heat sink temperature as the index, 92.6°C, occurred in an ambient of 40.8°C when derating was not occurring. The conditions found for upper temperatures exhibited by these components are, respectively, proposed for implementation in the dry heat and thermal cycling tests in the IEC 62093 “Power conversion equipment for photovoltaic systems – Design qualification testing” international standard draft so that the levels applied in the tests are in proportion to those experienced in the field. Finally as a result, fairer evaluation of inverter reliability is realized.

14 SOLAR ENERGY↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

The reservoir network: A new network topology for district heating and cooling

Thermal district networks are effective solutions to substitute fossil fuels with renewable energy sources for heating and cooling. Moreover, thermal networking of buildings allows energy efficiency to be further increased. The waste heat from cooling can be reused for heating in thermal district systems. Because of bidirectional energy flows between prosumers, thermal networks require new hydraulic concepts. In this work, we present a novel network topology for simultaneous heating and cooling: the reservoir network. The reservoir network is robust in operation due to hydraulic decoupling of transfer stations, integrates heat sources and heat sinks at various temperature levels and is flexible in terms of network expansion. Furthermore, we used Modelica simulations to compare the new single-pipe reservoir network to a basecase double-pipe network, taking yearly demand profiles of different building types for heating and cooling. The electric energy consumed by the heat pumps and circulations pumps differs between the reservoir and base case networks by less than 1%. However, if the reservoir network is operated with constant instead of variable mass flow rate, the total electrical consumption can increase by 48% compared to the base case. As with any other network topology, the design and control of such networks is crucial to achieving energy efficient operation. Investment costs for piping and trenching depend on the district layout and dimensioning of the network. If a ring layout is applied in a district, the reservoir network with its single-pipe configuration is more economical than other topologies. For a linear layout, the piping costs are slightly higher for the reservoir network than for the base case because of larger pipe diameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature-adaptive radiative coating for all-season household thermal regulation

The sky is a natural heat sink that has been extensively used for passive radiative cooling of households. A lot of focus has been on maximizing the radiative cooling power of roof coating in the hot daytime using static, cooling-optimized material properties. However, the resultant overcooling in cold night or winter times exacerbates the heating cost, especially in climates where heating dominates energy consumption. In this work, we approached thermal regulation from an all-season perspective by developing a mechanically flexible coating that adapts its thermal emittance to different ambient temperatures. The fabricated temperature-adaptive radiative coating (TARC) optimally absorbs the solar energy and automatically switches thermal emittance from 0.20 for ambient temperatures lower than 15°C to 0.90 for temperatures above 30°C, driven by a photonically amplified metal-insulator transition. Simulations show that this system outperforms existing roof coatings for energy saving in most climates, especially those with substantial seasonal variations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Modified DBC Substrate Improving Thermal Performance for Confined Space Applications

High-power modules use substrates to house the semiconductor device and for electrical insulation. These substrates are constructed with thermally conductive dielectric material sandwiched between two metals to extract heat from semiconductor chips. Thus, the required cooling performance of a power module is linked to the substrate’s thermal performance and can vary based on the substrate technologies. Here, in this study, five substrate technologies were evaluated for space-restricted applications: direct-bonded copper (DBC), an insulated metal substrate (IMS), a thermally annealed pyrolytic graphite (TPG)-based IMS, DBC-based double-sided cooling, and direct-bonded aluminum (DBA) where the heat sink is directly attached without thermal interface materials (TIMs). The finite element (FE) analysis results suggest that the popular DBC substrate has thermal performance better than that of the other substrates for space-constrained applications. To further improve the thermal performance, a modified DBC substrate was proposed where a copper block was added between the semiconductor and the DBC substrate to achieve heat spreading underneath the chip. The modified DBC performance was then compared with the aforementioned substrates and the results showed significant thermal performance improvement. The results were verified with experimental results where the proposed substrate showed 20% more loss handling capability compared to an identical DBC substrate.

42 ENGINEERING↗

Superconducting coherence peak in near-field radiative heat transfer

Enhancement and peaks in near-field radiative heat transfer (NFRHT) typically arise due to surface phonon-polaritons, plasmon-polaritons, and electromagnetic (EM) modes in structured materials. However, the role of material quantum coherence in enhancing near-field radiative heat transfer remains unexplored. Here, we unravel that NFRHT in superconductor-ferromagnetic systems displays a unique peak at the superconducting phase transition that originates from the quantum coherence of Bogoliubov quasiparticles in superconductors. Our theory takes into account evanescent EM radiation emanating from fluctuating currents related to Cooper pairs and Bogoliubov quasiparticles in stark contrast to the current-current correlations induced by free electrons in conventional materials. Our proposed NFRHT configuration exploits ferromagnetic resonance at frequencies deep inside the superconducting band gap to isolate this superconducting coherence peak. Furthermore, we reveal that Cooper pairs and Bogoliubov quasiparticles have opposite effects on near-field thermal radiation and isolate their effects on many-body radiative heat transfer near superconductors. As a result, our proposed phenomenon can have applications for developing thermal isolators and heat sinks in superconducting circuits.

Dipole approximation↗

Material Plasma Exposure eXperiment High Heat Flux Microwave Absorber Design, Manufacture, and Articles Test

The Material Plasma Exposure eXperiment (MPEX) at Oak Ridge National Laboratory is in the final design phase. MPEX will be capable of exposing neutron-irradiated materials to plasmas for the study of plasma-material interaction. This facility will provide information about the complex effects of plasmas on materials and contribute to examining new materials that can withstand high heat fluxes and high ion fluences for future fusion devices. MPEX plasma is heated by 70-GHz or 105-GHz electron Bernstein wave/electron cyclotron heating (ECH), and the high-frequency microwaves are prone to scattering microwave power, which can have detrimental effects, especially on diagnostic components. A large portion of the injected ECH power is expected to be absorbed by plasma, but the remainder requires that microwave absorbers be placed immediately upstream and downstream of the ECH launcher to minimize stray microwaves leaving the ECH region. These microwaves can inadvertently heat components that cannot be shielded or otherwise protected. The microwave absorber design is based on an array of pyramid-shaped ceramic tiles brazed to a water-cooled explosion-bonded heat sink and a stainless steel plate to produce one tile module. Computational fluid dynamics and structural analyses were performed to optimize and validate the design. Multiple test coupons were produced to validate the process for brazing the two different tile materials to the Glidcop AL-15 baseplate. The articles were tested to evaluate the reliability and thermal performance through exposure to an electron beam with a heat flux of up to 1.5 MW/m2. Nondestructive testing was performed before and after testing to identify voids or separations that may have been introduced by the high heat flux. This paper discusses the details of high heat flux microwave absorber design, manufacturing details and associated challenges, and test results, demonstrating the effectiveness of the proposed design.

Hussain, Aftab↗