Search NASA⌕ Search

SEARCH · Search NASA

Results for “helium bubble”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hollow Spheres of Metallic Glass

Uniform hollow spheres of gold/lead/antimony glass formed by blowing bubbles of molten metal into helium-filled drop tube. Useful in fusion target applications.

Lee, M. C.↗

A Report on Superfluid Helium Flow Through Porous Plugs for Space Science Applications

As a background for the study of the nature of superfluid helium flow through porous plugs for other space science uses, preliminary tests on various plugs of a given material, diameter, height, and filtration grade have been performed. Two characteristics of the plugs, pore size and number of channels, have been determined by the bubble test and warm flow test of helium gas through the plugs, respectively. Tests on the flow of He II through the plugs have also been performed. An obvious feature of the results of these tests is that for isothermal measurements of pressure versus mass flow rate below approximately 2.10 K, the flow is separated into two different regimes, indicative of the occurrence of a critical phenomenon.

Mason, F. C.↗

First spectral observations of the diffuse background with the Extreme Ultraviolet Explorer

We present the first results from the analysis of the spectroscopic observations of diffuse extreme ultraviolet (EUV) emission taken with the Extreme Ultraviolet Explorer (EUVE) spectrometers in the wavelength range 160-740 A. Although not designed or optimized for diffuse observation, the EUVE spectrometers are the most sensitive diffuse EUV spectrometer in orbit. The spectral resolution for diffuse emission of the medium and long-wavelength spectrometers are 17 and 34 A FWHM, respectively. During the period from 1992 July 25 to 1992 August 19, the spectrometers surveyed a 2 x 20 deg field scanned from (l, b) = (24 deg, -28 deg) to (44 deg, -74 deg) with a total effective exposure time of 575,232 s. The only emission lines detected were those of He I and He II (584, 537, 304 A) with intensities consistent with local geocoronal and/or interplanetary scattering of solar radiation (584 A = 1.30 rayleighs; 537 A = 0.040 R; and 304 A = 0.029 R). Models of the soft X-ray background, which results from a 10(exp 6) K plasma (Local Bubble) surrounding the neutral gas near the Sun (Local Cloud), predict that most of the flux from the hot plasma appears as emission lines in the EUV. We have compared these spectral predictions with our observations to place limits on the emission measure versus temperature of the proposed hot plasma. Using the same plasma model, we derived emissions measures for our data and the C and B soft X-ray bands of the Wisconsin rocket survey. We find that our limits for the plasma emission measure are a factor of 5-10 below the C- and B-band emission measures over the temperature range from 10(exp 5.7) to 10(exp 6.4) K. We explore possible scenarios that could reconcile our results with the X-ray surveys and conclude that depletion or a nonequilibrium plasma state rather than absorption are the more likely explanations of the discrepancy. We also show that our spectrum is inconsistent with the spectrum from the approximately 10(exp 5) K gas at the conductive interface between the hot Local Bubble and the cooler Local Cloud given by Slavin (1989). In addition, we place new limits on the helium ionization parameter in the Sun's vicinity caused by the 10(exp 6) K plasma in the Local Bubble.

Jelinksy, P.↗

Acoustic velocities of two-phase mixtures of cryogenic fluids

Calculated values of the acoustic velocity are presented for single-component and two-component, two-phase mixtures. Three different analytic models were employed. For purposes of comparison, all three models were used in making acoustic-velocity calculations for single-component, equivalent bubbly two-phase mixtures (with insoluble gas) of oxygen and helium and hydrogen and helium. In all cases the results are shown graphically so that the effects of variation in quality or void fraction, temperature and pressure are illustrated.

Griggs, E. I.↗

Iron, Cobalt, and Nickel in SN 1987A

During the first several weeks after the explosion of SN 1987A, Fe/Co/Ni clumps, containing approx. 1% of the mass of the supernova envelope, absorbed most of the energy release by Ni-56 and Co-56 decay. As a result, the clumps expanded relative to the substrate, forming a 'nickel bubble' of low-density Fe/Co/Ni. Later the clumps captured approx. 10% of the radioactive luminosity of gamma rays and positrons. Assuming that these elements are not mixed microscopically with other elements, we find that the clumps must occupy approx. greater than 30% of the volume of the emitting region (radial velocity approx. less than 2500 km/s). The result indicates that the emission at late times is dominated by an extra source of heating and ionization, most likely photoionization by two-photon continuum from metastable helium in the gas surrounding the clumps. The resulting 'frothy' structure, consisting of bubbles of low-density Fe surrounded by higher-density filaments of H, He, and other elements, will persist and may be seen in the spectra and structure of supernova remnants.

Li, Hongwei↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 - 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

Hartwig, Jason↗

Bag Test Measures Leakage From Insulated Pipe

Test quantifies leakage of gas from pipe even though pipe covered with insulation. Involves use of helium analyzer to measure concentration of helium in impermeable bag around pipe. Test administered after standard soap-solution bubble test indicates presence and general class of leakage.

Schock, Kent D.↗

Investigation of bubbles in arterial heat pipes

The behavior of gas occlusions in arterial heat pipes has been studied experimentally and theoretically. Specifically, the gas-liquid system properties, solubility and diffusivity, have been measured from -50 to 100 C for helium and argon in ammonia, Freon-21 (CHC12F), and methanol. Properties values obtained were then used to experimentally test models for gas venting from a heat pipe artery under isothermal conditions (i.e., no-heat flow), although the models, as developed, are also applicable to heat pipes operated at power, with some minor modifications. Preliminary calculations indicated arterial bubbles in a stagnant pipe require from minutes to days to collapse and vent. It has been found experimentally that a gas bubble entrapped within an artery structure has a very long lifetime in many credible situations. This lifetime has an approximately inverse exponential dependence on temperature, and is generally considerably longer for helium than for argon. The models postulated for venting under static conditions were in general quantitative agreement with experimental data. Factors of primary importance in governing bubble stability are artery diameter, artery wall thickness, noncondensible gas partial pressure, and the property group (the Ostwald solubility coefficient multiplied by the gas/liquid diffusivity).

Saaski, E. W.↗

Design and evaluation of thermodynamic vent/screen baffle cryogenic storage system

A comprehensive analytical program was performed to compare an integrated thermodynamic vent/screen baffle orbital cryogenic propellant storage and transfer system with other concepts. The screen systems were found to be 20% to 29% lighter in weight than a propulsively accelerated Tug-scale LH2/LO2 resupply module. The screen systems were compared with small-scale supercritical storage systems for the space shuttle fuel cell reactant and life support system fluid supply and were lighter by up to 556 kg (1225 lb) for the extended 30-day mission. When compared with high-pressure gas storage for the spacelab atmosphere supply, the screen system saved 79% of the inert system weight for the 30-day mission. An experimental program found that heat flux rates up to 9,450 watts/sq m (3,000 Btu/hr-sq ft) degraded the LH2 bubble point performance of eight screens by a maximum of 12.5%. No effects of helium pressurant, screen material, or LH2 superheat were observed.

Cady, E. C.↗

Photographic Study of Liquid-Oxygen Boiling and Gas Injection in the Injector of a Chugging Rocket Engine

High-speed motion pictures were taken of conditions in the injector liquid-oxygen cavity of an RL-10 rocket engine during throttled engine operation. Photographs were taken during operation of the engine in the chugging region as the helium gas was injected to stabilize combustion, during operation at rated thrust, and during transition into chugging conditions as the gas injection was discontinued. Results of the investigation indicate that, during chugging rocket operation of the RL-10 engine, a high population of fairly large bubbles formed and collapsed within the liquid-oxygen cavity at the same frequency as the chamber pressure oscillations. When gaseous helium was injected into the liquid-oxygen cavity, a fog rapidly spread over the entire field of view, and the system immediately became stable. The injection of gaseous helium at rated conditions produced a very slight increase in engine performance but not enough to produce a net gain in a typical mission payload with the extra equipment needed. The inherent low-frequency system instability associated with the fuel system at low thrust levels was reduced by injecting either gaseous helium or hydrogen. Complete stabilization was achieved in some cases, and a reduction in the severity of the oscillations in others. This was apparently due to the ·anchoring of the phase change front to the location of the gas injection.

Conrad, E. William↗

A new gas lesion syndrome in man, induced by 'isobaric gas counterdiffusion'

Normal men have been found to develop pruritis and gas bubble lesions in the skin, and disruption of vestibular function, when breathing nitrogen or neon with oxygen while surrounded by helium at increased ambient pressure. This phenomenon, which occurs at stable ambient pressures, at 1 or many ATA, has been designated the isobaric gas counterdiffusion syndrome. In a series of analyses and experiments in vivo and in vitro the cause of the syndrome has been established as due to gas accumulation and development of gas bubbles in tissues as a result of differences in selective diffusivities, for various respired and ambient gases, in the tissue substances between capillary blood and the surrounding atmosphere. The phenomenon described in man is an initial stage of a process shown later in animals to progress to continuous, massive, lethal, intravascular gas embolization.

Lambertsen, C. J.↗

Is xenon eldest?

It is well known that the solubility of noble gases in magmas decreases with increasing atomic weight. Xenon, the weightiest of the stable noble gases, is the least soluble atmospheric gas in magma. It is not unreasonable to suppose that the noble gases should have degassed from (or equilibrated with) a bubbling mantle in order of increasing solubility, such that xenon was the most rapidly degassed and helium the least. The apparent relative ages of the famous radiogenic noble gas isotopes agrees, at least qualitatively, with this premise. When atmospheric loss processes are assigned their proper place, several long-standing xenonological puzzles become added evidence for xenon's relative antiquity. Xenon being the afore-mentioned sense the oldest atmospheric gas, will have been most greatly subject to escape, be it impact-driven or EUV-driven. Nonradiogenic xenon's pronounced isotopic fractionation has already been attributed to escape; why it should be more fractionated than krypton would be assigned to xenon's greater atmospheric age. The small atmospheric inventory of xenon relative to the other nonradiogenic noblegases, known as the 'missing xenon' problem, could easily be explained by differential escape. The relatively tiny atmospheric inventories of the radiogenic daughter products of 129 Iodine and 244 Plutonium, both much smaller than would be expected from the inferred abundances of the parents in meteorites, offer a third and fourth data to support the hypothesis that Earth has lost most of its xenon.

Zahnle, K.↗

Warm Pressurant Gas Effects on the Static Bubble Point Pressure for Cryogenic LADs

This paper presents experimental results for the liquid hydrogen and nitrogen bubble point tests using warm pressurant gases conducted at the NASA Glenn Research Center. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device (LAD). Three fine mesh screen samples (325x2300, 450x2750, 510x3600) were tested in liquid hydrogen and liquid nitrogen using cold and warm non-condensable (gaseous helium) and condensable (gaseous hydrogen or nitrogen) pressurization schemes. Gases were conditioned from 0K - 90K above the liquid temperature. Results clearly indicate degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over non-condensable pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

Warm pressurant gas↗

Sloshing of Cryogenic Helium Driven by Lateral Impulse/Gravity Gradient-Dominated/or g-Jitter-Dominated Accelerations and Orbital Dynamics

The coupling of slosh dynamics within a partially filled rotating dewar of superfluid helium 11 with spacecraft orbital dynamics is investigated in response to the environmental disturbances of (a) lateral impulses, (b) gravity gradients and (c) g-jitter forces. The purpose of this study is to investigate how the coupling of helium 11 fluid slosh dynamics driven by three cases of environmental force with spacecraft dynamics can affect the bubble deformations and their associated fluid and spacecraft mass centre fluctuations. The numerical computation of slosh dynamics is based on a rotational frame, while the spacecraft dynamics is associated with a non-rotational frame. Results show that the major contribution of orbital dynamics is driven by coupling with slosh dynamics. Neglecting the effect of slosh dynamics acting on the spacecraft may lead to the wrong results for the development of orbital and attitude control techniques.

Hung, R. J.↗

Warm Pressurant Gas Effects on the Liquid Hydrogen Bubble Point

This paper presents experimental results for the liquid hydrogen bubble point tests using warm pressurant gases conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device. Three fine mesh screen samples (325 x 2300, 450 x 2750, 510 x 3600) were tested in liquid hydrogen using cold and warm noncondensible (gaseous helium) and condensable (gaseous hydrogen) pressurization schemes. Gases were conditioned from 0 to 90 K above the liquid temperature. Results clearly indicate a degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over noncondensible pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

Liquid Hydrogen↗

Handbook on Hypergolic Propellant Discharges and Disposal

The efficiency of all treatment methods formerly or currently used in treating chemical wastes is assessed with emphasis on the disposal of hypergolic propellants. Maximum focus is on the space shuttle propellants MMH and N2O4. Except for hydrogen peroxide oxidizers, all the propellants are nitrogen based and can be potentially reduced to valuable plant nutrients. In theory, all the propellants can be reduced to carbon, hydrogen, nitrogen, and oxygen, except of fuming nitric acid which contains a small amount of fluorine. Appendices cover: (1) a general design criteria for disposal ponds; (2) thermal aspects of reaction in dilute solution; (3) gas bubble growth, detachment, and rise (4) absorption scrubber fundamentals and descriptions; (5) separation of a propellant vapor from a helium stream by permeation; and (6) atmospheric emission limits.

Bowman, T. E.↗

Potential Fifty Percent Reduction in Saturation Diving Decompression Time Using a Combination of Intermittent Recompression and Exercise

Conventional saturation decompression protocols use linear decompression rates that become progressively slower at shallower depths, consistent with free gas phase control vs. dissolved gas elimination kinetics. If decompression is limited by control of free gas phase, linear decompression is an inefficient strategy. The NASA prebreathe reduction program demonstrated that exercise during O2 prebreathe resulted in a 50% reduction (2 h vs. 4 h) in the saturation decompression time from 14.7 to 4.3 psi and a significant reduction in decompression sickness (DCS: 0 vs. 23.7%). Combining exercise with intermittent recompression, which controls gas phase growth and eliminates supersaturation before exercising, may enable more efficient saturation decompression schedules. A tissue bubble dynamics model (TBDM) was used in conjunction with a NASA exercise prebreathe model (NEPM) that relates tissue inert gas exchange rate constants to exercise (ml O2/kg-min), to develop a schedule for decompression from helium saturation at 400 fsw. The models provide significant prediction (p < 0.001) and goodness of fit with 430 cases of DCS in 6437 laboratory dives for TBDM (p = 0.77) and with 22 cases of DCS in 159 altitude exposures for NEPM (p = 0.70). The models have also been used operationally in over 25,000 dives (TBDM) and 40 spacewalks (NEPM). The standard U.S. Navy (USN) linear saturation decompression schedule from saturation at 400 fsw required 114.5 h with a maximum Bubble Growth Index (BGI(sub max)) of 17.5. Decompression using intermittent recompression combined with two 10 min exercise periods (75% VO2 (sub peak)) per day required 54.25 h (BGI(sub max): 14.7). Combined intermittent recompression and exercise resulted in a theoretical 53% (2.5 day) reduction in decompression time and theoretically lower DCS risk compared to the standard USN decompression schedule. These results warrant future decompression trials to evaluate the efficacy of this approach.

Gernhardt, Michael I.↗