Search NASA⌕ Search

SEARCH · Search NASA

Results for “heterodyne detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Laser spectroscopic detection of air pollutants

A brief review is presented of the operating principles and applications of laser systems for monitoring pollution based on absorption spectroscopy. Particular consideration is given to an active bistatic system involving a cooperative reflector; an active monostatic system involving natural reflectors; an active monostatic system involving aerosol backscattering; and passive monostatic heterodyne detection.

Hinkley, E. D.↗

Infrared heterodyne spectroscopy for astrophysical applications

The paper reviews principles of laser heterodyne detection for sub-doppler spectroscopy of individual infrared spectral lines. State of the art capabilities are discussed and emphasis is placed on systems using semi-conductor diode lasers or CO2 lasers as local oscillators. Finally, the benefits of sub-doppler spectroscopy are illustrated by heterodyne spectroscopy of the atmospheres of Jupiter and Venus.

Mumma, M. J.↗

Diode Laser Velocity Measurements by Modulated Filtered Rayleigh Scattering

The ability of solid-state lasers to be tuned in operating frequency at MHz rates by input current modulation, while maintaining a relatively narrow line-width, has made them useful for spectroscopic measurements. Their other advantages include low cost, reliability, durability, compact size, and modest power requirements, making them a good choice for a laser source in micro-gravity experiments in drop-towers and in flight. For their size, they are also very bright. In a filtered Rayleigh scattering (FRS) experiment, a diode laser can be used to scan across an atomic or molecular absorption line, generating large changes in transmission at the resonances for very small changes in frequency. The hyperfine structure components of atomic lines of alkali metal vapors are closely spaced and very strong, which makes such atomic filters excellent candidates for sensitive Doppler shift detection and therefore for high-resolution velocimetry. In the work we describe here we use a Rubidium vapor filter, and work with the strong D(sub 2) transitions at 780 nm that are conveniently accessed by near infrared diode lasers. The low power output of infrared laser diodes is their primary drawback relative to other laser systems commonly used for velocimetry. However, the capability to modulate the laser frequency rapidly and continuously helps mitigate this. Using modulation spectroscopy and a heterodyne detection scheme with a lock-in amplifier, one can extract sub-microvolt signals occurring at a specific frequency from a background that is orders of magnitude stronger. The diode laser modulation is simply achieved by adding a small current modulation to the laser bias current. It may also be swept repetitively in wavelength using an additional lower frequency current ramp.

Mach, J. J.↗

Photon Frequency Conversion in High-Q Superconducting Resonators: Axion Electrodynamics, QED, and Nonlinear Meissner Radiation

High-Q superconducting resonators have been proposed and developed as detectors of light-by-light scattering mediated by the hypothesized axion or virtual electron–positron pairs in quantum electrodynamics: the Euler–Heisenberg (EH) interaction. Photon frequency and mode conversion is central to the scheme for detecting such rare events. Superconducting resonators are nonlinear devices. The Meissner screening currents that confine the electromagnetic fields to the vacuum region of a superconducting RF cavity are nonlinear functions of the EM field at the vacuum–superconducting interface, and as a result can generate source currents and frequency conversion of microwave photons in the cavity. In this report we consider photon frequency and mode conversion in superconducting resonators with high quality factors from Meissner currents in single- and dual-cavity setups proposed for axion and QED searches based on light-by-light scattering. In a single cavity with two pump modes, photon frequency conversion by the Meissner screening current dominates photon generation by the EH interaction for cavities with Q≲1012⁠. The Meissner currents also generate background photons that limit the operation of the resonator for axion detection in three-mode, single-cavity setups. We also consider the leakage of photons from pump modes into the signal mode for both axion- and EH-mediated light-by-light scattering. Photon frequency conversion by the EH interaction can compete with Meissner and leakage radiation in ultra-high-Q cavities that are beyond the current state of the art. Meissner radiation and leakage backgrounds can be suppressed in dual-cavity setups with appropriate choices for pump and spectator modes, as well as the single-cavity setup proposed for heterodyne detection of galactic axion dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large Bandwidth and Low Noise in a Diffusion-Cooled Hot-Electron Bolometer Mixer

X Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 ??ong niobium microbridge with T c =(approx. equal to)5K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if{italics})) of several GHz. A Y-factor response of 1.15dB has been obtained at an if(italics) of 1.4 GHz with 77k and 295k loads, indicating a receiver noise temperature of 650 k DSB. The -3 dB rolloff in the if(italics) response occurs at 1.7 GHz.

Heterodyne↗

Theoretical simulation of a 2 micron airborne solid state laser anemometer

In the near future, military aircraft will need to know precisely their true airspeed in order to optimize flight conditions. In comparison with classical anemometer probes, an airborne Doppler lidar allows measurement of the air velocity without influence from aircraft aerodynamic disturbance. While several demonstration systems of heterodyne detection using a CO2 laser have been reported, improvements in the technology of solid state lasers have recently opened up the possibility that these devices can be used as an alternative to CO2 laser systems. In particular, a diode pumped Tm:Ho:YAG laser allows a reliable compact airborne system with an eye safe wavelength (lambda = 2.09 microns) to be achieved. The theoretical study of performances of a coherent lidar using a solid state diode pumped Tm:Ho:YAG laser, caled SALSA, for measuring aircraft airspeed relative to atmospheric aerosols is described. A computer simulation was developed in order to modelize the Doppler anemometer in the function of atmospheric propagation and optical design. A clever analysis of the power budget on the detector area allows optical characteristic parameters of the system to be calculated, and then it can be used to predict performances of the Doppler system. Estimating signal to noise ratios (SNR) and heterodyne efficiency provides the available energy of speed measurement as well as a useful measurement of the alignment of the backscattered and reference fields on the detector.

Imbert, Beatrice↗

Time-domain Brillouin scattering theory for probe light and acoustic beams propagating at an angle and acousto-optic interaction at material interfaces

A theory has been developed to interpret time-domain Brillouin scattering (TDBS) experiments involving coherent acoustic pulse (CAP) and light pulse beams propagating at an angle to each other. It predicts the influence of the directivity pattern of their acousto-optic interaction on TDBS signals when heterodyne detection of acoustically scattered light is in backward direction to incident light. The theory reveals relationships between the carrier frequency, amplitude and duration of acoustically induced ”wave packets” in light transient reflectivity signals, and factors such as CAP duration, widths of light and sound beams, and their interaction angle. It describes the transient dynamics of these wave packets when the light and CAP encounter material interfaces, and how the light scattering by the incident CAP transforms into scattering by the reflected and transmitted CAPs. The theory suggests that single-point TDBS experiments can determine not only depth positions of buried interfaces but also their local inclinations/orientations.

42 ENGINEERING↗

Probing magnon–magnon coupling in exchange coupled Y 3 Fe 5 O 12 /Permalloy bilayers with magneto-optical effects

We demonstrate the magnetically-induced transparency (MIT) effect in Y 3 Fe 5 O 12 (YIG)/Permalloy (Py) coupled bilayers. The measurement is achieved via a heterodyne detection of the coupled magnetization dynamics using a single wavelength that probes the magneto-optical Kerr and Faraday effects of Py and YIG, respectively. Clear features of the MIT effect are evident from the deeply modulated ferromagnetic resonance of Py due to the perpendicular-standing-spin-wave of YIG. We develop a phenomenological model that nicely reproduces the experimental results including the induced amplitude and phase evolution caused by the magnon–magnon coupling. Our work offers a new route towards studying phase-resolved spin dynamics and hybrid magnonic systems

36 MATERIALS SCIENCE↗

Kelvin probe force microscopy under ambient conditions

Kelvin probe force microscopy (KPFM) is a technique derived from atomic force microscopy that provides maps of surface potential or work function differences across material systems, with nanometre-scale resolution. KPFM is a useful tool for investigating electrical phenomena such as dipole orientation, interfacial charge transfer, charge accumulation, band bending and doping levels. This Primer aims to provide an overview of typical ambient-condition KPFM measurements, covering their underlying principles, experimental implementations and wide-ranging applications. Key KPFM variants, including amplitude and frequency modulation, heterodyne detection schemes and innovative open loop and pulsed force techniques, are discussed, with practical guidance on optimizing signal acquisition and reducing errors. Specialized approaches, such as time-resolved KPFM and multimodal KPFM, are discussed for their ability to capture dynamic charge processes and chemical information, respectively. Here, we highlight recent advances in KPFM applications, spanning metal alloys, soft matter, ferroelectrics, photovoltaics and 2D materials, showcasing its versatility across research domains. By addressing current limitations and identifying future opportunities, this Primer underscores the transformative potential of KPFM in advancing the understanding of nanoscale electrical phenomena.

Zahmatkeshsaredorahi, Amirhossein [Lehigh Univ., B↗

The N3/TiO 2 interfacial structure is dependent on the pH conditions during sensitization

The electronic structure of the N3/TiO 2 interface can directly influence the performance of a dye sensitized solar cell (DSSC). Therefore, it is crucial to understand the parameters that control the dye’s orientation on the semiconductor’s surface. A typical step in DSSC fabrication is to submerge the nanoparticulate semiconductor film in a solution containing the dye, the sensitizing solution. The pH of the N3 sensitizing solution determines the distribution of the N3 protonation states that exist in solution. Altering the pH of the sensitizing solution changes the N3 protonation states that exist in solution and, subsequently, the N3 protonation states that anchor to the TiO 2 substrate. We utilize the surface specific technique of heterodyne detected vibrational sum frequency generation spectroscopy to determine the binding geometry of N3 on a TiO 2 surface as a function of the sensitizing solution pH conditions. It is determined that significant reorientation of the dye occurs in pH ≤ 2.0 conditions due to the lack of N3-dye carboxylate anchoring groups participating in adsorption to the TiO 2 substrate. Consequently, the change in molecular geometry is met with a change in the interfacial electronic structure that can hinder electron transfer in DSSC architectures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated microwave acousto-optic frequency shifter on thin-film lithium niobate

Electrically driven acousto-optic devices that provide beam deflection and optical frequency shifting have broad applications from pulse synthesis to heterodyne detection. Commercially available acousto-optic modulators are based on bulk materials and consume Watts of radio frequency power. Here, we demonstrate an integrated 3-GHz acousto-optic frequency shifter on thin-film lithium niobate, featuring a carrier suppression over 30 dB. Further, we demonstrate a gigahertz-spaced optical frequency comb featuring more than 200 lines over a 0.6-THz optical bandwidth by recirculating the light in an active frequency shifting loop. Our integrated acousto-optic platform leads to the development of on-chip optical routing, isolation, and microwave signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian homodyne and heterodyne tomography

Continuous-variable (CV) photonic states are of increasing interest in quantum information science, bolstered by features such as deterministic resource state generation and error correction via bosonic codes. Data-efficient characterization methods will prove critical in the fine-tuning and maturation of such CV quantum technology. Although Bayesian inference offers appealing properties—including uncertainty quantification and optimality in mean-squared error—Bayesian methods have yet to be demonstrated for the tomography of arbitrary CV states. Here we introduce a complete Bayesian quantum state tomography workflow capable of inferring generic CV states measured by homodyne or heterodyne detection, with no assumption of Gaussianity. As examples, we demonstrate our approach on experimental coherent, thermal, and cat state data, obtaining excellent agreement between our Bayesian estimates and theoretical predictions. Our approach lays the groundwork for Bayesian estimation of highly complex CV quantum states in emerging quantum photonic platforms, such as quantum communications networks and sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗