Search NASA⌕ Search

SEARCH · Search NASA

Results for “high frequency of measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A validation of LTRAN2 with high frequency extensions by comparisons with experimental measurements of unsteady transonic flows

A high frequency extension of the unsteady, transonic code LTRAN2 was created and is evaluated by comparisons with experimental results. The experimental test case is a NACA 64A010 airfoil in pitching motion at a Mach number of 0.8 over a range of reduced frequencies. Comparisons indicate that the modified code is an improvement of the original LTRAN2 and provides closer agreement with experimental lift and moment coefficients. A discussion of the code modifications, which involve the addition of high frequency terms of the boundary conditions of the numerical algorithm, is included.

Hessenius, K. A.↗

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

Strayer, D. M.↗

Measurements and Computations of Second-Mode Instability Waves in Three Hypersonic Wind Tunnels

High-frequency pressure-fluctuation measurements were made in AEDC Tunnel 9 at Mach 10 and the NASA Langley 15-Inch Mach 6 and 31-Inch Mach 10 tunnels. Measurements were made on a 7deg-half-angle cone model. Pitot measurements of freestream pressure fluctuations were also made in Tunnel 9 and the Langley Mach-6 tunnel. For the first time, second-mode waves were measured in all of these tunnels, using 1-MHz-response pressure sensors. In Tunnel 9, second-mode waves could be seen in power spectra computed from records as short as 80 micro-s. The second-mode wave amplitudes were observed to saturate and then begin to decrease in the Langley tunnels, indicating wave breakdown. Breakdown was estimated to occur near N approx. equals 5 in the Langley Mach-10 tunnel. The unit-Reynolds-number variations in the data from Tunnel 9 were too large to see the same processes. In Tunnel 9, the measured transition locations were found to be at N = 4.5 using thermocouples, and N = 5.3 using 50-kHz-response pressure sensors. What appears to be a very long transitional region was observed at a unit Reynolds number of 13.5 million per meter in Tunnel 9. These results were consistent with the high-frequency pressure fluctuation measurements. High-frequency pressure fluctuation measurements indicated that transition did occur in the Langley Mach-6 tunnel, but the location of transition was not precisely determined. Unit Reynolds numbers in the Langley Mach-10 tunnel were too low to observe transition. More analysis of this data set is expected in the future.

Berridge, Dennis C.↗

Observation and comparison of rainfall measured at a high sample rate

Two NASA programs, the Effects of Heavy Rain on Aerodynamics and the Tropical Rainfall Measuring Mission, require accurate high-frequency rainfall measurements. A weight-measuring rain gauge was developed to collect rain data and configured to operate at a high sample rate. The design of the gauge and preliminary test are briefly described. Frequency distributions of rainfall rates determined at five observation sites in the U.S. and at one in Australia are presented.

Melson, W. E., Jr.↗

International Space Station Increment-3 Microgravity Environment Summary Report

This summary report presents the results of some of the processed acceleration data measured aboard the International Space Station during the period of August to December 2001. Two accelerometer systems were used to measure the acceleration levels for the activities that took place during Increment-3. However, not all of the activities were analyzed for this report due to time constraint and lack of precise timeline information regarding some payload operations and station activities. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Microgravity System to support microgravity science experiments which require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System unit was flown to the station in support of science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit was flown to support experiments requiring vibratory acceleration measurement. Both acceleration systems are also used in support of the vehicle microgravity requirements verification. The International Space Station Increment-3 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: (1) The Microgravity Acceleration Measurement System, which consists of two sensors: the Orbital Acceleration Research Experiment Sensor Subsystem, a low frequency range sensor (up to 1 Hz), is used to characterize the quasi-steady environment for payloads and vehicle, and the High Resolution Accelerometer Package, which is used to characterize the vibratory environment up to 100 Hz. (2) The Space Acceleration Measurement System, which is a high frequency sensor, measures vibratory acceleration data in the range of 0.01 to 400 Hz. This summary report presents analysis of some selected quasi-steady and vibratory activities measured by these accelerometers during Increment-3 from August to December, 2001.

Jules, Kenol↗

International Space Station Increment-2 Microgravity Environment Summary Report

This summary report presents the results of some of the processed acceleration data, collected aboard the International Space Station during the period of May to August 2001, the Increment-2 phase of the station. Two accelerometer systems were used to measure the acceleration levels during activities that took place during the Increment-2 segment. However, not all of the activities were analyzed for this report due to time constraints, lack of precise information regarding some payload operations and other station activities. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Microgravity System to support microgravity science experiments, which require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System unit was flown to the station in support of science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit was flown to support experiments requiring vibratory acceleration measurement. Both acceleration systems are also used in support of vehicle microgravity requirements verification. The International Space Station Increment-2 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: 1) The Microgravity Acceleration Measurement System, which consists of two sensors: the Orbital Acceleration Research Experiment Sensor Subsystem, a low frequency range sensor (up to 1 Hz), is used to characterize the quasi-steady environment for payloads and the vehicle, and the High Resolution Accelerometer Package, which is used to characterize the vibratory environment up to 100 Hz. 2) The Space Acceleration Measurement System, which is a high frequency sensor, measures vibratory acceleration data in the range of 0.01 to 300 Hz. This summary report presents analysis of some selected quasisteady and vibratory activities measured by these accelerometers during Increment-2 from May to August 20, 2001.

Jules, Kenol↗

Intermediate term frequency measurements with the HP computing counter in the USNO clock time system

High precision frequency measurements with various integration times can be made with conventional counters by using variable gate times. The Hewlett-Packard (HP) computing counter allows such measurements over a wide range of frequencies and measurement times. This instrument can also convert period measurements into frequency by means of its arithmetic capabilities: The program library contains programs to facilitate frequency stability measurements in the most direct and convenient way. This method was used as the basis for all time scale computations, until requirements for highest resolution justified the development of an automatic data acquisition system. The phase measurements are now being made with the HP computing counter (with time interval plug-in unit) under program control from the HP System Programmer.

Winkler, G. M. R.↗

Piezoelectric impedance-based high-accuracy damage identification using sparsity conscious multi-objective optimization inverse analysis

Two elements are essential in structural health monitoring utilizing dynamic responses: response measurement with high-frequency contents, i.e., small characteristic wavelengths, that can adequately reflect damage features, and effective inverse identification analysis that is however oftentimes under-determined. The advancement of smart structure integration has led to active interrogation through frequency-sweeping piezoelectric impedance measurement at high frequency range. In this research we develop a multi-objective optimization formulation for the identification of damage location and severity utilizing piezoelectric impedance. While one optimization objective is to match the response measurement with finite element model prediction in the damage parametric space, the other is the number of locations of damage, i.e., the sparsity of damage index as the solution vector, since damage usually occurs within a small number of locations. This multi-objective formulation fits well the under-determined nature of damage identification, as it naturally provides multiple solutions as basis for further elucidation. The challenge remaining is how to find a small solution set that can include the actual damage scenario. Here we develop a novel inverse identification framework utilizing the intelligent swarm optimizer which possesses flexibility for enhancement. We first embed a sparsity enforcement process into the population generation of the optimizer, which yields a solution repository intrinsically possessing sparsity. We then apply reinforcement learning so the agents can adaptively opt for local strategies with the aim of enriching the searching patterns to diversify the solutions. Through the incorporation of a Q-table, searching toward more promising directions will be rewarded. Our case analyses employing experimental data indicate that this sparsity-conscious multi-objective particle swarm optimization technique can lead to a small solution set which generally encompasses the true damage scenario. This effectively solves the structural damage identification problem with piezoelectric impedance measurement.

Yang Zhang↗

Bulk modulus measurement at mHz frequencies and high-pressure using synchrotron x-ray radiation

We report an experimental protocol for measuring the frequency dependence of the bulk modulus carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. An oscillating pressure perturbation characterized by x-ray diffraction produces a volume strain measured by imaging. Together, these yield the bulk modulus of the sample. In this work, we report data at 3 mHz as an example of the possibility of providing these data for the frequency range of 1 mHz–100 mHz.

47 OTHER INSTRUMENTATION↗

Calibration of PCB-132 Sensors in a Shock Tube

While PCB-132 sensors have proven useful for measuring second-mode instability waves in many hypersonic wind tunnels, they are currently limited by their calibration. Until now, the factory calibration has been all that was available, which is a single-point calibration at an amplitude three orders of magnitude higher than a second-mode wave. In addition, little information has been available about the frequency response or spatial resolution of the sensors, which is important for measuring high-frequency instability waves. These shortcomings make it difficult to compare measurements at different conditions and between different sensors. If accurate quantitative measurements could be performed, comparisons of the growth and breakdown of instability waves could be made in different facilities, possibly leading to a method of predicting the amplitude at which the waves break down into turbulence, improving transition prediction. A method for calibrating the sensors is proposed using a newly-built shock tube at Purdue University. This shock tube, essentially a half-scale version of the 6-Inch shock tube at the Graduate Aerospace Laboratories at Caltech, has been designed to attain a moderate vacuum in the driven section. Low driven pressures should allow the creation of very weak, yet still relatively thin shock waves. It is expected that static pressure rises within the range of second-mode amplitudes should be possible. The shock tube has been designed to create clean, planar shock waves with a laminar boundary layer to allow for accurate calibrations. Stronger shock waves can be used to identify the frequency response of the sensors out to hundreds of kilohertz.

Berridge, Dennis C.↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigations of lubricant rheology as applied to elastohydrodynamic lubrication

Traction prediction in sliding elastohydrodynamic (EHD) contacts was examined along with an elastohydrodynamic lubrication simulation of the effects of load and speed on temperatures in the EHD contact. An existing shear stress theory and lubricant rheological model were studied and evaluated by applying them to traction prediction. Results obtained using measured film thickness and surface temperature data, were compared with measured traction values. The infrared technique for measuring temperatures in an EHD contact was further developed and ball surface and fluid temperatures are reported for sliding speeds of 0.35 to 5.08 m/s at 0.52 to 2.03 GN/sq m maximum pressure and surface roughnesses of .011 to .381 micrometers c.1.a. The relationship between asperity interaction, as measured by relocation surface profilimetry and high frequency temperature measurements, and the ratio of film thickness to surface roughness was also studied.

Kunz, R. K.↗

Effects of load, speed, and surface roughness on sliding EHD contact temperatures

An infrared technique has been used to determine the effects of load, speed and surface roughness on temperature in a sliding elastohydrodynamic (EHD) point contact. Ball surface temperatures are reported for sliding speeds of 0.35 to 5.08 m/s at 0.52 to 2.03 GN/per sq m maximum pressure with surface roughness in the range 0.01 to 0.38 micron c.l.a. The relationship between asperity interaction, as measured by relocation surface profilimetry and high frequency temperature measurements, and the ratio of film thickness to surface roughness has also been studied.

Nagaraj, H. S.↗

An Analysis of the Lightning Jump Algorithm Using Geostationary Lightning Mapper Flashes

Lightning's relation to severe weather has been studied since the 1980's. The invention of the Lightning Mapping Array allowed for total lightning measurements in a 125 km operational range. This brought forth an automated lightning Jump Algorithm (LIA) that predicted severe weather based on two-sigma increases in total lightning. The LIA's biggest downfall is being restrained to the limited field of view (FOV) of LMA's. The launch of the Geostationary Lightning Mapper (GLM) aboard the GOES-16 satellite now gives us hemispheric total lightning measurements. The wide FOV makes the GLM a good candidate to apply the LIA to. However the GLM and LMA have some differences. One being the coarser spatial resolution of GLM. Another being that LMA measures very high frequency (VHF) electromagnetic radiation while GLM measures optical radiation. These differences suggest an extensive study must be done on using the LIA with GLM to understand potential differences in the LIA and to maximize its operational skill. Four deep dive cases are conducted showcasing the differences between the GLM and LMA and their jumps.

Curtis, Nathan↗

Pressure and Thrust Measurements of a High-Frequency Pulsed-Detonation Actuator

This paper describes the development of a small-scale, high-frequency pulsed detonation actuator. The device utilized a fuel mixture of H2 and air, which was injected into the device at frequencies of up to 1200 Hz. Pulsed detonations were demonstrated in an 8-inch long combustion volume, at approx.600 Hz, for the lambda/4 mode. The primary objective of this experiment was to measure the generated thrust. A mean value of thrust was measured up to 6.0 lb, corresponding to specific impulse of 2611 s. This value is comparable to other H2-fueled pulsed detonation engines (PDEs) experiments. The injection and detonation frequency for this new experimental case was approx.600 Hz, and was much higher than typical PDEs, where frequencies are usually less than 100 Hz. The compact size of the model and high frequency of detonation yields a thrust-per-unit-volume of approximately 2.0 lb/cu in, and compares favorably with other experiments, which typically have thrust-per-unit-volume values of approximately 0.01 lb/cu in.

Nguyen, Namtran C.↗

High Speed and High Spatial Density Parameter Measurement Using Fiber Optic Sensing Technology

The present invention is an improved fiber optic sensing system (FOSS) having the ability to provide both high spatial resolution and high frequency strain measurements. The inventive hybrid FOSS fiber combines sensors from high acquisition speed and low spatial resolution Wavelength-Division Multiplexing (WDM) systems and from low acquisition speed and high spatial resolution Optical Frequency Domain Reflection (OFDR) systems. Two unique light sources utilizing different wavelengths are coupled with the hybrid FOSS fiber to generate reflected data from both the WDM sensors and OFDR sensors operating on a single fiber optic cable without incurring interference from one another. The two data sets are then de-multiplexed for analysis, optionally with conventionally-available WDM and OFDR system analyzers.

Parker, Allen R. Jr.↗