Search NASA⌕ Search

SEARCH · Search NASA

Results for “high gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

Pulse Length Monitor for Breakdown Diagnostics in THz and Mm-Wave Accelerators

The development of novel high-gradient accelerating structures operating at THz frequencies is critical for future free-electron lasers and TeV scale linear colliders. To reach high energies with reasonable length requires high accelerating gradients of ~100 MV/m. The main limitation to reaching these high-energy gradients is the vacuum RF breakdown phenomenon, which disrupts normal accelerator operations. For stable operations and to understand the breakdown microscopic dynamics, a new device capable of detecting the breakdown occurrences is required. In this paper, we provide the design of a pulse length monitor based on an analog to digital converter for fast signal digitization without the need to use high-speed digitizers to be used in a commercial mm-wave heterodyne spectrometer.

43 PARTICLE ACCELERATORS↗

Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches

High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC national accelerator laboratory. Here we have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1–10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (> 30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (< 10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30–160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure ≥ 1.5Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2Torr, simulation results and experimental data show that the beam transfers about 60% of its energy to the wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microstructure development in a cold worked SRF Nb sheet undergoing 700°C-900°C/3h heat treatments.

Bulk Nb for TESLA shaped SRF cavities is a mature technology, with high gradient (>35 MV/m) and high Q cavities (>1010, ~2K) routinely fabricated. Significant advances are in order to push Q?s to 1011 (~2K), and involve modifications to the sub-surface Nb layers by impurity doping (N, O). In order to achieve the lowest surface resistance any trapped flux needs to be expelled for cavities to reach high Q?s. There is clear evidence that cavities fabricated from polycrystalline sheets meeting current specifications require higher temperatures beyond 800oC leads to better flux expulsion, and hence improves Q. Recently, cavities fabricated with a non-traditional Nb sheet with initial cold work due to cold rolling expelled flux better after 800°C/3h heat treatment than cavities fabricated using fine-grain polycrystalline Nb sheets. Here, we analyze the microstructure development in Nb from the vendor supplied cold work non-annealed sheet that was fabricated into an SRF cavity as a function of heat treatment building upon the methodology development to analyze microstructure being developed by the FSU-MSU-UT-Austin- JLAB collaboration. The results indicate correlation between full recrystallization and better flux expulsion.

Balachandran, S.↗

A proton beam energy modulator for rapid proton therapy

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.

47 OTHER INSTRUMENTATION↗

Experimental design of a W-band corrugated waveguide for wakefield acceleration studies

Radiofrequency (RF) structures in the sub-terahertz (sub-THz) regime are of interest for applications in structure wakefield acceleration due to their compact size and potential for high gradients. Here, we present the design, fabrication, and experimental setup of a metallic corrugated waveguide at 110 GHz, optimized for the 42 MeV electron beam parameters at the Argonne Wakefield Accelerator (AWA). The emittance exchange (EEX) beamline at AWA was used to perform longitudinal bunch shaping for two cases: (1) a high decelerating gradient experienced by a single drive electron bunch about 250 μm long; (2) a high transformer ratio using a two-bunch train consisting of a triangularly shaped drive bunch followed by a long witness bunch to probe the wakefield. Preliminary experimental results are presented, and data analysis is ongoing.

43 PARTICLE ACCELERATORS↗

Wakefield generation in hydrogen and lithium plasmas at FACET-II: Diagnostics and first beam-plasma interaction results

Plasma wakefield acceleration provides ultrahigh acceleration gradients of tens of GeV/m, providing a novel path toward efficient, compact, TeV-scale linear colliders, and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single-stage plasma wakefield accelerator, providing a 10 GeV energy gain in a < 1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm mrad accuracy, energy spectra to determine both percent level energy spread, and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed as well as commissioning of the plasma sources and diagnostics. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

The Low-Beta Quadrupoles for the High-Luminosity Large Hadron Collider: enabling higher luminosity by using Nb_3Sn conductor

The large-aperture, high-gradient Low Beta Quadrupoles for the High Luminosity Large Hadron Collider at CERN are the cornerstones of this collider. They are first-of-the-kind accelerator magnets bringing Nb_3Sn conductor to High Energy Physics colliders. In the US they are being fabricated and tested by the HL-LHC Accelerator Upgrade Project (AUP), and in Europe by CERN. The design was developed by AUP and CERN in close collaboration. The Q1/Q3 cryo-assemblies contain two 4.2 m long magnets (MQXFA) fabricated and by AUP. They are tested vertically before use in a cry-assembly. In this paper we are going to present the main features of the MQXFA design, results of vertical tests, and main lessons learned. We will also discuss lessons learned for future use of Nb_3Sn magnets in HEP colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma-based particle sources

High-brightness particle beams generated by advanced accelerator concepts have the potential to become an essential part of future accelerator technology. In particular, high-gradient accelerators can generate and rapidly accelerate particle beams to relativistic energies. The rapid acceleration and strong confining fields can minimize irreversible detrimental effects to the beam brightness that occur at low beam energies, such as emittance growth or pulse elongation caused by space charge forces. Due to the high accelerating gradients, these novel accelerators are also significantly more compact than conventional technology. Advanced accelerators can be extremely variable and are capable of generating particle beams with vastly different properties using the same driver and setup with only modest changes to the interaction parameters. So far, efforts have mainly been focused on the generation of electron beams, but there are concepts to extend the sources to generate spin-polarized electron beams or positron beams. The beam parameters of these particle sources are largely determined by the injection and subsequent acceleration processes. Although, over the last decade there has been significant progress, the sources are still lacking a sufficiently high 6-dimensional (D) phase-space density that includes small transverse emittance, small energy spread and high charge, and operation at high repetition rate. This is required for future particle colliders with a sufficiently high luminosity or for more near-term applications, such as enabling the operation of free-electron lasers (FELs) in the X-ray regime. Major research and development efforts are required to address these limitations in order to realize these approaches for a front-end injector for a future collider or next-generation light sources. In particular, this includes methods to control and manipulate the phase-space and spin degrees-of-freedom of ultrashort plasma-based electron bunches with high accuracy, and methods that increase efficiency and repetition rate. These efforts also include the development of high-resolution diagnostics, such as full 6D phase-space measurements, beam polarimetry and high-fidelity simulation tools. A further increase in beam luminosity can be achieve through emittance damping. Emittance cooling via the emission of synchrotron radiation using current technology requires kilometer-scale damping rings. For future colliders, the damping rings might be replaced by a substantially more compact plasma-based approach. Here, plasma wigglers with significantly stronger magnetic fields are used instead of permanent-magnet based wigglers to achieve similar damping performance but over a two orders of magnitude reduced length.

43 PARTICLE ACCELERATORS↗

Experimental demonstration of externally driven millimeter-wave particle accelerator structure

We report the experimental demonstration of a mm-wave electron accelerating structure powered by a high-power rf source. We demonstrate reliable coupling of an unprecedented rf power—up to 575kW into the mm-wave accelerator structure using a quasi-optical setup. This standing wave accelerating structure consists of a single-cell copper cavity and a Gaussian to TM 01 mode converter. The accelerator structure is powered by 110 GHz, 10-ns long rf pulses. These pulses are chopped from 3 microsecond pulses from a gyrotron oscillator using a laser-driven silicon switch. We show an unprecedented high gradient up to 230MV/m that corresponds to a peak surface electric field of more than 520 MV/m. We have achieved these results after conditioning the cavity with more than 100,000 pulses. We also report preliminary measurements of rf breakdown rates, which are important for understanding rf breakdown physics in the millimeter-wave regime. Furthermore, these results open up many frontiers for applications not only limited to the next generation particle accelerators but also x-ray generation, probing material dynamics, and nonlinear light-matter interactions at mm-wave frequency.

43 PARTICLE ACCELERATORS↗

Suppression of Deflecting Forces in Planar-Symmetric Dielectric Wakefield Accelerating Structures with Elliptical Bunches

Wakefield based accelerators capable of accelerating gradients two orders of magnitude higher than present accelerators offer a path to compact high energy physics instruments and light sources. However, for high gradient accelerators, beam instabilities driven by commensurately high transverse wakefields limit beam quality. It has been previously theoretically shown that transverse wakefields can be reduced by elliptically shaping the transverse sizes of beams in dielectric structures with planar symmetry. We report here experimental measurements that demonstrate reduced transverse wakefields for elliptical beams in planar symmetric structures which are consistent with theoretical models. Furthermore, these results may enable the design of gigavolt-per-meter gradient wakefield based accelerators that produce and stably accelerate high quality beams.

47 OTHER INSTRUMENTATION↗

Optimizing detachment control using the magnetic configuration of divertors

Abstract As tokamak research moves to reactor conditions, the control of a stable, optimally-detached divertor plasma has become increasingly relevant. Simple predictions of such detachment control have been performed previously using the detachment location sensitivity (DLS) model (Lipschultz et al 2016 Nucl. Fusion 56 056007). In this study the DLS model is extended and combined with SOLPS-ITER simulations of isolated divertor grids to study the effects of alternate divertor magnetic field properties on detachment control. The DLS model predicts that divertors can achieve easier access to detachment through a long connection length, a high total flux expansion, and a high average magnetic field in the divertor compared with that at the x -point. SOLPS-ITER simulations suggest an even stronger impact of total flux expansion and connection length on detachment access than the DLS model predicts. In terms of detachment evolution, both simulation and modelling show a high gradient in the total magnetic field and low B p o l B are able to more easily keep a detachment front at a desired poloidal location. Regions with no stable detachment front locations can arise for high magnetic field gradients directed towards the target. Significant differences have been found between impurity scan simulations and the DLS model. These differences may be attributed to sources and sinks of power and electron pressure, and should be explored further in future work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Performance Accelerator Modeling: Toward Improving Controls and Diagnostics for High-Brightness Beams in Experiment

One of the main charges of beam physics is to improve the overall beam quality delivered to experiments and applications, which is generally quantified by the beam brightness. High brightness beams have numerous applications, including x-ray free electron lasers and ultrafast electron diffraction (UED). To these ends, this thesis details efforts to use high-performance models --- high-fidelity models that execute quickly --- for controls and diagnostics. To demonstrate the generality of these techniques, this thesis focuses on three of the most successful photoinjector designs currently used worldwide: the UCLA/SLAC/BNL-type high-gradient S-band gun, the continuous-wave high-repetition rate VHF APEX gun and the L-band DESY-PITZ-type gun. Work will be shown from Pegasus (UCLA), HiRES (LBNL) and FAST (FNAL).Specifically, data-driven models for online virtual diagnostics are presented, in this case, in the context of UED at HiRES, leading to a temporal resolution improvement. Methods for improving the fidelity of physics-based models are discussed, with examples at HiRES, Pegasus and FAST. Markov-chain Monte Carlo analysis is applied to match simulations, in the context of photocathode studies at HiRES and Pegasus. Lastly, the augmentation of online model-based predictions with model-independent optimization is explored in a fluctuating environment at Pegasus and HiRES. A central theme of this dissertation is working with parameter fluctuations when modeling an accelerator beamline. Long-term drifts and shot-to-shot jitter exist in every accelerator to a varying degree and therefore play an important role in every chapter of this dissertation. This thesis attempts to address the issues associated with these fluctuations when trying to develop faithful model representations of the system.

43 PARTICLE ACCELERATORS↗

Warm to cold correlations and other test results of the MQXFA Low-Beta Quadrupole magnets for the High-Luminosity Large Hadron Collider

The production of the MQXFA low-beta quadrupole magnets for the High Luminosity LHC (HL-LHC) is quite advanced with about 20 magnets cold tested in vertical cryostat. The MQXFA magnets are fabricated by the US HL-LHC Accelerator Upgrade Project (AUP) and are being used in the Q1 and Q3 Inner Triplet (IT) elements of the HL-LHC, whereas CERN is fabricating similar magnets for Q2a and Q2b IT elements. These large-aperture, high-gradient quadrupole magnets are first-of-the-kind accelerator magnets introducing Nb_3Sn conductor to High Energy Physics colliders. At this point of MQXFA production there is sufficient data to look at warm to cold correlations for the HL-LHC and for future use of Nb_3Sn magnets in particle accelerators. Examples of warm-cold correlations discussed in this paper are: field quality (including the use of magnetic shims for low-order harmonics correction), magnetic length, magnetic axis and magnetic field angle. A summary of main test data will also be presented and discussed.

Kurian, F. [Brookhaven]↗

An Overview of RF Systems for the EIC

The Electron Ion Collider (EIC) to be constructed at Brookhaven National Laboratory in the USA will be a complex system of accelerators providing high luminosity, high polarization, variable center of mass energy collisions between electrons and protons or ions. To achieve this a variety of RF systems are required. They must provide for capture, formation and storage of Ampere-class beams in the electron and hadron storage rings (ESR and HSR), fast acceleration of high-charge polarized electron bunches in the rapid cycling synchrotron (RCS), provision of cold high current electron bunches in the high-energy cooler ERL and precise high-gradient crabbing of electrons and hadrons either side of the interaction point. The challenges include strong HOM damping in the storage ring cavities and cooler ERL, very high fundamental mode power in the ESR and cooler injector, extremely stable low-noise operation of the crab cavities, mitigation of transient beam loading from gaps, and operating over a wide range of energies and beam currents. We describe the high-level system parameters and principal design choices made and progress on the R&D plan to develop these state of the art systems.

Rimmer, R. A.↗

ERL-Based Compact X-Ray FEL

We propose to develop an energy-recovery-linac (ERL)-based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗