Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Advances toward high spectral resolution quantum X-ray calorimetry

Thermal detectors for X-ray spectroscopy combining high spectral resolution and quantum efficiency have been developed. These microcalorimeters measure the energy released in the absorption of a single photon by sensing the rise in temperature of a small absorbing structure. The ultimate energy resolution of such a device is limited by the thermodynamic power fluctuations in the thermal link between the calorimeter and isothermal bath and can in principle be made as low as 1 eV. The performance of a real device is degraded due to noise contributions such as excess 1/f noise in the thermistor and incomplete conversion of energy into phonons. The authors report some recent advances in thermometry, X-ray absorption and thermalization, fabrication techniques, and detector optimization in the presence of noise. These improvements have resulted in a device with a spectral resolution of 17 eV FWHM, measured at 6 keV.

Moseley, S. H.↗

The Chandra X-Ray Observatory and its Role for the Study of Ionized Plasmas

NASA's Chandra X-Ray Observatory was launched in July of 1999. Featuring a 1000cm2-class X-ray telescope with sub-arcsecond angular resolution, the Observatory has observed targets from the solar system including the earth s moon, comets, and planets to the most distant galaxy clusters and active galactic nuclei. Capable of performing moderate energy resolution image-resolved spectroscopy using its CCD detectors, and high-resolution grating spectroscopy, the Observatory has produced, and continues to produce, valuable data and insights into the emission mechanisms of the ionized plasmas in which the X-rays originate. We present a brief overview of the Observatory to provide insight as to how to use it for your investigations. We also present an, admittedly brief and biased, overview of some of the results of investigations performed with Chandra that may be of interest to this audience.

Weisskopf, Martin C.↗

Experimental tests of a single-photon calorimeter for X-ray spectroscopy

Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.

Mccammon, D.↗

Development of a High-Resolution, Single-Photon X-Ray Detector

Research on the development of a low-temperature, magnetic bolometer for x-ray detection is reported. The principal accomplishments during the first phase of this research are as follows. (1) We have constructed SQUID magnetometers and detected both 122 keV and 6 keV x-rays in relatively larger metallic samples with high quantum efficiency. (2) The magnetic properties of a metal sample with localized paramagnetic spins have been measured and found to agree with theoretical expectations. (3) The size of the magnetic response of the sample to x-rays is in agreement with predictions based on the properties of the sample and sensitivity of the magnetometer, supporting the prediction that a resolution of 1 eV at 10 keV should be achievable.

Seidel, George M.↗

SONGS - A high resolution imaging gamma-ray spectrometer for the Space Station

The overall design and the instrumental features of the Space-Station Observer for Nuclear Gamma-ray Spectroscopy (SONGS) instrument are described. SONGS comprises an array of 19 two-segment n-type Ge detectors, which have the capability of determining the interaction site in either the upper or the lower segment or in both segments. The detectors provide high energy resolution of 1 keV at 100 keV and of 2 keV at 1 MeV. The close-packed Ge sensor array provides a natural sensitivity for the measurement of gamma ray polarization in the 100 keV to 1 MeV energy range, making it possible to obtain information on the structure of the magnetosphere of neutron stars and of the accretion disk of black holes.

Nakano, G. H.↗

Development and testing of a prototype mosaic wedge-and-strip anode detector

A preliminary laboratory study of a prototype mosaic wedge-and-strip anode, a new class of readout system that will furnish large format, high resolution microchannel plate detectors with comparatively simple readout electronics is described. The goals of this study were to demonstrate the linearity of the mosaic anode algorithm, and to verify the predicted resolution performance in a realistic detector configuration. It is found that the nonlinearity introduced at the boundary between two anodes is limited to 50-100 microns. It is also shown that the spatial resolution of the detector is limited mainly by partition noise to about 35 microns (FWHM) at a gain of 2 x 10 to the 7th. A systematic investigation of the charge distribution arriving at the anode is also described. Using the relative charges arriving on the two anodes of the mosaic pattern, the detailed shape of the distribution and its dependence on MCP-anode voltage, MCP voltage, and pulse height are determined. A significant dependence of the profile on pulse height, which can introduce a pulse height dependence to the centroid calculation, particularly near the anode edges is found. Improved anode designs which will achieve the optimal performance are discussed.

Rasmussen, A.↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗

Measuring glass abundances in lunar agglutinates

The purpose of this study is to develop a standard method for measuring modal abundances of glass in single agglutinates in the lunar regolith. Not only does agglutinitic glass increase in single agglutinates as clasts of older agglutinates get incorporated into newer agglutinates with increasing maturity, but it is in this glassy phase that nanophase superparamagnetic Fe metal originates as a result of reduction reactions during the agglutination process. We report the results of two sets of independent measurements using two different methods to determine the proportion of glass in single agglutinates. We have used polished grain mounts (PGM) of five hand-picked single agglutinates from Apollo 16 soil 61181. The ISI Scanning Electron Microscope (SEM) fitted with a high-resolution Backscattered Electron (BSE) detector was used to collect high-contrast BSE images of the agglutinates. Several images were collected to represent each single agglutinate. The contrast, brightness, and focus were adjusted to optimize each image collected. Histograms of the grayscale range for all images produced four 'peaks' corresponding to epoxy, glass, crystalline phases, and metal grains. We analyzed every grid point for 12 elements with a less than 1 micron electron beam using a CAMECA SX-50 electron probe microanalyzer (EPM). If any analysis was not within about 10% of the stoichiometry of a known lunar mineral, we considered that point to be nonmineralic. Our results show that there is a remarkable correspondence in the glass percentages obtained by the two methods. The EPM method may overestimate glass because secondary fluorescence from dusty clasts in agglutinitic glass can give the appearance of nonmineralic targets. The BSE method may underestimate glass because the diversity of compositions of agglutinitic glass may not be contained under one grayscale 'peak' during image analysis.

Strait, M. M.↗

Hard X-Ray Telescope (HXT) with Simultaneous Multiwavelength Observing from UV to 1 MeV

The scientific instrumentation associated with this study includes three coaligned telescope systems: an array of grazing incidence telescopes with graded d-spacing multilayers to enhance reflectivity above 10 keV and a compound detector in their focal planes that covers the 0.1 to 100 keV band; a single laue crystal telescope that concentrates selected narrow regions in the 150 to 1300 keV bands containing interesting lines onto a cooled segmented high energy resolution germanium detector; and an array of three small UV telescopes with detectors and filters to isolate various bands in the 1000 to 2500 A region. The principal objectives of the study is to define what technology developments are required for these instruments to be built, refine the specifications of each instrument component, and identify what type of mission is needed for an HXT observatory. One key question is whether this set of instruments should be located together as an ensemble observing simultaneously aboard a single dedicated mission or distributed among multiple missions with other instrumentation.

Goenstein, Paul↗

High time-resolution imaging with the MAMA detector systems

Current uses of the MAMA detector which utilize the photon time-tagging capabilities of these detectors are reported. These applications currently include image stabilization by means of post-processing corrections of platform drift and speckle interferometry. The initial results of a sounding rocket experiment to obtain UV images of NGC 6240 and results from speckle interferometry of Neptune's moon Triton are presented.

Morgan, Jeffrey S.↗

VETA-1 x ray detection system

The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.

Podgorski, W. A.↗

Simple model for scanning-angle distribution of planetary albedo gamma-rays.

The planetary atmosphere is scanned from a satellite located at a point at an altitude of 500 km from the subsatellite point on the surface (the altitude of the satellite OSO-3). Results point out the possibility that by scanning a planet from the subsatellite point to the limb with a high resolution gamma ray detector on an orbiting satellite, the mean total baryonic scale height may be unfolded from the angular distribution of the gamma-ray flux without having to determine chemical composition and temperature.

Stecker, F. W.↗

Modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz

A sounding rocket-borne electron detector of high time resolution is used to search for modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz and energy range 5-7 keV. Data were telemetered to ground via a 93-kHz subcarrier. A cross-correlation analysis of the data collected indicates low-level modulation near the detection threshold of the instrument. Two U-1 events are observed which are interpreted as indications of modulation. The two modulation events occur during a period of increasing flux for a region marking the boundary between two current sheets detected by the payload magnetometer. The strongest argument against interference contamination is the lack of any observable modulation at times other than those mentioned in the study.

Spiger, R. J.↗

Proposal to National Aeronautics and Space Administration for continuation of a grazing incidence imaging telescope for X-ray astronomy using sounding rockets

The construction of a high resolution imaging telescope experiment payload suitable for launch on an Astrobee F sounding rocket was proposed. Also integration, launch, and subsequent data analysis effort were included. The payload utilizes major component subassemblies from the HEAO-B satellite program which were nonflight development units for that program. These were the X ray mirror and high resolution imager brassboard detector. The properties of the mirror and detector were discussed. The availability of these items for a sounding rocket experiment were explored with the HEAO-B project office.

Murray, B.↗

Space Telescope Digicon

The Digicon, chosen by NASA as the detector for the High Resolution Spectrograph (HRS) and the Faint Object Spectrograph (FOS) is a 512 parallel output channel vacuum photodetector. There are two HRS Digicons with spectral sensitivity ranges from 1050 A to 1800 A and 1150 A to 3000 A respectively, and two FOS Digicons, which have spectral ranges extending to 7000 A. The significant requirements for these devices are 0.01 counts per second background count rate per diode, state-of-the-art Digicon pulse height resolution (typical 15%) and a high degree of imaging precision and stability. The results of a manufacturing and test program to develop the Digicons coupled with extensive prior work has shown that these requirements can be met. The Digicon because of its inherent ruggedness is particularly well suited to space applications.

Alting-Mees, H. R.↗