Search NASA⌕ Search

SEARCH · Search NASA

Results for “high throughput sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

High throughput battery failure experimental platform

Addressing the need to increase the sample set to understand the causes of lithium battery thermal runaway, we conceived of an experimental platform with capability to increase the number of runaway experiments (currently 3-5 per week), while also collecting detailed electrochemical impedance spectroscopy measurements (EIS). Once expanded, the platform would enable data collection on 10s to 100s of cells that all experience runaway, thereby creating a statistical database necessary to identify early indication of risk. A primary containment unit to house cylindrical cells of variety NMC811 and of size 21700 (21 mm diameter by 70 mm length) was designed with features such as debris containment, preloaded cells in an exchangeable port, nitrogen ventilation, and exhaust containment. We performed the first overcharge abuse experiments of several 21700 cells, handpicked because of different initial EIS, and demonstrated that EIS changes dramatically during early stages of overcharge, but in a different manner than previous pouch cell experiments. The abuse experiments also revealed the discharge pattern and debris field created during runaway, as well as the cell temperature control and overheat, that must be considered in the primary containment apparatus. We designed and built a switching relay system to permit measurement of EIS without an active charging circuit, and created instrument control software for charging, EIS, and cell temperature control. The late-start funding was insufficient to fully construct the primary containment unit, but the foundational design and knowhow is available for any future work.

25 ENERGY STORAGE↗

RT-QuIC detection of chronic wasting disease prion in platelet samples of white-tailed deer

Chronic wasting disease (CWD) is a prion disease of captive and free-ranging cervids. Currently, a definitive diagnosis of CWD relies on immunohistochemistry detection of PrP Sc in the obex and retropharyngeal lymph node (RPLN) of the affected cervids. For high-throughput screening of CWD in wild cervids, RPLN samples are tested by ELISA followed by IHC confirmation of positive results. Recently, real-time quacking-induced conversion (RT-QuIC) has been used to detect CWD positivity in various types of samples. To develop a blood RT-QuIC assay suitable for CWD diagnosis, this study evaluated the assay sensitivity and specificity with and without ASR1-based preanalytical enrichment and NaI as the main ionic component in assay buffer. A total of 23 platelet samples derived from CWD-positive deer (ELISA +/IHC +) and 30 platelet samples from CWD-negative (ELISA-) deer were tested. The diagnostic sensitivity was 43.48% (NaCl), 65.22% (NaI), 60.87% (NaCl-ASR1) or 82.61% (NaI-ASR1). The diagnostic specificity was 96.67% (NaCl), 100% (NaI), 100% (NaCl-ASR1), or 96.67% (NaI-ASR1). The probability of detecting CWD prion in platelet samples derived from CWD-positive deer was 0.924 (95% CRI: 0.714, 0.989) under NaI-ASR1 experimental condition and 0.530 (95% CRI: 0.156, 0.890) under NaCl alone condition. The rate of amyloid formation (RFA) was greatest under the NaI-ASR1 condition at 10 -2 (0.01491, 95% CRI: 0.00675, 0.03384) and 10 -3 (0.00629, 95% CRI: 0.00283, 0.01410) sample dilution levels. Incorporation of ASR1-based preanalytical enrichment and NaI as the main ionic component signifcantly improved the sensitivity of CWD RT-QuIC on deer platelet samples. Blood test by the improved RT-QuIC assay may be used for antemortem and postmortem diagnosis of CWD.

59 BASIC BIOLOGICAL SCIENCES↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-target RNA depletion strategy to improve sensitivity of next-generation sequencing for the detection of RNA viruses in poultry

PCR-based assays have become the benchmark for detecting pathogens of poultry and other livestock; however, these techniques are limited in their ability to detect multiple infecting agents, provide limited genetic information on the pathogen, and, for RNA viruses, must be reviewed frequently to assure high sensitivity and specificity. In contrast, untargeted, high-throughput sequencing can rapidly detect all infecting agents in a sample while providing genomic sequence information to allow more in-depth characterization of viruses. Although next-generation sequencing (NGS) offers many advantages, one of its primary limitations is low sensitivity to pathogens given the abundance of host and other non-target sequences in sequencing libraries. We explored methods for improving the sensitivity of NGS to detect respiratory and enteric viruses in poultry from RNA extracts of swab samples. We employed commercial and custom-designed negative enrichment strategies to selectively deplete the most abundant rRNA reads from the host and non-target bacteria; host RNA was diminished from up to 40% of total reads to as low as 3%, and the total number of reads assigned to abundant bacterial classes were reduced greatly. Our treatment resulted in up to a 700-fold increase in the number of viral reads, detection of a greater number of viral agents, and higher average genome coverage for pathogens. Depletion assays added only 2 h to the NGS library preparation workflow. Custom depletion probe design offered significant cost savings (US$7–12 per sample) compared to commercial kits (US$30–50 per sample).

Parris, D. Joshua↗

Abundance of Major Cell Wall Components in Natural Variants and Pedigrees of Populus trichocarpa

The rapid analysis of biopolymers including lignin and sugars in lignocellulosic biomass cell walls is essential for the analysis of the large sample populations needed for identifying heritable genetic variation in biomass feedstocks for biofuels and bioproducts. In this study, we reported the analysis of cell wall lignin content, syringyl/guaiacyl (S/G) ratio, as well as glucose and xylose content by high-throughput pyrolysis-molecular beam mass spectrometry (py-MBMS) for >3,600 samples derived from hundreds of accessions of Populus trichocarpa from natural populations, as well as pedigrees constructed from 14 parents (7 × 7). Partial Least Squares (PLS) regression models were built from the samples of known sugar composition previously determined by hydrolysis followed by nuclear magnetic resonance (NMR) analysis. Key spectral features positively correlated with glucose content consisted of m/z 126, 98, and 69, among others, deriving from pyrolyzates such as hydroxymethylfurfural, maltol, and other sugar-derived species. Xylose content positively correlated primarily with many lignin-derived ions and to a lesser degree with m/z 114, deriving from a lactone produced from xylose pyrolysis. Models were capable of predicting glucose and xylose contents with an average error of less than 4%, and accuracy was significantly improved over previously used methods. The differences in the models constructed from the two sample sets varied in training sample number, but the genetic and compositional uniformity of the pedigree set could be a potential driver in the slightly better performance of that model in comparison with the natural variants. Broad-sense heritability of glucose and xylose composition using these data was 0.32 and 0.34, respectively. In summary, we have demonstrated the use of a single high-throughput method to predict sugar and lignin composition in thousands of poplar samples to estimate the heritability and phenotypic plasticity of traits necessary to develop optimized feedstocks for bioenergy applications.

09 BIOMASS FUELS↗

Advanced techniques in automated high-resolution scanning transmission electron microscopy

Scanning transmission electron microscopy is a common tool used to study the atomic structure of materials. It is an inherently multimodal tool allowing for the simultaneous acquisition of multiple information channels. Despite its versatility, however, experimental workflows currently rely heavily on experienced human operators and can only acquire data from small regions of a sample at a time. Here, we demonstrate a flexible pipeline-based system for high-throughput acquisition of atomic-resolution structural data using an all-piezo sample stage applied to large-scale imaging of nanoparticles and multimodal data acquisition. As a result, the system is available as part of the user program of the Molecular Foundry at Lawrence Berkeley National Laboratory.

4D-STEM↗

Statistical 3D morphology characterization of vaterite microspheres produced by engineered Escherichia coli

Hollow vaterite microspheres are important materials for biomedical applications such as drug delivery and regenerative medicine owing to their biocompatibility, high specific surface area, and ability to encapsulate a large number of bioactive molecules and compounds. We demonstrated that hollow vaterite microspheres are produced by an Escherichia coli strain engineered with a urease gene cluster from the ureolytic bacteria Sporosarcina pasteurii in the presence of bovine serum albumin. We characterized the 3D nanoscale morphology of five biogenic hollow vaterite microspheres using 3D high-angle annular dark field scanning transmission electron microscopy (HAADF-STEM) tomography. Using automated high-throughput HAADF-STEM imaging across several sample tilt orientations, we show that the microspheres evolved from a smaller more ellipsoidal shape to a larger more spherical shape while the internal hollow core increased in size and remained relatively spherical, indicating that the microspheres produced by this engineered strain likely do not contain the bacteria. The statistical 3D morphology information demonstrates the potential for using biogenic calcium carbonate mineralization to produce hollow vaterite microspheres with controlled morphologies.

3D morphology↗

Deep Learning for Rapid Analysis of Spectroscopic Ellipsometry Data

High‐throughput experimental approaches to rapidly develop new materials require high‐throughput data analysis methods to match. Spectroscopic ellipsometry is a powerful method of optical properties characterization, but for unknown materials and/or layer structures the data analysis using traditional methods of nonlinear regression is too slow for autonomous, closed‐loop, high‐throughput experimentation. Herein, three methods (termed spectral, piecewise, and pointwise) of spectroscopic ellipsometry data analysis based on deep learning are introduced and studied. After initial training, the incremental time for inferring optical properties can be a thousand times faster than traditional methods. Results for multilayer sample structures with optically isotropic materials are presented, appropriate for high‐throughput studies of thin films of phase‐change materials such as GeSbTe (GST) alloys. Results for studies on highly birefringent layered materials are also presented, exemplified by the transition metal dichalcogenide MoS 2 . How the materials under test and the experimental objectives may guide the choice of analysis methods are discussed. The utility of our approach is demonstrated by analyzing data measured on a composition spread of GeSbTe phase‐change alloys containing 177 distinct compositions, and identifying the composition with optimal phase‐change figure of merit in only 1.4 s of analysis time.

Li, Yifei↗

Spatial Proteomics towards cellular Resolution

Introduction: Spatial biology is an emerging interdisciplinary field facilitating biological discoveries through the use of spatial omics technologies. Recent advancements in spatial transcriptomics, spatial genomics (e.g. genetic mutations and epigenetic marks), multiplexed immunofluorescence, and spatial metabolomics/lipidomics have enabled high-resolution spatial profiling of gene expression, genetic variation, protein expression, and metabolites/lipids profiles in tissue. These developments contribute to a deeper understanding of the spatial organization within tissue microenvironments at the molecular level. Areas covered: This report provides an overview of the untargeted, bottom-up mass spectrometry (MS)-based spatial proteomics workflow. It highlights recent progress in tissue dissection, sample processing, bioinformatics, and liquid chromatography (LC)-MS technologies that are advancing spatial proteomics toward cellular resolution. Expert opinion: The field of untargeted MS-based spatial proteomics is rapidly evolving and holds great promise. To fully realize the potential of spatial proteomics, it is critical to advance data analysis and develop automated and intelligent tissue dissection at the cellular or subcellular level, along with high-throughput LC-MS analyses of thousands of samples. In conclusion, achieving these goals will necessitate significant advancements in tissue dissection technologies, LC-MS instrumentation, and computational tools.

59 BASIC BIOLOGICAL SCIENCES↗

A High-Throughput Method to Define Additive Manufacturing Process Parameters: Application to Haynes 282

This paper demonstrates how an analytical and experimental method can be used to rapidly define the 45 additive manufacturing settings for a new alloy where the process parameters were previously unknown. A nickel-based superalloy, Haynes 282, was chosen for the analysis. An experimental matrix of focused processing parameters was predicted with a dimensionless number and 100 samples were printed using the Selective Laser Melting technique. High-throughput measurements validated the predicted process conditions needed to achieve desired density and hardness. The whole process was completed in 16 hours. The new technique was confirmed with analytical processing maps adopted by the metal additive manufacturing community. With the predicted set of process parameters, microstructural characterizations and tensile testing were used to confirm the predictions. The resultant as-fabricated microstructures have refined length scales of both microsegregation and secondary phase distributions. As a result, the mechanical properties were comparable within the predicted processing window and exhibited high strength and high ductility.

Laser Material Processing↗

Automated High‐Throughput Fatigue Testing of Freestanding Thin Films

Abstract Mechanical testing at small length scales has traditionally been resource‐intensive due to difficulties with meticulous sample preparation, exacting load alignments, and precision measurements. Microscale fatigue testing can be particularly challenging due to the time‐intensive, tedious repetition of single fatigue experiments. To mitigate these challenges, this work presents a new methodology for the high‐throughput fatigue testing of thin films at the microscale. This methodology features a microelectromechanical systems‐based Si carrier that can support the simultaneous and independent fatigue testing of an array of samples. To demonstrate this new technique, the microscale fatigue behavior of nanocrystalline Al is efficiently characterized via this Si carrier and automated fatigue testing with in situ scanning electron microscopy. This methodology reduces the total testing time by an order of magnitude, and the high‐throughput fatigue results highlight the stochastic nature of the microscale fatigue response. This manuscript also discusses how this initial capability can be adapted to accommodate more samples, different materials, new geometries, and other loading modes.

Barrios, Alejandro↗

Optimization of stochastic feature properties in laser powder bed fusion

Process parameter selection in laser powder bed fusion (LPBF) controls the as-printed dimensional tolerances, pore formation, surface quality and microstructure of printed metallic structures. Measuring the stochastic mechanical performance for a wide range of process parameters is cumbersome both in time and cost. As such, in this study, we overcome these hurdles by using high-throughput tensile (HTT) testing of over 250 dogbone samples to examine process-driven performance of strut-like small features, ~1 mm 2 in austenitic stainless steel (316 L). The output mechanical properties, porosity, surface roughness and dimensional accuracy were mapped across the printable range of laser powers and scan speeds using a continuous wave laser LPBF machine. Tradeoffs between ductility and strength are shown across the process space and their implications are discussed. While volumetric energy density deposited onto a substrate to create a melt-pool can be a useful metric for determining bulk properties, it was not found to directly correlate with output small feature performance.

316 L stainless steel↗

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]↗

Correlation of Diffusion Limited Oxidation to Color Difference in Accelerated Aging of Electrical Cable Insulation

Diffusion limited oxidation (DLO) as a phenomenon has complicated material lifetime predictions from accelerated aging studies. Many methods to analyze DLO have been developed in recent years. However, an analytical tool for high throughput and low-cost analysis of DLO affected samples remains absent from the literature. Color differences in polymers exposed to oxidative conditions have recently been observed and correlated to increased concentrations of oxidation products. Herein, total color difference was utilized to rapidly quantify DLO in ethylene propylene rubber (EPR) polymeric cable insulation specimens. Insulation specimens were aged at 121 °C, 136 °C, 150 °C, and 165 °C and a 10% ?E*ab difference between the specimen edge and specimen center was used as the threshold for DLO. Based on these specifications DLO was observed in EPR insulation specimen at temperatures of 136 °C and above, with an increasing degree of DLO observed as the time of exposure increased. The method presented in this work represents a quantitative and high-throughput method for the investigation of DLO with a low cost barrier for entry.

diffusion limited oxidation, DLO, nuclear, electri↗

High throughput, spatially resolved thermal properties measurement using attachable and reusable 3ω sensors

The 3ω method is a well-established thermal technique used to measure the thermal conductivity of materials and the thermal resistance of interfaces. It has significant advantages over other steady state and transient thermal techniques in its ability to provide spatially resolved thermal property measurements over a wide range of thermal conductivity. Despite its advantages, it has been restricted to lab-scale use because of the difficulty involved in sample preparation and sensor fabrication and is limited to non-metallic substrates. High-throughput 3ω measurements with reusable sensors have not been realized yet. In this work, we demonstrate a method of applying reusable 3ω sensors fabricated on flexible polyimide films to measure bulk and spatially resolved thermal properties. Here, we establish the limits of thermal conductivity measurement with the method to be 1 to 200 W/mK, and within the measurement limit, we verify the method by comparing the measured thermal conductivities of standard samples with established values. From the 3ω measurements, we also determine the thermal resistance of an interlayer of thermal grease as a function of pressure and compare it against the resistance calculated from direct thickness measurements to demonstrate the ability of this method to provide spatially resolved subsurface information. The technique presented is general and applicable to both metallic and non-metallic substrates, providing a method for high-throughput 3ω measurements with reusable sensors and without considerable sample preparation.

47 OTHER INSTRUMENTATION↗

A Six-Membered Concerted Mechanism for CO 2 Capture by Amines Studied under Charged Microdroplet Reaction Conditions

Carbon dioxide (CO 2 ) capture and storage represents an important technological challenge. A mechanistic understanding of interactions involved in the capture process is necessary not only for technological development but also for efficient conversion of captured CO 2 into value-added materials. Herein, we present a novel contained secondary electrospray ionization platform for studying the interactions of gaseous amines and CO 2 gas under microdroplet reaction conditions, which enables mass spectrometry (MS) characterization of CO 2 capture products and intermediates in real time. We detected [2 M + CO 2 + H] + species, which corresponds to a six-membered intermediate. DFT calculations confirmed the high stability of the protonated six-membered ring intermediate. This finding provides a plausible concerted mechanism in the microdroplet environment that excludes the involvement of thermodynamically disfavored ionic species. The carbamic acid counterpart of the final product/salt was readily characterized by tandem MS. The carbamic acid/amine salt was also isolated and characterized by Fourier transform infrared spectroscopy. By virtue of the fact that headspace vapors of amines are sampled, we were able to establish a high-throughput platform that enabled the CO 2 capture capacity of five different amines to be studied in under 2 min. The same device also enabled the absolute quantification of capture capacity.

Amines↗