Search NASA⌕ Search

SEARCH · Search NASA

Results for “hourly loss of load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

90 records · Page 5

Deep reinforcement learning assisted co-optimization of Volt-VAR grid service in distribution networks

With the increasing penetration of distributed energy resources in distribution networks, Volt-VAR control and optimization (VVC/VVO) have become very important to ensure an acceptable quality of service to all customers. System operators can rely on slow-responding utility devices, including capacitor banks and on-load tap changing transformers, along with fast-responding battery and photovoltaic (PV) inverters for the VVC/VVO implementation. Because of variations in response time of these two classes of devices, and different control actions (discrete versus continuous), coordinated and optimal scheduling and operation have become of utmost importance. Here, this paper develops a look-ahead deep reinforcement learning (DRL)-based multi-objective VVO technique to improve the voltage profile of active distribution networks, decrease network and inverter power loss, and save the operational cost of the grid. It proposes a deep deterministic policy gradient (DDPG)-based approach to schedule the optimal reactive and/or active power set-points of fast-responding inverters, and a deep Q-network (DQN)-based DRL agent to schedule the discrete decisions variables of slow-responding assets. The reactive power output of PV and battery smart inverters are scheduled at 30-minute intervals and the capacitors’ commitment status is scheduled with several hour intervals. The proposed framework is validated on the modified IEEE 34-bus and 123-bus test cases with embedded PV and PV-plus-storage. To validate the efficacy of the proposed VVO, it is compared with several scenarios, including the base case without VVO, localized droop control of DERs, DDPG-only, and twin delayed DDPG (TD3) agent-based DRL techniques. The results justify the superior performance of the proposed method to improve the voltage profile, reduce network power loss, and minimize the look-ahead grid operational cost while minimizing the undesirable power losses in inverters as a result of power factor adjustments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Palladium/Zeolite Low Temperature Passive NOx Adsorbers (PNA): Structure-Adsorption Property Relationships for Hydrothermally Aged PNA Materials

Zeolites with different framework structures (SSZ-13, ZSM-5, BEA) but similar Si/Al ratios and Pd loading (~1 wr%) were synthesized and evaluated as low temperature passive NOx adsorbers (PNA). These materials exhibit high NOx adsorption efficiency with atomically dispersed Pd the active adsorption site. Hydrothermal aging at 750 ºC for 16 hours in the presence of 10% water vapor in air resulted in the formation of PdO nanoparticles in all three samples as evidenced by high energy XRD. Hydrothermal aging of the small-pore Pd/SSZ-13 (Si/Al = 6), which contain ~100-90% atomically dispersed palladium ions, decreases its PNA performance only by ~10-20%. High-field solid state 27Al NMR studies on the fresh and aged samples substantiate dealumination and significant changes in the distribution of Al (and thus, Bronsted acid) sites after hydrothermal aging. FTIR measurements with NO probe molecule and titration of Bronsted acid sites with nitrosyl (NO+) ions further corroborate the 27Al NMR data. Because framework aluminum atoms are the anchoring sites for atomically dispersed Pd ions, their elution from the framework causes the loss of active atomically dispersed Pd species. Furthermore, with the aid of HAADF-STEM imaging and synchrotron XRD studies, we further confirm and visualize the fate of these Pd species – they agglomerate into PdO nanoparticles on the external surface of zeolite. Consequently, these changes lead to the decrease in PNA performance of these materials after hydrothermal aging. The thus formed agglomerates cannot be re-dispersed back to their ionic state due to the loss of framework Al T-sites and/or inherent stability of such large PdO particles. Our study clearly demonstrates that, unlike in previous studies that found increased PNA performance upon HTA , high temperatures hydrothermal aging of PNA materials that contain atomically dispersed Pd initially, results in a decrease in NOx storage efficiency due mostly to the formation of PdO agglomerates. However, we also highlight the high hydrothermal stability of predominantly atomically dispersed 1-3 wt% Pd/SSZ-13 (Si/Al = 6), whose performance decreases only marginally after prolonged hydrothermal aging at 750 ºC. Overall, this study shows that hydrothermally stable passive NOx materials can be prepared using small-pore SSZ-13 zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CEM MARS 6 Microwave Incident

A fire occurred in a CEM MARS 6 analytical microwave during microwave-assisted, acid digestion of a soil sample in a Research and Development (R&D) laboratory. The soil sample had been pretreated at 550°C for approximately 4 hours in a furnace prior to digesting in the microwave. Less than 1-gram aliquots of the pretreated soil sample were placed into separate microwave reaction vessels along with an acid mixture used for digestion. The microwave was used to facilitate digestion of the samples. Microwave reaction vessels were loaded with acid and soil samples, sealed in cassettes, and the cassettes placed onto a microwave carousel. A temperature probe that senses the reaction temperature during the run was inserted into the Reference Cell thermowell. The contents of the Reference Cell were identical to the contents of the other reaction cells. The researcher initiated the run and then left the laboratory to perform other work. Upon returning to check the digestion run, flames and smoke were observed originating from the microwave. The researcher exited the lab, immediate emergency actions were taken, and the local fire department responded and extinguished the fire. No personnel were injured, and no facility structural damage occurred. The affected microwave is a total loss. The fire investigation revealed the most credible cause of the fire is an incompatible temperature probe that did not accurately measure temperature of the liquid phase of the Reference sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Efficient Entropic Recycling by Mastering Ring–Chain Kinetics

Traditional chemical recycling approaches for condensation polymers suffer compounding energy losses and CO 2 emissions across multiple polymerization and depolymerization cycles. Entropic recycling can address these energy losses by entrapping free energy within the deconstruction products. Entropic recycling involves depolymerization to macrocyclic monomers, but such processes have not been feasible due to the high dilutions typically required to generate macrocyclic compounds. Here, we leverage selective catalysis to allow entropic recycling at concentrations 20–2000× higher than typical for macrocyclization reactions. We find that Ru-based olefin metathesis catalysts containing bulky iodine ligands significantly bias the ring–chain kinetic product distribution during ring-closing metathesis (RCM) toward the formation of oligomeric cycloalkenes. Further improvements in reaction concentration and macrocycle yield are obtained by using high catalyst loadings and by predisposing the alkene substrates to undergo favorable macrocyclization. These RCM optimizations translate effectively to cyclodepolymerization (CDP) of an olefin-containing polymer, with RCM and CDP affording similar macrocycle product distributions under identical reaction conditions. Macrocycle polymerization by entropy-driven ring-opening metathesis provides much higher molecular weight polymers than condensation polymerization of linear analogues, reducing the time to achieve high molecular weight from hours to minutes and enabling polymerization at room temperature. Finally, our findings re-emphasize the importance of energy consumption during a polymer’s lifecycle and provide a framework for the design of efficient entropic recycling systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chapter 4: Physically informed deep learning networks for simulating microstructure evolution of 3D polycrystals

As discussed in the previous chapter, high energy diffraction microscopy (HEDM) is used to study the micromechanical evolution of a material during in situ loading. HEDM experiments have been used to verify crystal plasticity (CP) simulations [119, 91, 90, 120], for experimental planning, material design, and to further analyze experimental results. However, Fast Fourier transform-based CP (CP-FFT) or finite element-based CP (CP-FE) methods are often too slow to be used in real-time during an experiment. CP-FFT is faster than CP-FE simulations due to the absence of meshing, but can still take hours to simulate the response of a single volume depending on the size and number of strain steps [127]. Reducing computation time would create a larger exploration space in planning and design, and enable faster analysis of experimental results and real-time feedback during an experiment. This research expands upon previous works to develop a workflow for predicting the full-field evolution of a 3D polycrystal. The workflow is simplified from previous works to predict only orientation and elastic strain tensors (from which stress tensors are calculated). The network is physically informed through loss functions and network architecture for a more robust model. The orientation predictions are informed about the cubic crystal symmetry of the material by incorporating disorientation and misorientation information into the network architecture and loss. The Von Mises stress is used to enforce the correct stress-strain trends in the strain tensor predictions. Additional total strain steps from the elastic and elastoplastic region are included to better capture the stress-strain evolution at smaller total strain steps. Material and hardening parameters are additional inputs into the networks to further inform the network and to study the network’s ability to predict different materials other than those used for training.

36 MATERIALS SCIENCE↗

Investigating the Simulink Auto-Coding Process

Model based program design is the most clear and direct way to develop algorithms and programs for interfacing with hardware. While coding "by hand" results in a more tailored product, the ever-growing size and complexity of modern-day applications can cause the project work load to quickly become unreasonable for one programmer. This has generally been addressed by splitting the product into separate modules to allow multiple developers to work in parallel on the same project, however this introduces new potentials for errors in the process. The fluidity, reliability and robustness of the code relies on the abilities of the programmers to communicate their methods to one another; furthermore, multiple programmers invites multiple potentially differing coding styles into the same product, which can cause a loss of readability or even module incompatibility. Fortunately, Mathworks has implemented an auto-coding feature that allows programmers to design their algorithms through the use of models and diagrams in the graphical programming environment Simulink, allowing the designer to visually determine what the hardware is to do. From here, the auto-coding feature handles converting the project into another programming language. This type of approach allows the designer to clearly see how the software will be directing the hardware without the need to try and interpret large amounts of code. In addition, it speeds up the programming process, minimizing the amount of man-hours spent on a single project, thus reducing the chance of human error as well as project turnover time. One such project that has benefited from the auto-coding procedure is Ramses, a portion of the GNC flight software on-board Orion that has been implemented primarily in Simulink. Currently, however, auto-coding Ramses into C++ requires 5 hours of code generation time. This causes issues if the tool ever needs to be debugged, as this code generation will need to occur with each edit to any part of the program; additionally, this is lost time that could be spent testing and analyzing the code. This is one of the more prominent issues with the auto-coding process, and while much information is available with regard to optimizing Simulink designs to produce efficient and reliable C++ code, not much research has been made public on how to reduce the code generation time. It is of interest to develop some insight as to what causes code generation times to be so significant, and determine if there are architecture guidelines or a desirable auto-coding configuration set to assist in streamlining this step of the design process for particular applications. To address the issue at hand, the Simulink coder was studied at a foundational level. For each different component type made available by the software, the features, auto-code generation time, and the format of the generated code were analyzed and documented. Tools were developed and documented to expedite these studies, particularly in the area of automating sequential builds to ensure accurate data was obtained. Next, the Ramses model was examined in an attempt to determine the composition and the types of technologies used in the model. This enabled the development of a model that uses similar technologies, but takes a fraction of the time to auto-code to reduce the turnaround time for experimentation. Lastly, the model was used to run a wide array of experiments and collect data to obtain knowledge about where to search for bottlenecks in the Ramses model. The resulting contributions of the overall effort consist of an experimental model for further investigation into the subject, as well as several automation tools to assist in analyzing the model, and a reference document offering insight to the auto-coding process, including documentation of the tools used in the model analysis, data illustrating some potential problem areas in the auto-coding process, and recommendations on areas or practices in the current Ramses model that should be further investigated. Several skills were required to be built up over the course of the internship project. First and foremost, my Simulink skills have improved drastically, as much of my experience had been modeling electronic circuits as opposed to software models. Furthermore, I am now comfortable working with the Simulink Auto-coder, a tool I had never used until this summer; this tool also tested my critical thinking and C++ knowledge as I had to interpret the C++ code it was generating and attempt to understand how the Simulink model affected the generated code. I had come into the internship with a solid understanding of Matlab code, but had done very little in using it to automate tasks, particularly Simulink tasks; along the same lines, I had rarely used shell script to automate and interface with programs, which I gained a fair amount of experience with this summer, including how to use regular expression. Lastly, soft-skills are an area everyone can continuously improve on; having never worked with NASA engineers, which to me seem to be a completely different breed than what I am used to (commercial electronic engineers), I learned to utilize the wealth of knowledge present at JSC. I wish I had come into the internship knowing exactly how helpful everyone in my branch would be, as I would have picked up on this sooner. I hope that having gained such a strong foundation in Simulink over this summer will open the opportunity to return to work on this project, or potentially other opportunities within the division. The idea of leaving a project I devoted ten weeks to is a hard one to cope with, so having the chance to pick up where I left off sounds appealing; alternatively, I am interested to see if there are any opening in the future that would allow me to work on a project that is more in-line with my research in estimation algorithms. Regardless, this summer has been a milestone in my professional career, and I hope this has started a long-term relationship between JSC and myself. I really enjoy the thought of building on my experience here over future summers while I work to complete my PhD at Missouri University of Science and Technology.

Gualdoni, Matthew J.↗

On the nature and origin of the calcium asymmetry arising during gravitropic response in etiolated pea epicotyls

Seven day old etiolated pea epicotyls were loaded symmetrically with 3H-indole 3-acetic acid (IAA) or 45Ca2+, then subjected to 1.5 hours of 1g gravistimulation. Epidermal peels taken from top and bottom surfaces after 90 minutes showed an increase in IAA on the lower side and of Ca2+ on the upper side. Inhibitors of IAA movement (TIBA, 9-hydroxyfluorene carboxylic acid) block the development of both IAA and Ca2+ asymmetries, but substances known to interfere with normal Ca2+ transport (nitrendipine, nisoldipine, Bay K 8644, A 23187) do not significantly alter either IAA or Ca2+ asymmetries. These substances, however, are active in modifying both Ca2+ uptake and efflux through oat and pea leaf protoplast membranes. We conclude that the 45Ca2+ fed to pea epicotyls occurs largely in the cell wall, and that auxin movement is primary and Ca2+ movement secondary in gravitropism. We hypothesize that apoplastic Ca2+ changes during graviresponse because it is displaced by H+ secreted through auxin-induced proton release. This proposed mechanism is supported by localized pH experiments, in which filter paper soaked in various buffers was applied to one side of a carborundum-abraded epicotyls. Buffer at pH 3 increases calcium loss from the side to which it is applied, whereas pH 7 buffer decreases it. Moreover, 10 micromolar IAA and 1 micromolar fusicoccin, which promote H+ efflux, increase Ca2+ release from pea epicotyl segments, whereas cycloheximide, which inhibits H+ efflux, has the reverse effect. We suggest that Ca2+ does not redistribute actively during gravitropism: the asymmetry arises because of its release from the wall adjacent to the region of high IAA concentration, proton secretion, and growth. Thus, the asymmetric distribution of Ca2+ appears to be a consequence of growth stimulation, not a critical step in the early phase of the graviresponse.

NASA Discipline Number 40-10↗

Hydraulic Conductivity Measurements, Utqiagvik (Barrow), Alaska, 2014

Six individual ice cores were collected from the Barrow Environmental Observatory in Barrow, Alaska, in May of 2013 as part of the Next Generation Ecosystem Experiment (NGEE). Each core was drilled at a different location to varying depths. After drilling, the cores were stored in coolers packed with dry ice and flown to Lawrence Berkeley National Laboratory (LBNL) in Berkeley, CA. 3-dimensional images of the cores were constructed using medical X-ray computed tomography (CT) scanner at 120kV. Hydraulic conductivity samples were extracted from these cores at LBNL Richmond Field Station in Richmond, CA, in February 2014 by cutting 5 to 8 inch segments using a chop saw. Samples were packed individually and stored at -20C freezing temperatures to minimize any changes in structure or loss of ice content prior to analysis. Hydraulic conductivity was determined through falling head tests using a permeameter [ELE International, Model #: K-770B] (Appendix A). Samples were placed in a latex membrane via a membrane stretcher while frozen. Use of a membrane stretcher made the membranes easier to secure and minimized contact with the sample. A clear polycarbonate sleeve, fabricated with a stainless steel ring at the bottom to keep the sleeve from floating, was placed around the sample inside the permeameter to minimize deformation during analysis. The permeameter was filled with water and 1.0 PSI of air was applied for confining pressure during sample defrost. Outflow valves were left open to allow for incremental thawing and samples were left to thaw for approximately 12 hours. After approximately 12 hours of thaw, initial falling head tests were performed. When the flow was significantly too fast or too slow, the analysis was stopped and the burette size was adjusted accordingly (i.e. a larger diameter burette was used for flows that were faster than desired or a smaller diameter burette was used for flows that were slower than desired). Two to four measurements were collected on each sample and collection stopped when the applied head load exceeded 25% change from the original load. Analyses were performed between 2 to 3 times for each sample. The final hydraulic conductivity calculations were computed using methodology of Das et al., 1985.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

The Relationship between Workload, Performance and Fatigue in a Short-Haul Airline

Short-haul flights are associated with irregular work schedules and increased workload, due to frequent takeoffs and landings. We examined the relationship between pilot workload, performance and subjective fatigue during normal short-haul operations. Ninety airline pilots (8 female), mean age 33 (±8 years) completed a NASA-Task Load Index (NASA-TLX), a Psychomotor Vigilance Task (PVT; a reaction time test sensitive to sleep loss) and a Samn-Perelli (SP) fatigue scale, over a period of 20 duty days at top-of-descent on 2762 short-haul flights. The duty days included either 2 or 4 flights per day starting at different times as scheduled during normal operations. Workload was measured using the six NASA-TLX scales: mental demand, physical demand, temporal demand, effort, performance and frustration. Lapses (reaction times [RT] > 500ms) were calculated for the PVT. Spearman correlations were calculated to identify relationships between the NASA-TLX, PVT lapses, and SP. The six scales of NASA-TLX were positively correlated with the PVT lapses (p < 0.01) showing an increase in workload when lapses increased. There was a positive correlation between subjective fatigue as measured by the SP fatigue scale and each of the six scales of NASA-TLX (p < 0.001) suggesting that pilots reported higher workload when perceived levels of fatigue were higher. Of the six workload scales, mental demand and performance were rated the highest (mental: M = 40.99, SD = 20.32; performance: M = 41.61, SD = 20.71) and effort was rated the lowest (M = 15.59, SD = 8.98). Preliminary analyses suggest that high workload is associated with poorer PVT performance and increased self-reported fatigue in this population of short-haul pilots. Future studies should explore how other workload factors (i.e. flight hours, time of day) influence self-reported and objective fatigue measures.

TLX↗

Boride-Carbon Hybrid Technology to Produce Ultra-Wear and Corrosion Resistant Surfaces for Applications in Harsh Conditions (Final Technical Report)

Engineered functional surfaces play an important role to enable new products and manufacturing processes that can endure harsh service conditions such as high impact and contact loads, highly abrasive wear, extreme temperatures, and corrosive environments. Engineered surfaces can also be instrumental to improving the efficient use of energy by reducing frictional losses and extending service life. The main objective of this project was to develop a hybrid surface engineering technology that combines the advantages of a novel ultrafast boriding process with the next generation of superhard carbon coatings. The hypothesis was that this hybrid process will offer an unprecedented combination of wear and corrosion resistance, low frictional losses and affordability for treated parts so that it can be utilized in many applications. During this project, a duplex process was developed that combines the advantages of ultra-fast electrochemical boriding with those of hard tetrahedral amorphous carbon coatings. Both technologies can be combined to form a hybrid technology that is characterized by low friction and wear properties combined with corrosion and fatigue resistance. Good adhesion of both layers to each other was one main goal of this project, that has been achieved with HF1 adhesion through the Rockwell-C adhesion test. In this project, the mechanical properties of the hybrid coating were modeled through a finite-element analysis approach. We can conclude that the FEA model resembles the actual samples and be utilized to predict mechanical behavior under impacts. Based on this model, application-oriented load conditions can be simulated for optimal layer design regarding thickness and mechanical properties. To exemplify, one conclusion that can be drawn from the nanoindentation model is a boride layer thickness of 50 µm is sufficient to effectively support the carbon coating on the identified AISI 1045 low carbon steel substrate material. The duplex treatment yields wear rates as low as 6 x 10 -8 mm 3 N -1 m -1 and a coefficient of friction of 0.14 when tested against a steel counter face in a ball-on-disk test setup. On the other hand, the wear rate of the only-borided AISI 1045 steel was 5 x 10 -5 mm 3 N -1 m -1 , about three orders of magnitude higher than the duplex coating. At the same time, duplex treated samples experience corrosion resistance, which could not be achieved with single-layer carbon coatings. The developed surface treatment withstands a 3-hour exposure to 15% HCl, while the only carbon coated counter sample shows severe delamination of the coating due to pin hole corrosion. The boride layer is chemically stable and pin hole free because it is formed through an electrochemical process under high current densities (700 mA/cm 2 ) and high temperature. Additionally, the hybrid coating led to at least 3x increase in fatigue strength of the steel substrate, which exceeds the target performance of 30% improvement. There are numerous potential applications for the duplex coatings. A representative application is bearing ball coatings for off-shore windmills. Compared to currently employed surface technologies in this field, the initial costs of applying our technology might be higher due to more process steps but the performance benefits lead to an increased life time of treated parts, which will lower the maintenance and replacement costs in the long-term. To validate the technology for this specific application, the team is currently investigating the process of white etching crack initiation of the duplex coating in collaboration with ANL. Overall, this project successfully validated that the boride-carbon hybrid technology can withstand harsh conditions. One possible approach to commercialization under consideration is to transfer the technology to a startup or an existing coatings company.

36 MATERIALS SCIENCE↗

Effects of volume loading and pressor agents in idiopathic orthostatic tachycardia

BACKGROUND: Idiopathic orthostatic tachycardia (IOT) is characterized by an increase in heart rate (HR) with standing of > or = 30 bpm that is associated with elevated catecholamine levels and orthostatic symptoms. A dynamic orthostatic hypovolemia and alpha1-adrenoreceptor hypersensitivity have been demonstrated in IOT patients. There is evidence of an autonomic neuropathy affecting the lower-extremity blood vessels. METHODS AND RESULTS: We studied the effects of placebo, the alpha1-adrenoreceptor agonist midodrine (5 to 10 mg), the alpha2-adrenoreceptor agonist clonidine (0.1 mg), and I.V. saline (1 L) in 13 patients with IOT. Supine and upright blood pressure (BP) and HR were measured before and at 1 and 2 hours after intervention. Midodrine decreased both supine and upright HR (all HR values are given as bpm) at 2 hours (from 78+/-2 supine to 108+/-5 upright before treatment and from 69+/-2 supine to 95+/-5 upright after treatment, P<.005 for supine and P<.01 for upright). Saline decreased both supine and upright HR (from 80+/-3 supine to 112+/-5 upright before infusion and from 77+/-3 supine to 91+/-3 upright 1 hour after infusion, P<.005 for supine and P<.001 for upright). Clonidine decreased supine HR (from 78+/-2 to 74+/-2, P<.03) but did not affect the HR increase with standing. Clonidine very significantly decreased supine systolic BP (from 109+/-3 at baseline to 99+/-2 mm Hg at 2 hours, P<.001), and midodrine decreased supine systolic BP mildly. CONCLUSIONS: IOT responds best acutely to saline infusion to correct the underlying hypovolemia. Chronically, this can be accomplished with increased salt and water intake in conjunction with fludrocortisone. The response of patients to the alpha1-agonist midodrine supports the hypothesis of partial dysautonomia and indicates that the use of alpha1-agonists to pharmacologically replace lower-extremity postganglionic sympathetics is an appropriate overall goal of therapy. These findings are consistent with our hypothesis that the tachycardia and elevated catecholamine levels associated with IOT are principally due to hypovolemia and loss of adequate lower-extremity vascular tone.

Non-NASA Center↗

The value of wake steering wind farm flow control in US energy markets

Abstract. Wind farm flow control represents a category of control strategies for achieving wind-plant-level objectives, such as increasing wind plant power production and/or reducing structural loads, by mitigating the impact of wake interactions between wind turbines. Wake steering is a wind farm flow control technology in which specific turbines are misaligned with the wind to deflect their wakes away from downstream turbines, thus increasing overall wind plant power production. In addition to promising results from simulation studies, wake steering has been shown to successfully increase energy production through several recent field trials. However, to better understand the benefits of wind farm flow control strategies such as wake steering, the value of the additional energy to the electrical grid should be evaluated – for example, by considering the price of electricity when the additional energy is produced. In this study, we investigate the potential for wake steering to increase the value of wind plant energy production by combining model predictions of power gains using the FLOw Redirection and Induction in Steady State (FLORIS) engineering wind farm flow control tool with historical electricity price data for 15 existing US wind plants in four different electricity market regions. Specifically, for each wind plant, we use FLORIS to estimate power gains from wake steering for a time series of hourly wind speeds and wind directions spanning the years 2018–2020, obtained from the ERA5 reanalysis dataset. The modeled power gains are then correlated with hourly electricity prices for the nearest transmission node. Through this process we find that wake steering increases annual energy production (AEP) between 0.4 % and 1.7 %, depending on the wind plant, with average increases in potential annual revenue (i.e., annual revenue of production, ARP) 4 % higher than the AEP gains. For most wind plants, ARP gain was found to exceed AEP gain. But the ratio between ARP gain and AEP gain is greater for wind plants in regions with high wind penetration because electricity prices tend to be relatively higher during periods with below-rated wind plant power production, when wake losses occur and wake steering is active; for wind plants in the Southwest Power Pool – the region with the highest wind penetration analyzed (31 %) – the increase in ARP from wake steering is 11 % higher than the AEP gain. Consequently, we expect the value of wake steering, and other types of wind farm flow control, to increase as wind penetration continues to grow.

17 WIND ENERGY↗

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.

20 FOSSIL-FUELED POWER PLANTS↗

High-Temperature Active Magnetic Bearing Development for Supercritical CO 2 Machinery Applications

Hermetic machinery utilizing gas bearings for MW-scale supercritical CO 2 (sCO 2 ) machinery applications can have significantly lower power loss and enable improved cycle efficiency compared to conventional machinery with oil-lubricated bearings. Active magnetic bearings (AMBs) are another option anticipated to have similar power loss and load capacity to gas bearings as well as offering larger mechanical tolerances, the ability to tune properties, and high reliability due to lack of mechanical wear. AMBs also have proven commercial experience at MW-scale, though environments for high-temperature sCO 2 power cycle machinery conditions are novel. Besides the potential impact of AMBs for sCO 2 turbomachinery, the technology also offers promising benefits for steam and gas turbines for power generation, compressors and expanders for industrial heat and power, and in other oil and gas and space applications. The goals of this project were to conceptual design an AMB and perform material testing. Conceptual designs for radial and thrust AMBs were produced based on a hermetically-sealed sCO 2 machinery waste-heat recovery (WHR) application for sizing and loads, and choosing a target design temperature of 540°C useful for high-temperature sCO 2 turbines for concentrating solar power (CSP) applications. Conceptual designs were initially developed for multiple radial and thrust AMBs with spreadsheet-based calculations before selecting one of each to develop further using higher-fidelity design methods for magnetic and structural performance. It was found that the radial AMB at 540°C was feasible, but the thrust AMB needed to be limited to 315°C for high-speed operation. The decision for a reduced-temperature thrust AMB was the result of several significant conclusions: 1) Hiperco 50A, originally chosen for good magnetic performance at high temperature, had insufficient strength for high-speed operation, so it was replaced with 17-4 PH. 2) The reduced magnetic performance from 17-4 PH yielded a larger bearing size, reducing the strength margin. 3) This ultimately led to a creative design implementing a more-compact E-core topology, compared to the original (conventional) C-core, and an integral shaft-disk with Hirth joint connection. These conceptual designs are unique for the size and temperature in CO 2 , relevant for MW-scale CSP applications. Long term, high temperature test data was generated for several materials, filling a void in the current body of literature. Corrosion and magnetic performance measurements were produced for PM materials (Alnico 5-7C, Alnico 9C, and SmCo) with and without nickel-coating for environments of high-temperature CO 2 up to 550°C at atmospheric pressure and 450°C at 103 bar for up to 6,000 hours. Corrosion measurements were also produced for Hiperco 50, a SM material relevant for AMB laminations, with and without C5 coating. Comparisons were also made for 450°C and 550°C, atmospheric pressure air exposures up to 5,000 hours. Results generally show that coatings can be effective at improving oxidation resistance of the bare materials, and Alnicos generally outperformed SmCo after high-temperature exposure. In addition to technical feasibility demonstrated by the design, economic feasibility was demonstrated by updating the TEA from the reference machine, re-evaluating it with CAPEX and OPEX to reflect estimated changes from process-lubricated bearings to AMBs. AMBs were shown to be comparable in performance to process-lubricated bearings, still showing a notable improvement over conventional machinery architecture with oil-lubricated bearings.

42 ENGINEERING↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗