Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurements of upper troposheric humidity at low temperatures during CRYSTAL-FACE

Aircraft condensation trails (contrails) and thin cirrus were studied by instruments on the NASA WB-57F high-altitude aircraft during contrails and optically thing cirrus are contrasted by different levels of supersaturation with respect to ice. During the July 13, 2002, flight of the WB-57F aircraft intercepted visible contrails produced by both the WB-57F and ER-2 aircraft. These contrails were located immediately below the local tropopause, where ambient temperatures were very low (-76 degree C). The contrails were clearly indicated by an abrupt increase in NO and a simultaneous, abrupt decrease in ice supersaturation. With in the contrail, the relative humidity was close to 130% with respect to ice, higher than expected from theory. Outside the contrails was a persistent layer of subvisible currus extending from approximately 13 to 15 km altitude. This layer was characterized y significant supersaturations because the ambient concentrations of ice particles were insufficient to significantly deplete the ice supersaturation. We will discuss in situ measurements and models simulations of humidity.

water vapor↗

NASA Glenn Research Center, Propulsion Systems Laboratory: Plan to Measure Engine Core Flow Water Vapor Content

This presentation will be made at the 92nd AIAA Turbine Engine Testing Working Group (TETWoG), a semi-annual technical meeting of turbine engine testing professionals. The objective is to describe an effort by NASA to measure the water vapor content on the core airflow in a full scale turbine engine ice crystal icing test and to open a discussion with colleagues how to accurately conduct the measurement based on any previous collective experience with the procedure, instruments and nature of engine icing testing within the group. The presentation lays out the schematics of the location in the flow path from which the sample will be drawn, the plumbing to get it from the engine flow path to the sensor and several different water vapor measurement technologies that will be used: Tunable diode laser and infrared spectroscopy.

core flow humidity measurement↗

Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%–70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.

DESI↗

Mach-Number Measurement with Laser and Pressure Probes in Humid Supersonic Flow

Mach-number measurements using a nonintrusive optical technique, laser-induced thermal acoustics (LITA), are compared to pressure probes in humid supersonic airflow. The two techniques agree well in dry flow (-35 C dew point), but LITA measurements show about five times larger fractional change in Mach number than that of the pressure-probe when water is purposefully introduced into the flow. Possible reasons for this discrepancy are discussed.

Herring, G. C.↗

Space flight printed wiring board measling investigation

A flight printed wiring board (PWB) for a satellite project was observed to have a high incidence of measling. Other PWB's produced for the program by the same manufacturer did not exhibit the degree of measling as did the 'measle-prone' board. Measling susceptibility during hand soldering and measling effects on PWB insulation resistance were investigated for three production PWB's. Measling resistance was significantly different between the three boards: the 'worst' exhibited five times the number of measles as the 'best' board. 'Severe' measling (that which is likely to affect board reliability) did not exist on the 'best' board, even under extreme soldering conditions (399 degrees C for 12-15 sec.), whereas the 'worst' board showed an average of one 'severe' measle for every two pads under more normal soldering conditions (288-343 degrees C for 2-5 sec.). Both soldering time and temperature affected measling, with time having a slightly greater influence (2 percent versus 12 percent). Measling effects on PWB insulation resistance were inconclusive. These were evaluated by in situ resistance measurements on the same three boards at elevated temperature and humidity. The measured resistance for all three boards decreased for exposures greater than 50 degrees C and 50 percent relative humidity. The 'measle-prone' board showed a resistance decrease at only 25 degrees C and 50 percent relative humidity. However, no definitive difference was detected between measled and not-measled (control) samples. The boards evaluated were production boards, so the effect of interlayer traces connecting the plated-through holes was not controlled. It is likely the resistance measurements were over different volumes of PWB laminate, which would account for the widely varying resistances measured. Thermomechanical measurements on board laminate materials did not reveal any differences attributed to measling. Differences in glass transition temperature were significantly different when measured by DTA, but not by SDT. Laminate thermal expansion differences were significant for the 35 degrees C evaluations, but not for any higher temperatures.

Thomas, Walter B., III↗

The Impact of Upper Tropospheric Humidity from Microwave Limb Sounder on the Midlatitude Greenhouse Effect

This paper presents an analysis of upper tropospheric humidity, as measured by the Microwave Limb Sounder, and the impact of the humidity on the greenhouse effect in the midlatitudes. Enhanced upper tropospheric humidity and an enhanced greenhouse effect occur over the storm tracks in the North Pacific and North Atlantic. In these areas, strong baroclinic activity and the large number of deep convective clouds transport more water vapor to the upper troposphere, and hence increase greenhouse trapping. The greenhouse effect increases with upper tropospheric humidity in areas with a moist upper troposphere (such as areas over storm tracks), but it is not sensitive to changes in upper tropospheric humidity in regions with a dry upper troposphere, clearly demonstrating that there are different mechanisms controlling the geographical distribution of the greenhouse effect in the midlatitudes.

Hu, Hua↗

Comparison of upper tropospheric water vapor from GOES, Raman lidar, and Cross-chain Loran Atmospheric Sounding System measurements

Observations of upper tropospheric relative humidity obtained from Raman lidar and Cross-chain Loran Atmospheric Sounding System (CLASS) sonde instruments obtained during the First ISCCP Regional Experiment (FIRE) Cirrus-II field program are compared with satellite measurements from the GOES 6.7-micron channel. The 6.7-micron channel is sensitive to water vapor integrated over a broad layer in the upper troposphere (roughly 500-200 mbar). Instantaneous measurements of the upper tropospheric relative humidity from GOES are shown to agree to within roughly 6% of the nearest lidar observations and 9% of the nearest CLASS observations. The CLASS data exhibit a slight yet systematic dry bias in upper tropospheric humidity, a result which is consistent with previous radiosonde intercomparisons. Temporal stratification of the CLASS data indicates that the magnitude of the bias is dependent upon the time of day, suggesting a solar heating effect in the radiosonde sensor. Using CLASS profiles, the impact of vertical variability in relative humidity upon the GOES upper tropospheric humidity measurements is also examined. The upper tropospheric humidity inferred from the GOES 6.7-micron channel is demonstrated to agree to within roughly 5% of the relative humidity vertically averaged over the depth of atmosphere to which the 6.7-micron channel is sensitive. The results of this study encourage the use of satellite measurements in the 6.7-micron channel to quantitatively describe the distribution and temporal evolution of the upper tropospheric humidity field.

Soden, B. J.↗

Meteorological lidar developments

A research program on remote optical measurements of humidity and temperature is summarized, and new results are given of such measurements as well as new data on the near IR absorption spectrum of H2O. The basic atmospheric technique is differential absorption lidar (DIAL) using narrow band, tunable dye lasers. Approximate wavelengths are 720, 820, 940 nm (H2O) and 690, 760 nm (O2; temperature). The requisite absorption line strengths and widths are measured in a controlled environment by means of grating spectroscopy and tunable lasers. Prospects for routine lidar meteorology, even from airplane and satellite platforms, appear excellent in several important applications; the conditions and the optical properties of the atmosphere can be obtained remotely by these means.

Wilkerson, T. D.↗

CoSSIR: A New Instrument for Exploring the Utility of Submillimeter-wave Radiometry for Earth Observation

The Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) has been developed to study the application of submillimeter-wave radiometry for remote sensing of cirrus clouds and humidity sounding. Measurements of the global distribution of ice cloud mass and particle size are important for understanding the Earth s energy budget and for evaluating global climate models. The spatial variability and the wide variety of cloud particle shapes and sizes make ice clouds particularly difficult to measure. Ice clouds are essentially undetectable at microwave frequencies due to the low dielectric of ice and small size of the particles relative to wavelength. However, submillimeter wavelengths demonstrate significant response to the presence of ice clouds thus this frequency regime is applicable to measuring ice clouds. Another potentially viable application for submillimeter-wave radiometry is humidity and temperature sounding. The principle of sounding at submillimeter wavelengths is similar to that at microwavelengths. Submillimeter-wave radiometry has the advantage of achieving finer spatial resolution using a smaller antenna aperture which is an important consideration for spaceborne observatories. Submillimeter-wave radiometry also offers the potential of sounding over land and as a surrogate measurement for precipitation. CoSSIR is a new instrument to explore these applications. The CoSSIR is designed to fly aboard the ER-2 aircraft and its modest size (approximately 100 kg) permits it to be configured for other aircraft. A dual-axes gimbals mechanism provides conical, across-track, and along-track scanning capability. In its present configuration CoSSIR has fifteen channels between 183 GHz and 640 GHz. Three channels are centered about the 183 GHz water vapor absorption line, four channels are centered about the 380 GHz water vapor absorption line, and three dual-polarized channels are centered about the 487 GHz oxygen absorption line. Two channels are located in atmospheric windows at 220 GHz and 640 GHz. All channels are single-linear polarized with the exception of those near 487 GHz. Calibration is achieved by periodically observing two blackbody radiators; one blackbody is heated to approximately 325 K and the other is approximately 250 K during flight. Details of the instrument design as well as measurements from the Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment will be presented.

Racette, P. E.↗

Total Temperature Measurements using a Rearward Facing Probe in Supercooled Liquid Droplet and Ice Crystal Clouds

This paper presents an analysis of local total temperature and humidity experimental measurement taken in atmospheric ice cloud flows. The measurements were obtained in a series of tests in NASA's Propulsion Systems Laboratory. The probe used in the tests is referred to as the Rearward Facing Probe which was designed to mitigate the contamination effects of ice accretion and ingestion into the probe. The data provided important insights in the interaction of the ice cloud and the atmospheric flow. For the majority of the test runs, small temperature drops in the range of 0.6 to 2.8 C and up to 1.5 g/kg of water vapor rise were found as a result of the interaction. Under certain very low temperature or high TWC conditions, the interaction with the cloud produced a warming of the airflow. A thermal model based on evaporative and convective heat transfer mechanisms between the spray droplets and the airflow showed good agreement with the experimental data. Detailed analyses of the response of the probe under various flow, thermodynamic, and cloud conditions, are provided in the paper.

ice crystal↗

Electrochemical Measurement of Atmospheric Corrosion

Corrosion of Shuttle thruster components in atmospheres containing high concentrations of nitrogen tetroxide (NTO) and water is an important issue in ground operations of bipropellant systems in humid locations. Measurements of the corrosivities of NTO-containing atmospheres and the responses of different materials to these atmospheres have been accomplished using an electrochemical sensor. The sensor is composed of alternating aluminum/titanium strips separated by thin insulating layers. Under high humidity conditions a thin film of water covers the surface of the sensor. Added NTO vapor reacts with the water film to form a conductive medium and establishes a galvanic cell. The current from this cell can be integrated with respect to time and related to the corrosion activity. The surface layer formed from humid air/NTO reacts in the same way as an aqueous solution of nitric acid. Nitric acid is generally considered an important agent in NTO corrosion situations. The aluminum/titanium sensor is unresponsive to dry air, responds slightly to humid air (> 75% RH), and responds strongly to the combination of humid air and NTO. The sensor response is a power function (n = 2) of the NTO concentration. The sensor does not respond to NTO in dry air. The response of other materials in this type of sensor is related to position of the material in a galvanic series in aqueous nitric acid. The concept and operation of this electrochemical corrosion measurement is being applied to other corrosive atmospheric contaminants such as hydrogen chloride, hydrogen fluoride, sulfur dioxide, and acidic aerosols.

DeArmond, Anna H.↗

The Evolving Distribution of Relative Humidity Conditional Upon Daily Maximum Temperature in a Warming Climate

Abstract The impacts of heat waves in a warming climate depend not only on changing temperatures but also on changing humidity. Using 35 simulations from the Community Earth System Model Large Ensemble (CESM LENS), we investigate the long‐term evolution of the joint distribution of summer relative humidity (RH) and daily maximum temperature ( Tmax ) near four U.S. cities (New York City, Chicago, Phoenix, and New Orleans) under the high‐emissions Representative Concentration Pathway (RCP) 8.5. We estimate the conditional quantiles of RH given Tmax with quantile regression models, using functions of temperature for each city in July for three time periods (1990–2005, 2026–2035, and 2071–2080). Quality‐of‐fit diagnostics indicate that these models accurately estimate conditional quantiles for each city. As expected, each quantile of Tmax increases from 1990–2005 to 2071–2080, while mean RH decreases modestly. Conditional upon a fixed quantile of Tmax , the median and high quantiles of RH decrease, while those of the Heat Index (HI) and dew point both increase. This result suggests that, despite a modest decrease in median relative humidity, heat stress measured by metrics considering both humidity and temperature in a warming climate will increase faster than that measured by temperatures alone would indicate. For a fixed Tmax , the high quantiles of RH (and thus of HI and dew point) increase from 1990–2005 to 2071–2080 in all four cities. This result suggests that the heat stress of a day at a given Tmax will increase in a warming climate due to the increase of RH.

Yuan, Jiacan↗