Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydraulic turbines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Simulation of Peach Bottom turbine trip transient with RETRAN-3D using BXFGEN

The Peach Bottom 2 Turbine Trip transient is used to evaluate the capabilities and accuracy of coupled 3-D neutronics/thermal hydraulics best estimate calculations for support of safety analysis. Selected results, obtained with RETRAN-3D, are compared to available measurements and benchmark results. The comparisons are analyzed and the application of RETRAN-3D for a best estimate analysis approach within the safety analysis methodology is discussed. Overall, both the thermal-hydraulic and neutronic results show a good comparison to the experimental data, and the model is considered to accurately predict test data. In particular, the initial acoustic response of the main steam line and the subsequent main pressurization stages are well-predicted. During the main pressurization stage, the timing and magnitude of the in-core local pressurization and associated void compression are properly predicted based upon the agreement between local power range monitors (LPRM) predictions upwards, but the shift is slightly underpredicted. This indicates the methodology is well-posed for simulating this class of transient response.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat transfer in rotating serpentine passages with trips skewed to the flow

Experiments were conducted to determine the effects of buoyancy and Coriolis forces on heat transfer in turbine blade internal coolant passages. The experiments were conducted with a large scale, multi-pass, heat transfer model with both radially inward and outward flow. Trip strips, skewed at 45 deg to the flow direction, were machined on the leading and trailing surfaces of the radial coolant passages. An analysis of the governing flow equations showed that four parameters influence the heat transfer in rotating passages: coolant-to-wall temperature, rotation number, Reynolds number, and radius-to-passage hydraulic diameter ratio. The first three of these four parameters were varied over ranges which are typical of advanced gas turbine engine operating conditions. Results were correlated and compared to previous results from similar stationary and rotating models with smooth walls and with trip strips normal to the flow direction. The heat transfer coefficients on surfaces, where the heat transfer decreased with rotation and buoyancy, decreased to as low as 40 percent of the value without rotation. However, the maximum values of the heat transfer coefficients with high rotation were only slightly above the highest levels previously obtained with the smooth wall models. It was concluded that (1) both Coriolis and buoyancy effects must be considered in turbine blade cooling designs with trip strips, (2) the effects of rotation are markedly different depending upon the flow direction, and (3) the heat transfer with skewed trip strips is less sensitive to buoyancy than the heat transfer in models with either smooth or normal trips. Therefore, skewed trip strips rather than normal trip strips are recommended and geometry-specific tests are required for accurate design information.

Johnson, B. V.↗

H2-O2 auxiliary power unit for Space Shuttle vehicles - A progress report.

Description of a program to establish technology readiness of hydrogen-oxygen (H2-O2) auxiliary power units for use on board the Space Shuttle orbiter vehicle. Fundamental objectives include experimentally establishing an acceptable propellant flow control method, verification of combustor stability, and adequate thermal management. An initial auxiliary power unit (APU) configuration with recycled hydrogen flow has been studied and revised toward greater simplicity and scaling ease. The selected APU is a recuperated open-cycle, turbine-driven unit. Series flow of cryogenic hydrogen removes internally-generated heat and heat from the hydraulic system. The revised configuration schematic and its calculated performance are reviewed. A weight comparison is made between the shuttle baseline hydrazine and H2-O2 APU systems, showing that hydrogen-oxygen APUs have the potential of increasing the payload of the Space Shuttle.

Joyce, J. P.↗

Measurements of Forward Flight Effects on the Advanced Ducted Propulsion Demonstrator Engine

The performance of the Pratt & Whitney Advanced Ducted Propulsion (ADP) UHB concept has been recently evaluated with studies of a 17 in. diameter fan simulator. Following the model scale tests, a 118 in. diameter demonstrator was tested at the NASA Ames 40- by 80-Foot Wind Tunnel. The 18 blade fan was driven by the low compressor shaft of a PW2037 core through a reduction gear system fabricated by Fiat with approximately 1:3.7 reduction ratio. ne variable pitch fan was hydraulically actuated with settings for take-off, cruise, feather, and reverse thrust. The low-pressure turbine was built by MTU to provide higher shaft power in comparison with the standard PW2037. The demonstrator was provided with 45 vanes located 2.6 fan chords downstream of the rotor, and 10 case struts approximately 1 fan chord downstream of the vanes. The inlet, mid-duct, and exhaust linings were acoustically treated. Acoustic surveys were taken in the for-ward thrust mode for fan speeds of 898, 1120, 1205, and 1302 R.P.M., and at tunnel speeds of 25, 50, 100, and 140 kts. The lowest speed was achieved with the wind tunnel fans at flat pitch, but with the engine pumping the test section Microphone signals were recorded for 30 seconds at 5 deg. increments. These measurements will be used to assess the effects of forward speed on UHB engines, to compare these effects with the corresponding characteristics of conventional bypass ratio engines, and to discuss the various aspects of testing large engines in the wind tunnel.

Horne, W. C.↗

Gambusia holbrooki Survive Shear Stress, Pressurization and Avoid Blade Strike in a Simulated Pumped Hydroelectric Scheme

Pumped hydroelectric energy storage (PHES) projects are being considered worldwide as a means of achieving political renewable energy targets in a way that stabilises baseload energy supply from often intermittent renewable energy sources. Unlike a conventional hydroelectric system that only pass water in a downstream direction, a feature of PHES is that it relies on the bi-directional flow of water. In some cases this flow can be across different waterbodies or catchments, posing a risk of inadvertently expanding the range of aquatic animals like fish. The risk of this happening depends on the likelihood of survival of individuals, which remains poorly understood for turbines that are pumping rather than generating. This study quantified the survival of a globally widespread and invasive poeciliid fish, Eastern gambusia (Gambusia holbrooki) when exposed hydraulic stresses characteristic of what would be experienced through a PHES during the pumping phase. A shear flume and hyperbaric chamber were used to expose fish to different strain rates and rapid and sustained pressurisation. A blade strike model was also used to predict survival of fish passing through a Francis dual turbine / pump. The ranges simulated were based on design and operational conditions provided for a PHES scheme being proposed in south-eastern Australia. All gambusia tested survived extremely high (up to 7600 kPa gauge pressure) pressurisation, high levels of shear stress (up to 1853 s -1 ), and the majority (> 93 %) were unlikely to be struck by a turbine blade. Given their tolerance to these extreme simulated stresses, we conclude that gambusia will likely survive passage through a PHES scheme. Therefore, where a new PHES poses the risk of inadvertently expanding the range of gambusia or similar poeciliid species, measures to minimise their spread or mitigate their ecosystem impacts should be considered.

25 ENERGY STORAGE↗

Triaxial Swirl Injector Element for Liquid-Fueled Engines

A triaxial injector is a single bi-propellant injection element located at the center of the injector body. The injector element consists of three nested, hydraulic swirl injectors. A small portion of the total fuel is injected through the central hydraulic injector, all of the oxidizer is injected through the middle concentric hydraulic swirl injector, and the balance of the fuel is injected through an outer concentric injection system. The configuration has been shown to provide good flame stabilization and the desired fuel-rich wall boundary condition. The injector design is well suited for preburner applications. Preburner injectors operate at extreme oxygen-to-fuel mass ratios, either very rich or very lean. The goal of a preburner is to create a uniform drive gas for the turbomachinery, while carefully controlling the temperature so as not to stress or damage turbine blades. The triaxial injector concept permits the lean propellant to be sandwiched between two layers of the rich propellant, while the hydraulic atomization characteristics of the swirl injectors promote interpropellant mixing and, ultimately, good combustion efficiency. This innovation is suited to a wide range of liquid oxidizer and liquid fuels, including hydrogen, methane, and kerosene. Prototype testing with the triaxial swirl injector demonstrated excellent injector and combustion chamber thermal compatibility and good combustion performance, both at levels far superior to a pintle injector. Initial testing with the prototype injector demonstrated over 96-percent combustion efficiency. The design showed excellent high -frequency combustion stability characteristics with oxygen and kerosene propellants. Unlike the more conventional pintle injector, there is not a large bluff body that must be cooled. The absence of a protruding center body enhances the thermal durability of the triaxial swirl injector. The hydraulic atomization characteristics of the innovation allow the design to be rapidly scaled from small in-space applications [500-5,000 lbf (2.2 22.2 kN)] to large thrust engine applications [80,000 lbf (356 kN) and beyond]. The triaxial injector is also less sensitive to eccentricities, manufacturing tolerances, and gap width of many traditional coaxial and pintle injector designs. The triaxial-injector injection orifice configuration provides for high injection stiffness. The low parts count and relatively large injector design features are amenable to low-cost production.

Muss, Jeff↗

Full-scale validation gaps and opportunities for low-head hydropower: a review and perspective

Hydropower is undergoing technological innovation as future development increasingly targets low-head sites (<10 m), primarily through retrofits, rehabilitation, and upgrades of existing infrastructure. This shift toward smaller systems creates a timely opportunity: unlike conventional large projects, many emerging low-head technologies may be small enough for direct full-scale validation. Full-scale testing is particularly important for environmental mitigation technologies, including fish passage, sediment continuity, and water-quality improvements, whose performance is difficult to assess reliably using reduced-scale models. Yet adoption remains constrained by the limited risk-bearing capacity of small hydropower owners, discouraging manufacturers from bringing unvalidated technologies to market. This review and perspective paper examines hydropower trends driving innovation, selected emerging technologies, conventional testing methods, and current U.S. testing capabilities as a case study. We then evaluate the gap between existing capabilities and the needs of low-head powertrains and environmental mitigation measures. Many technologies exceed existing facility flow capacities; in the U.S., the highest combined head–flow capability is limited to 5.66 m3/s, compared with median and 90th-percentile low-head turbine-unit flows of 14.3 and 60 m3/s. To mitigate this gap, we advocate repurposing large, retired, or underused hydraulic infrastructure as full-scale testing facilities to reduce first-adoption risk and support sustainable low-head hydropower deployment.

Tseng, Chien-Yung [Colorado State University, Fort↗

Localized Flow Modification to Increase Power Capture of a Small-Scale Floating Undershot Waterwheel

The goal of the work described in this thesis is to design a flow augmentation device to increase the power capture and efficiency of a small-scale floating Under-Shot Water Wheel (USWW) currently being developed by Florida Atlantic University research funded by the U.S Department of Energy. The flow concentrator subsystem is intended to maximize the kinetic energy extracted by the marine hydrokinetic (MHK) energy collection device through modification of the local flow field across the capture plane. The primary objective is to increase the velocity and/or rate of mass inflow through the turbine through inserting a streamlined body in the region of interest. By utilizing the resulting flow field to increase hydraulic forcing on the waterwheel blades, the torque and/or RPM of the USWW can be increased. Based on experimental testing in the FAU wave tank at 1:5 prototype scale (280 mm wheel diameter) the flow concentrator was shown to produce an increase in device power coefficient of 17-55% measured over a velocity range of 0.16-0.45 m/s.

Hess, Sullivan↗

Autonomous sensor suite for evaluating fish-turbine interactions and environmental impacts in marine renewable energy and hydropower

Marine renewable energy (MRE) harnesses ocean-based resources such as waves, tides, currents, and thermal or salinity gradients for sustainable power generation. It has the potential to complement existing renewable resources, support remote communities, and contribute to decarbonization efforts. However, understanding the hydrodynamic forces created by MRE devices and their impacts on marine life is critical for responsible deployment. Here, to address these concerns, advanced sensor devices, including the Marine Sensor Fish (MSF), Sensor Fish Mini (SF Mini), and Flexible Sensor Fish (FSF), were developed to measure interactions between aquatic organisms and MRE systems. This paper details the design, manufacturing, calibration, and field deployment of these sensor suites, highlighting their ability to capture key physical stressors such as shear forces, pressure changes, and collision impacts. The MSF successfully evaluated turbine interactions at a tidal turbine in the Salish Sea, capturing data on turbulence, collision impact, and pressure gradients. The SF Mini validated hydrodynamic conditions in scaled hydraulic models, supporting computational fluid dynamics simulations. The FSF, with its flexible silicone body, measured species-specific impacts in turbulent environments. This research demonstrates the potential of Sensor Fish technology to advance sustainable marine energy systems by reducing biological impacts and informing environmentally sustainable designs.

Ecological impacts↗

Liquid rocket engine nozzles

The nozzle is a major component of a rocket engine, having a significant influence on the overall engine performance and representing a large fraction of the engine structure. The design of the nozzle consists of solving simultaneously two different problems: the definition of the shape of the wall that forms the expansion surface, and the delineation of the nozzle structure and hydraulic system. This monography addresses both of these problems. The shape of the wall is considered from immediately upstream of the throat to the nozzle exit for both bell and annular (or plug) nozzles. Important aspects of the methods used to generate nozzle wall shapes are covered for maximum-performance shapes and for nozzle contours based on criteria other than performance. The discussion of structure and hydraulics covers problem areas of regeneratively cooled tube-wall nozzles and extensions; it treats also nozzle extensions cooled by turbine exhaust gas, ablation-cooled extensions, and radiation-cooled extensions. The techniques that best enable the designer to develop the nozzle structure with as little difficulty as possible and at the lowest cost consistent with minimum weight and specified performance are described.

Source record↗

Preliminary design of an auxiliary power unit for the space shuttle: Component and system configuration screening analysis

The auxiliary power unit (APU) for the space shuttle is required to provide hydraulic and electrical power on board the booster and orbiter vehicles. Five systems and their associated components, which utilize hot gas turbines to supply horsepower at gearbox output pads, were studied. Hydrogen-oxygen and storable propellants were considered for the hot gas supply. All APU's were required to be self-contained with respect to dissipating internally generated heat. These five systems were evaluated relative to a consistent criteria. The system supplied with high pressure gaseous hydrogen and oxygen was recommended as the best approach. It included a two-stage pressure-compounded partial-admission turbine, a propellant conditioning system with recuperation, a control system, and a gearbox. The gearbox output used was 240 hp. At the close of the study a 400 hp level was considered more appropriate for meeting the prime shuttle vehicle needs, and an in-depth analysis of the system at the 400 hp output level was recommended.

Binsley, R. L.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 2: Component and system configuration screening analysis

The auxiliary power unit (APU) for the space shuttle is required to provide hydraulic and electrical power on board the booster and orbiter vehicles. Five systems and their associated components, which utilize hot gas turbines to supply horsepower at gearbox output pads, were studied. Hydrogen-oxygen and storable propellants were considered for the hot gas supply. All APU's were required to be self contained with respect to dissipating internally generated heat. These five systems were evaluated relative to a consistent criteria. The system supplied with high pressure gaseous hydrogen and oxygen was recommended as the best approach. It included a two-stage pressure-compounded partial-admission turbine, a propellant conditioning system with recuperation, a control system, and a gearbox. The gearbox output used was 240 HP. At the close of the study a 400 HP level was considered more appropriate for meeting the prime shuttle vehicle needs, and an in-depth analysis of the system at the 400 HP output level was recommended.

Burriss, W. L.↗

Local heat/mass transfer and pressure drop in a two-pass rib-roughened channel for turbine airfoil cooling

The heat transfer characteristics of turbulent air flow in a multipass channel were studied via the naphthalene sublimation technique. The naphthalene-coated test section, consisting of two straight, square channels joined by a 180 deg turn, resembled the internal cooling passages of gas turbine airfoils. The top and bottom surfaces of the test channel were roughened by rib turbulators. The rib height-to-hydraulic diameter ratio (e/D) were 0.063 and 0.094, and the rib pitch-to-height ratio (P/e) were 10 and 20. The local heat/mass transfer coefficients on the roughened top wall and on the smooth divider and side walls of the test channel were determined for three Reynolds numbers of 15, 30, and 60, thousand, and for three angles of attack (alpha) of 90, 60, and 45 deg. Results showed that the local Sherwood numbers on the ribbed walls were 1.5 to 6.5 times those for a fully developed flow in a smooth square duct. The average ribbed-wall Sherwood numbers were 2.5 to 3.5 times higher than the fully developed values, depending on the rib angle of attack and the Reynolds number. The results also indicated that, before the turn, the heat/mass transfer coefficients in the cases of alpha = 60 and 45 deg were higher than those in the case of alpha=90 deg. However, after the turn, the heat/mass transfer coefficients in the oblique-rib cases were lower than those in the transverse rib case. Correlations for the average Sherwood number ratios for individual channel surfaces and for the overall Sherwood number ratios are reported. Correlations for the fully developed friction factors and for the loss coefficients are also provided.

Han, J. C.↗

Adaptive Stiffness Power Take-Off System for a Hydraulic Hose-Pump Point Absorber Wave Energy Converter

Two crucial challenges faced in the design of ocean wave energy converters (WECs) are maintaining high capacity factors and remaining robust in everchanging, harsh ocean environments. This study introduces a novel mechanism for achieving reactive WEC control with a soft hydraulic power take-off, thereby addressing both challenges. The device of interest involves a hydraulic pump, constructed from a fluidic flexible matrix composite (F2MC), which is cyclically stretched by driving waves and pressurizes working fluid through a turbine-generator. This class of fiber-reinforced stretch hoses is established for ocean use as robust moorings and shock absorbers. The dynamic properties of the F2MC pump depend on internal pressure, which can be controlled by a continuously variable transmission between the turbine and generator, allowing the system to be adapted for better performance over a wide range of wave conditions. This work presents a dynamic model for operation and adaptive behavior of this power take-off system, experimentally validates components of the model, and performs dynamic simulations of the system that show increases in power production and capacity factor compared to non-adaptive operation for a variety of driving wave conditions. This work develops the basis for future large-scale experimental testing and controller design of this system.

Wave energy conversion, fluidic flexible matrix co↗

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset consists of NPDs in the conterminous US with at least 100kW of theoretical potential based on earlier resource assessments. Historical daily streamflow (modeled or from USGS gauge records), hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs for HydroGenerate which determines design flow and turbine efficiencies and then calculates nominal capacity, daily generation, and capacity factor. These outputs are summarized on a monthly basis (i.e., generation (MWh) and capacity factor averaged for each month from January to December) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of 4.1 GW capacity is estimated across all 2,564 NPDs included in the dataset.

13 HYDRO ENERGY↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset contains estimates of technical potential capacity and generation at 2,616 NPDs in the conterminous US. This is based on a subset of dams that were found by earlier resource assessments to have at least 100kW of theoretical potential. Historical daily streamflow (modeled or from USGS gauge records) and hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs to the HydroGenerate model, which determines design flow, turbine efficiencies, and assumed friction losses and then calculates nominal capacity, daily generation, and capacity factor. These estimates represent the conditions over the historical period of 1980-2015, and are summarized on a monthly basis (i.e., averaged for each month of the year) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of nearly 4 GW capacity is estimated across all 2,616 NPDs included in the dataset.

Hansen, Carly [Oak Ridge National Laboratory (ORNL↗

Core Stage TVC Systems Engineering Challenges in Reusing Heritage Hardware

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of 8 mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. Two actuators are used to move each engine in two planes perpendicular to one another (i.e., pitch and yaw). The TVC system design leverages hardware from the Space Shuttle program as well as new hardware designed specifically for the Core Stage. The Space Shuttle heritage hardware directly reused on SLS includes the Orbiter TVC hydraulic servo-actuators (with two slight design modifications), the Orbiter hydraulic circulation pumps, the Orbiter gimbal block/bearing, and the Solid Rocket Booster hydraulic pumps. The Core Auxiliary Power Unit (CAPU) is derived from the Orbiter Auxiliary Power Unit (APU). The Orbiter and Solid Rocket Booster APU turbines are powered by hot gas produced by catalyzed hydrazine decomposition. On the SLS Core Stage, the CAPU turbine is spun using cold gas tapped-off from the RS-25 to CS liquid hydrogen autogenous pressurization line. While direct reuse or slight modification of existing hardware may seem to be a triple-win for a program in cost, schedule, and technical risk mitigation, those benefits can only be realized when its degree of application in a new system is carefully and thoughtfully managed. The heritage hardware reuse should be prescribed within the heritage design capability and reuse environments must lie within the envelope of heritage qualification testing. Despite the significant test and flight experience of the Shuttle heritage hardware components, successful integration with the newly designed CS TVC components and incorporation into the stage design proved to be a challenge which required re-qualification of the heritage hardware as well as thorough integrated testing to support flight certification. Examples of the challenges that were overcome include: re-qualifying heritage hardware to survive new shock and vibration environments, certifying performance of extensively modified heritage hardware, regenerating design insight due to lack of available heritage vendor data, showing compliance to modern structural design standards, translation of heritage requirements for analog avionics to modern digital avionics, and interfacing heritage mechanical hardware with newly designed avionics. This paper is the second installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. This paper will discuss several engineering challenges encountered during the development process for SLS CS TVC and how they were successfully overcome to reach flight readiness.

Thrust Vector Control↗