The use of zeolites to generate PET phantoms for the validation of quantification strategies in oncology

Purpose: In recent years, segmentation algorithms and activity quantification methods have been proposed for oncological {sup 18}F-fluorodeoxyglucose (FDG) PET. A full assessment of these algorithms, necessary for a clinical transfer, requires a validation on data sets provided with a reliable ground truth as to the imaged activity distribution, which must be as realistic as possible. The aim of this work is to propose a strategy to simulate lesions of uniform uptake and irregular shape in an anthropomorphic phantom, with the possibility to easily obtain a ground truth as to lesion activity and borders. Methods: Lesions were simulated with samples of clinoptilolite, a family of natural zeolites of irregular shape, able to absorb aqueous solutions of {sup 18}F-FDG, available in a wide size range, and nontoxic. Zeolites were soaked in solutions of {sup 18}F-FDG for increasing times up to 120 min and their absorptive properties were characterized as function of soaking duration, solution concentration, and zeolite dry weight. Saturated zeolites were wrapped in Parafilm, positioned inside an Alderson thorax-abdomen phantom and imaged with a PET-CT scanner. The ground truth for the activity distribution of each zeolite was obtained by segmenting high-resolution finely aligned CT images, on the basis of independently obtained volume measurements. The fine alignment between CT and PET was validated by comparing the CT-derived ground truth to a set of zeolites' PET threshold segmentations in terms of Dice index and volume error. Results: The soaking time necessary to achieve saturation increases with zeolite dry weight, with a maximum of about 90 min for the largest sample. At saturation, a linear dependence of the uptake normalized to the solution concentration on zeolite dry weight (R{sup 2}= 0.988), as well as a uniform distribution of the activity over the entire zeolite volume from PET imaging were demonstrated. These findings indicate that the {sup 18}F-FDG solution is able to saturate the zeolite pores and that the concentration does not influence the distribution uniformity of both solution and solute, at least at the trace concentrations used for zeolite activation. An additional proof of uniformity of zeolite saturation was obtained observing a correspondence between uptake and adsorbed volume of solution, corresponding to about 27.8% of zeolite volume. As to the ground truth for zeolites positioned inside the phantom, the segmentation of finely aligned CT images provided reliable borders, as demonstrated by a mean absolute volume error of 2.8% with respect to the PET threshold segmentation corresponding to the maximum Dice. Conclusions: The proposed methodology allowed obtaining an experimental phantom data set that can be used as a feasible tool to test and validate quantification and segmentation algorithms for PET in oncology. The phantom is currently under consideration for being included in a benchmark designed by AAPM TG211, which will be available to the community to evaluate PET automatic segmentation methods.

60 APPLIED LIFE SCIENCES↗

A convenient alignment approach for x-ray imaging experiments based on laser positioning devices

This study presents a two-laser alignment approach for facilitating the precise alignment of various imaging and measuring components with respect to the x-ray beam. The first laser constantly pointed to the output window of the source, in a direction parallel to the path along which the components are placed. The second laser beam, originating from the opposite direction, was calibrated to coincide with the first laser beam. Thus, a visible indicator of the direction of the incident x-ray beam was established, and the various components could then be aligned conveniently and accurately with its help.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to improve cancerous lesion detection sensitivity in a dedicated dual-head scintimammography system

An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.

60 APPLIED LIFE SCIENCES↗

Method to improve cancerous lesion detection sensitivity in a dedicated dual-head scintimammography system

An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.

60 APPLIED LIFE SCIENCES↗

A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was Less-Than-Or-Slanted-Equal-To 3 mm (95th percentiles within {+-}4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from -0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of Less-Than-Or-Slanted-Equal-To 5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance.

60 APPLIED LIFE SCIENCES↗

Assessment of Planning Target Volume Margins for Intensity-Modulated Radiotherapy of the Prostate Gland: Role of Daily Inter- and Intrafraction Motion

Purpose: To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. Methods and Materials: Fourteen patients who underwent definitive intensity-modulated radiotherapy for prostate cancer formed the basis of this study. Each patient was implanted with three electromagnetic transponders and underwent a course of 39 treatment fractions. Daily localization was based on three-point skin mark alignment followed by transponder detection and patient repositioning. Transponder positioning was verified by volumetric imaging with cone-beam computed tomography of the pelvis. Relative motion between the prostate gland and bony anatomy was quantified by offline analyses of daily cone-beam computed tomography. Intratreatment organ motion was monitored continuously by the Calypso (registered) System for quantification of intrafraction setup error. Results: As expected, setup error (that is, inter- plus intrafraction motion, unless otherwise stated) was largest with skin mark alignment, requiring margins of 7.5 mm, 11.4 mm, and 16.3 mm, in the lateral (LR), longitudinal (SI), and vertical (AP) directions, respectively. Margin requirements accounting for intrafraction motion were smallest for transponder detection localization techniques, requiring margins of 1.4 mm (LR), 2.6 mm (SI), and 2.3 mm (AP). Bony anatomy alignment required 2.1 mm (LR), 9.4 mm (SI), and 10.5 mm (AP), whereas image-guided marker alignment required 2.8 mm (LR), 3.7 mm (SI), and 3.2 mm (AP). No marker migration was observed in the cohort. Conclusion: Clinically feasible, rapid, and reliable tools such as the electromagnetic transponder detection system for pretreatment target localization and, subsequently, intratreatment target location monitoring allow clinicians to reduce irradiated volumes and facilitate safe dose escalation, where appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ON THE PROGENITOR SYSTEM OF THE TYPE Iax SUPERNOVA 2014dt IN M61

We present pre-explosion and post-explosion Hubble Space Telescope images of the Type Iax supernova (SN Iax) 2014dt in M61. After astrometrically aligning these images, we do not detect any stellar sources at the position of the SN in the pre-explosion images to relatively deep limits (3σ limits of M {sub F438W} > –5.0 mag and M {sub F814W} > –5.9 mag). These limits are similar to the luminosity of SN 2012Z's progenitor system (M {sub F435W} = –5.43 ± 0.15 and M {sub F814W} = –5.24 ± 0.16 mag), the only probable detected progenitor system in pre-explosion images of a SN Iax, and indeed, of any white-dwarf supernova. SN 2014dt is consistent with having a C/O white-dwarf primary/helium-star companion progenitor system, as was suggested for SN 2012Z, although perhaps with a slightly smaller or hotter donor. The data are also consistent with SN 2014dt having a low-mass red giant or main-sequence star companion. The data rule out main-sequence stars with M {sub init} ≳ 16 M {sub ☉} and most evolved stars with M {sub init} ≳ 8 M {sub ☉} as being the progenitor of SN 2014dt. Hot Wolf-Rayet stars are also allowed, but the lack of nearby bright sources makes this scenario unlikely. Because of its proximity (D = 12 Mpc), SN 2014dt is ideal for long-term monitoring, where images in ∼2 yr may detect the companion star or the luminous bound remnant of the progenitor white dwarf.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-366: Clinical Implementation of MR-Guided Vaginal Cylinder Brachytherapy

Purpose: To evaluate the accuracy of MR-based vaginal brachytherapy source localization using an in-house MR-visible marker versus the alignment of an applicator model to MR images. Methods: Three consecutive patients undergoing vaginal HDR brachytherapy with a plastic cylinder were scanned with both CT and MRI (including T1- and T2- weighted images). An MR-visible source localization marker, consisting of a sealed thin catheter filled with either water (for T2 contrast) or Gd-doped water (for T1 contrast), was assembled shortly before scanning. Clinically, the applicator channel was digitized on CT with an x-ray marker. To evaluate the efficacy of MR-based applicator reconstruction, each MR image volume was aligned locally to the CT images based on the region containing the cylinder. Applicator digitization was performed on the MR images using (1) the MR visible marker and (2) alignment of an applicator surface model from Varian's Brachytherapy Planning software to the MRI images. Resulting source positions were compared with the original CT digitization. Results: Although the source path was visualized by the MR marker, the applicator tip proved difficult to identify due to challenges in achieving a watertight seal. This resulted in observed displacements of the catheter tip, at times >1cm. Deviations between the central source positions identified via aligning the applicator surface model to MR and using the xray marker on CT ranged from 0.07 – 0.19 cm and 0.07 – 0.20 cm on T1- weighted and T2-weighted images, respectively. Conclusion: Based on the current study, aligning the applicator model to MRI provides a practical, current approach to perform MR-based brachytherapy planning. Further study is needed to produce catheters with reliably and reproducibly identifiable tips. Attempts are being made to improve catheter seals, as well as to increase the viscosity of the contrast material to decrease fluid mobility inside the catheter.

60 APPLIED LIFE SCIENCES↗

SU-F-T-160: Commissioning of a Single-Room Double-Scattering Proton Therapy System

Purpose: To report the detailed commissioning experience for a compact double-scattering Mevion S250 proton therapy system at a University Cancer Center site. Methods: The commissioning of the proton therapy system mainly consisted of ensuring integrity of mechanical and imaging system, beam data collection, and commissioning of a treatment planning system (TPS). First, mechanical alignment and imaging were tested including safety, interlocks, positional accuracy of couch and gantry, image quality, mechanical and imaging isocenter and so on. Second, extensive beam data (outputs, PDDs, and profiles) were collected and analyzed through effective sampling of range (R) and modulation width (M) from 24 beam options. Three different output (cGy/MU) prediction models were also commissioned as primary and secondary MU calculation tool. Third, the Varian Eclipse TPS was commissioned through five sets of data collections (in-water Bragg peak scans, in-air longitudinal fluence scans, in-air lateral profiles, in-air half-beam profiles, and an HU-to-stopping-power conversion curve) and accuracy of TPS calculation was tested using in-water scans and dose measurements with a 2D array detector with block and range compensator. Finally, an anthropomorphic phantom was scanned and heterogeneity effects were tested by inserting radiochromic films in the phantom and PET activation scans for range verification in conjunction with end-to-end test. Results: Beam characteristics agreed well with the vendor specifications; however, minor mismatches in R and M were found in some measurements during the beam data collection. These were reflected into the TPS commissioning such that the TPS could accurately predict the R and M within tolerance levels. The output models had a good agreement with measured outputs (<3% error). The end-to-end test using the film and PET showed reasonably the TPS predicted dose, R and M in heterogeneous medium. Conclusion: The proton therapy system was successfully commissioned and was released for clinical use.

60 APPLIED LIFE SCIENCES↗

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Hohlraum Target Alignment from X-ray Detector Images using Starburst Design Patterns

National Ignition Facility (NIF) is a high-energy laser facility comprised of 192 laser beams focused with enough power and precision on a hydrogen-filled spherical, cryogenic target to initiate a fusion reaction. The target container, or hohlraum, must be accurately aligned to an x-ray imaging system to allow careful monitoring of the frozen fuel layer in the target. To achieve alignment, x-ray images are acquired through starburst-shaped windows cut into opposite sides of the hohlraum. When the hohlraum is in alignment, the starburst pattern pairs match nearly exactly and allow a clear view of the ice layer formation on the edge of the target capsule. During the alignment process, x-ray image analysis is applied to determine the direction and magnitude of adjustment required. X-ray detector and source are moved in concert during the alignment process. The automated pointing alignment system described here is both accurate and efficient. In this paper, we describe the control and associated image processing that enables automation of the starburst pointing alignment.

42 ENGINEERING↗

Profile Images and Annotations for Vehicle Re-identification Algorithms (PRIMAVERA)

This dataset contains 636,246 profile images of vehicles representing 13,963 unique vehicles. The data was collected by a set of roadside sensors over the course of three years. Each time a vehicle passed by one of the sensors, a series of images was collected. The images were processed to detect and localize each vehicle, and a license plate reader collocated with the sensor was used to provide a unique ID for the vehicle. Actual license plate numbers have been obfuscated by replacing with an arbitrary numerical ID for each vehicle. After localizing the vehicle in each image, the original RGB image was rotated, scaled, and shifted to produce a new RGB image of size 234x234 pixels such that the outermost two wheels are located at predetermined pixel locations in the image. In this way, all vehicle images are aligned to one another. This registration process occasionally results in a portion of certain vehicles being cutoff at the edges of the image. The dataset has been partitioned into two sets called training and validation. The two partitions no common vehicles, i.e., a vehicle present in one partition is guaranteed not to be present in the other. In this way, an algorithm can be validated against a set of new vehicles that were not seen during the training process. The training set contains 543,926 images from 64,440 vehicle passes representing 11,918 unique vehicles, while the validation set contains 92,320 images from 10,991 vehicle passes representing 2,045 unique vehicles. Vehicle images are organized by directories corresponding to unique vehicles. The file naming scheme is as follows: veh_{vehID}_tr_{passID}_{frameID}_{elevation}_{timeofday}.jpg where {vehID} is the vehicle ID (unique across the entire dataset), {passID} is an identifier for each tracked vehicle pass (unique across the entire dataset), {frameID} is the index of the frame within the given vehicle pass starting at 0, {elevation} is a two-letter string indicating whether the sensor was elevated (el) or at ground-level (gl), and {timeofday} is a two-letter string indicating whether the image was captured during daytime (dt) or nighttime (nt).

image↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part I - Environment Mapping

When characterizing facilities, advanced autonomous systems are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. One main focus of the research is the visual mapping of the environment.This paper presents a framework for the mapping aspect that utilizes lidar and SLAM technologies coupled with a monocular camera to create a point cloud of the environment. Upon completion, the present research work aims to provide an autonomous mobile robot the capability to localize itself and aid the user with visualizing the radiation data. Challenges: C++ node needs to properly synchronize image and point cloud data. 3D lidar has resolution of ± 3 cm. Proper camera calibration needed. Transforms need to be precise for proper alignment of image and point-cloud. Results: Voxelated point clouds. Accurate colors from calibrated cameras including details smaller than lidar resolution. Developed Robotics Operating System (ROS) package for ease of transfer to other robot platforms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Daily Bone Alignment With Limited Repeat CT Correction Rivals Daily Ultrasound Alignment for Prostate Radiotherapy

Purpose: To compare the effectiveness of daily ultrasound (US)- and computed tomography (CT)-guided alignments with an off-line correction protocol using daily bone alignment plus a correction factor for systematic internal prostate displacement (CF{sub ID}). Methods and Materials: Ten prostate cancer patients underwent CT scans three times weekly using an integrated CT-linear accelerator system, followed by alignment using US for daily radiotherapy. Intensity-modulated radiotherapy plans were designed with our current clinical margins. The treatment plan was copied onto the repeat CT images and aligned using several methods: (1) bone alignment plus CF{sub ID} after three off-line CT scans (bone+3CT), (2) bone alignment plus CF{sub ID} after six off-line CT scans (bone+6CT), (3) US alignment, and (4) CT alignment. The accuracy of the repeated US and CT measurements to determine the CF{sub ID} was compared. The target dosimetric effect was quantified. Results: The CF{sub ID} for internal systematic prostate displacements was more accurately measured with limited repeat CT scans than with US (residual error, 0.0 {+-} 0.7 mm vs. 2.0 {+-} 3.2 mm). Bone+3CT, bone+6CT, and US provided equivalent prostate and seminal vesicle dose coverage, but bone+3CT and bone+6CT produced more precise daily alignments. Daily CT alignment provided the greatest target dose coverage. Conclusion: Daily bone alignment plus CF{sub ID} for internal systematic prostate displacement provided better daily alignment precision and equivalent dose coverage compared with daily US alignment. The CF{sub ID} should be based on at least three repeat CT scans, which could be collected before the start of treatment or during the first 3 treatment days. Daily bone alignment plus CF{sub ID} provides another option for accurate prostate cancer patient positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: System description and alignment accuracy

Purpose: A mobile radiography automatic grid alignment system (AGAS) has been developed by modifying a commercially available mobile unit. The objectives of this article are to describe the modifications and operation and to report on the accuracy with which the focal spot is aligned to the grid and the time required to achieve the alignment. Methods: The modifications include an optical target arm attached to the grid tunnel, a video camera attached to the collimator, a motion control system with six degrees of freedom to position the collimator and x-ray tube, and a computer to control the system. The video camera and computer determine the grid position, and then the motion control system drives the x-ray focal spot to the center of the grid focal axis. The accuracy of the alignment of the focal spot with the grid and the time required to achieve alignment were measured both in laboratory tests and in clinical use. Results: For a typical exam, the modified unit automatically aligns the focal spot with the grid in less than 10 s, with an accuracy of better than 4 mm. The results of the speed and accuracy tests in clinical use were similar to the results in laboratory tests. Comparison patient chest images are presented--one obtained with a standard mobile radiographic unit without a grid and the other obtained with the modified unit and a 15:1 grid. The 15:1 grid images demonstrate a marked improvement in image quality compared to the nongrid images with no increase in patient dose. Conclusions: The mobile radiography AGAS produces images of significantly improved quality compared to nongrid images with alignment times of less than 10 s and no increase in patient dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Fully Automated Method for CT-on-Rails-Guided Online Adaptive Planning for Prostate Cancer Intensity Modulated Radiation Therapy

Purpose: This study was designed to validate a fully automated adaptive planning (AAP) method which integrates automated recontouring and automated replanning to account for interfractional anatomical changes in prostate cancer patients receiving adaptive intensity modulated radiation therapy (IMRT) based on daily repeated computed tomography (CT)-on-rails images. Methods and Materials: Nine prostate cancer patients treated at our institution were randomly selected. For the AAP method, contours on each repeat CT image were automatically generated by mapping the contours from the simulation CT image using deformable image registration. An in-house automated planning tool incorporated into the Pinnacle treatment planning system was used to generate the original and the adapted IMRT plans. The cumulative dose–volume histograms (DVHs) of the target and critical structures were calculated based on the manual contours for all plans and compared with those of plans generated by the conventional method, that is, shifting the isocenters by aligning the images based on the center of the volume (COV) of prostate (prostate COV-aligned). Results: The target coverage from our AAP method for every patient was acceptable, while 1 of the 9 patients showed target underdosing from prostate COV-aligned plans. The normalized volume receiving at least 70 Gy (V{sub 70}), and the mean dose of the rectum and bladder were reduced by 8.9%, 6.4 Gy and 4.3%, 5.3 Gy, respectively, for the AAP method compared with the values obtained from prostate COV-aligned plans. Conclusions: The AAP method, which is fully automated, is effective for online replanning to compensate for target dose deficits and critical organ overdosing caused by interfractional anatomical changes in prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗