Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Detecting Anomalous Images in Astronomical Datasets

Abstract Environmental and instrumental conditions can cause anomalies in astronomical images, which can potentially bias all kinds of measurements if not excluded. Detection of the anomalous images is usually done by human eyes, which is slow and sometimes not accurate. This is an important issue in weak lensing studies, particularly in the era of large-scale galaxy surveys, in which image qualities are crucial for the success of galaxy shape measurements. In this work we present two automatic methods for detecting anomalous images in astronomical data sets. The anomalous features can be divided into two types: one is associated with the source images, and the other appears on the background. Our first method, called the entropy method, utilizes the randomness of the orientation distribution of the source shapes and the background gradients to quantify the likelihood of an exposure being anomalous. Our second method involves training a neural network (autoencoder) to detect anomalies. We evaluate the effectiveness of the entropy method on the Canada–France–Hawaii Telescope Lensing Survey (CFHTLenS) and Dark Energy Camera Legacy Survey (DECaLS DR3) data. In CFHTLenS, with 1171 exposures, the entropy method outperforms human inspection by detecting 12 of the 13 anomalous exposures found during human inspection and uncovering 10 new ones. In DECaLS DR3, with 17112 exposures, the entropy method detects a significant number of anomalous exposures while keeping a low false-positive rate. We find that although the neural network performs relatively well in detecting source anomalies, its current performance is not as good as the entropy method.

Astronomy & Astrophysics↗

Report on the AAPM grand challenge on deep generative modeling for learning medical image statistics

Abstract Background The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. Purpose The goal of this challenge was to promote the development of deep generative models for medical imaging and to emphasize the need for their domain‐relevant assessments via the analysis of relevant image statistics. Methods As part of this Grand Challenge, a common training dataset and an evaluation procedure was developed for benchmarking deep generative models for medical image synthesis. To create the training dataset, an established 3D virtual breast phantom was adapted. The resulting dataset comprised about 108 000 images of size 512 512. For the evaluation of submissions to the Challenge, an ensemble of 10 000 DGM‐generated images from each submission was employed. The evaluation procedure consisted of two stages. In the first stage, a preliminary check for memorization and image quality (via the Fréchet Inception Distance [FID]) was performed. Submissions that passed the first stage were then evaluated for the reproducibility of image statistics corresponding to several feature families including texture, morphology, image moments, fractal statistics, and skeleton statistics. A summary measure in this feature space was employed to rank the submissions. Additional analyses of submissions was performed to assess DGM performance specific to individual feature families, the four classes in the training data, and also to identify various artifacts. Results Fifty‐eight submissions from 12 unique users were received for this Challenge. Out of these 12 submissions, 9 submissions passed the first stage of evaluation and were eligible for ranking. The top‐ranked submission employed a conditional latent diffusion model, whereas the joint runners‐up employed a generative adversarial network, followed by another network for image superresolution. In general, we observed that the overall ranking of the top 9 submissions according to our evaluation method (i) did not match the FID‐based ranking, and (ii) differed with respect to individual feature families. Another important finding from our additional analyses was that different DGMs demonstrated similar kinds of artifacts. Conclusions This Grand Challenge highlighted the need for domain‐specific evaluation to further DGM design as well as deployment. It also demonstrated that the specification of a DGM may differ depending on its intended use.

Radiology, Nuclear Medicine & Medical Imaging↗

Far-field thermal imaging below diffraction limit

Non-uniform self-heating and temperature hotspots are major concerns compromising the performance and reliability of submicron electronic and optoelectronic devices. At deep submicron scales where effects such as contact-related artifacts and diffraction limits accurate measurements of temperature hotspots, non-contact thermal characterization can be extremely valuable. In this work, we use a Bayesian optimization framework with generalized Gaussian Markov random field (GGMRF) prior model to obtain accurate full-field temperature distribution of self-heated metal interconnects from their thermoreflectance thermal images (TRI) with spatial resolution 2.5 times below Rayleigh limit for 530nm illumination. Finite element simulations along with TRI experimental data were used to characterize the point spread function of the optical imaging system. In addition, unlike iterative reconstruction algorithms that use ad hoc regularization parameters in their prior models to obtain the best quality image, we used numerical experiments and finite element modeling to estimate the regularization parameter for solving a real experimental inverse problem.

42 ENGINEERING↗

Evaluating User Errors and Temporal Trends in Marine Fish Communities Using 360-Degree Underwater Photography

The use of environmental DNA (eDNA) sampling has been proposed as a complementary method to monitor fish species in marine environments, offering a non-invasive and potentially more efficient approach to marine species observations. eDNA monitoring could be especially useful in and around sites targeted for marine energy generation as these regions need regular monitoring that would be impractical with traditional techniques. Before we can fully rely upon eDNA, we must first verify its accuracy against other proven methods, such as the use of underwater photography. In this study, I deployed a 360-degree camera in the tidal channel of Sequim Bay once a month during several hours overlapping slack tide. I investigated how having multiple people identify and count fish on underwater images could affect the overall results. Using chi square tests in R, I compared my fish identifications and counts to those made by another intern on the same images recorded in August. I found significant differences in the number of species identified and the total individual counts between the two different datasets. I also tested the statistical differences in both Shannon diversity and Pielou evenness indices between the August, September, and November camera deployments using a Hutcheson t-test. Only one significant difference was found in the Shannon index comparisons, and none were found between the Pielou evenness comparisons. These findings show that if multiple identifiers are used to process underwater images, quality control checks must be made to reduce the potential for error. This also points toward the possibility to leverage more advanced image analysis processes, such as automated image analysis software. The findings from this study also show that the dynamics of marine fish communities can vary over a few months; however, further analysis is needed to determine the extent of the seasonal changes in Sequim Bay.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Transport of intensity equation: a tutorial

When it comes to “phase measurement” or “quantitative phase imaging”, many people will automatically connect them with “laser” and “interferometry”. Indeed, conventional quantitative phase imaging and phase measurement techniques generally rely on the superposition of two beams with a high degree of coherence: complex interferometric configurations, stringent requirements on the environmental stabilities, and associated laser speckle noise severely limit their applications in optical imaging and microscopy. On a different note, as one of the most well-known phase retrieval approaches, the transport of intensity equation (TIE) provides a new non-interferometric way to access quantitative phase information through intensity only measurement. Despite the insufficiency for interferometry, TIE is applicable under partially coherent illuminations (like the Köhler’s illumination in a conventional microscope), permitting optimum spatial resolution, higher signal-to-noise ratio, and better image quality. In this tutorial, we give an overview of the basic principle, research fields, and representative applications of TIE, focus particularly on optical imaging, metrology, and microscopy. The purpose of this tutorial is twofold. It should serve as a self-contained introduction to TIE for readers with little or no knowledge of TIE. On the other hand, it attempts to give an overview of recent developments in this field. These results highlight a new era in which strict coherence and interferometry are no longer prerequisites for quantitative phase imaging and diffraction tomography, paving the way toward new generation label-free three-dimensional microscopy, with applications in all branches of biomedicine.

42 ENGINEERING↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

Neural network for 3D inertial confinement fusion shell reconstruction from single radiographs

In inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired. To improve the imaging quality as a result of this limitation, convolutional neural networks (CNNs) have recently been shown to be capable of producing 3D models from visible light images or medical x-ray images rendered by volumetric computed tomography. Here, we propose a CNN to reconstruct 3D ICF spherical shells from single radiographs. We also examine the sensitivity of the 3D reconstruction to different illumination models using preprocessing techniques such as pseudo-flatfielding. To resolve the issue of the lack of 3D supervision, we show that training the CNN utilizing synthetic radiographs produced by known simulation methods allows for reconstruction of experimental data as long as the experimental data are similar to the synthetic data. We also show that the CNN allows for 3D reconstruction of shells that possess low mode asymmetries. Further comparisons of the 3D reconstructions with direct multiple LOS measurements are justified.

3D Reconstruction↗

Improving the Concrete Crack Detection Process via a Hybrid Visual Transformer Algorithm

Inspections of concrete bridges across the United States represent a significant commitment of resources, given their biannual mandate for many structures. With a notable number of aging bridges, there is an imperative need to enhance the efficiency of these inspections. This study harnessed the power of computer vision to streamline the inspection process. Our experiment examined the efficacy of a state-of-the-art Visual Transformer (ViT) model combined with distinct image enhancement detector algorithms. We benchmarked against a deep learning Convolutional Neural Network (CNN) model. These models were applied to over 20,000 high-quality images from the Concrete Images for Classification dataset. Traditional crack detection methods often fall short due to their heavy reliance on time and resources. This research pioneers bridge inspection by integrating ViT with diverse image enhancement detectors, significantly improving concrete crack detection accuracy. Notably, a custom-built CNN achieves over 99% accuracy with substantially lower training time than ViT, making it an efficient solution for enhancing safety and resource conservation in infrastructure management. These advancements enhance safety by enabling reliable detection and timely maintenance, but they also align with Industry 4.0 objectives, automating manual inspections, reducing costs, and advancing technological integration in public infrastructure management.

42 ENGINEERING↗

Expediting DECam Multimessenger Counterpart Searches with Convolutional Neural Networks

Searches for counterparts to multimessenger events with optical imagers use difference imaging to detect new transient sources. However, even with existing artifact-detection algorithms, this process simultaneously returns several classes of false positives: false detections from poor-quality image subtractions, false detections from low signal-to-noise images, and detections of preexisting variable sources. Currently, human visual inspection to remove the false positives is a central part of multimessenger follow-up observations, but when next generation gravitational wave and neutrino detectors come online and increase the rate of multimessenger events, the visual inspection process will be prohibitively expensive. We approach this problem with two convolutional neural networks operating on the difference imaging outputs. The first network focuses on removing false detections and demonstrates an accuracy of 92% on our data set. The second network focuses on sorting all real detections by the probability of being a transient source within a host galaxy and distinguishes between various classes of images that previously required additional human inspection. We find the number of images requiring human inspection will decrease by a factor of 1.5 using our approach alone and a factor of 3.6 using our approach in combination with existing algorithms, facilitating rapid multimessenger counterpart identification by the astronomical community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image fusion for neutron tomography of nuclear fuel

Image fusion, the process of combining different images together, can be useful to create a more complete picture. In this work, image fusion is applied to neutron tomography of nuclear fuel with the goal of enhancing the information obtained about the fuel. Different reconstruction methods, such as Feldkamp, Davis and Kress filtered back projection and Simultaneous Reconstruction Technique, were combined to enhance image quality. This methodology was shown to reduce noise and ring artifacts without sacrificing sharp edges, allowing for a more accurate representation of sample geometry. Technique enhancements and future applications for the neutron imaging community are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Active Optical Control with Machine Learning: A Proof of Concept for the Vera C. Rubin Observatory

Abstract The Active Optics System of the Vera C. Rubin Observatory (Rubin) uses information provided by four wave front sensors to determine deviations between the reconstructed wave front and the ideal wave front. The observed deviations are used to adjust the control parameters of the optical system to maintain image quality across the 3.°5 field of view. The baseline approach from the project is to obtain amplitudes of the Zernike polynomials describing the distorted wave front from out-of-focus images collected by the wave front sensors. These Zernike amplitudes are related via an “influence matrix” to the control parameters necessary to correct the wave front. In this paper, we use deep-learning methods to extract the control parameters directly from the images captured by the wave front sensors. Our neural net model uses anti-aliasing pooling to boost performance, and a domain-specific loss function to aid learning and generalization. The accuracy of the control parameters derived from our model exceeds Rubin requirements even in the presence of full-moon background levels and mis-centering of reference stars. Although the training process is time consuming, model evaluation requires only a few milliseconds. This low latency should allow for the correction of the optical configuration during the readout and slew interval between successive exposures.

Astronomy & Astrophysics↗

Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging

Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.

42 ENGINEERING↗

Hybrid achromatic microlenses with high numerical apertures and focusing efficiencies across the visible

Abstract Compact visible wavelength achromats are essential for miniaturized and lightweight optics. However, fabrication of such achromats has proved to be exceptionally challenging. Here, using subsurface 3D printing inside mesoporous hosts we densely integrate aligned refractive and diffractive elements, forming thin high performance hybrid achromatic imaging micro-optics. Focusing efficiencies of 51–70% are achieved for 15μm thick, 90μm diameter, 0.3 numerical aperture microlenses. Chromatic focal length errors of less than 3% allow these microlenses to form high-quality images under broadband illumination (400–700 nm). Numerical apertures upwards of 0.47 are also achieved at the cost of some focusing efficiency, demonstrating the flexibility of this approach. Furthermore, larger area images are reconstructed from an array of hybrid achromatic microlenses, laying the groundwork for achromatic light-field imagers and displays. The presented approach precisely combines optical components within 3D space to achieve thin lens systems with high focusing efficiencies, high numerical apertures, and low chromatic focusing errors, providing a pathway towards achromatic micro-optical systems.

47 OTHER INSTRUMENTATION↗

Imaging Sequences for Hyperpolarized Solids

Hyperpolarization is one of the approaches to enhance Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) signal by increasing the population difference between the nuclear spin states. Imaging hyperpolarized solids opens up extensive possibilities, yet is challenging to perform. The highly populated state is normally not replenishable to the initial polarization level by spin-lattice relaxation, which regular MRI sequences rely on. This makes it necessary to carefully “budget” the polarization to optimize the image quality. In this paper, we present a theoretical framework to address such challenge under the assumption of either variable flip angles or a constant flip angle. In addition, we analyze the gradient arrangement to perform fast imaging to overcome intrinsic short decoherence in solids. Hyperpolarized diamonds imaging is demonstrated as a prototypical platform to test the theory.

59 BASIC BIOLOGICAL SCIENCES↗

Initial Stage of Nanoscale Imaging in Positive Tone Extreme UV Photoresists: The Influence of the Polymer Sequence

Photolithographic patterning using extreme ultraviolet (EUV, 92.5 eV) light is a radiolytic process that initially forms electrons, radical cations, anions, and neutral radicals in the polymeric photoresist matrix. These species may participate in the chemical reactions that define the ultimate resolution of the printed image, and their concentrations and nanometer-scale stochastic variations in their formation influence printed image quality. Proposals have been made that polymer chain uniformity may be advantageous in reducing stochastics due to spatial inhomogeneities, and this aspect of radiolysis is examined in this work. We have simulated the initial subpicosecond stages of the imaging process for a series of photoresist films that are identical in composition but vary in their polymer chain structures. We use detailed, physically accurate stochastic reaction-diffusion calculations to evaluate the influence of defined sequence and random copolymer structures on radiolytic spur formation, i.e., a cluster of species formed by electron-polymer interactions that defines the initial spatial characteristic of the imaging process. Predictions of electron thermalization in the present work are shown to be consistent with the literature, indicating that our overall computational approach for ultrafast nanoscale processes is sound. The computational results show that the polymer sequence has no significant effect on the spur composition. This suggests that any potential imaging improvements to be gained by sequence control must originate from postimaging lithographic process steps.

Absorption↗