Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Solution processed high aspect ratio ultra-long vertically well-aligned ZnO nano scintillators for potential X-ray imaging applications

We report the photon (PL), electron (CL) and X-ray (XEL) induced luminescence characteristics of high aspect ratio ultra-long (~ 50 µm) ZnO nanorods (NRs) and discuss the potential for fast X-ray detection based on the consistent and efficient visible emission (~ 580 nm) from ZnO NRs. Nanostructured ZnO scintillators were rearranged to form a vertically well-aligned NR design in order to help light absorption and coupling resulting in luminescent and fast scintillation properties. The design of the nanorod array combines the key advantages of a low-cost growth technique together with environmentally friendly and widely available materials. A low temperature hydrothermal method was adopted to grow ZnO NRs in one cycle growth and their structural, optical and X-ray scintillation properties were investigated. The relatively short (~ 10 µm) ZnO NRs emitting in the near-band-edge region were found to be almost insensitive to X-rays. On the other hand, the higher XEL response of long ZnO NRs, which is a key parameter for evaluation of materials to be used as scintillators for high quality X-ray detection and imaging, along with a decay time response in the order of ns confirmed promising scintillation properties for fast and high-resolution X-ray detector applications.

47 OTHER INSTRUMENTATION↗

Interface structures of inclined ZnO thin film on (0 1 1)-MgO substrate with bulk-like optical properties

Combining different phase structure materials with unique properties to design novel devices plays a significant role in the development of modern electronics. Here, we explore the characteristics of this type of complex interface and epitaxy structures based on the coupling between hexagonal ZnO film and cubic MgO substrate. The ZnO film was prepared by the molecular beam epitaxy technique on the MgO (0 1 1) substrate. The analysis results from the in situ reflection high energy electron diffraction patterns, X-ray diffraction (XRD)-pole figures and high resolution transmission electron microscopy images demonstrate that the film exhibits two-fold symmetry domains with a growth direction deviated from c-axis at about 31º along the [0 1 0] MgO or [0 $\bar{1}$ 0] MgO azimuth. Despite the intertwined diffusion from Zn and Mg atoms in the interface, which is the possible origin of a blue shift of about 0.083 eV in the Photoluminescence (PL) spectrum, the inclined film shows a full width at half maximum value that is close to the reported value from the high quality film. Finally, this work hopefully provides useful insights to the design and exploration of the novel optoelectronic devices that involve the integration of materials with different structure and different properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tunable Few-Layer van der Waals Crystals and Heterostructures as Emerging Energy and Quantum Materials (Final Technical Report)

2D and layered (van der Waals) semiconductors offer extraordinary opportunities for manipulating optically excited charge carriers, many-body excitations, and non-charge based quantum numbers. To date, research has focused on a limited group of materials, mostly transition metal dichalcogenides in the monolayer limit. Other van der Waals semiconductors, and especially few-layer to multilayer crystals and their heterostructures, carry large potential for the discovery of phenomena of interest for future energy and information technologies. But they remain largely unexplored, often due to a lack of access to high-quality materials and approaches for measuring their properties at the relevant scales. The goal of this project was to develop an EPSCoR-State/National Laboratory Partnership that addresses the challenges of preparing high-quality van der Waals semiconductors and of probing their structure, composition, and especially their optoelectronic and photonic properties, near the atomic scale using electron microscopy techniques. A central component of the project was the development of advanced methods for electron microscopy and electron-excited spectroscopy, taking advantage of unique samples as well as leading capabilities and expertise at the partner institutions. Efforts to advance leading-edge techniques was supported by ancillary developments, such as precision sample preparation for electron microscopy/spectroscopy, coordinated chemical imaging, and analytical electron microscopy. Experiments in materials synthesis and technique development were closely linked to theory and computation. The results obtained under this project yielded multifaceted benefits to the involved partners and their institutions, DOE-BES, the wider scientific community, and society at large, particularly in the State of Nebraska through dividends from knowledge and human capital generated under the project.

36 MATERIALS SCIENCE↗

SU-E-J-49: Design and Fabrication of Custom 3D Printed Phantoms for Radiation Therapy Research and Quality Assurance

Purpose The rapid proliferation of affordable 3D printing techniques has enabled the custom fabrication of items ranging from paper weights to medical implants. This study investigates the feasibility of utilizing the technology for developing novel phantoms for use in radiation therapy quality assurance (QA) procedures. Methods A phantom for measuring the geometric parameters of linear accelerator (LINAC) on-board imaging (OBI) systems was designed using SolidWorks. The design was transferred to a 3D printer and fabricated using a fused deposition modeling (FDM) technique. Fiducials were embedded in the phantom by placing 1.6 mm diameter steel balls in predefined holes and securing them with silicone. Several MV and kV images of the phantom were collected and the visibility and geometric accuracy were evaluated. A second phantom, for use in the experimental evaluation of a high dose rate (HDR) brachytherapy dosimeter, was designed to secure several applicator needles in water. The applicator was fabricated in the same 3D printer and used for experiments. Results The general accuracy of printed parts was determined to be 0.1 mm. The cost of materials for the imaging and QA phantoms were $22 and $5 respectively. Both the plastic structure and fiducial markers of the imaging phantom were visible in MV and kV images. Fiducial marker locations were determined to be within 1mm of desired locations, with the discrepancy being attributed to the fiducial attachment process. The HDR phantom secured the applicators within 0.5 mm of the desired locations. Conclusion 3D printing offers an inexpensive method for fabricating custom phantoms for use in radiation therapy quality assurance. While the geometric accuracy of such parts is limited compared to more expensive methods, the phantoms are still highly functional and provide a unique opportunity for rapid fabrication of custom phantoms for use in radiation therapy QA and research.

07 ISOTOPE AND RADIATION SOURCES↗

Anisotropic modeling and joint-MAP stitching for improved ultrasound model-based iterative reconstruction of large and thick specimens

One-sided non-destructive evaluation (NDE) is widely used to inspect materials, such as concrete structures in nuclear power plants (NPP). A widely used method for one-sided NDE is the synthetic aperture focusing technique (SAFT). The SAFT algorithm produces reasonable results when inspecting simple structures. However, for complex structures, such as heavily reinforced thick concrete structures, SAFT results in artifacts and hence there is a need for a more sophisticated inversion technique. Model-based iterative reconstruction (MBIR) algorithms, which are typically equivalent to regularized inversion techniques, offer a powerful framework to incorporate complex models for the physics, detector miscalibrations and the materials being imaged to obtain high quality reconstructions. Previously, we have proposed an ultrasonic MBIR method that signifcantly improves reconstruction quality compared to SAFT. However, the method made some simplifying assumptions on the propagation model and did not disucss ways to handle data that is obtained by raster scanning a system over a surface to inspect large regions. In this paper, we propose a novel MBIR algorithm that incorporates an anisotropic forward model and allows for the joint processing of data obtained from a system that raster scans a large surface. We demonstrate that the new MBIR method can produce dramatic improvements in reconstruction quality compared to SAFT and suppresses articfacts compared to the perviously presented MBIR approach.

Almansouri, Hani↗

High resolution hard x-ray microscope on a second generation synchrotron source

A full-field, transmission x-ray microscope (TXM) operating in the energy range of 7-11 keV has been installed at the U7A beamline at the National Synchrotron Radiation Laboratory, a second generation synchrotron source operating at 0.8 GeV. Although the photon flux at sample position in the operating energy range is significantly low due to its relatively large emittance, the TXM can get high quality x-ray images with a spatial resolution down to 50 nm with acceptable exposure time. This TXM operates in either absorption or Zernike phase contrast mode with similar resolution. This TXM is a powerful analytical tool for a wide range of scientific areas, especially studies on nanoscale phenomena and structural imaging in biology, materials science, and environmental science. We present here the property of the x-ray source, beamline design, and the operation and key optical components of the x-ray TXM. Plans to improve the throughput of the TXM will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spinoff 2010

Topics covered include: Burnishing Techniques Strengthen Hip Implants; Signal Processing Methods Monitor Cranial Pressure; Ultraviolet-Blocking Lenses Protect, Enhance Vision; Hyperspectral Systems Increase Imaging Capabilities; Programs Model the Future of Air Traffic Management; Tail Rotor Airfoils Stabilize Helicopters, Reduce Noise; Personal Aircraft Point to the Future of Transportation; Ducted Fan Designs Lead to Potential New Vehicles; Winglets Save Billions of Dollars in Fuel Costs; Sensor Systems Collect Critical Aerodynamics Data; Coatings Extend Life of Engines and Infrastructure; Radiometers Optimize Local Weather Prediction; Energy-Efficient Systems Eliminate Icing Danger for UAVs; Rocket-Powered Parachutes Rescue Entire Planes; Technologies Advance UAVs for Science, Military; Inflatable Antennas Support Emergency Communication; Smart Sensors Assess Structural Health; Hand-Held Devices Detect Explosives and Chemical Agents; Terahertz Tools Advance Imaging for Security, Industry; LED Systems Target Plant Growth; Aerogels Insulate Against Extreme Temperatures; Image Sensors Enhance Camera Technologies; Lightweight Material Patches Allow for Quick Repairs; Nanomaterials Transform Hairstyling Tools; Do-It-Yourself Additives Recharge Auto Air Conditioning; Systems Analyze Water Quality in Real Time; Compact Radiometers Expand Climate Knowledge; Energy Servers Deliver Clean, Affordable Power; Solutions Remediate Contaminated Groundwater; Bacteria Provide Cleanup of Oil Spills, Wastewater; Reflective Coatings Protect People and Animals; Innovative Techniques Simplify Vibration Analysis; Modeling Tools Predict Flow in Fluid Dynamics; Verification Tools Secure Online Shopping, Banking; Toolsets Maintain Health of Complex Systems; Framework Resources Multiply Computing Power; Tools Automate Spacecraft Testing, Operation; GPS Software Packages Deliver Positioning Solutions; Solid-State Recorders Enhance Scientific Data Collection; Computer Models Simulate Fine Particle Dispersion; Composite Sandwich Technologies Lighten Components; Cameras Reveal Elements in the Short Wave Infrared; Deformable Mirrors Correct Optical Distortions; Stitching Techniques Advance Optics Manufacturing; Compact, Robust Chips Integrate Optical Functions; Fuel Cell Stations Automate Processes, Catalyst Testing; Onboard Systems Record Unique Videos of Space Missions; Space Research Results Purify Semiconductor Materials; and Toolkits Control Motion of Complex Robotics.

Source record↗

Characterization of twin boundaries in an Fe–17.5Mn–0.56C twinning induced plasticity steel

A twinning-induced plasticity steel of composition Fe–17.5 wt.% Mn–0.56 wt.% C–1.39 wt.% Al–0.24 wt.% Si was analyzed for the purpose of characterizing the relationship between tensile strain and deformation twinning. Tensile samples achieved a maximum of 0.46 true strain at failure, and a maximum ultimate tensile strength of 1599 MPa. Electron backscatter diffraction (EBSD) analysis showed that the grain orientation rotated heavily to < 111 > parallel to the tensile axis above 0.3 true strain. Sigma 3 misorientations, as identified by EBSD orientation measurements, and using the image quality maps were used to quantify the number of twins present in the scanned areas of the samples. The image quality method yielded a distinct positive correlation between the twin area density and deformation, but the orientation measurements were unreliable in quantifying twin density in these structures. Quantitative analysis of the twin fraction is limited from orientation information because of the poor spatial resolution of EBSD in relation to the twin thickness. The EBSD orientation maps created for a thin foil sample showed some improvement in the resolution of the twins, but not enough to be significant. Measurements of the twins in the transmission electron microscopy micrographs yielded an average thickness of 23 nm, which is near the resolution capabilities of EBSD on this material for the instrumentation used. Electron channeling contrast imaging performed on one bulk tensile specimen of 0.34 true strain, using a method of controlled diffraction, yielded several images of twinning, dislocation structures and strain fields. A twin thickness of 66 nm was measured by the same method used for the transmission electron microscopy measurement. It is apparent that the results obtain by electron channeling contrast imaging were better than those by EBSD but did not capture all information on the twin boundaries such as was observed by transmission electron microscopy. - Highlights: • Performed tensile tests to assess mechanical performance of TWIP alloy • Analyzed tensile specimens using EBSD, TEM, and ECCI • EBSD showed that most twinning occurred at or near the < 111 >//TA orientation. • EBSD, TEM and ECCI were used to measure average twin density. • Compared spatial resolution of EBSD, ECCI and TEM for the instrumentation used.

36 MATERIALS SCIENCE↗

NDE of ceramics and ceramic composites

Although nondestructive evaluation (NDE) techniques for ceramics are fairly well developed, they are difficult to apply in many cases for high probability detection of the minute flaws that can cause failure in monolithic ceramics. Conventional NDE techniques are available for monolithic and fiber reinforced ceramic matrix composites, but more exact quantitative techniques needed are still being investigated and developed. Needs range from flaw detection to below 100 micron levels in monolithic ceramics to global imaging of fiber architecture and matrix densification anomalies in ceramic composites. NDE techniques that will ultimately be applicable to production and quality control of ceramic structures are still emerging from the lab. Needs are different depending on the processing stage, fabrication method, and nature of the finished product. NDE techniques are being developed in concert with materials processing research where they can provide feedback information to processing development and quality improvement. NDE techniques also serve as research tools for materials characterization and for understanding failure processes, e.g., during thermomechanical testing.

Vary, Alex↗

NDE of ceramics and ceramic composites

Although nondestructive evaluation (NDE) techniques for ceramics are fairly well developed, they are difficult to apply in many cases for high probability detection of the minute flaws that can cause failure in monolithic ceramics. Conventional NDE techniques are available for monolithic and fiber reinforced ceramic matrix composites, but more exact quantitative techniques needed are still being investigated and developed. Needs range from flaw detection to below 100 micron levels in monolithic ceramics to global imaging of fiber architecture and matrix densification anomalies in ceramic composites. NDE techniques that will ultimately be applicable to production and quality control of ceramic structures are still emerging from the lab. Needs are different depending on the processing stage, fabrication method, and nature of the finished product. NDE techniques are being developed in concert with materials processing research where they can provide feedback information to processing development and quality improvement. NDE techniques also serve as research tools for materials characterization and for understanding failure processes, e.g., during thermomechanical testing.

Vary, Alex A.↗

Audacity of huge: overcoming challenges of data scarcity and data quality for machine learning in computational materials discovery

Machine learning (ML)-accelerated discovery requires large amounts of high-fidelity data to reveal predictive structure–property relationships. For many properties of interest in materials discovery, the challenging nature and high cost of data generation has resulted in a data landscape that is both scarcely populated and of dubious quality. Data-driven techniques starting to overcome these limitations include the use of consensus across functionals in density functional theory, the development of new functionals or accelerated electronic structure theories, and the detection of where computationally demanding methods are most necessary. When properties cannot be reliably simulated, large experimental data sets can be used to train ML models. In the absence of manual curation, increasingly sophisticated natural language processing and automated image analysis are making it possible to learn structure–property relationships from the literature. Finally, models trained on these data sets will improve as they incorporate community feedback.

36 MATERIALS SCIENCE↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Multilayer Lateral Heterostructures of Van Der Waals Crystals with Sharp, Carrier–Transparent Interfaces

Abstract Research on engineered materials that integrate different 2D crystals has largely focused on two prototypical heterostructures: Vertical van der Waals stacks and lateral heterostructures of covalently stitched monolayers. Extending lateral integration to few layer or even multilayer van der Waals crystals could enable architectures that combine the superior light absorption and photonic properties of thicker crystals with close proximity to interfaces and efficient carrier separation within the layers, potentially benefiting applications such as photovoltaics. Here, the realization of multilayer heterstructures of the van der Waals semiconductors SnS and GeS with lateral interfaces spanning up to several hundred individual layers is demonstrated. Structural and chemical imaging identifies {110} interfaces that are perpendicular to the (001) layer plane and are laterally localized and sharp on a 10 nm scale across the entire thickness. Cathodoluminescence spectroscopy provides evidence for a facile transfer of electron‐hole pairs across the lateral interfaces, indicating covalent stitching with high electronic quality and a low density of recombination centers.

36 MATERIALS SCIENCE↗

Intrinsic structural defects in monolayer molybdenum disulfide

Monolayer molybdenum disulfide (MoS2) is a two-dimensional direct band gap semiconductor with distinctive mechanical, electronic, optical and chemical properties that can be utilized for novel nanoelectronics and optoelectronics devices. The performance of these electronic devices strongly depends on the quality and defect morphology of the MoS2 layers. Yet, little is known about the atomic structure of defects present in monolayer MoS2 and their influences on the material properties. Here we provide a systematic study of various intrinsic structural defects, including point defects, grain boundaries, and edges, in chemical vapor phase grown monolayer MoS2 via direct atomic resolution imaging, and explore their energy landscape and electronic properties using first-principles calculations. We discover that one-dimensional metallic wires can be created via two different types of 60 grain boundaries consisting of distinct 4-fold ring chains. A new type of edge reconstruction, representing a transition state during growth, was also identified, providing insights into the material growth mechanism. The atomic scale study of structural defects presented here brings new opportunities to tailor the properties of MoS2 via controlled synthesis and defect engineering.

Zhou, Wu↗

Synchrotron Radiation for Biomedical Imaging

A synchrotron radiation (SR) X-ray source is an extraordinary tool for many applications because of the high intensity, the energy spectrum properties, the peculiar laminar beam geometry and the high degree of coherence. In the past years several experimental studies have proven the suitability of SR in the field of biomedical X-ray imaging and in diagnostic radiography. SR based X-ray imaging techniques to be mentioned are transvenous coronary angiography, bronchography, computed tomography and mammography that have been successfully implemented at different SR laboratories all around the world. Moreover, the high degree of the coherence of the synchrotron source allows the implementation of novel phase-sensitive X-ray imaging modalities. In contrast to conventional X-ray radiography, based on different X-ray absorption properties of details within an object, these phase-based techniques are capable of visualizing structures that have different scattering and refraction properties respect to the surrounding material. Their importance in medical imaging lies in the fact that the diagnosis of several diseases requires the detection of tiny structures, that consist of light elements in a similar background, and that produce very low X-ray absorption, but considerable phase shift in the wave front propagation. Thus, phase-sensitive techniques may improve dramatically the image quality and subsequently the accuracy in diagnosis offering highly enhanced contrast with dose comparable or even lower than required by conventional radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

Various Types of Defects Detection in Flat and Curved Laminated Composite Plates using Nonintrusive Lamb Wave System

Composite materials are widely used in aerospace industries due to their light weight, strength, and various other desired properties. However, they are susceptible to various defects occurring during the manufacturing process or in service. Typical defects include porosity, wrinkles, and delamination. Nondestructive means of detection of the defects at any stage are of great importance to ensure quality and safety of composite structures. A nonintrusive removeable Lamb wave system and accompanied methodology that is not material-dependent is presented in this paper to detect various types of typical defects in laminated composite plates, flat or curved. Through multidimensional data acquisition and processing, abnormality in waves caused by defects is captured and presented in inspection images. The methodologies are demonstrated in 2 cases: flat plate with wrinkles, and curved plate with delamination. Overall the results show that Lamb waves using the piezoelectric transducer and laser vibrometer system can be used for various types of defects inspection in flat or curved composite plates.

composite structures↗

Femtosecond mega-electron-volt electron microdiffraction

To understand and control the basic functions of physical, chemical and biological processes from micron to nano-meter scale, an instrument capable of visualizing transient structural changes of inhomogeneous materials with atomic spatial and temporal resolutions, is required. One such technique is femtosecond electron microdiffraction, in which a short electron pulse with femtosecond-scale duration is focused into a micron-scale spot and used to obtain diffraction images to resolve ultrafast structural dynamics over a localized crystalline domain. In this letter, we report the experimental demonstration of time-resolved mega-electron-volt electron microdiffraction which achieves a 5 μm root-mean-square (rms) beam size on the sample and a 110 fs rms temporal resolution. Using pulses of 10k electrons at 4.2 MeV energy with a normalized emittance 3 nm-rad, we obtained high quality diffraction from a single 10 μm paraffin ( C 44 H 90 ) crystal. The phonon softening mode in optical-pumped polycrystalline Bi was also time-resolved, demonstrating the temporal resolution limits of the instrument. In conclusion, this new characterization capability will open many research opportunities in material and biological sciences.

36 MATERIALS SCIENCE↗