Search NASA⌕ Search

SEARCH · Search NASA

Results for “image stitching”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

3D nanolithography with metalens arrays and spatially adaptive illumination

The growing demand for advanced materials, miniaturized devices and integrated microsystems calls for the reliable fabrication of complex, multiscale, three-dimensional (3D) architectures, a need increasingly addressed through light-based and laser-based processes. However, owing to the field-of-view (FOV) limitations of conventional imaging optics, existing 3D laser nanofabrication techniques face fundamental challenges in throughput, proximity error and stitching defects on the path to scaling. Here, in this study, we present a scalable 3D nanofabrication platform that uses a metalens-generated focal spot array to parallelize two-photon lithography (TPL) beyond centimetre-scale write field areas. Metalenses are ideally suited for producing submicron-scale focal spots for high-throughput nanolithography, as they uniquely feature large numerical apertures (NAs), immersion media compatibility and large-scale manufacturability. We experimentally demonstrate a printing system that uses a 12-cm 2 metalens array to produce more than 120,000 cooperative focal spots, corresponding to a throughput exceeding 10 8 voxels s −1 . By programmatically patterning the focal spot array using a spatial light modulator (SLM), an adaptive parallel printing strategy is developed for precise greyscale linewidth modulation and choreographed printing of semiperiodic and fully aperiodic 3D geometries. We demonstrate parallel printing of replicated microstructures (>50 M microparticles per day), centimetre-scale 3D architectures with feature sizes down to 113 nm, and photonic and mechanical metamaterials. This work demonstrates the potential of 3D nanolithography towards wafer-scale production, showing how TPL could be used at scale for applications in microelectronics, biomedicine, quantum technology and high-energy laser targets.

Materials science↗

Physical interpretation and development of ultrasonic nondestructive evaluation techniques applied to the quantitative characterization of textile composite materials

In this Progress Report, we describe our current research activities concerning the development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the characterization of stitched composite materials and bonded aluminum plate specimens. One purpose of this investigation is to identify and characterize specific features of polar backscatter interrogation which enhance the ability of ultrasound to detect flaws in a stitched composite laminate. Another focus is to explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize bonded aluminum lap joints. As an approach to implementing quantitative ultrasonic inspection methods to both of these materials, we focus on the physics that underlies the detection of flaws in such materials.

Miller, James G.↗

Four-Dimensional Magnetic Resonance Imaging With 3-Dimensional Radial Sampling and Self-Gating–Based K-Space Sorting: Early Clinical Experience on Pancreatic Cancer Patients

Purpose: To apply a novel self-gating k-space sorted 4-dimensional MRI (SG-KS-4D-MRI) method to overcome limitations due to anisotropic resolution and rebinning artifacts and to monitor pancreatic tumor motion. Methods and Materials: Ten patients were imaged using 4D-CT, cine 2-dimensional MRI (2D-MRI), and the SG-KS-4D-MRI, which is a spoiled gradient recalled echo sequence with 3-dimensional radial-sampling k-space projections and 1-dimensional projection-based self-gating. Tumor volumes were defined on all phases in both 4D-MRI and 4D-CT and then compared. Results: An isotropic resolution of 1.56 mm was achieved in the SG-KS-4D-MRI images, which showed superior soft-tissue contrast to 4D-CT and appeared to be free of stitching artifacts. The tumor motion trajectory cross-correlations (mean ± SD) between SG-KS-4D-MRI and cine 2D-MRI in superior–inferior, anterior–posterior, and medial–lateral directions were 0.93 ± 0.03, 0.83 ± 0.10, and 0.74 ± 0.18, respectively. The tumor motion trajectories cross-correlations between SG-KS-4D-MRI and 4D-CT in superior–inferior, anterior–posterior, and medial–lateral directions were 0.91 ± 0.06, 0.72 ± 0.16, and 0.44 ± 0.24, respectively. The average standard deviation of gross tumor volume calculated from the 10 breathing phases was 0.81 cm{sup 3} and 1.02 cm{sup 3} for SG-KS-4D-MRI and 4D-CT, respectively (P=.012). Conclusions: A novel SG-KS-4D-MRI acquisition method capable of reconstructing rebinning artifact–free, high-resolution 4D-MRI images was used to quantify pancreas tumor motion. The resultant pancreatic tumor motion trajectories agreed well with 2D-cine-MRI and 4D-CT. The pancreatic tumor volumes shown in the different phases for the SG-KS-4D-MRI were statistically significantly more consistent than those in the 4D-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large-Format, Fully-Depleted, Back-Illuminated CMOS Imaging Technology

A Voxtel-led team has developed a new class of large-area, high-performance, backside-illuminated CMOS imaging sensor for low-light-level surveillance applications, specifically designed for both low-noise and high near-infrared (NIR) response. The imager integrates two technologies: 1) large-area backside-illuminated (BSI) imaging; and 2) high-density 3D via-less electrical interconnection and wafer bonding. In this program, Voxtel, in collaboration with Jazz Semiconductor, Sharp Labs and Ziptronix Inc., developed and fabricated a wafer-scale imaging platform. We integrated the design rules necessary for large-area photocomposition using a sub-field stitched reticle at Jazz, and wafer-scale 3D stacked electrical connect using the Ziptronix process. The Jazz CA25QFES process was shown to be ideal for use in the Ziptronix process because of its compatibility with the last via back end of line (BEOL) process used to create tungsten vias up to the wafer surface. To accomplish program goals, Voxtel integrated and fabricated a stitched CMOS ROIC design, and bonded the ROIC to an array of thick, high-resistivity, fully depleted pinned silicon photodiodes, fabricated in a silicon-on-insulator (SOI) wafer. By fabricating the detector and ROIC separately, the silicon used to fabricate the circuits from the ROIC and the fully depleted, high-resistivity silicon detector array are optimized for their respective tasks, improving their performance, increasing yield, and reducing cost.

14 SOLAR ENERGY↗

Impact Damage Tolerance of Composite Laminates with Through-The-Thickness Stitches

The ability of through-the-thickness stitches to contain damage during a low-velocity impact event and increase the residual strength of stitched panels was investigated in this research. The impact response, spread of interlaminar delaminations, dent depth, surface damage, and static residual strength after impact were studied for carbon-epoxy specimens fabricated from HTS40 TohoTenax standard modulus fibers, stitched together with Vectran 1200 denier thread and infused with API 1078 resin after through-the-thickness stitching. Three different stitch patterns were used to explore the ability to arrest impact damage during and after impact. Simply supported boundary conditions were maintained during the impact testing. Non-destructive evaluations were performed using ultrasonic C-scans and X-ray computed tomography (CT) imaging to determine the shape, size, and location of delaminations. Results indicate that while the dynamic response during the impact event was almost the same for the unstitched specimens and all stitch patterns considered, the extent of delamination and the compression strength after impact varied greatly. For both the 60 J and 80 J impact energies, the delamination area was significantly less for the stitched specimens than for the unstitched specimens, but the range of delamination areas among the stitch patterns was much larger for the lower impact energy than for the greater impact energy. Similarly, while the presence of stitching influenced the compression after impact strength, the strength values for all stitch patterns were very similar. These results are a step toward quantifying the influence of through-the-thickness stitching.

Ranatunga, Vipul↗

Multimodal Broadband Vibrational Sum Frequency Generation (MM-BB-V-SFG) Spectrometer and Microscope

A broadband sum frequency generation (BB-SFG) spectrometer with multimodal (MM) capabilities was constructed, which could be routinely reconfigured for tabletop experiments in reflection, transmission, and total internal reflection (TIR) geometries, as well as microscopic imaging. The system was constructed using a Ti:sapphire amplifier (800 nm, pulse width = 85 fs, repetition rate = 2 kHz), an optical parameter amplification (OPA) system for production of broadband IR pulses tunable between 1000 and 4000 cm –1 , and two Fabry–Pérot etalons arranged in series for production of narrowband 800 nm pulses. The key feature allowing the MM operation was the nearly collinear alignment of the visible (fixed, 800 nm) and infrared (tunable, 1000–4000 cm –1 ) pulses which were spatially separated. Physical insights discussed in this paper include the comparison of spectral bandwidth produced with 40 and 85 fs pump beams, the improvement of spectral resolution using etalons, the SFG probe volume in bulk analysis, the normalization of SFG signals, the stitching of multiple spectral segments, and the operation in different modes for air/liquid and adsorbate/solid interfaces, bulk samples, as well as spectral imaging combined with principle component analysis (PCA). Finally, the SFG spectral features obtained with the MM-BB-SFG system were compared with those obtained with picosecond-scanning-SFG system and high-resolution BB-SFG system (HR-BB-SFG) for dimethyl sulfoxide, α-pinene, and various samples containing cellulose (purified commercial products, Cladophora cell wall, cotton and flax fibers, and onion epidermis cell wall).

47 OTHER INSTRUMENTATION↗

Mechanisms of compressive failure in 3D composites

The present study of angle-interlock woven polymer matrix composite behavior under uniaxial monotonic compression notes these materials to be macroscopically ductile, with compressive strains in failure that can exceed 15 percent. Some of the tests conducted on stitched laminates indicated brittle behavior. Woven composite failure mechanisms have been studied by a combination of optical microscopy, moire interferometry, stereoscopy, and digital image comparisons; the critical failure event was in all cases a kink band formation in the primary load-bearing axial rows.

Cox, B. N.↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of the compressive strengths for stitched and toughened composite systems

The compression strength of a stitched and a toughened matrix graphite/epoxy composite was determined and compared to a baseline unstitched untoughened composite. Two different layups with a variety of test lengths were tested under both ambient and hot/wet conditions. No significant difference in strength was seen for the different materials when the gage lengths of the specimens were long enough to lead to a buckling failure. For shorter specimens, a 30 percent reduction in strength from the baseline was seen due to stitching for both a 48-ply quasi-isotropic and a (0/45/0/-45/90/-45/0/45/0)s laminate. Analysis of the results suggested that the decrease in strength was due to increased fiber misalignment due to the stitches. An observed increasing strength with decreasing gage length, which was seen for all materials, was explained with a size effect model. The model assumed a random distribution of flaws (misaligned fibers). The toughened materials showed a small increase in strength over the baseline material for both laminates presumably due to the compensating effects of a more compliant matrix and straighter fibers in the toughened material. The hot/wet strength of the stitched and baseline material fell 30 percent below their ambient strengths for shorter, nonbuckling specimen, while the strength of the toughened matrix material only fell 20 percent. Video images of the failing specimen were recorded and showed local failures prior to global collapse of the specimen. These images support the theory of a random distribution of flaws controlling composite failure. Failed specimen appearance, however, seems to be a misleading indication of the cause of failure.

Reeder, James R.↗

Comparison of the Compressive Strengths for Stitched and Toughened Composite Systems

The compression strength of a stitched and a toughened matrix graphite/epoxy composite was determined and compared to a baseline unstitched untoughened composite. Two different layups with a variety of test lengths were tested under both ambient and hot/wet conditions. No significant difference in strength was seen for the different materials when the gage lengths of the specimens were long enough to lead to a buckling failure. For shorter specimens, a 30% reduction in strength from the baseline was seen due to stitching for both a 48-ply quasi-isotropic and a (0/45/0/-45/90/-45/0/45/0)s laminate. Analysis of the results suggested that the decrease in strength was due to increased fiber misalignment due to the stitches. An observed increasing strength with decreasing gage length, which was seen for all materials, was explained with a size effect model. The model assumed a random distribution of flaws (misaligned fibers). The toughened material showed a small increase in strength over the baseline material for both laminates presumably due to the compensating effects of a more compliant matrix and straighter fibers in the toughened material. The hot/wet strength of the stitched and baseline material fell 30% below their ambient strengths for shorter, non-buckling specimen, while the strength of the toughened matrix material only fell 20%. Video images of the failing specimen were recorded and showed local failures prior to global collapse of the specimen. These images support the theory of a random distribution of flaws controlling composite failure. Failed specimen appearance however, seems to be a misleading indication of the cause of failure.

Reeder, James R.↗

Multilayer Lateral Heterostructures of Van Der Waals Crystals with Sharp, Carrier–Transparent Interfaces

Abstract Research on engineered materials that integrate different 2D crystals has largely focused on two prototypical heterostructures: Vertical van der Waals stacks and lateral heterostructures of covalently stitched monolayers. Extending lateral integration to few layer or even multilayer van der Waals crystals could enable architectures that combine the superior light absorption and photonic properties of thicker crystals with close proximity to interfaces and efficient carrier separation within the layers, potentially benefiting applications such as photovoltaics. Here, the realization of multilayer heterstructures of the van der Waals semiconductors SnS and GeS with lateral interfaces spanning up to several hundred individual layers is demonstrated. Structural and chemical imaging identifies {110} interfaces that are perpendicular to the (001) layer plane and are laterally localized and sharp on a 10 nm scale across the entire thickness. Cathodoluminescence spectroscopy provides evidence for a facile transfer of electron‐hole pairs across the lateral interfaces, indicating covalent stitching with high electronic quality and a low density of recombination centers.

36 MATERIALS SCIENCE↗

Progressive Failure Studies of Stiffened Panels Subjected to Shear Loading

Experimental and analytical results are presented for progressive failure of stiffened composite panels with and without a notch and subjected to in plane shear loading well into their postbuckling regime. Initial geometric imperfections are included in the finite element models. Ply damage modes such as matrix cracking, fiber-matrix shear, and fiber failure are modeled by degrading the material properties. Experimental results from the test include strain field data from video image correlation in three dimensions in addition to other strain and displacement measurements. Results from nonlinear finite element analyses are compared with experimental data. Good agreement between experimental data and numerical results are observed for the stitched stiffened composite panels studied.

Ambur, Damodar R.↗

Data clustering for the high-resolution alignment of microstructure and strain fields

The emergence of small-scale deformation mapping by a combination of scanning electron microscopy and digital image correlation (SEM-DIC) has enabled full-field investigations into the complex roles of microstructure on microscale deformation mechanisms. However, these investigations are hindered by errors in alignment between the microstructure data, generally acquired by electron backscatter diffraction (EBSD), and the microscale strain data obtained by SEM-DIC. Distortions, stitching artifacts, and spatial resolution differences between microstructure and strain fields can lead to misalignments on the order of μms. This alignment uncertainty introduces error into microstructure-strain localization analyses and precludes the examination of deformation mechanisms near grain boundaries. To improve alignment between EBSD-obtained grain boundaries and SEM-DIC strain data, an approach was created wherein a mantle was first established around the EBSD-acquired grain boundaries. Strain data was then clustered within this mantle using a k-means algorithm to identify grain boundary strain localization, and these boundary points were fit to obtain a continuous curve for each individual boundary. Clustered point outliers, such as those due to grain boundary-local dislocation slip, were statistically identified by using an absolute error threshold and removed from the grain boundary fit. The ending identification of grain boundaries in the microscale strain data is significantly improved from EBSD-identified boundaries.

36 MATERIALS SCIENCE↗

Directing Charge Carriers and Ferroelectric Domains at Lateral Interfaces in van der Waals Heterostructures

Emergent phenomena in traditional ferroelectrics are frequently observed at heterointerfaces. Accessing such functionalities in van der Waals ferroelectrics requires the formation of layered heterostructures, either vertically stacked (similar to oxide ferroelectrics) or laterally stitched (without equivalent in 3D-crystals). Here, we investigate lateral heterostructures of the ferroelectric van der Waals semiconductors SnSe and SnS. A two-step process produces ultrathin crystals comprising an SnSe core laterally joined to an SnS edge-band, as confirmed by Raman spectroscopy, transmission electron microscopy (TEM) imaging, and electron diffraction. TEM shows a moiré pattern across the SnSe core due to coverage by an ultrathin SnS layer. The ability of the lateral interface (IF) to direct excited carriers, probed by cathodoluminescence, shows electron transfer over 560 nm diffusion length from the SnS edge-band. Large, thin flakes supporting ferroelectricity allow investigating domains and domain wall interactions in uniform crystals and lateral heterostructures. Polarized optical microscopy of sub-20 nm flakes consistently shows ⟨110⟩ oriented stripe domains with mirror-twin domain walls. Heterostructures adopt two domain configurations, with domains either constrained to the SnSe core or propagating across the entire SnSe–SnS flakes. Furthermore, the combined results demonstrate multifunctional van der Waals heterostructures with high-quality IFs presenting extraordinary opportunities for manipulating carrier flows and ferroelectric domain patterns.

2D ferroelectrics↗

aafcammovie (a1)

Cameras are installed in the cockpit of ARM’s research aircraft looking forward and on some campaigns in the belly of the plane looking down at the ground. When a single camera is flown, the higher resolution P1347 camera is placed in the cockpit. Otherwise, it is positioned in the nadir and the P1344 camera is placed in the cockpit. Both cameras take one picture per minute, which are then stitched into a flight-long video providing context for the measurements taken on board. The forward camera shows if the plane is in cloud or clear air. The nadir camera shows the surface the aircraft is flying over, such as land, water, or cloud, to provide insight into factors affecting the on-board nadir radiometers. The images are useful for determining vegetation cover as well.

54 ENVIRONMENTAL SCIENCES↗

System and method for parallel two-photon lithography using a metalens array

A metalens array is disclosed for controllably modifying a phase of a wavefront of an optical beam. The metalens array may have a substrate having at least first and second metalens unit cells, and forming a single integrated structure with no stitching being required of the first and second metalens unit cells. The first metalens unit cell has a first plurality of nanoscale features and is configured to modify a phase of a first portion of a wavefront of an optical signal incident thereon in accordance with a first predetermined phase pattern to create at least one first focal voxel within an image plane. The second metalens unit cell has a second plurality of nanoscale features configured to modify the phase of a second portion of the wavefront of the optical signal incident thereon, in accordance with a second predetermined phase pattern, to simultaneously create at least one second focal voxel within the image plane. Each metalens unit cell also has an overall diameter of no more than about 200 microns.

Xia, Xiaoxing↗

SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

60 APPLIED LIFE SCIENCES↗