Search NASA⌕ Search

SEARCH · Search NASA

Results for “image system blur”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Raw_data_Batch_I: Randall Road

Date of collection: June 3, 2022 Location: Randall Road, DuPage County, IL Content: “North to South” “South to North” This data set contains lidar and vision data collected along Randall Road in DuPage County, Illinois. The “South to North” folder starts at 1480 N. Orchard Road, Aurora, IL 60506, headed north along Randall Road until 238 N. Randall Road, St. Charles, IL 60174. The “North to South” folder starts from 238 N. Randall Road, St. Charles, IL 60174, headed south along Randall Road until 1480 N. Orchard Road, Aurora, IL. The data contains the following Robot Operating System (ROS) topics: - /Central_Camera_blurred – Image flow from coaxial camera heading, vehicle front. - /Left_Camera_blurred – Image flow from left camera, 60° from central camera on the left side. - /Right_Camera_blurred – Image flow from right camera, 60° from central camera on the right side. - /camera0/camera_info – Intrinsic and distortion information of left camera. - /camera0/projection_matrix – Extrinsic matrix of left camera from lidar. - /camera2/camera_info – Intrinsic and distortion information of central camera. - /camera2/projection_matrix – Extrinsic matrix of central camera from lidar. - /camera5/camera_info – Intrinsic and distortion information of right camera. - /camera5/projection_matrix – Extrinsic matrix of right camera from lidar. - /novatel/oem7/bestpos – Latitude, longitude, and elevation information from NovAtel GNSS-INS system. - /points_raw – VLP-32 lidar point cloud. - /tf – Vehicle base frame. The data are organized into a data description file and one or more ROS .bag files, dependent on original file size. The data description file provides information about the data collection date, location, and detailed mapping, while the .bag file(s) contain the actual data. Please note that for the purpose of securing personally identifiable information, all license plates and faces included in this publication have been intentionally blurred during real-time processing. ![randall road image](randall-road.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raw_data_Batch_I: State Street

Date of collection: May 18, 2023 Location: State Street, Chicago, IL This data set contains lidar and vision data collected along State Street. The vehicle started from outside of the McCormick Tribune Campus Center at the Illinois Institute of Technology’s Mies Campus and headed north along State Street, until the north end of State Street in the Gold Coast. The data contains the following Robot Operating System (ROS) topics: - /Central_Camera_blurred – Image flow from coaxial camera heading, vehicle front. - /Left_Camera_blurred – Image flow from left camera, 60° from central camera on the left side. - /Right_Camera_blurred – Image flow from right camera, 60° from central camera on the right side. - /camera0/camera_info – Intrinsic and distortion information of left camera. - /camera0/projection_matrix – Extrinsic matrix of left camera from lidar. - /camera2/camera_info – Intrinsic and distortion information of central camera. - /camera2/projection_matrix – Extrinsic matrix of central camera from lidar. - /camera5/camera_info – Intrinsic and distortion information of right camera. - /camera5/projection_matrix – Extrinsic matrix of right camera from lidar. - /novatel/oem7/bestpos – Latitude, longitude, and elevation information from NovAtel GNSS-INS system. - /points_raw – VLP-32 lidar point cloud. - /tf – Vehicle base frame. The data are organized into a data description file and one or more ROS .bag files, dependent on original file size. The data description file provides information about the data collection date, location, and detailed mapping, while the .bag file(s) contain the actual data. Please note that for the purpose of securing personally identifiable information, all license plates and faces included in this publication have been intentionally blurred during real-time processing. ![state street image](state-street.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fresnel Lenses for Wide-Aperture Optical Receivers

Wide-aperture receivers for freespace optical communication systems would utilize Fresnel lenses instead of conventional telescope lenses, according to a proposal. Fresnel lenses weigh and cost much less than conventional lenses having equal aperture widths. Plastic Fresnel lenses are commercially available in diameters up to 5 m large enough to satisfy requirements for aperture widths of the order of meters for collecting sufficient light in typical long-distance free-space optical communication systems. Fresnel lenses are not yet suitable for high-quality diffraction-limited imaging, especially in polychromatic light. However, optical communication systems utilize monochromatic light, and there is no requirement for high-quality imaging; instead, the basic requirement for an optical receiver is to collect the incoming monochromatic light over a wide aperture and concentrate the light onto a photodetector. Because of lens aberrations and diffraction, the light passing through any lens is focused to a blur circle rather than to a point. Calculations for some representative cases of wide-aperture non-diffraction-limited Fresnel lenses have shown that it should be possible to attain blur-circle diameters of less than 2 mm. Preferably, the blur-circle diameter should match the width of the photodetector. For most high-bandwidth communication applications, the required photodetector diameters would be about 1 mm. In a less-preferable case in which the blur circle was wider than a single photodetector, it would be possible to occupy the blur circle with an array of photodetectors. As an alternative to using a single large Fresnel lens, one could use an array of somewhat smaller lenses to synthesize the equivalent aperture area. Such a configuration might be preferable in a case in which a single Fresnel lens of the requisite large size would be impractical to manufacture, and the blur circle could not be made small enough. For example one could construct a square array of four 5-m-diameter Fresnel lenses to obtain the same light-collecting area as that of a single 10-m-diameter lens. In that case (see figure), the light collected by each Fresnel lens could be collimated, the collimated beams from the four Fresnel lenses could be reflected onto a common offaxis paraboloidal reflector, and the paraboloidal reflector would focus the four beams onto a single photodetector. Alternatively, detected signal from each detector behind each lens would be digitized before summing the signals.

Hemmati, Hamid↗

Development of Thermal Tomography Imaging System for In-Service Nondestructive Evaluation of Additively Manufactured Components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. We investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin. MIT research reactor (MITR) has been identified as a representative environment to perform investigation of feasibility of in-service NDE during shutdown. Preliminary study of radiation level in the MITR viewport, with geometric parameters potentially compatible with compact TT system, has been conducted.

36 MATERIALS SCIENCE↗

Pursuit Eye Movements

When viewing objects, primates use a combination of saccadic and pursuit eye movements to stabilize the retinal image of the object of regard within the high-acuity region near the fovea. Although these movements involve widespread regions of the nervous system, they mix seamlessly in normal behavior. Saccades are discrete movements that quickly direct the eyes toward a visual target, thereby translating the image of the target from an eccentric retinal location to the fovea. In contrast, pursuit is a continuous movement that slowly rotates the eyes to compensate for the motion of the visual target, minimizing the blur that can compromise visual acuity. While other mammalian species can generate smooth optokinetic eye movements - which track the motion of the entire visual surround - only primates can smoothly pursue a single small element within a complex visual scene, regardless of the motion elsewhere on the retina. This ability likely reflects the greater ability of primates to segment the visual scene, to identify individual visual objects, and to select a target of interest.

Krauzlis, Rich↗

Formulation of the information capacity of the optical-mechanical line-scan imaging process

An expression for the information capacity of the optical-mechanical line-scan imaging process is derived which includes the effects of blurring of spatial, photosensor noise, aliasing, and quantization. Both the information capacity for a fixed data density and the information efficiency (the ratio of information capacity to data density) exhibit a distinct single maximum when displayed as a function of sampling rate, and the location of this maximum was determined by the system frequency-response shape, signal-to-noise ratio, and quantization interval.

Huck, F. O.↗

Spatial acquisition and tracking for deep-space optical communication packages

The problem of acquiring and tracking a sun-lit earth, which poses a rather stringent demand on the design of the pointing acquisition and tracking subsystem for a deep-space optical communication package, is addressed. The acquisition subsystem must be capable of locating and tracking the receiver location based on a sun-lit earth image that is blurred by the point spread function of the imaging optics and spatially quantized by the detector pixels. Spatial tracking must be performed at bandwidths in excess of 1 kHz to effectively reject platform jitters. A simple solution of locating the earth limb shows a great potential for providing the necessary acquisition and tracking accuracy. By using separate acquisition and tracking detectors, the system can be implemented without extensive technology development. The slow bandwidth required for the acquisition process can be readily accomplished with an available CCD array, and an analog tracking loop can be implemented using a quadrant tracker and calibrated centroid tracking without the excessive computing overhead of the array detector-based spatial tracker.

Chen, Chien-Chung↗

Incorporation of shuttle CCT parameters in computer simulation models

Computer simulations of shuttle missions have become increasingly important during recent years. The complexity of mission planning for satellite launch and repair operations which usually involve EVA has led to the need for accurate visibility and access studies. The PLAID modeling package used in the Man-Systems Division at Johnson currently has the necessary capabilities for such studies. In addition, the modeling package is used for spatial location and orientation of shuttle components for film overlay studies such as the current investigation of the hydrogen leaks found in the shuttle flight. However, there are a number of differences between the simulation studies and actual mission viewing. These include image blur caused by the finite resolution of the CCT monitors in the shuttle and signal noise from the video tubes of the cameras. During the course of this investigation the shuttle CCT camera and monitor parameters are incorporated into the existing PLAID framework. These parameters are specific for certain camera/lens combinations and the SNR characteristics of these combinations are included in the noise models. The monitor resolution is incorporated using a Gaussian spread function such as that found in the screen phosphors in the shuttle monitors. Another difference between the traditional PLAID generated images and actual mission viewing lies in the lack of shadows and reflections of light from surfaces. Ray tracing of the scene explicitly includes the lighting and material characteristics of surfaces. The results of some preliminary studies using ray tracing techniques for the image generation process combined with the camera and monitor effects are also reported.

Huntsberger, Terry↗

Phase retrieval for the Hubble Space Telescope using iterative propagation algorithms

Phase retrieval algorithms, including the iterative transform algorithm and gradient search algorithms, were generalized to include the effects of propagation through a complicated optical system and to discount the effects of bad CCD pixels. For the gradient search algorithms, analytic gradients were derived that greatly speed up the computation over finite difference methods. For the Hubble Space Telescope (HST), the aperture function was reconstructed and the phase errors were retrieved. This information is useful to design correction optics for the telescope and for the deconvolution of blurred images from the HST.

Fienup, J. R.↗

Stroboscopic Goggles as a Countermeasure for Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing, the vestibular system and the central nervous system, responsible for coordinating head and eye movements via the vestibulo-occular reflex (VOR), are adapted to microgravity and must re-adapt to the Earth's gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. These effects are caused by retinal slip, or the inability to keep an image focused on their retina, which is thought to drive motion sickness symptoms experienced upon landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Peters et al. (2011) find that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. Previously, the use of stroboscopic goggles has shown to be effective in minimizing motion sickness symptoms due to retinal slip (Reschke et al. 2007). In this study, we simulated the decrement in DVA caused by sensorimotor re-adaptation by using minifying lenses and then testing the efficacy of stroboscopic goggles in preventing retinal slip and improving DVA. Dynamic visual acuity is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is motor-driven and oscillates vertically at 2 Hz with a vertical displacement of +/- 2 cm to simulate the vertical translations that occur while walking. As the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous responses of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. We found that healthy subjects (n=20) have a significantly impaired DVA while wearing the minifying lenses, demonstrating that the VOR is in an adaptive state and retinal slip is occurring. When subjects' acuity was tested wearing the stroboscopic goggles with the minifying lenses, there was no significant difference in their DVA compared to their baseline DVA. This suggests that stroboscopic goggles are preventing retinal slip and would function as an efficient countermeasure for VOR adaptations and thus help mitigate landing sickness symptoms experienced by long-duration crewmembers. These goggles might also be used to counter blurred vision (caused by retinal slip) experienced by crewmembers during launch where the vehicle vibrations are greatest. The stroboscopic effect could be built into a section of their head mounted displays on the visor of their helmets to be used in these high vibration situation if a mission critical task is necessary.

Rosenberg, M. J. F.↗

Performance of Pulsed Thermal Tomography Imaging with Machine Learning-Based Classification of Defects in Additively Manufactured Structures

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures non-destructively. Pulsed Thermal Tomography Imaging (PTT) provides a capability for non-destructive evaluation (NDE) of subsurface defects in arbitrary size structures. The PTT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PTT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PTT system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PTT capabilities in detecting and visualizing microscopic defects in metallic specimens. The thermal tomography (TT) algorithm obtains depth reconstructions of spatial effusivity from the data cube of sequentially recorded surface temperatures. However, interpretation of TT images is non-trivial because of blurring of images with increasing depth. To address this challenge, we have developed a deep learning convolutional neural network (CNN) to classify size and orientation subsurface defects in simulated TT images. CNN is trained on a database of TT images created for a set of simulated metallic structures with elliptical subsurface voids. Test of CNN performance demonstrate the ability to classify radii and angular orientation of subsurface defects in TT images. In addition, we have shown that CNN trained on elliptical defects is capable of classifying irregular-shaped defects obtained from scanning electron microscopy (SEM) of stainless steel sections printed with LPBF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experiments with recursive estimation in astronomical image processing

Recursive estimation concepts were applied to image enhancement problems since the 70's. However, very few applications in the particular area of astronomical image processing are known. These concepts were derived, for 2-dimensional images, from the well-known theory of Kalman filtering in one dimension. The historic reasons for application of these techniques to digital images are related to the images' scanned nature, in which the temporal output of a scanner device can be processed on-line by techniques borrowed directly from 1-dimensional recursive signal analysis. However, recursive estimation has particular properties that make it attractive even in modern days, when big computer memories make the full scanned image available to the processor at any given time. One particularly important aspect is the ability of recursive techniques to deal with non-stationary phenomena, that is, phenomena which have their statistical properties variable in time (or position in a 2-D image). Many image processing methods make underlying stationary assumptions either for the stochastic field being imaged, for the imaging system properties, or both. They will underperform, or even fail, when applied to images that deviate significantly from stationarity. Recursive methods, on the contrary, make it feasible to perform adaptive processing, that is, to process the image by a processor with properties tuned to the image's local statistical properties. Recursive estimation can be used to build estimates of images degraded by such phenomena as noise and blur. We show examples of recursive adaptive processing of astronomical images, using several local statistical properties to drive the adaptive processor, as average signal intensity, signal-to-noise and autocorrelation function. Software was developed under IRAF, and as such will be made available to interested users.

Busko, I.↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning From Long-Duration Spaceflight

Long-duration spaceflight results in sensorimotor adaptations, which cause functional deficits during gravitational transitions, such as landing on a planetary surface after long-duration microgravity exposure. Both the vestibular system and the central nervous system are affected by gravitational transitions. These systems are responsible for coordinating head and eye movements via the vestibulo-ocular reflex (VOR) and go through an adaptation period upon exposure to microgravity. Consequently, they must also re-adapt to Earth's gravitational environment upon landing. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with crewmembers reporting oscillopsia and blurred vision caused by retinal slip, or the inability to keep an image focused on their retina. This is thought to drive motion sickness symptoms experienced by most crewmembers following landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Previously, DVA has been assessed in the laboratory where subjects walked at 6.4 km/hr on a motorized treadmill. Using this method, Peters et al. (2011) found that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. However, it is believed that re-adaptation occurs quickly and that DVA might be worse immediately upon re-exposure to a gravitational environment. Since many crewmembers are unable to walk safely upon landing, it was necessary to develop a method for replicating the vertical head movements associated with walking. In addition, the use of a chair to imitate the head displacement caused by walking isolates eye-head interactions without allowing for trunk and lower-body compensation, as seen with treadmill walking (Mulavara & Bloomberg 2003). Therefore, a modality for assessing DVA in the field within a few hours of landing was developed. In this study, we validated the ability of a manually operated oscillating chair to reproduce the oscillatory frequency of walking on a treadmill. Healthy non-astronaut subjects (n=14) participated in one test session and completed three static (seated) and three dynamic (walking/oscillated) visual acuity tests. DVA was assessed using a motorized treadmill, an automated oscillating chair, and a manually operated chair, both developed in the Neuroscience Laboratory at JSC. The automated chair was motor-driven and set to oscillate vertically at 2 Hz with a vertical displacement of +/- 5 cm to simulate vertical translation while walking. The manually operated chair was oscillated vertically by a test operator to the beat of a metronome at 120 beats/min (2 Hz) and a vertical displacement of approximately +/- 5 cm. As the subject was oscillated, they were asked to discern the direction gap of Landolt-C optotypes of varying sizes and verbally reported the direction while an operator recorded their response using a gamepad. Subjects were outfitted with accelerometers (sampling rate = 128 Hz) on their head, trunk and lumbar spine. A fast Fourier transform was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. The spread of the frequency distribution for the manual chair was not significantly different from either the treadmill or the automated chair. However, all three conditions had similar non-zero standard error values, suggesting a variance in head movement frequency which may affect DVA. The average oscillation frequency of the manual chair (1.85 Hz) was significantly different (α=0.05) from that of treadmill walking (2.24 Hz), but not significantly different from that of the automated chair (1.85 Hz) and all three conditions had small standard errors (SEM = 0.04, 0.06, and 0.08 Hz for manual, treadmill, and automated respectively). This implies that both chairs oscillate at a frequency below that of treadmill walking, but are comparable to each other and reproducible across sessions. Additionally, DVA scores did not vary significantly across conditions. The smaller spread values of the oscillating chairs' frequencies indicated mitigation of variation induced by locomotor strategies, which enables better examination of the issue of VOR adaptation. Furthermore, due to the deconditioned state of crewmembers in the initial hours after landing, it is easier to transport a manual bouncing chair into the field and safer to perform a vision test while seated in a chair versus walking on a treadmill. Therefore, the manually oscillating chair has been deemed to meet and exceed the DVA testing capabilities previously obtained by treadmill walking.

Kreutzberg, G. A.↗

Reducing Artifacts in BF and HAADF-STEM Images of Pt/C Fuel Cells using MBIR-ARAR

Electron tomography is a powerful tool for characterization of three-dimensional (3D) nanoscale materials and devices. Bright-field (BF) and high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) are two widely used imaging modes in electron tomography. These imaging modalities have proven to be useful for characterizing the structure of carbon-supported platinum (Pt/C) electrocatalysts used in fuel cells, which are an important class of clean energy conversion systems. BF and HAADF-STEM images are typically simultaneously acquired due to the complementary information they contain, as BF-STEM is more suitable for characterizing carbon due to its ability to detect lighter elements, while HAADF-STEM is more suitable for characterizing platinum due to its sensitivity to atomic number. However, the quality of BF- and HAADF-STEM images is often compromised by various artifacts, such as local blurring due to abrupt contrast changes as well as missing wedge artifacts which can severely impact the accuracy of the reconstructed 3D images. The traditional methods of reconstruction, such as Filtered Back-projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT), and Model-Based Iterative Reconstruction (MBIR), are often not suitable for removing these artifacts effectively. Here, to address this challenge, we present a novel approach called MBIR with Artifact Reduction and Adaptive Regularization (MBIR-ARAR).

25 ENERGY STORAGE↗

Characterizing degraded visual environments with scanning lenses to improve contrast recovery

Atmospheric aerosols, such as fog and smoke, degrade optical signals via the scattering and absorption of light, making it difficult to recover information from the surrounding environment. Here, we present a technique that measures the angular distribution of light in scattering environments to help recover these degraded optical signals. This is done by passing a collimated beam through the aerosol environment and collecting the scattered and unscattered light with an f-theta scan lens. The lens transforms the angular distribution of the scattered light into the linear domain, mapping the collected light onto a detector. The measured angular scattering distribution is then used to estimate the point spread function of the environment at an arbitrary stand-off distance. This point spread function can be used to deconvolve images blurred by the aerosol environment in which the angular scattering distribution was initially measured. With this approach, we demonstrate improvements in the effective resolution of deblurred images up to 26% over a 120-cm stand-off distance. Experimentation was performed in the Sandia National Laboratories tabletop fog chamber, a platform that generates aerosol environments analogous to real-world fogs. We intend to leverage this technique in future work to develop a low-SWaP system for the in situ characterization of aerosol environments.

Aerosols↗

Visible Motion Blur

A method of measuring motion blur is disclosed comprising obtaining a moving edge temporal profile r(sub 1)(k) of an image of a high-contrast moving edge, calculating the masked local contrast m(sub1)(k) for r(sub 1)(k) and the masked local contrast m(sub 2)(k) for an ideal step edge waveform r(sub 2)(k) with the same amplitude as r(sub 1)(k), and calculating the measure or motion blur Psi as a difference function, The masked local contrasts are calculated using a set of convolution kernels scaled to simulate the performance of the human visual system, and Psi is measured in units of just-noticeable differences.

Watson, Andrew B.↗

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao↗

Fabrication of X-ray telescopes for sounding rocket flights

Two X-ray telescopes and two detector systems were fabricated, and one of the telescopes (15 in. diameter, Wolter type I telescope) was flown on two sounding rocket flights. The telescopes were fabricated using the diamond point technique which provided the accurate figure of the mirrors to about a focal plane blur of 0.5 arc minutes. The 15 in. telescope mirrors were polished using standard polishing techniques to remove tooling marks from the diamond turning, then chemically polished to bring the X-ray reflectivity up to nearly the theoretical values. The optical image formed by the 15 in. telescope was found to produce a blur of about 40 arc seconds for a parallel beam of incoming laser light. The first flight of the telescope produced an X-ray image of Capella which indicated that the X-ray image was blurred to the extent of about 2 arc minutes. This additional image degradation was due to a slight error in focusing the X-ray image onto the detector.

Source record↗