Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Method for image reconstruction of moving radionuclide source distribution

A method for image reconstruction of moving radionuclide distributions. Its particular embodiment is for single photon emission computed tomography (SPECT) imaging of awake animals, though its techniques are general enough to be applied to other moving radionuclide distributions as well. The invention eliminates motion and blurring artifacts for image reconstructions of moving source distributions. This opens new avenues in the area of small animal brain imaging with radiotracers, which can now be performed without the perturbing influences of anesthesia or physical restraint on the biological system.

47 OTHER INSTRUMENTATION↗

Applying image processing methods to study hydrodynamic characteristics in a rectangular spouted bed

This paper presents systematic image processing methods for investigating hydrodynamic characteristics in a rectangular spouted bed (30.2 mm × 101.6 mm). The objective is to provide a non-intrusive technique to determine the bed expansion ratio, the jet height and the fountain height due to their significant influence on the hydrodynamics of the entire bed. A high-speed video camera is used in the experiment with Geldart D particles as the bed material. After the image acquisition, image denoising, thresholding, logical and mask operations are applied correspondingly for the boundary discrimination, based on which an algorithm has been developed to determine the bed height successfully. With the discriminated boundary, morphological operations viz. erosion and dilation have been used to accurately determine the jet height and the fountain height. The feasibility of the technique is proven through profiles of bed expansion ratio, jet height and fountain height under three initial bed heights (0.0762 m, 0.102 m, and 0.127 m) for two different nozzle sizes (0.0096 m and 0.0127 m). Depending on the determination of the hydrodynamic characteristics, different flow regimes can be distinguished comprehensively through profiles of the bed expansion ratio and bed pressure drop in combination with the standard deviation of jet/fountain height. The proposed flow regime discrimination verifies the feasibility and effectiveness of the image processing methods in assessing the solids behavior in the spouted beds. Results about the variation of the jet height and the fountain height under current operating conditions as determined by the new technique are also discussed.

20 FOSSIL-FUELED POWER PLANTS↗

The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real-time image guidance method

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time image guidance method that uses widely available radiotherapy technology, i.e., a gantry-mounted x-ray imager. The authors report on the geometric and dosimetric results of the first patient treatment using KIM which occurred on September 16, 2014. Methods: KIM uses current and prior 2D x-ray images to estimate the 3D target position during cancer radiotherapy treatment delivery. KIM software was written to process kilovoltage (kV) images streamed from a standard C-arm linear accelerator with a gantry-mounted kV x-ray imaging system. A 120° pretreatment kV imaging arc was acquired to build the patient-specific 2D to 3D motion correlation. The kV imager was activated during the megavoltage (MV) treatment, a dual arc VMAT prostate treatment, to estimate the 3D prostate position in real-time. All necessary ethics, legal, and regulatory requirements were met for this clinical study. The quality assurance processes were completed and peer reviewed. Results: During treatment, a prostate position offset of nearly 3 mm in the posterior direction was observed with KIM. This position offset did not trigger a gating event. After the treatment, the prostate motion was independently measured using kV/MV triangulation, resulting in a mean difference of less than 0.6 mm and standard deviation of less than 0.6 mm in each direction. The accuracy of the marker segmentation was visually assessed during and after treatment and found to be performing well. During treatment, there were no interruptions due to performance of the KIM software. Conclusions: For the first time, KIM has been used for real-time image guidance during cancer radiotherapy. The measured accuracy and precision were both submillimeter for the first treatment fraction. This clinical translational research milestone paves the way for the broad implementation of real-time image guidance to facilitate the detection and correction of geometric and dosimetric errors, and resultant improved clinical outcomes, in cancer radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-I-20: Dead Time Count Loss Compensation in SPECT/CT: Projection Versus Global Correction

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

SU-E-I-21: Deformation Mapping and Shape Prediction with 3D Tumor Volume Morphing

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

Method of imaging the electrical conductivity distribution of a subsurface

A method of imaging electrical conductivity distribution of a subsurface containing metallic structures with known locations and dimensions is disclosed. Current is injected into the subsurface to measure electrical potentials using multiple sets of electrodes, thus generating electrical resistivity tomography measurements. A numeric code is applied to simulate the measured potentials in the presence of the metallic structures. An inversion code is applied that utilizes the electrical resistivity tomography measurements and the simulated measured potentials to image the subsurface electrical conductivity distribution and remove effects of the subsurface metallic structures with known locations and dimensions.

36 MATERIALS SCIENCE↗

SU-G-IeP3-09: Investigating the Interplay of Antiscatter Grids with Modern Detectors and Image Processing in Digital Radiography

Purpose: To use phantom and simulation experiments to relate technique factors, patient size and antiscatter grid use to image quality in portable digital radiography (DR), in light of advancements in detector design and image processing. Methods: Image contrast-to-noise ratio (CNR) on a portable DR system (MobileDaRt Evolution, Shimadzu) was measured by imaging four aluminum inserts of varying thickness, superimposed on a Lucite slab phantom using a pediatric abdominal protocol. Three thicknesses of Lucite were used: 6.1cm, 12cm, and 18.2cm, with both 55 and 65 kVp beams. The mAs was set so that detector entrance exposure (DEE) was matched between kVp values. Each technique and phantom was used with and without an antiscatter grid (focused linear grid embedded in aluminum with an 8:1 ratio). The CNR-improvement-factor was then used to determine the thickness- and technique-dependent appropriateness of grid use. Finally, the same experiment was performed via Monte Carlo simulation, integrating incident energy fluence at each detector pixel, so that effects of detector design and image processing could be isolated from physical factors upstream of the detector. Results: The physical phantom experiment demonstrated a clear improvement for the lower tube voltage (55kVp), along with substantial CNR benefits with grid use for 12–18cm phantoms. Neither trend was evident with Monte Carlo, suggesting that suboptimal quantum-detection-efficiency and automated grid-removal could explain trends in kVp and grid use, respectively. Conclusion: Physical experiments demonstrate marked improvement in CNR when using a grid for phantoms of 12 and 18cm Lucite thickness (above ∼10cm soft-tissue equivalent). This benefit is likely due to image processing, as this result was not seen with Monte Carlo. The impact of image processing on image resolution should also be investigated, and the CNR benefit of low kVp and grid use should be weighed against the increased exposure time necessary to achieve adequate DEE.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-06: Impact of Temporal Image Coregistration Methods On 3D Internal Dose Calculations in Targeted Radionuclide Therapy

Purpose: The calculation of 3D internal dose calculations in targeted radionuclide therapy requires the acquisition and temporal coregistration of a serial PET/CT or SPECT/CT images. This work investigates the dosimetric impact of different temporal coregistration methods commonly used for 3D internal dosimetry. Methods: PET/CT images of four mice were acquired at 1, 24, 48, 72, 96, 144 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose rate (ADR) was calculated at each time point using a Geant4-based MC dosimetry platform using three temporal image coregistration Methods: (1) no coregistration (NC), whole body sequential CT-CT affine coregistration (WBAC), and individual sequential ROI-ROI affine coregistration (IRAC). For NC, only the ROI mean ADR was integrated to obtain ROI mean doses. For WBAC, the CT at each time point was coregistered to a single reference CT. The CT transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the whole CT volume. For IRAC, each individual ROI was isolated and sequentially coregistered to a single reference ROI. The ROI transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the ROI volumes. Results: The percent differences in the ROI mean doses were as large as 109%, 88%, and 32%, comparing the WBAC vs. IRAC, NC vs. IRAC, and NC vs. WBAC methods, respectively. The CoV in the mean dose between the all three methods ranged from 2–36%. The pronounced curvature of the spinal cord was not adequately coregistered using WBAC which resulted in large difference between the WBAC and IRAC. Conclusion: The method used for temporal image coregistration can result in large differences in 3D internal dosimetry calculations. Care must be taken to choose the most appropriate method depending on the imaging conditions, clinical site, and specific application. This work is partially funded by NIH Grant R21 CA198392-01.

60 APPLIED LIFE SCIENCES↗

Two worlds collide: Image analysis methods for quantifying structural variation in cluster molecular dynamics

Inspired by methods of remote sensing image analysis, we analyze structural variation in cluster molecular dynamics (MD) simulations through a unique application of the principal component analysis (PCA) and Pearson Correlation Coefficient (PCC). The PCA analysis characterizes the geometric shape of the cluster structure at each time step, yielding a detailed and quantitative measure of structural stability and variation at finite temperature. Our PCC analysis captures bond structure variation in MD, which can be used to both supplement the PCA analysis as well as compare bond patterns between different cluster sizes. Relying only on atomic position data, without requirement for a priori structural input, PCA and PCC can be used to analyze both classical and ab initio MD simulations for any cluster composition or electronic configuration. Taken together, these statistical tools represent powerful new techniques for quantitative structural characterization and isomer identification in cluster MD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Michigan New Technology Training and Research (MNTR) Translational Program in Nuclear Medicine (Final Report)

The Michigan New Technology Training and Research (MNTR) Translational Program in Nuclear Medicine and Molecular Imaging This project established the Michigan New Technology Training and Research (MNTR) translational program, focused on the acceleration of new clinical molecular imaging methods. Molecular imaging approaches to imaging are a very flexible and powerful development, with many recent examples advancing the diagnosis and guiding the management of human disease. These methods depend on the design, synthesis and testing of new radiotracers (molecules designed to target specific cells or tissues in the body), labeled with short-lived radioactive atoms (positron emitters). The new radiotracers are imaged in the human body using positron emission tomography (PET) imaging. The University of Michigan PET Center has considerable experience in the discovery, development, refinement and initial human applications of new PET radiotracers. An emerging impediment to efficient availability of new PET radiotracers, however, involves the regulatory environment at multiple levels. Many potentially successful ideas are delayed or even prevented from entering human use by these barriers. In the current grant, we provided hands-on experience for the next generation of young scientists working in molecular imaging so that they are equipped to effectively move new ideas and radiotracers from the research laboratory to the nuclear medicine clinic (bench-to-bedside). For new radiotracer development, oversight by the Food and Drug Administration (FDA), the Nuclear Regulatory Commission (NRC), and local institutional committees and reviews are required. These aspects of translation from laboratory to clinic are often omitted from the formal training of new scientists, but were provided to three trainees via direct mentorship in the MNTR program. The MNTR training program built on the translational successes of the University of Michigan Division of Nuclear Medicine and capitalized on our strengths (facilities, faculty, a wide-ranging selection of projects, and the experience and commitment to bring new radiotracers into human studies) to systematically train three fellows in radiochemistry and nuclear medicine. Integrated training in development, validation and clinical translation of new PET radiotracers occurred through practical involvement in multiple research projects, each at a different stage along the pathway from bench-to-bedside. Each trainee obtained experience of the entire process over about 2 years. Projects involved development of new radiotracers for neurodegenerative disorders (e.g. Alzheimer disease), movement disorders (e.g. Parkinson disease, progressive supranuclear palsy) and neurodevelopmental syndromes (e.g. Tourette syndrome) as well as new radiochemistry methods for synthesizing radiotracers. Each project was pursued in a close collaboration between the fellow trainee and both the clinical and basic science faculty at the University of Michigan PET Center, and provided an unprecedented opportunity for the highest-level training in academic radiochemistry and nuclear medicine research. The project has resulted in 17 peer-reviewed publications to date, and at least 4 more are in preparation. Additionally, 1 book chapter and 26 conference presentations have resulted from this grant. Upon completion of the MNTR Program, the trainees have emerged as translational scientists wielding the necessary skill-set (practical research experience, multidisciplinary training, regulatory know-how) to embark on successful careers in translational molecular imaging, bringing continued advances in the field to bear on important human disorders. As a metric of the Program’s success, one fellow has already secured employment in the field, while the other two are finishing writing papers; they wish to also stay in the radiochemistry and nuclear medicine community, and are currently applying for jobs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Reflection Optical Imaging to Study Oxygen Evolution Reactions

Discovery of high-efficiency water-splitting catalysts is critical for clean hydrogen fuel generation. Quantitative and reliable chemical imaging methods can play a crucial role in providing critical catalyst efficiency information for materials development and screening. Here, we developed a reflection optical imaging method to map the performance of transition metal oxide catalysts for oxygen evolution reaction (OER). The generated high concentration of oxygen in the electrolyte will decrease the refractive index of the solutions near the electrode and change the reflectivity of optical images. We successfully imaged and measured the OER on cobalt oxide, and the localized current density and overpotential distribution maps have been extracted. The oxidation and reduction of cobalt oxide can be imaged with our reflection optical imaging method as well. These maps showed that the catalytic activities are quite different at different locations, and some regions showed much higher activities. This is due to the non-uniformity created by the catalyst synthesis process and demonstrates the importance of using the optical imaging method to map the localized catalytic efficiency. In addition, the NiFe alloy’s OER catalytic activities have been studied as well. The proposed reflection optical imaging method could find many applications in catalyst activity measurement and screening.

Electrochemistry↗

Comparative analysis of image binarization methods for crack identification in concrete structures

Surface cracks in concrete structures are critical indicators of structural damage and durability. Manual visual inspection, the most commonly used method in practice, is inefficient from cost, time, accuracy, and safety perspectives. A promising alternative is computer vision-based methods that can automatically extract crack information from images. Image binarization, developed for text detection, is appropriate for crack identification, as texts and cracks are similar, consisting of distinguishable lines and curves. However, standardizing crack identification using image binarization is challenging, because binarization depends on the method and associated parameters. We investigate image binarization for crack identification, focusing on optimal parameter determination and comparative performance evaluation for five common binarization methods. Crack images are prepared to obtain optimal parameters by minimizing errors in estimated crack widths. Subsequently, comparative analysis is conducted using crack images with different conditions based on three performance evaluation criteria: crack width and length measurement accuracy and computation time.

36 MATERIALS SCIENCE↗

Mimicking of corruption in images

Methods and systems are provided to generate an uncorrupted version of an image given an observed image that is a corrupted version of the image. In some embodiments, a corruption mimicking (“CM”) system iteratively trains a corruption mimicking network (“CMN”) to generate corrupted images given modeled images, updates latent vectors based on differences between the corrupted images and observed images, and applies a generator to the latent vectors to generate modeled images. The training, updating, and applying are performed until modeled images that are input to the CMN result in corrupted images that approximate the observed images. Because the CMN is trained to mimic the corruption of the observed images, the final modeled images represented the uncorrupted version of the observed images.

Anirudh, Rushil↗

Imaging systems and related methods including radar imaging with moving arrays or moving targets

Imaging systems, including radio frequency, microwave and millimeter-wave arrangements, and related methods are described. According to one aspect, an imaging system includes an antenna array, a position capture system configured to generate position information indicative of locations of one of the antenna array and the target at the first and second moments in time, and wherein the one of the antenna array and the target move between the first and second moments in time, a transceiver configured to control the antenna array to emit electromagnetic energy towards the target and to generate an output that is indicative of the received electromagnetic energy, a data acquisition system configured to generate radar data, processing circuitry configured to process the position information and the radar data to generate image data regarding the target, and an interface configured to use the image data to generate visual images regarding the target.

Sheen, David M.↗

Imaging systems and related methods including radar imaging with moving arrays or moving targets

Imaging systems, including radio frequency, microwave and millimeter-wave arrangements, and related methods are described. According to one aspect, an imaging system includes an antenna array, a position capture system configured to generate position information indicative of locations of one of the antenna array and the target at the first and second moments in time, and wherein the one of the antenna array and the target move between the first and second moments in time, a transceiver configured to control the antenna array to emit electromagnetic energy towards the target and to generate an output that is indicative of the received electromagnetic energy, a data acquisition system configured to generate radar data, processing circuitry configured to process the position information and the radar data to generate image data regarding the target, and an interface configured to use the image data to generate visual images regarding the target.

Sheen, David M.↗

Three-dimensional Fréchet sensitivity kernels for electromagnetic wave propagation

Electromagnetic imaging methods are useful tools for monitoring subsurface changes in pore-fluid content and the associated changes in electrical permittivity and conductivity. The most common method for georadar tomography uses a high frequency ray-theoretic approximation that is valid when material variations are sufficiently small relative to the wavelength of the propagating wave. Georadar methods, however, often utilize electromagnetic waves that propagate within heterogeneous media at frequencies where ray theory may not be applicable. In this paper we describe the 3-D Fréchet sensitivity kernels for EM wave propagation. Various data functional types are formulated that consider all three components of the electric wavefield and incorporate near-, intermediate-, and far-field contributions. We show that EM waves exhibit substantial variations for different relative source-receiver component orientations. The 3-D sensitivities also illustrate out-of-plane effects that are not captured in 2-D sensitivity kernels and can influence results obtained using 2-D inversion methods to image structures that are in reality 3-D.

58 GEOSCIENCES↗

SU-D-18C-05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping

Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion.

60 APPLIED LIFE SCIENCES↗

SU-D-201-06: Random Walk Algorithm Seed Localization Parameters in Lung Positron Emission Tomography (PET) Images

Purpose: The objective of this study was to find the best seed localization parameters in random walk algorithm application to lung tumor delineation in Positron Emission Tomography (PET) images. Methods: PET images suffer from statistical noise and therefore tumor delineation in these images is a challenging task. Random walk algorithm, a graph based image segmentation technique, has reliable image noise robustness. Also its fast computation and fast editing characteristics make it powerful for clinical purposes. We implemented the random walk algorithm using MATLAB codes. The validation and verification of the algorithm have been done by 4D-NCAT phantom with spherical lung lesions in different diameters from 20 to 90 mm (with incremental steps of 10 mm) and different tumor to background ratios of 4:1 and 8:1. STIR (Software for Tomographic Image Reconstruction) has been applied to reconstruct the phantom PET images with different pixel sizes of 2×2×2 and 4×4×4 mm{sup 3}. For seed localization, we selected pixels with different maximum Standardized Uptake Value (SUVmax) percentages, at least (70%, 80%, 90% and 100%) SUVmax for foreground seeds and up to (20% to 55%, 5% increment) SUVmax for background seeds. Also, for investigation of algorithm performance on clinical data, 19 patients with lung tumor were studied. The resulted contours from algorithm have been compared with nuclear medicine expert manual contouring as ground truth. Results: Phantom and clinical lesion segmentation have shown that the best segmentation results obtained by selecting the pixels with at least 70% SUVmax as foreground seeds and pixels up to 30% SUVmax as background seeds respectively. The mean Dice Similarity Coefficient of 94% ± 5% (83% ± 6%) and mean Hausdorff Distance of 1 (2) pixels have been obtained for phantom (clinical) study. Conclusion: The accurate results of random walk algorithm in PET image segmentation assure its application for radiation treatment planning and diagnosis.

60 APPLIED LIFE SCIENCES↗