Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

Robust Interpretation of Electrochemical Impedance Spectra Using Numerical Complex Analysis

Electrochemical Impedance Spectroscopy (EIS) is a noninvasive technique widely used for understanding charge transfer and charge transport processes in electrochemical systems and devices. Standard approaches for the interpretation of EIS data involve starting with a hypothetical circuit model for the physical processes in the device based on experience/intuition and then fitting the EIS data to this circuit model. This work explores a mathematical approach for extracting key characteristic features from EIS data by relying on fundamental principles of complex analysis. These characteristic features can suggest the presence of inductors and constant phase elements (nonideal capacitors) from impedance data and enable us to answer questions about the identifiability and nonuniqueness of equivalent circuit models. In certain scenarios such as models with only resistors and capacitors, we are able to enumerate all possible families of circuit models. Finally, we apply the mathematical framework presented here to real-world electrochemical systems and highlight results using impedance measurements from a lithium-ion battery coin cell.

charge transfer↗

Operating Stresses and Their Effects on Degradation of LSM-Based SOFC Cathodes

The performance of solid oxides fuel cells (SOFCs) with four different Mn excess of lanthanum strontium manganite (LSM) -based cathodes were examined under different temperatures (1,000 °C, 900 °C), current densities (0, 380, and 760 mA cm -2 ), and cathode atmospheres (p O 2 )=0.1,0.15,0.21) for durations ranging from 58 to 1,008 h. Each yttria-stabilized zirconia (YSZ) electrolyte-supported “button” cell had a porous Ni/YSZ composite anode and a porous LSM/YSZ composite cathode. The cells’ output voltage versus time were recorded and electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) measurements were performed every 24 hours. The total area specific resistance (ASR) was calculated from these measurements. The values of ASR from both EIS and LSV were comparable between each other but lower than that from durability test. Distribution of relaxation times (DRT) analysis was performed to investigate the electrochemical processes and their corresponding relaxation frequencies as well as their attributions to the total ASR. The series resistance and parallel resistance that obtained from the equivalent circuit fit of the Nyquist plot were higher at low temperature and low p O 2 regardless of LSM compositions. The area of the peaks derived from DRT analysis increased with time during individual tests. The microstructures of the tested cells were examined using scanning electron microscopy and energy-dispersive x-ray spectroscopy (SEM/EDS). Manganese oxide particles were observed near the cathode-electrolyte interface after prolonged (1,008 h) testing in air of a cell with LSM of 11% manganese excess, and after a short test (58 h) under low oxygen (p O 2 = 0.10) in a cell with LSM of 5% manganese excess. However, the role of MnOx in cell degradation is still unknown.

08 HYDROGEN↗

Qualification of 3-D Printed Mortar With Electrical Conductivity Measurements

Additive manufacturing (AM) or 3D printing of concrete allows for construction of arbitrary shape structures without a mold. Since reproducibility of 3D printed concrete is lower than that of conventional fabrication, each 3D printed structure should be monitored for proper curing. Conventional qualification of concrete is based on several tests, including destructive compressive strength measurements. Because a structure is 3-D printed layer-by-layer, the surfaces of AM concrete structures have significant surface roughness. This limits the applicability of conventional nondestructive testing methods. We investigated qualification of 3D printed mortar by monitoring curing with nondestructive electrical conductivity measurements. Bulk resistance of concrete was extracted from electrochemical impedance spectroscopy (EIS measurements made using custom flexible self-adhesive electrodes, which contour to rough surfaces. We show that bulk resistivity of concrete increases linearly with time. This allows for developing a calibration curve for compressive strength lookup from nondestructive electrical conductivity measurements. Conductivity measurements also allow for estimation of formation factor, which is an indicator of mortar permeability.

36 MATERIALS SCIENCE↗

Approaches to investigate the role of chelation in the corrosivity of biomass-derived oils

The need to provide the U.S. market with a renewable liquid fuel energy source from a non-food feedstock stream has gained considerable traction due to benefits such as improved energy efficiency, reduced environmental impacts, and enhanced national security. Practical achievement of these goals via biomass and bio-waste utilization involves production of liquid intermediates containing corrosive, reactive species like carboxylic acids, ketones, aldehydes, and hydroxyaldehydes. Such mixtures challenge materials of containment, processing, and transport. It is widely recognized that the smaller organic acids, such as acetic and formic, are corrosive and can remove protective surface oxides on alloys used in bio-oil processing infrastructure, and ketones can swell sealing polymers. However, literature shows, and findings herein confirm, larger carboxylic acids and bidentate alcohols are present. This highlights the potential for synergistic, detrimental effects of constituents in bio-oil corrosion, including direct reactivity of small acids compounded with the possibility of mobilization of protective metal oxide layers via chelation by larger acids and oxygenates. The question of whether species beyond small acids can significantly contribute to corrosion requires analytical approaches previously not applied to bio-oil corrosion studies and certainly not previously applied corroboratively. As such, this work introduces a combination of optical, mass spectral, and electrochemical impedance spectroscopies with an incubation approach to study metal mobilization, to facilitate elucidating chelation's role in bio-oil corrosive pathways. To enable systematic study of these oxygenates' material compatibility individually and in combination, a model matrix of bio-oil constituents was also developed based on identification of key components of real bio-oils.

09 BIOMASS FUELS↗

Manipulating meso-scale solvent structure from Pd nanoparticle deposits in deep eutectic solvents

Deep Eutectic Solvents (DESs) are complex solutions that present unique challenges compared to traditional electrolytes. Unlike most electrolytes and ionic liquids, DESs have delicate hydrogen bond networks that are responsible for their highly sensitive compositional dependence on the melting point. Prior work has demonstrated unique nanoscale structure both experimentally and theoretically that brings both challenges and opportunities to their adoption in traditional electrochemical processes. In this study, we use in-situ sample-rotated ultra-small angle X-ray scattering to resolve the near-interface solvent structure after electrodepositing Pd nanoparticles onto a glassy carbon electrode in choline chloride:urea and choline chloride:ethylene glycol DESs. Our results indicate that solvent structure can be observed on the meso-scale in the choline chloride:urea and choline chloride:ethylene glycol systems. Importantly, this extended solvent structure peaks at -0.5 V (vs. Ag/AgCl) and decreases slightly with higher overpotentials during Pd electrodeposition. Experimentally, the nature of this structure is more pronounced in the ethylene glycol system, as evidenced by both the X-ray scattering as well as the electrochemical impedance spectroscopy (EIS). Here, molecular dynamics simulations and dipolar orientation analysis reveal that chloride delocalization near the Pd interface and long-range interactions between the choline and each hydrogen bond donor are very different and qualitatively consistent with the experimental data. These results show how the long-range solvent-deposit interactions can be tuned by changing the hydrogen bond donor in the DES and the applied potential.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Voltage and temperature effects on low cobalt lithium-ion battery cathode degradation

Degradation of low cobalt lithium-ion cathodes was tested using a full factorial combination of upper cut-off voltage (4.0 V and 4.3 V vs. Li/Li + ) and operating temperature (25 °C and 60 °C). Half-cell batteries were analyzed with electrochemical and microstructural characterization methods. Electrochemical performance was assessed with galvanostatic cycling, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) supported by distribution of relaxation times (DRT) analysis. Electrode microstructure was characterized with scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray absorption near edge structure (XANES) imaging. Higher cut-off voltage cycling shows presence of NiO x formation, a low diffusivity rock-salt phase, in both CV and XRD data. XRD patterns confirmed that the rock-salt phase was beginning to form at the low cut-off voltage at high temperature, but in much lower intensity than at the high cut-off voltage. Higher temperature accelerates degradation processes at both voltages. Degradation factors at high temperature include NiO x formation, cathode material dissolution, and electrolyte decomposition. SEM analysis suggests that supporting phases may isolate and disconnect active material particles reducing capacity retention and battery life cycle. DRT analysis and XANES imaging show that both high temperature samples revealed a NiO x phase based on an increased diffusive impedance and a visible shift in the XANES spectra. The low cut-off voltage, high temperature sample showed a split peak and shift to lower energies indicating early formation of the NiO x phase. The diffusive impedance, which hinders intercalation and deintercalation, is driven by the formation of the NiO x phase. While primarily driven by cut-off voltage, elevated temperature also contributes to this degradation mechanism.

electrochemical impedance spectroscopy↗

Enhancing corrosion resistance of lightweight metal alloys through laser shock peening

In this study, we investigated the effects of laser shock peening (LSP) on the corrosion resistance of lightweight metal alloys, specifically AA6061 and AZ31. LSP was performed underwater, using a nanosecond pulse laser and without using a protective coating or layer on the workpiece. The corrosion behaviors of these alloys were analyzed through electrochemical tests, including open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization measurements. The results demonstrated that LSP significantly improved the polarization resistance, and higher laser power intensities led to increased corrosion resistance and reduced corrosion rates. This enhancement in anti-corrosion performance is attributed to the formation of a protective oxide layer on the surface, acting as a barrier against corrosion. In conclusion, the findings underscore the potential of laser surface treatment as a viable technique for enhancing the corrosion resistance of lightweight metal alloys.

36 MATERIALS SCIENCE↗

Degradation and recovery of solid oxide fuel cell performance by control of cathode surface acidity: Case study – Impact of Cr followed by Ca infiltration

Solid oxide fuel cells (SOFC) have attracted attention as clean and efficient energy conversion devices with low emissions. However, several degradation mechanisms limit the electrochemical performance of current SOFCs, with cathode degradation due to Cr-poisoning from metal interconnects particularly problematic. The acidity/basicity of binary additives has been found to be a sensitive descriptor of the oxygen exchange kinetics, indicating that acidic Cr-species/basic Ca-species can be expected to deactivate/activate the cathode surface, respectively. Inspired by recent advances, the feasibility of relative acidity as a tool for reviving degraded SOFCs is demonstrated by neutralizing Cr-poisoned SOFCs by subsequent serial infiltration of Ca-species. Furthermore, a model mixed ionic and electronic conducting oxide, Pr 0.1 Ce 0.9 O 2-δ (PCO), is selected as the cathode material. Area-specific resistances (ASR) of symmetric cells obtained by electrochemical impedance spectroscopy show that Cr-infiltration results in a seven-fold increase in ASR, while subsequent infiltration of Ca-species leads to complete recovery. Performance degradation and recovery are attributed to depressed/enhanced redox properties at the PCO surface, as supported by XPS analysis. Experiments using anode-supported fuel cells show a reduction in peak power density by 26% upon Cr-infiltration, reversed following Ca-infiltration, after which no degradation is observed during subsequent operation for 100 h.

(Pr,Ce)O2-δ↗

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗

Tuning Surface Acidity of Mixed Conducting Electrodes: Recovery of Si‐Induced Degradation of Oxygen Exchange Rate and Area Specific Resistance

Abstract Metal oxides are an important class of functional materials, and for many applications, ranging from solid oxide fuel/electrolysis cells, oxygen permeation membranes, and oxygen storage materials to gas sensors (semiconducting and electrolytic) and catalysts, the interaction between the surface and oxygen in the gas phase is central. Ubiquitous Si‐impurities are known to impede this interaction, commonly attributed to the formation of glassy blocking layers on the surface. Here, the surface oxygen exchange coefficient ( k chem ) is examined for Pr 0.1 Ce 0.9 O 2‐δ (PCO), a model mixed ionic electronic conductor, via electrical conductivity relaxation measurements, and the area‐specific resistance (ASR) by electrochemical impedance spectroscopy. It is demonstrated that even low silica levels, introduced by infiltration, depress k chem by a factor 4000, while the ASR increases 40‐fold and we attribute this to its acidity relative to that of PCO. The ability to fully regenerate the poisoned surface by the subsequent addition of basic Ca‐ or Li‐species is further shown. This ability to not only recover Si‐poisoned surfaces by tuning the relative surface acidity of an oxide surface, but subsequently outperform the pre‐poisoned response, promises to extend the operating life of materials and devices for which the catalytic oxygen/solid interface reaction is central.

30 DIRECT ENERGY CONVERSION↗

Impact of Anode to Cathode Crossover in Lithium‐metal Batteries With High‐Nickel Cathodes

The advancement of high-energy-density lithium-metal batteries (LMBs) is hindered by the chemical instability of both lithium-metal anode and high-nickel layered oxide cathodes. While cathode-to-anode crossover is well-documented, the reverse process of anode-to-cathode crossover remains underexplored. Here, we systematically investigate such crossovers and the degradation pathway in pouch cells with a localized high-concentration electrolyte, comparing NMC622, NMC811, and NMC90 cathodes paired with lithium-metal and graphite anodes. Despite delivering higher initial capacities, LMBs exhibit faster capacity fade under long-term cycling at 45 °C. To isolate cathode-side degradation, galvanostatic electrochemical impedance spectroscopy (GEIS) measurements of cycled cathodes paired with delithiated lithium iron phosphate (LFP) counter electrodes reveal significantly higher charge-transfer resistance in cathodes cycled with lithium-metal. Surface characterization via X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) reveals greater electrolyte decomposition on cathodes cycled with lithium metal, leading to thicker, more organic-rich cathode–electrolyte interphases (CEIs), consistent with the elevated charge-transfer resistance observed in GEIS measurements. Notably, NMC90 shows the most pronounced CEI thickening, linking higher cathode surface reactivity to greater susceptibility to anode-to-cathode crossover. This work presents compelling evidence of crosstalk degradation originating from lithium-metal anodes and underscores the importance of cross-interface stability for the design of durable LMBs.

25 ENERGY STORAGE↗

The Influence of Cr-Additives on the Polarization Resistance of Praseodymium-Doped Ceria Cathodes for Solid Oxide Fuel Cells

While Cr poisoning of the oxygen reduction reaction (ORR) at SOFC cathodes is widely agreed to involve deactivation of oxygen exchange sites, the degradation mechanism remains ambiguous. Here, we selected an alternative cathode material Pr 0.1 Ce 0.9 O 2− δ , free of Sr segregation, to systematically investigate the effect of Cr-induced degradation in ORR. We expand on our previous studies in which the acidity/basicity of binary additives was found to be a strong indicator of the rate of oxygen surface exchange, by electrochemically investigating the ORR activity of the PCO cathode by impedance spectroscopy. Serial infiltration with acidic Cr-based oxides was found to degrade ORR activity as reflected in a 20-fold increase in area specific resistance (ASR) without corresponding changes in activation energy, with the opposite trend obtained with Ca-based oxides. Detected changes in total capacitance, attributed to changes in surface capacitance, also suggest depressed/enhanced PCO surface redox behavior with Cr/Ca-based infiltrants. Taken together, these results point to a more universal source of ORR poisoning/activation, based on acidity/basicity, rather than physical blocking of active sites. With this improved understanding, one can expect progress to be made in the coming years in optimizing means for protecting catalytic surfaces from degradation and/or improving their performance.

25 ENERGY STORAGE↗

Transforming an Ionic Conductor into an Electronic Conductor via Crystallization: In Situ Evolution of Transference Numbers and Structure in (La,Sr)(Ga,Fe)O 3–x Perovskite Thin Films

Mixed-conducting perovskites are workhorse electrochemically active materials, but typical high-temperature processing compromises their catalytic activity and chemo-mechanical integrity. Low-temperature pulsed laser deposition of amorphous films plus mild thermal annealing is an emerging route to form homogeneous mixed conductors with exceptional catalytic activity, but little is known about the evolution of the oxide-ion transport and transference numbers during crystallization. Here the coupled evolution of ionic and electronic transport behavior and structure in room-temperature-grown amorphous (La,Sr)(Ga,Fe)O 3-x films as they crystallize is explored. In situ ac-impedance spectroscopy with and without blocking electrodes, simultaneous capturing-synchrotron-grazing-incidence X-ray diffraction, dc polarization, transmission electron microscopy, and molecular dynamics simulations to evaluate isothermal and non-isothermal crystallization effects and the role of grain boundaries on transference numbers is combined. Ionic conductivity increases by ≈2 orders of magnitude during crystallization, with even larger increases in electronic conductivity. Consequently, as crystallinity increases, LSGF transitions from a predominantly ionic conductor to a predominantly electronic conductor. The roles of evolving lattice structural order, microstructure, and defect chemistry are examined. Grain boundaries appear relatively nonblocking electronically but significantly blocking ionically. The results demonstrate that ionic transference numbers can be tailored over a wide range by tuning crystallinity and microstructure without having to change the cation composition.

36 MATERIALS SCIENCE↗

Atomic layer deposited aluminum nitride for interface protection of lithium germanium thiophosphate solid electrolytes

Lithium germanium thiophosphate (LGPS) is an attractive solid-state electrolyte material due to its exceptionally high ionic conductivity (~1.2 × 10 –2 S cm –1 ), comparable to many organic liquid electrolytes commonly used in batteries. Despite the high conductivity of LGPS, the susceptibility of LGPS to deleterious degradation reactions has impeded its commercial adoption into solid-state batteries. In particular, the poor voltage stability of LGPS with high-voltage cathode or lithium metal potentials often results in dramatically increasing cell impedance during galvanic cycling. Here, we use aluminum nitride (AlN) as a protection layer for Li metal anode, applied directly to the LGPS at 250 °C using plasma-enhanced atomic layer deposition, to enhance cell performance by preventing LGPS-Li metal reactions. We compare the surface chemistry and electrochemical cycling performance of atomic layer-deposited AlN grown using both plasma N 2 and NH 3 precursors. Galvanostatic cycling and electrochemical impedance spectroscopy show that AlN-coated LGPS cells perform better than bare LGPS cells in contact with Li metal anodes, with the AlN able to improve cycling longevity by over a factor of 3 in certain cases. Finally, we utilize x-ray photoelectron spectroscopy (XPS) line scans to highlight the slow room-temperature reactivity between AlN and evaporated lithium metal, and a computational model is built to aid further XPS analysis.

25 ENERGY STORAGE↗

Lewis Acid Site Engineering in Chromite Spinels Orchestrated Surface Reconstruction and Surpasses RuO 2 in Oxygen Evolution

Atomic-scale engineering of chromite spinels featuring redox-active tetrahedral A-sites and strong Cr–O covalency offers a promising route to superior platinum-group-metal-free oxygen evolution reaction (OER) catalysts. However, comprehensive studies addressing how cation substitution influences surface chemistry and governs OER activity and durability in chromite spinels remain limited. Here, in this work, a systematic investigation of the multicationic chromite series Ni x Fe y Cr 3−x−y O 4 is presented, identifying composition-dependent Lewis acidity as a descriptor of superior OER performance. It is further demonstrated that tuning surface acidity directly controls dynamic reconstruction processes and lattice-oxygen participation during spinel-based electrocatalysis. Following activation, the optimized Ni 0.8 Fe 0.3 Cr 1.9 O 4 catalyst delivers a current density of 10 mA cm −2 at an overpotential of 235 mV, surpassing RuO 2 , with excellent long-term stability. Integrating microscopic and spectroscopic analysis with operando impedance spectroscopy, it shows that activation generates an oxyhydroxide overlayer and reveals a previously unrecognized link between surface Lewis acidity and the growth kinetics and activity of these shells. Density functional theory calculations indicate that Fe incorporation at octahedral sites raises the O 2p-band center and lowers oxygen-vacancy formation energy, promoting lattice-oxygen activation and triggering reconstruction, yielding enhanced OER. This work integrates cation-driven surface-acidity modulation, acidity-governed reconstruction, and OER activity enhancement into a unified predictive framework for designing earth-abundant spinel-based catalysts.

operando impedance spectroscopy↗