Search NASA⌕ Search

SEARCH · Search NASA

Results for “induction generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optimization of the parameters of plasma liners with zero-dimensional models

The efficiency of conversion of the energy stored in the capacitor bank of a high-current pulse generator into the kinetic energy of an imploding plasma liner is analyzed. The analysis is performed by using a model consisting of LC circuit equations and equations of motion of a cylindrical shell. It is shown that efficient energy conversion can be attained only with a low-inductance generator. The mode of an 'ideal' load is considered where the load current at the final stage of implosion is close to zero. The advantages of this mode are, first, high efficiency of energy conversion (80%) and, second, improved stability of the shell implosion. In addition, for inertial confinement fusion realized by the scheme of a Z pinch dynamic hohlraum, not one but several fusion targets can be placed in the cavity on the pinch axis due to the large length of the liner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust Output Feedback Control Design for Inertia Emulation by Wind Turbine Generators

Wind generation has gained widespread use as a renewable energy source. Most wind turbines and other renewables connected to the grid through converters result in a reduction in the natural inertial response to grid frequency changes. The doubly-fed induction generator (DFIG) can be controlled to compensate for this reduction and, in fact, provide faster response than traditional synchronous machines. This paper proposes to design observer based output feedback linear quadratic regulator (LQR) and H control laws to realize the inertia emulation function and deliver fast frequency support. Furthermore, the aim is to track the reference speed by a diesel synchronous generator (DSG) in order to reach the desired inertia. The control signal is computed based on a reduced order model using the balanced truncation technique. A comparison with selective modal analysis (SMA) and balanced truncation model reduction techniques is presented. Comprehensive results show the effective emulation of synthetic inertia by implementing the control laws on a nonlinear three- phase diesel-wind system. The proposed technique is analyzed for different short circuit ratio (SCR) scenarios.

17 WIND ENERGY↗

Short-Term Forecasting of Inertial Response from a Wind Power Plant

The total inertia stored in all rotating masses (synchronous generators, induction motors, etc.) connected to a power system grid is an essential force that keeps the system stable after disturbances. Power systems have been experiencing reduced inertia during the past few decades [1]. This trend will continue as the level of renewable generation (e.g., wind and solar) increases. Wind power plants (WPPs) and other renewable power plants with power electronic interfaces are capable of delivering frequency response (both droop and/or inertial response) by a control action; thus, the reduction in available online inertia can be compensated by designing the plant control to include frequency response. The source of energy to be delivered as inertial response is determined by the type of generation (wind, photovoltaic, concentrating solar power, etc.) and the control strategy chosen. The importance of providing ancillary services to ensure frequency control within a power system is evidenced from many recent publications with different perspectives (manufacturer, system operator, regulator, etc.) [2]-[6]. This paper is intended to provide operators with a method for the real-time assessment of the available inertia of a WPP. This is critical to managing power system stability and the reserve margin. In many states, modern WPPs are required to provide ancillary services (e.g., frequency regulation via governor response and inertial response) to the grid. This paper describes the method of estimating the available inertia and the profile of the forecasted response from a WPP.

17 WIND ENERGY↗

Stable Short-Term Frequency Support Using Adaptive Gains for a DFIG-Based Wind Power Plant

For the fixed-gain inertial control of wind power plants (WPPs), a large gain setting provides a large contribution to supporting system frequency control, but it may cause over-deceleration for a wind turbine generator that has a small amount of kinetic energy (KE). Further, if the wind speed decreases during inertial control, even a small gain may cause over-deceleration. Here this paper proposes a stable inertial control scheme using adaptive gains for a doubly fed induction generator (DFIG)-based WPP. The scheme aims to improve the frequency nadir (FN) while ensuring stable operation of all DFIGs, particularly when the wind speed decreases during inertial control. In this scheme, adaptive gains are set to be proportional to the KE stored in DFIGs, which is spatially and temporally dependent. To improve the FN, upon detecting an event, large gains are set to be proportional to the KE of DFIGs; to ensure stable operation, the gains decrease with the declining KE. The simulation results demonstrate that the scheme improves the FN while ensuring stable operation of all DFIGs in various wind and system conditions. Further, it prevents over-deceleration even when the wind speed decreases during inertial control.

17 WIND ENERGY↗

Adaptive Gain-based Stable Power Smoothing of a DFIG

In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. Here, the simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP

Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims to improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evolution of the organizer and the chordate body plan

The discovery of the organizer by Spemann and Mangold in 1924 raised two kinds of questions: those about the means of patterning the chordate body axis and those about the mechanisms of cell determination by induction. Some researchers, stressing the second, have suggested over the years that the organizer is poorly named and doesn't really organize because inducers act permissively, because they are not unique to the organizer, and because multipotent responsive cells develop complex local differentiations under artificial conditions. Furthermore, with the discovery of meso-endoderm induction in 1969, the possibility arose that this earlier induction generates as much organization as, or more than, does the organizer itself. Evidence is summarized in this article that the organizer does fulfill its title with regard to pattern formation: it adds greatly to embryonic organization by providing information about time, place, scale, and orientation for development by nearby members of the large multipotent competence groups surrounding the organizer. Embryos having smaller or larger organizers due to experimental intervention develop defective axial organization. Without an organizer the embryo develops no body axis and none of the four chordate characters: the notochord, gill slits, dorsal hollow nerve chord, and post-anal tail. For normal axis formation, the organizer's tripartite organization is needed. Each part differs in inducers, morphogenesis, and self-differentiation. The organizer is a trait of development of all members of the chordate phylum. In comparison to hemichordates, which constitute a phylum with some similarities to chordates, the chordamesoderm part is unique to the chordate organizer (the trunk-tail organizer). Its convergent extension displaces the gastrula posterior pole from alignment with the animal-vegetal axis and generates a new anteroposterior axis orthogonal to this old one. Once it has extended to full length, its signaling modifies the dorsoventral dimension. This addition to the organizer is seen as a major event in chordate evolution, bringing body organization beyond that achieved by oocyte organization and meso-endoderm induction in other groups.

Non-NASA Center↗

Large-Signal Impedance-Based Modeling and Mitigation of Resonance of Converter-Grid Systems

Large-signal impedance of grid-connected converters can be used to predict resonance-generated distortions in converter-grid systems. Note that the large-signal impedance of a network represents its impedance response for different magnitudes of perturbation injected at its terminals. This paper presents large-signal impedance-based modeling and mitigation of resonance of grid-connected voltage source converters (VSCs). Challenges of large-signal modeling because of the inapplicability of the small-signal approximation are addressed by leveraging the dominating influence of hard nonlinearities (such as pulse-width modulation saturation and limiters) over soft nonlinearities (such as Park's transformations and PLL) in shaping the large-signal behavior of the converter. The paper develops large-signal gains of hard nonlinearities using different types of describing functions. The paper shows that the large-signal impedance of a VSC can be shaped to reduce resonance-generated distortions by inserting limiters in the control system of the VSC. Developed large-signal impedance models are validated using numerical simulations of a VSC with dq current control and PLL. In conclusion, a large-signal impedance measurements of a commercial 1 MW VSC-based inverter and a medium-voltage doubly-fed induction generator with approximate 4 MW rating are presented to experimentally demonstrate the influence of the injected perturbation magnitude on the impedance response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 15kWe (nominal) solar thermal electric power conversion concept definition study: Steam Rankine reheat reciprocator system

An evaluation was made of the potential of a steam Rankine reheat reciprocator engine to operate at high efficiency in a point-focusing distributed receiver solar thermal-electric power system. The scope of the study included the engine system and electric generator; not included was the solar collector/mirror or the steam generator/receiver. A parametric analysis of steam conditions was completed leading to the selection of 973 K 12.1 MPa as the steam temperature/pressure for a conceptual design. A conceptual design was completed for a two cylinder/ opposed engine operating at 1800 rpm directly coupled to a commercially available induction generator. A unique part of the expander design is the use of carbon/graphite piston rings to eliminate the need for using oil as an upper cylinder lubricant. The evaluation included a system weight estimate of 230 kg at the mirror focal point with the condenser mounted separately on the ground. The estimated cost of the overall system is $1932 or $90/kW for the maximum 26 kW output.

Fuller, H.↗

High-harmonic Fast Wave Heating and Current Drive Results for Deuterium H-mode Plasmas in the National Spherical Torus Experiment

A critical research goal for the spherical torus (ST) program is to initiate, ramp-up, and sustain a discharge without using the central solenoid. Simulations of non-solenoidal plasma scenarios in the National Spherical Torus Experiment (NSTX) [1] predict that high-harmonic fast wave (HHFW) heating and current drive (CD) [2] can play an important roll in enabling fully non-inductive (fNI {approx} 1) ST operation. The NSTX fNI {approx} 1 strategy requires 5-6 MW of HHFW power (PRF) to be coupled into a non-inductively generated discharge [3] with a plasma current, Ip {approx} 250-350 kA, driving the plasma into an HHFW H-mode with Ip {approx} 500 kA, a level where 90 keV deuterium neutral beam injection (NBI) can heat the plasma and provide additional CD. The initial approach on NSTX has been to heat Ip {approx} 300 kA, inductively heated, deuterium plasmas with CD phased HHFW power [2], in order to drive the plasma into an H-mode with fNI {approx} 1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planar Transformer With Asymmetric Integrated Leakage Inductance Using Horizontal Air Gap

This article presents a novel planar-based transformer winding and core structure with controllable leakage inductance generation for integrated magnetics applications. As a result of limitations in integrated magnetics from the literature, a new approach is proposed utilizing semi-interleaved windings and controllable leakage via a leakage flux core leg featuring a horizontal air gap. Here, the proposed transformer design is analyzed via detailed reluctance modeling to determine closed-form equations for the magnetizing and asymmetrically distributed leakage inductances. Next, a genetic-algorithm-based multiobjective design optimization problem is developed, seeking to minimize the core and winding losses of the proposed transformer subject to a set of parametric and geometric constraints in a dc-ac dual-active-bridge topology for microinverter applications. The optimization was extended to include other integrated magnetic structures from the literature, where it is determined that the proposed transformer is superior from the perspectives of efficiency, footprint area, and parasitic capacitance. Based on the results of the optimization analysis, two designs with theoretical transformer California Energy Commission (CEC) efficiency drops (i.e., CEC efficiency reduction specifically due to the transformer loss mechanisms) of 1.19% and 0.83% were fabricated and evaluated for electrical and thermal performance in the proposed 40 V, 400 W microinverter.

42 ENGINEERING↗

Preliminary design of an advanced Stirling system for terrestrial solar energy conversion

A preliminary design was generated for an advanced Stirling conversion system (ASCS) that will be capable of delivering about 25 kW of electric power to an electric utility grid. Stirling engines are being evaluated for terrestrial solar applications. A two-year task to complete detailed design, fabrication, assembly and testing of an ASCS prototype began in April, 1990. The ASCS is designed to deliver maximum power per year over a range of solar inputs with a design life of 30 years (60,000 h). The ACSC has a long-term cost goal of about $450 per kilowatt, exclusive of the 11-m parabolic dish concentrator. The proposed system includes a Stirling engine with high-pressure hydraulic output, coupled with a bent axis variable displacement hydraulic motor and a rotary induction generator. The major thrusts of the preliminary design are described, including material selection for the hot-end components, heat transport system (reflux pool boiler) design, system thermal response, improved manufacturability, FMECA/FTA analysis, updated manufacturing cost estimate, and predicted system performance.

White, M. A.↗

Distributed Cooperative Control of Wind Farms with On-Site Battery Energy Storage Systems

This chapter studies the output power regulation in wind farms consisting of doubly-fed induction generator wind turbines, one of the most popular generator configurations in modern multi-MW wind industry, equipped with on-site battery energy storage systems. Traditionally, wind farms were operated as standalone units or were equipped with a central, large-scale, energy storage system. In fact, most of the existing control designs for hybrid wind-storage applications are centralized, where the central unit collects the measured data from all wind turbines and storage systems (if they exist) and compares with the load demand to generate the reference power for each wind turbine controller. Those centralized setups or control structures do not fully exploit the flexibility and locality of the on-site energy storage systems in a wind farm. Moreover, the storage functionality is lost if the central storage system is broken down, while in a distributed architecture, a failure only affects individual on-site storage systems and the others will still operate. Therefore, on-site storage systems and distributed control designs need to be developed for wind farms to provide regulation services for the grid. An approach to tackle that challenge will be presented in this chapter.

17 WIND ENERGY↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improving DFIG performance under fault scenarios through evolutionary reinforcement learning based control

The double-fed induction generator (DFIG) usually experiences high rotor current and DC capacitor link voltage during system fault events. In this paper, a novel data-driven approach is proposed to enhance the DFIG performance under fault scenarios. An advanced reinforcement learning (RL) algorithm called guided surrogate-gradient-based evolution strategy (GSES) is used to control the DFIG power and capacitor DClink voltage by adjusting the optional reference signals. This controller is able to prevent the rotor of DFIG from overcurrent risk and maintain the grid-connected operation. The proposed GSES-based control algorithm was evaluated through simulations on a 3.6-MW DFIG in PSCAD/EMTDC software. Results have validated the effectiveness of the proposed GSESbased control algorithm in improving the DFIG performance under fault scenarios.

42 ENGINEERING↗

OPEN-CODE, REAL-TIME EMULATION TESTBED OF GRID-CONNECTED TYPE-3 WIND TURBINE SYSTEM WITH HARDWARE VALIDATION

This paper presents the design and development of an open-code Type-3 wind turbine virtual-testbed for real-time simulations. The proposed testbed includes the bare code for all the models required to emulate a Type-3 wind turbine system: the Doubly-Fed Induction Generator (DFIG) dynamic model, single-mass drive train, wind turbine system, and average model of the back to back power. This testbed can be executed in PC-layer for offline simulations or can be executed in real-time on the National Instruments (NI)-CompactRIO (cRIO) platform. The discrete-time models are implemented on the Field Programmable Gate Array (FPGA), using LabVIEW, and validated against a physical hardware setup. The emulated stator and rotor currents and DC-link voltage are compared against physical measurements creating a validated platform independent from third-party models and suitable for applications in real-time. The proposed testbed is intended to be available to researchers, wind turbine manufacturers, and utility companies to perform tests using a validated platform to verify proposed control designs of DFIG wind turbines.

Ferrari Maglia, Max↗

Dynamic State Estimation and Parameter Calibration of DFIG based on Ensemble Kalman Filter

With the growing interest in the application of wind energy, doubly fed induction generator (DFIG) plays an essential role in the industry nowadays. To deal with the increasing stochastic variations introduced by intermittent wind resource and responsive loads, dynamic state estimation (DSE) are introduced in any power system associated with DFIGs. However, sometimes this dynamic analysis canould not work because the parameters of DFIGs are not accurate enough. To solve the problem, an ensemble Kalman filter (EnKF) method is proposed for the state estimation and parameter calibration tasks. In this paper, a DFIG is modeled and implemented with the EnKF method. Sensitivity analysis is demonstrated regarding the measurement noise, initial state errors and parameter errors. The results indicate this EnKF method has a robust performance on the state estimation and parameter calibration of DFIGs.

Fan, Rui↗

The Integrated Reference Region Analysis for Parallel DFIGs’ Interfacing Inductors

Although the traditional design of doubly-fed induction generators (DFIGs)’ interfacing inductors consider the peak ripple of the grid-side converter (GSC)’s output current, it does not consider the inductors’ impact on DFIGs’ smallsignal stability. Located in series between the GSC and the stator, the inappropriate selection of the interfacing inductor can easily result to system instability. Therefore, this paper first proposes the integrated reference region analysis for small wind farm's interfacing inductors to improve the traditional design method. Firstly, a new detailed parallel DFIGs’ smallsignal model that considers output currents’ coupling is built in d-q coordinate system with state-space approach. The model focuses on representing the operating states of parallel DFIGs in wind farm. Secondly, the linearized state-space matrix of parallel DFIGs is decomposed into nominal-value matrix and location matrix. Considering the traditional design requirements, the integrated reference region for interfacing inductor is proposed through spectral radius and bialternate matrix sum (BMS). Furthermore, it can provide better guidance for parameter selecting and stabilization method researches. Finally, the simulation and experimental results show that the proposed integrated reference region for parallel DFIGs’ interfacing inductors is accurate and instructive.

47 OTHER INSTRUMENTATION↗