Search NASA⌕ Search

SEARCH · Search NASA

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Mercury control challenge for industrial boiler MACT affected facilities

An industrial coal-fired boiler facility conducted a test program to evaluate the effectiveness of sorbent injection on mercury removal ahead of a fabric filter with an inlet flue gas temperature of 375{sup o}F. The results of the sorbent injection testing are essentially inconclusive relative to providing the facility with enough data upon which to base the design and implementation of permanent sorbent injection system(s). The mercury removal performance of the sorbents was significantly less than expected. The data suggests that 50 percent mercury removal across a baghouse with flue gas temperatures at or above 375{sup o}F and containing moderate levels of SO{sub 3} may be very difficult to achieve with activated carbon sorbent injection alone. The challenge many coal-fired industrial facilities may face is the implementation of additional measures beyond sorbent injection to achieve high levels of mercury removal that will likely be required by the upcoming new Industrial Boiler MACT rule. To counter the negative effects of high flue gas temperature on mercury removal with sorbents, it may be necessary to retrofit additional boiler heat transfer surface or spray cooling of the flue gas upstream of the baghouse. Furthermore, to counter the negative effect of moderate or high SO{sub 3} levels in the flue gas on mercury removal, it may be necessary to also inject sorbents, such as trona or hydrated lime, to reduce the SO{sub 3} concentrations in the flue gas. 2 refs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Wister, CA Downhole and Seismic Data

This submission contains Downhole geophysical logs associated with Wister, CA Wells 12-27 and 85-20. The logs include Spontaneous Potential (SP), HILT Caliper (HCAL), Gamma Ray (GR), Array Induction (AIT), and Neutron Porosity (NPOR) data. Also included are a well log, Injection Test, Pressure Temperature Spinner log, shut in temperature survey, a final well schematic, and files about the well's location and drilling history. This submission also contains data from a three-dimensional (3D) multi-component (3C) seismic reflection survey on the Wister Geothermal prospect area in the northern portion of the Imperial Valley, California. The Wister seismic survey area was 13.2 square miles. (Resistivity image logs (Schlumberger FMI) in 85-20 indicate that maximum horizontal stress (Shmax) is oriented NNE but that open fractures are oriented suboptimally).

12-27↗

Characterization of laboratory-scale hydraulic fracturing for EGS

To investigate the impact of reservoir stimulation by hydraulic fracturing, a series of advanced lab-scale block tests were conducted with multiple measurement methods to characterize the fracture and to assess the operation and the performance of an enhanced or engineered geothermal system (EGS). The stimulation test samples were 330-mm cubic blocks of Sierra White granite with one injection well and four producers drilled into it. Acoustic emissions generated during the fracture initiation and propagation were monitored with twenty AE sensors mounted on all sides of the block to help characterize the fracture initiation and propagation process. The recorded AE signals were analyzed to obtain the event location and the failure mechanism. The localized AE events shows that due to the low viscosity of the fracturing fluid (water), the fracture propagated rapidly and took only about 1.4 s to reach near the block surface. During the fracturing phase, about 47 percent of the events were determined to be shear/mixed mode failure events, 28 percent tensile failure events, and 25 percent compressional failure events. Just after the simulation, a step-rate (constant flowrate) injection test was carried out to investigate the reservoir injectivity enhancement. During this phase additional compressional failure events were observed and the percentages of tensile failure and shear/mixed mode failure decreased. The dramatic increase of the injection rate with small increments of the injection pressure demonstrates the nonlinear response of the fracture to effective normal stress variation with much higher fracture opening increase during the low effective normal stress interval. Hydraulic fracturing tests under different stress levels show that more AE hits/events are recorded when the rock block is under higher applied stress. The reconstructed 3D fracture geometry shows good agreement with the AE monitoring results. After fracturing, a tracer test was carried out and the fracture aperture was estimated to be around 139 μm. The tracer recovery curve shows two linear portions of the tracer tail on a semi-log plot similar to that observed in some field data and predicted by numerical modeling. Laser scanning of the fracture surfaces indicates that the induced fracture has a rough surface with a joint roughness coefficient (JRC) of 12.98 and tortuosity of 1.10, both of which are slightly larger than that from the Brazilian test fracture on the same rock. The thin section and SEM observations show that the fracture follows the weak boundaries between the Quartz and Albite grains or the weak beddings in the grains.

58 GEOSCIENCES↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Simulation of dilatancy-controlled gas migration processes in saturated bentonite using a coupled multiphase flow and elastoplastic H 2 M model

Dilatancy-controlled gas flow in preferential pathways plays a key role in the safety analysis of radioactive waste repositories. This is particularly the case for bentonite, an often-preferred barrier material. Gas flow in preferential pathways is characterized by localization and spontaneous behavior, which is challenging to simulate in numerical models due to strong hydro-mechanical coupling. To analyze a laboratory experiment in the framework of the DECOVALEX-2023 project, this study introduced a new approach of combining continuous modelling methods with spatial material properties derived from material heterogeneities and experimental observations. The proposed model utilized hydro-mechanical spatial distributions, namely Young's modulus and gas entry pressure, and elastoplasticity combined with a linear swelling model. A conceptual strain-dependent permeability approach simulated dilatancy-controlled gas flow based on hydro-mechanical coupling. To test the effectiveness of the presented approach, a gas injection test in a compacted, saturated bentonite sample was simulated using the open-source code OpenGeoSys 5.8 and compared with experimental observations. The presented methodology is capable of simulating localized gas flow in preferential pathways. The spatial distributions of Young's modulus and gas entry pressure affect the swelling pressure, relative permeability and, in combination with the strain-dependent permeability model, also the intrinsic permeability.

42 ENGINEERING↗

Fast Fault Injection and Sensitivity Analysis for Collective Communications, In: 2015 IEEE International Conference on Cluster Computing

The collective communication operations, which are widely used in parallel applications for global communication and synchronization are critical for application's performance and scalability. However, how faulty collective communications impact the application and how errors propagate between the application processes is largely unexplored. One of the critical reasons for this situation is the lack of fast evaluation method to investigate the impacts of faulty collective operations. The traditional random fault injection methods relying on a large amount of fault injection tests to ensure statistical significance require a significant amount of resources and time. These methods result in prohibitive evaluation cost when applied to the collectives. In this paper, we introduce a novel tool named Fast Fault Injection and Sensitivity Analysis Tool (FastFIT) to conduct fast fault injection and characterize the application sensitivity to faulty collectives. The tool achieves fast exploration by reducing the exploration space and predicting the application sensitivity using Machine Learning (ML) techniques. A basis for these techniques are implicit correlations between MPI semantics, application context, critical application features, and application responses to faulty collective communications. The experimental results show that our approach reduces the fault injection points and tests by 97% for representative benchmarks (NAS Parallel Benchmarks (NPB)) and a realistic application (Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS)) on a production supercomputer. Further, we statistically generalize the application sensitivity to faulty collective communications for these workloads, and present correlation between application features and the sensitivity.

Computer Science↗

Insight from simulations of single-well injection-withdrawal tracer tests on simple and complex fractures

The single-well injection withdrawal (SWIW) test, a tracer test utilizing only one well, is proposed as a useful contribution to site characterization of fractured rock, as well as providing parameters relevant to tracer diffusion and sorption. The usual conceptual model of flow and solute transport through fractured rock with low matrix permeability involves solute advection and dispersion through a fracture network coupled with diffusion and sorption into the surrounding rock matrix. Unlike two-well tracer tests, results of SWIW tests are ideally independent of advective heterogeneity, channeling and flow dimension, and, instead, focus on diffusive and sorptive characteristics of tracer (solute) transport. Thus, they can be used specifically to study such characteristics and evaluate the diffusive parameters associated with tracer transport through fractured media. We conduct simulations of SWIW tests on simple and complex fracture models, the latter being defined as having two subfractures with altered rock blocks in between and gouge material in their apertures. Using parameters from the Aspo site in Sweden, we calculate and study SWIW tracer breakthrough curves (BTCs) from a test involving four days of injection and then withdrawal. By examining the peak concentration C{sub pk} of the SWIW BTCs for a variety of parameters, we confirm that C{sub pk} is largely insensitive to the fracture advective flow properties, in particular to permeability heterogeneity over the fracture plane or to subdividing the flow into two subfractures in the third dimension orthogonal to the fracture plane. The peak arrival time t{sub pk} is not a function of fracture or rock properties, but is controlled by the time schedule of the SWIW test. The study shows that the SWIW test is useful for the study of tracer diffusion-sorption processes, including the effect of the so-called flow-wetted surface (FWS) of the fracture. Calculations with schematic models with different FWS values are conducted and the possibility of direct in situ measurement of FWS with SWIW tests is demonstrated.

54 ENVIRONMENTAL SCIENCES↗

Advanced information processing system: Fault injection study and results

The objective of the AIPS program is to achieve a validated fault tolerant distributed computer system. The goals of the AIPS fault injection study were: (1) to present the fault injection study components addressing the AIPS validation objective; (2) to obtain feedback for fault removal from the design implementation; (3) to obtain statistical data regarding fault detection, isolation, and reconfiguration responses; and (4) to obtain data regarding the effects of faults on system performance. The parameters are described that must be varied to create a comprehensive set of fault injection tests, the subset of test cases selected, the test case measurements, and the test case execution. Both pin level hardware faults using a hardware fault injector and software injected memory mutations were used to test the system. An overview is provided of the hardware fault injector and the associated software used to carry out the experiments. Detailed specifications are given of fault and test results for the I/O Network and the AIPS Fault Tolerant Processor, respectively. The results are summarized and conclusions are given.

Burkhardt, Laura F.↗

Advanced Techniques for Power System Identification from Measured Data

Time-synchronized measurements provide rich information for estimating a power-system's electromechanical modal properties via advanced signal processing. This information is becoming critical for the improved operational reliability of interconnected grids. A given mode's properties are described by its frequency, damping, and shape. Modal frequencies and damping are useful indicators of power-system stress, usually declining with increased load or reduced grid capacity. Mode shape provides critical information for operational control actions. This project investigated many advanced techniques for power system identification from measured data focusing on mode frequency and damping ratio estimation. Investigators from the three universities coordinated their effort with Pacific Northwest National Laboratory (PNNL). Significant progress was made on developing appropriate techniques for system identification with confidence intervals and testing those techniques on field measured data and through simulation. Experimental data from the western area power system was provided by PNNL and Bonneville Power Administration (BPA) for both ambient conditions and for signal injection tests. Three large-scale tests were conducted for the western area in 2005 and 2006. Measured field PMU (Phasor Measurement Unit) data was provided to the three universities. A 19-machine simulation model was enhanced for testing the system identification algorithms. Extensive simulations were run with this model to test the performance of the algorithms. University of Wyoming researchers participated in four primary activities: (1) Block and adaptive processing techniques for mode estimation from ambient signals and probing signals, (2) confidence interval estimation, (3) probing signal design and injection method analysis, and (4) performance assessment and validation from simulated and field measured data. Subspace based methods have been use to improve previous results from block processing techniques. Bootstrap techniques have been developed to estimate confidence intervals for the electromechanical modes from field measured data. Results were obtained using injected signal data provided by BPA. A new probing signal was designed that puts more strength into the signal for a given maximum peak to peak swing. Further simulations were conducted on a model based on measured data and with the modifications of the 19-machine simulation model. Montana Tech researchers participated in two primary activities: (1) continued development of the 19-machine simulation test system to include a DC line; and (2) extensive simulation analysis of the various system identification algorithms and bootstrap techniques using the 19 machine model. Researchers at the University of Alaska-Fairbanks focused on the development and testing of adaptive filter algorithms for mode estimation using data generated from simulation models and on data provided in collaboration with BPA and PNNL. There efforts consist of pre-processing field data, testing and refining adaptive filter techniques (specifically the Least Mean Squares (LMS), the Adaptive Step-size LMS (ASLMS), and Error Tracking (ET) algorithms). They also improved convergence of the adaptive algorithms by using an initial estimate from block processing AR method to initialize the weight vector for LMS. Extensive testing was performed on simulated data from the 19 machine model. This project was also extensively involved in the WECC (Western Electricity Coordinating Council) system wide tests carried out in 2005 and 2006. These tests involved injecting known probing signals into the western power grid. One of the primary goals of these tests was the reliable estimation of electromechanical mode properties from measured PMU data. Applied to the system were three types of probing inputs: (1) activation of the Chief Joseph Dynamic Brake, (2) mid-level probing at the Pacific DC Intertie (PDCI), and (3) low-level probing on the PDCI. The Chief Joseph Dynamic Brake is a 1400 MW disturbance to the system and is injected for a half of a second. For the mid and low-level probing, the Celilo terminal of the PDCI is modulated with a known probing signal. Similar but less extensive tests were conducted in June of 2000. The low-level probing signals were designed at the University of Wyoming. A number of important design factors are considered. The designed low-level probing signal used in the tests is a multi-sine signal. Its frequency content is focused in the range of the inter-area electromechanical modes. The most frequently used of these low-level multi-sine signals had a period of over two minutes, a root-mean-square (rms) value of 14 MW, and a peak magnitude of 20 MW. Up to 15 cycles of this probing signal were injected into the system resulting in a processing gain of 15. The resulting measured response at points throughout the system was not much larger than the ambient noise present in the measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating perturbed stress from 3-D borehole displacements induced by fluid injection in fractured or faulted shales

SUMMARY Hydrofracturing stress measurements in fractured and anisotropic shales are notoriously difficult, because opening of existing geological features tends to prevent the creation of a pure hydraulic fracture perpendicular to the least compressive principal stress. Here we show how adding 3-D borehole-displacement measurements while conducting the hydraulic injection test helps to better constrain the principal stress orientations and magnitudes. We developed a 3-D fully coupled hydromechanical numerical model to analyse the displacement, fluid pressure and injection flow-rate data measured during an injection pressure-step-rate test conducted to activate a faulted borehole interval in the Mont Terri Opalinus Clay (Switzerland). We find that injected fluids can only penetrate the fault when it is at or above the Coulomb failure pressure. Borehole displacement orientations are sensitive to a ∼15° variation in the stress–tensor orientation and a 1 MPa stress magnitude variation. Although some dispersion occurs while rupture is propagating along the fault plane ∼4 m away from the borehole, the maximum density of displacement orientations consistently informs about the stress orientation. Thus, an extended injection step-rate approach coupled with an accurate in situ measurement of the borehole wall displacements can be used to better constrain the local stress field perturbations in fractured shales and in heterogeneous rock in general.

Guglielmi, Yves↗

Insights into the hydro-mechanical behavior of a decimeter-scale fracture using the mini-SIMFIP probe

ABSTRACT: Understanding hydro-mechanical couplings in fractured rocks is essential for predicting the rock mass response during high-pressure fluid injection, including the stimulation of enhanced geothermal systems. However, fluid-driven fracture dislocations are challenging to measure due to the need for local displacement data at high fluid pressures. In this study, fluid-driven displacement across a decimeter-scale laboratory fracture was investigated using the mini-SIMFIP (step rate injection method for fracture in-situ properties) probe, which is a smaller version of the SIMFIP tool (Guglielmi et al., 2014). The mini-SIMFIP probe is able to resolve the full 3D displacement vector of a fracture. The probe was installed in one of two boreholes across a decimeter-scale saw-cut granite fracture. Two pressure step injection tests were conducted under the same isotropic stress conditions. By varying injection between the boreholes, we estimated the aperture profile across the fracture. The results show a consistent pressure-dependent opening as long as steady-state flow was maintained. At a certain pressure step, steady-state conditions were no longer achievable and the fracture opened rapidly. The pressure-opening relationship diverged between the two tests and indicated a homogenization of the aperture profile and an increase in the non-linearity of the flow regime.

Osten, J↗

Characterization and controllability of radiated power via extrinsic impurity seeding in strongly negative triangularity plasmas in DIII-D

Experiments with extrinsic impurity seeding in strongly negative triangularity shapes in DIII-D achieved radiated power fractions (relative to input power) of up to ≈85% total radiation and ≈55% core radiation in steady-operating conditions. The relationship between core and total radiation was sensitive to impurity species and input power. Attempts to reach higher radiation levels via higher impurity flows resulted in radiative collapse disruptions. Nitrogen, neon, argon, and krypton were tested. Injection was by gas puffing, usually controlled by feeding back real-time estimates for core or total radiating fractions ($P_\textrm{rad} / P_\textrm{input}$). Argon and krypton were controlled by feeding back total radiating fraction, whereas neon was controlled by feeding back the core radiating fraction, due to the lower efficiency of neon as a divertor radiator. Nitrogen flows were pre-programmed. Reasonable total $P_\textrm{rad}$ control target following was achieved with argon or krypton. Control was more challenging with the neon/core radiation configuration, which was more prone to slow response and overshooting of the control target. Poor particle removal contributed to the control challenge: neon particle inventory within the last closed flux surface was roughly constant for up to 1 s (the longest duration tested) after neon injection was halted. However, separate experiments with laser-blow off of non-recycling impurities measured a short impurity confinement time, on the scale of the energy confinement time of ∼100 ms. Modeling with the Aurora impurity transport simulation matched experimental neon density profiles with full recycling (R = 1.0) and weak pumping but predicted rapid decreases in neon inventory if pumping were increased or recycling decreased. This indicates that changes outside the confined plasma (adding a well-placed pump) would improve controllability for all highly recycling species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In Situ Uranium Stabilization through Polyphosphate Remediation: Development and Demonstration at the Hanford Site 300 Area, Washington State

A site specific treatability test was conducted to optimize polyphosphate remediation technology for implementation through a field-scale technology demonstration to accelerate monitored natural attenuation of the uranium plume within the Hanford 300 Area aquifer. A focused application of polyphosphate was conducted in a source or “hot spot” area to reduce the inventory of available uranium that contributes to the groundwater plume through direct precipitation of uranyl-phosphate solids and secondary containment via precipitation of apatite acting as a long-term sorbent for uranium. The general treatability testing approach consisted of initial site characterization and setup, a polyphosphate injection test, and post-treatment performance assessment. Fundamental science studies were conducted with site specific sediment and groundwater to develop an effective remediation scheme for deployment of polyphosphate technology. In addition to remediating a portion of the plume, the data from this test provides valuable information for designing a full-scale remediation of uranium in the aquifer at the 300 Area of the Hanford Site. It will also provide a detailed understanding of the fundamental underpinnings necessary to evaluate the efficacy and potential utilization of polyphosphate technology at other sites with varying geochemical and hydrodynamic conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stimuli Responsive/Rheoreversible Hydraulic Fracturing Fluids for Enhanced Geothermal Energy Production (Part II)

We have used an environmentally friendly and recyclable hydraulic fracturing fluid - diluted aqueous solutions of polyallylamine or PAA – for reservoir stimulation in Enhanced Geothermal System (EGS). This fluid undergoes a controlled and large volume expansion with a simultaneous increase in viscosity triggered by CO2 at EGS temperatures. We are presenting here the results of laboratory-scale hydraulic fracturing experiment using the fluid on small cylindrical rock cores (1.59 cm in diameter and 5.08 cm in length) from the Coso geothermal field in California. Rock samples consisted of Mesozoic diorite metamorphosed to greenschist facies. The experiments were conducted on 5 samples for realistic ranges of pressures (up to 275 bar) and temperatures (up to 210 °C) for both the rock samples and the injected fluid. After fracturing, cores were subjected to a CO2 leakage test, injection of KI solution, and X-ray microtomography (XMT) scanning to examine the formation and distribution of fractures. The design and conduct of these experiments will be presented and discussed in details. Based on the obtained XMT images, Computational Fluid Dynamics (CFD) simulations were then performed to visualize hydraulic fractures and compute the bulk permeability. OpenFOAM (OpenCFD Ltd., Reading, UK), was used to solve the steady state simulation. The flow predictions, based upon the laminar, 3-D, incompressible Navier-Stokes equations for fluid mass and momentum, show the remarkable stimulation of the permeability in the core samples and demonstrate the efficiency of such a CO2 triggered fluid in EGS.

CO2-activated↗

Utah FORGE: Well 14-2 Logs and Data from Roosevelt Hot Spring Area

This is a compilation of logs and data from Well 14-2 in the Roosevelt Hot Springs area in Utah. This well is also in the Utah FORGE study area. Data includes: flowmeter survey (1989), geochemistry (1977-1978, 1977-1983), injection test data (1979, 1982), and spinner surveys (1989, 1985-1986). Logs include: borehole compensated sonic and gamma ray (600'-6112'), borehole geometry and gamma ray (50'-4829'), caliper (0'-1720'), compensated neutron formation density (600'-6121'), induction electric (650'-6118'), mud log (79'-6100'), steam injection survey (50'-1175'), subsurface pressure surveys (0'-6087'), and subsurface temperature surveys (0'-6106'). The file is in a compressed .zip format and there is a data inventory table (Excel spreadsheet) in the root folder that is a guide to the data that is accessible in subfolders.

14-2↗

JV Task 122 - Assessment of Mercury Control Options for the San Miguel Electric Cooperative Power Plant

In the United States, testing has been under way at electric coal-fired power plants to find viable and economical mercury control strategies to meet pending regulations. San Miguel Electric Cooperative (SMEC) engaged the Energy & Environmental Research Center (EERC) through a request for proposal (RFP) to perform research tests to evaluate sorbent-based technologies at its coal-fired San Miguel Generating Station to identify possible technology options that could be used by SMEC to meet the mercury reduction requirements of future U.S. federal standards. The goal of the testing was to target a mercury removal of {ge}90%. The EERC has successfully field-tested several sorbent-based technologies in previous projects that offer promise and potential to achieve a target removal of {ge}90%. Based on these field test results, yet recognizing that fuel type and plant operating conditions affect mercury capture significantly, the EERC proposed research tests to evaluate potential sorbent-based technologies provided by Norit Americas and the EERC that could potentially meet SMEC's mercury control objectives. Over the period of May through mid-June 2008, the EERC tested injection of both treated and nontreated activated carbon (AC) provided by Norit Americas and sorbent enhancement additives (SEAs) provided by the EERC. Tests were performed at San Miguel Unit 1 (450 MW) and included injection at the inlet of the air heater (AH) (temperature of 720 F). The test coal was a Texas lignite fuel with an average moisture content of 31.19%, an ash content of 26.6%, a heating value of 5,094 Btu/lb, a sulfur content of 2.7%, and a mercury concentration of 0.182 ppm, all reported on an as-received basis. Pilot-scale testing results identified DARCO{reg_sign} Hg-LH, SEA2 + DARCO{reg_sign} Hg, and the ChemMod sorbents as technologies with the potential to achieve the target mercury removal of {ge}90% at the full-scale test. Mercury concentrations were tracked with continuous mercury monitors (CMMs) at the electrostatic precipitator (ESP) inlet (ESP In), scrubber inlet, and scrubber outlet of San Miguel Unit 1, and a dry sorbent trap method was used to take samples periodically to measure mercury concentrations at the each of the CMM sampling locations described above. A limited number of Ontario Hydro (OH) measurements were also conducted. Removal efficiencies were calculated from mercury-in-coal values to scrubber out CMM values. Sorbent trap samples taken at the each sampling location outlet were found to be fairly consistent with CMM values. A maximum mercury removal of 78.5% was achieved with the SEA2 + DARCO Hg sorbent combination at injection rates of 50 ppm and 4 lb/Macf, respectively. An injection rate of 4 lb/Macf for DARCO Hg-LH and DARCO Hg resulted in mercury removals of 70.0% and 64.2%, respectively. These mercury reduction values were achieved at full load and at stable plant operating conditions. Scrubber reemission was observed during sorbent injection and had a significant effect on coal to scrubber out mercury removal values. When the sorbents were injected into San Miguel Unit 1 at the AH inlet, no effects on unit operations were observed. ESP performance throughout the test period was fairly steady, with only one minor breakdown. However, it should be noted that test durations were short.

01 COAL, LIGNITE, AND PEAT↗

Annual report of groundwater monitoring at Centralia, Kansas, in 2009.

In September 2005, periodic sampling of groundwater was initiated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Centralia, Kansas. The sampling at Centralia is being performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE). The objective is to monitor levels of carbon tetrachloride contamination identified in the groundwater at Centralia (Argonne 2003, 2004, 2005a). Under the KDHE-approved monitoring plan (Argonne 2005b), the groundwater was sampled twice yearly from September 2005 until September 2007 for analyses for volatile organic compounds (VOCs), as well as measurement of selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation (reductive dechlorination) processes in the subsurface environment. The results from the two-year sampling program demonstrated the presence of carbon tetrachloride contamination at levels exceeding the KDHE Tier 2 risk-based screening level (RBSL) of 5 {micro}g/L for this compound in a localized groundwater plume that has shown little movement. The relative concentrations of chloroform, the primary degradation product of carbon tetrachloride, suggested that some degree of reductive dechlorination or natural biodegradation was taking place in situ at the former CCC/USDA facility on a localized scale. The CCC/USDA subsequently developed an Interim Measure Conceptual Design (Argonne 2007b), proposing a pilot test of the Adventus EHC technology for in situ chemical reduction (ISCR). The proposed interim measure (IM) was approved by the KDHE in November 2007 (KDHE 2007). Implementation of the pilot test occurred in November-December 2007. The objective was to create highly reducing conditions that would enhance both chemical and biological reductive dechlorination in the injection test area (Argonne 2009a). The KDHE (2008a) has requested that sitewide monitoring continue at Centralia until a final remedy has been selected (as part of a Corrective Action Study [CAS] evaluation) and implemented for this site. In response to this request, twice-yearly sampling of 10 monitoring wells and 6 piezometers (Figure 1.1) previously approved by the KDHE for monitoring of the groundwater at Centralia (KDHE 2005a,b) was continued in 2008. The sampling events under this extension of the two-year (2005-2007) monitoring program occurred in March and September 2008 (Argonne 2008b, 2009b). Additional piezometers specifically installed to evaluate the progress of the IM pilot test (PMP1-PMP9; Figure 1.2) were also sampled in 2008; the results of these analyses were reported and discussed separately (Argonne 2009a). On the basis of results of the 2005-2008 sitewide monitoring and the 2008 IM pilot test monitoring, the CCC/USDA recommended a revised sampling program to address both of the continuing monitoring objectives until a CAS for Centralia is developed (Section 4.2 in Argonne 2009b). The elements of this interim monitoring plan are as follows: (1) Annual sampling of twelve previously established (before the pilot test) monitoring points (locations identified in Figure 1.3) and the five outlying pilot test monitoring points (PMP4, PMP5, PMP6, PMP7, PMP9; Figure 1.4); and (2) Sampling twice yearly at the five pilot test monitoring points inside the injection area (PMP1-PMP3, PMP8, MW02; Figure 1.4). With the approval of the KDHE (2009), groundwater sampling for analyses of VOCs and selected other geochemical parameters was conducted at Centralia under the interim monitoring program outlined above in April and October 2009. This report documents the findings of the 2009 monitoring events.

54 ENVIRONMENTAL SCIENCES↗

Annual report of groundwater monitoring at Centralia, Kansas, in 2010.

In September 2005, periodic sampling of groundwater was initiated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Centralia, Kansas. The sampling at Centralia is performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE). The objective is to monitor levels of carbon tetrachloride contamination identified in the groundwater at Centralia (Argonne 2003, 2004, 2005a). Under the KDHE-approved monitoring plan (Argonne 2005b), the groundwater was sampled twice yearly from September 2005 until September 2007 for analyses for volatile organic compounds (VOCs), as well as measurement of selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation processes (reductive dechlorination) in the subsurface environment (Argonne 2006, 2007a, 2008a). The results from the two-year sampling program demonstrated the presence of carbon tetrachloride contamination at levels exceeding the KDHE Tier 2 risk-based screening level (RBSL) of 5 {micro}g/L for this compound, in a localized groundwater plume that has shown little movement. The relative concentrations of chloroform, the primary degradation product of carbon tetrachloride, suggested that some degree of reductive dechlorination or natural biodegradation was talking place in situ at the former CCC/USDA facility on a localized scale. The CCC/USDA subsequently developed an Interim Measure Conceptual Design (Argonne 2007b), proposing a pilot test of the Adventus EHC technology for in situ chemical reduction (ISCR). The proposed interim measure (IM) was approved by the KDHE in November 2007 (KDHE 2007). Implementation of the pilot test occurred in November-December 2007. The objective was to create highly reducing conditions that would enhance both chemical and biological reductive dechlorination in the injection test area (Argonne 2009a). The KDHE (2008a) requested that sitewide monitoring continue until a final remedy is selected (as part of a Corrective Action Study [CAS] evaluation) and implemented. In response to this request, the established sampling across the site and additional sampling in the IM pilot test area continued in 2008 (Argonne 2008b, 2009a,b). On the basis of results of the 2005-2008 sitewide monitoring and the 2008 IM pilot test monitoring, the CCC/USDA recommended a revised sampling program for both the wider site and the IM pilot test area (Section 4.2 in Argonne 2009b). The elements of this interim monitoring plan are as follows: (1) Annual sampling of twelve monitoring points across the site (Figure 1.1) and five outlying IM pilot test monitoring points (PMP4, PMP5, PMP6, PMP7, PMP9; Figure 1.2); and (2) Twice yearly sampling of five IM pilot test monitoring points inside the injection area (PMP1-PMP3, PMP8, MW02; Figure 1.2). With the approval of the KDHE (2009), the initial groundwater sampling for VOCs and geochemical analyses under the interim monitoring plan outlined above was conducted in 2009 (Argonne 2010). The present report documents the findings of the 2010 monitoring events, conducted on April 5 and September 19-21, 2010.

54 ENVIRONMENTAL SCIENCES↗