Search NASA⌕ Search

SEARCH · Search NASA

Results for “insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging

Purpose: In this study, the authors present a silicon photomultiplier (SiPM)-based positron emission tomography (PET) insert dedicated to small animal imaging with high system performance and robustness to temperature change. Methods: The insert consists of 64 LYSO-SiPM detector blocks arranged in 4 rings of 16 detector blocks to yield a ring diameter of 64 mm and axial field of view of 55 mm. Each detector block consists of a 9 × 9 array of LYSO crystals (1.2 × 1.2 × 10 mm{sup 3}) and a monolithic 4 × 4 SiPM array. The temperature of each monolithic SiPM is monitored, and the proper bias voltage is applied according to the temperature reading in real time to maintain uniform performance. The performance of this PET insert was characterized using National Electrical Manufacturers Association NU 4-2008 standards, and its feasibility was evaluated through in vivo mouse imaging studies. Results: The PET insert had a peak sensitivity of 3.4% and volumetric spatial resolutions of 1.92 (filtered back projection) and 0.53 (ordered subset expectation maximization) mm{sup 3} at center. The peak noise equivalent count rate and scatter fraction were 42.4 kcps at 15.08 MBq and 16.5%, respectively. By applying the real-time bias voltage adjustment, an energy resolution of 14.2% ± 0.3% was maintained and the count rate varied ≤1.2%, despite severe temperature changes (10–30 °C). The mouse imaging studies demonstrate that this PET insert can produce high-quality images useful for imaging studies on the small animals. Conclusions: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previously developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Generation and Characterization of the Western Regional Research Center Brachypodium T-DNA Insertional Mutant Collection

The model grass Brachypodium distachyon (Brachypodium) is an excellent system for studying the basic biology underlying traits relevant to the use of grasses as food, forage and energy crops. To add to the growing collection of Brachypodium resources available to plant scientists, we further optimized our Agrobacterium tumefaciens-mediated high-efficiency transformation method and generated 8,491 Brachypodium T-DNA lines. We used inverse PCR to sequence the DNA flanking the insertion sites in the mutants. Using these flanking sequence tags (FSTs) we were able to assign 7,389 FSTs from 4,402 T-DNA mutants to 5,285 specific insertion sites (ISs) in the Brachypodium genome. More than 29% of the assigned ISs are supported by multiple FSTs. T-DNA insertions span the entire genome with an average of 19.3 insertions/Mb. The distribution of T-DNA insertions is non-uniform with a larger number of insertions at the distal ends compared to the centromeric regions of the chromosomes. Insertions are correlated with genic regions, but are biased toward UTRs and non-coding regions within 1 kb of genes over exons and intron regions. More than 1,300 unique genes have been tagged in this population. Information about the Western Regional Research Center Brachypodium insertional mutant population is available on a searchable website (http://brachypodium.pw.usda.gov) designed to provide researchers with a means to order T-DNA lines with mutations in genes of interest.

59 BASIC BIOLOGICAL SCIENCES↗

Methanol Formation via Oxygen Insertion Chemistry in Ices

We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrochemical and Chemical Insertion for Energy Transformation and Switching

Insertion is a widely utilized process for reversibly changing the stoichiometry of a solid through a chemical or electrochemical stimulus. Insertion is instrumental to many energy technologies, including batteries, fuel cells, and hydrogen storage, and has been the subject of extensive investigations. More recently, solid-state switching devices utilizing insertion have drawn significant interest; such devices dynamically switch a material's chemical stoichiometry, changing it from one state to another. This paper illustrates the fundamental properties and mechanisms of insertion, including reaction, diffusion, and phase transformation, and discusses recent developments in characterization in these fields. Finally, we also review new classes of recently demonstrated insertion devices, which reversibly switch mechanical and electronic properties, and show how the fundamental mechanisms of insertion can be used to design improved switching devices.

25 ENERGY STORAGE↗

Core Vessel Insert Handling Robot for the Spallation Neutron Source

The Spallation Neutron Source provides the world's most intense pulsed neutron beams for scientific research and industrial development. Its eighteen neutron beam lines will eventually support up to twenty-four simultaneous experiments. Each beam line consists of various optical components which guide the neutrons to a particular instrument. The optical components nearest the neutron moderators are the core vessel inserts. Located approximately 9 m below the high bay floor, these inserts are bolted to the core vessel chamber and are part of the vacuum boundary. They are in a highly radioactive environment and must periodically be replaced. During initial SNS construction, four of the beam lines received Core Vessel Insert plugs rather than functional inserts. Remote replacement of the first Core Vessel Insert plug was recently completed using several pieces of custom-designed tooling, including a highly complicated Core Vessel Insert Robot. The design of this tool are discussed.

43 PARTICLE ACCELERATORS↗

An Assessment of Radiologically Inserted Transoral and Transgastric Gastroduodenal Stents to Treat Malignant Gastric Outlet Obstruction

Introduction: Self-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients’ case notes. Univariate survival analysis was performed. Results: Between December 2000 and January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39–89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1–624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of uranium oxide (UO 2 ) fuel with molybdenum (Mo) inserts on pressurized water reactor performance and safety

This work investigates nuclear reactor performance and safety characteristics of UO 2 with high thermal conductivity Mo insert structures by using multiphysics modeling techniques. Additionally, the purpose of this study is to use scoping analyses to quantify the impact of using Mo inserts from neutronic and heat transfer standpoints. Attention is given to reactor performance parameters, such as cycle length, maximum fuel temperature, temperature gradients in the fuel, and stored energy in the fuel. The finite-element code BISON and the Monte Carlo particle transport code Serpent were used to perform sensitivity analyses on the Mo insert geometry to optimize the insert design and inform larger scale modeling that required the homogenization of the UO 2 and Mo. Although BISON is often used as a fuel performance analysis tool, it is used in this context for heat transfer analysis only. Fuel performance optimization is outside the scope of the current study, but would be important for future work focused on this concept. The results showed that the insert had little impact on neutronic performance and that homogenizing the UO 2 and Mo was acceptable for reactor physics calculations. Reactivity temperature coefficients calculated using homogeneous UO 2 -Mo were shown to be relatively similar to UO 2 , but higher Mo content and 235 U enrichment can reduce the worth of soluble boron and control rods. The effect of insert geometry on heat transfer was much greater, and an approximately 15–20% difference in maximum fuel temperature was predicted between the best and worst performing heat transfer geometries. Furthermore, thermal conductivity calibration based on the finite element analysis results was performed to improve the accuracy of temperature predictions in reactor analysis models that homogenized the UO 2 -Mo fuel. Compared with UO 2 in a pressurized water reactor (PWR), the optimized UO 2 -Mo design increased the margin to fuel melt by 13–32% across the fuel cycle, but it requires the 235U enrichment to exceed 5% to match the cycle length of conventional UO 2 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and Theoretical Study of CO 2 Insertion into Ruthenium Hydride Complexes

The ruthenium hydride [RuH(CNN)(dppb)] (1; CNN = 2-aminomethyl-6-tolylpyridine, dppb = 1,4-bis(diphenylphosphino)butane) reacts rapidly and irreversibly with CO 2 under ambient conditions to yield the corresponding Ru formate complex 2. In contrast, the Ru hydride 1 reacts with acetone reversibly to generate the Ru isopropoxide, with the reaction free energy $ΔG°$ 298 K $ = -3.1$ kcal/mol measured by 1 H NMR in tetrahydrofuran-$d_8$. Density functional theory (DFT), calibrated to the experimentally measured free energies of ketone insertion, was used to evaluate and compare the mechanism and energetics of insertion of acetone and CO 2 into the Ru–hydride bond of 1. The calculated reaction coordinate for acetone insertion involves a stepwise outer-sphere dihydrogen transfer to acetone via hydride transfer from the metal and proton transfer from the N–H group on the CNN ligand. In contrast, the lowest energy pathway calculated for CO 2 insertion proceeds by an initial Ru–H hydride transfer to CO 2 followed by rotation of the resulting N–H-stabilized formate to a Ru–O-bound formate. DFT calculations were used to evaluate the influence of the ancillary ligands on the thermodynamics of CO 2 insertion, revealing that increasing the $π$ acidity of the ligand cis to the hydride ligand and increasing the $σ$ basicity of the ligand trans to it decreases the free energy of CO 2 insertion, providing a strategy for the design of metal hydride systems capable of reversible, ergoneutral interconversion of CO 2 and formate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isolation of a Cu–H Monomer Enabled by Remote Steric Substitution of a N-Heterocyclic Carbene Ligand: Stoichiometric Insertion and Catalytic Hydroboration of Internal Alkenes

Transient Cu–H monomers have long been invoked in the mechanisms of substrate insertion in Cu–H catalysis. Their role from Cu–H aggregates has been mostly inferred since ligands to stabilize these monomeric intermediates for systematic studies remain limited. Within the last decade, new sterically demanding N-heterocyclic carbene (NHC) ligands have led to isolable Cu–H dimers and, in some cases, spectroscopic characterization of Cu–H monomers in solution. In this work, we report an NHC ligand, IPr*R, containing para R groups of CHPh 2 and CPh 3 on the ligand periphery for the isolation of a Cu–H monomer for insertion of internal alkenes. This reactivity has not been reported for (NHC)CuH complexes despite their common application in Cu–H-catalyzed hydrofunctionalization. Changing from CHPh 2 to CPh 3 impacts the relative concentration of Cu–H monomers, rate of alkene insertion, and reaction of a trisubstituted internal alkene. Specifically, for R = CPh 3 , monomeric (IPr*CPh 3 )CuH was isolated and provided >95% monomer (10 mM in C 6 D 6 ). In contrast, for R = CHPh 2 , solutions of [(IPr*CHPh 2 )CuH] 2 are 80% dimer and 20% (IPr*CHPh 2 )CuH monomer at 25 °C based on 1 H, 13 C, and 1 H– 13 C HMBC NMR spectroscopy. Quantitative 1 H NMR kinetic studies on cyclopentene insertion into Cu–H complexes to form the corresponding Cu–cyclopentyl complexes demonstrate a strong dependence on the rate of insertion and concentration of the Cu–H monomer. Only (IPr*CPh 3 )CuH, which has a high monomer concentration, underwent regioselective insertion of a trisubstituted internal alkene, 1-methylcyclopentene, to give (IPr*CPh 3 )Cu(2-methylcyclopentyl), which has been crystallographically characterized. We also demonstrated that (IPr*CPh 3 )CuH catalyzes the hydroboration of cyclopentene and methylcyclopentene with pinacolborane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Marker-free carotenoid-enriched rice generated through targeted gene insertion using CRISPR-Cas9

Targeted insertion of transgenes at pre-determined plant genomic safe harbors provides a desirable alternative to insertions at random sites achieved through conventional methods. Most existing cases of targeted gene insertion in plants have either relied on the presence of a selectable marker gene in the insertion cassette or occurred at low frequency with relatively small DNA fragments (<1.8 kb). Here, we report the use of an optimized CRISPR-Cas9-based method to achieve the targeted insertion of a 5.2 kb carotenoid biosynthesis cassette at two genomic safe harbors in rice. We obtain marker-free rice plants with high carotenoid content in the seeds and no detectable penalty in morphology or yield. Whole-genome sequencing reveals the absence of off-target mutations by Cas9 in the engineered plants. These results demonstrate targeted gene insertion of marker-free DNA in rice using CRISPR-Cas9 genome editing, and offer a promising strategy for genetic improvement of rice and other crops.

59 BASIC BIOLOGICAL SCIENCES↗

Search for active and inactive ion insertion sites in organic crystalline materials

The position of mobile active and inactive ions, specifically ion insertion sites, within organic crystals, significantly affects the properties of organic materials used for energy storage and ionic transport. Identifying the positions of these atomic (and ionic) sites in an organic crystal is challenging, especially when the element has low X-ray scattering power, such as lithium (Li) and hydrogen, which are difficult to detect by powder X-ray diffraction. First-principles calculations, exemplified by density functional theory (DFT), are very practical for confirming the relative stability of ion positions in materials. However, the lack of effective strategies to identify ion sites in these organic crystalline frameworks renders this task extremely challenging. This work presents two algorithms: the (i) efficient location of ion insertion sites from extrema in electrostatic local potential and charge density (ELIISE), and the (ii) ElectRostatic InsertioN (ERIN), which leverage charge density and electrostatic potential fields accessed from first-principles calculations, combined with the Simultaneous Ion Insertion and Evaluation (SIIE) workflow. SIIE inserts all ions simultaneously—to determine ion positions in organic crystals. We demonstrate that these methods accurately reproduce known ion positions in 16 organic materials and identify previously overlooked low-energy sites in tetralithium 2,6-naphthalenedicarboxylate (Li4NDC), an organic electrode material, highlighting the importance of inserting all ions simultaneously, as in the SIIE workflow. These algorithms are also integrated with off-the-shelf machine learning potentials, yielding promising results comparable to first-principles findings.

Gopidi, Harshan Reddy [Argonne National Laboratory↗

The FADE mass-stat: A technique for inserting or deleting particles in molecular dynamics simulations

The emergence of new applications of molecular dynamics (MD) simulation calls for the development of mass-statting procedures that insert or delete particles on-the-fly. In this paper we present a new mass-stat which we term FADE, because it gradually “fades-in” (inserts) or “fades-out” (deletes) molecules over a short relaxation period within a MD simulation. FADE applies a time-weighted relaxation to the intermolecular pair forces between the inserting/deleting molecule and any neighbouring molecules. The weighting function we propose in this paper is a piece-wise polynomial that can be described entirely by two parameters: the relaxation time scale and the order of the polynomial. FADE inherently conserves overall system momentum independent of the form of the weighting function. We demonstrate various simulations of insertions of atomic argon, polyatomic TIP4P water, polymer strands, and C{sub 60} Buckminsterfullerene molecules. We propose FADE parameters and a maximum density variation per insertion-instance that restricts spurious potential energy changes entering the system within desired tolerances. We also demonstrate in this paper that FADE compares very well to an existing insertion algorithm called USHER, in terms of accuracy, insertion rate (in dense fluids), and computational efficiency. The USHER algorithm is applicable to monatomic and water molecules only, but we demonstrate that FADE can be generally applied to various forms and sizes of molecules, such as polymeric molecules of long aspect ratio, and spherical carbon fullerenes with hollow interiors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of inserted Mo layer on the thermal stability of perpendicularly magnetized Ta/Mo/Co{sub 20}Fe{sub 60}B{sub 20}/MgO/Ta films

We studied the thermal stability of perpendicular magnetic anisotropy (PMA) in Ta/Mo/CoFeB/MgO/Ta films with and without inserted Mo layers. In the absence of a Mo layer, the films show PMA at annealing temperatures below 300 °C. On the other hand, the insertion of a Mo layer preserves PMA at annealing temperatures of up to 500 °C; however, a higher annealing temperature leads to the collapse of PMA. X-ray photoelectron spectroscopy (XPS) and high-resolution transmission electron microscopy (HRTEM) were used to study the microstructure of the films to understand the deterioration of PMA. The XPS results show that the segregation of Ta is partly suppressed by inserting a Mo layer. Once inserted, Mo does not remain at the interface of Ta and CoFeB but migrates to the surface of the films. The HRTEM results show that the crystallization of the MgO (001) texture is improved owing to the higher annealing temperature of the Mo inserted sample. A smooth and clear CoFeB/MgO interface is evident. The inserted Mo layer not only helps to obtain sharper and smoother interfaces but also contributes to the crystallization after the higher annealing temperature of films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhancement of voltage-controlled magnetic anisotropy through precise control of Mg insertion thickness at CoFeB|MgO interface

We studied the impact of different insertion layers (Ta, Pt, and Mg) at the CoFeB|MgO interface on voltage-controlled magnetic anisotropy (VCMA) effect and other magnetic properties. Inserting a very thin Mg layer of 0.1–0.3 nm yielded a VCMA coefficient of 100 fJ/V-m, more than 3 times higher than the average values of around 30 fJ/V-m reported in Ta|CoFeB|MgO-based structures. Ta and Pt insertion layers also showed a small improvement, yielding VCMA coefficients around 40 fJ/V-m. Electrical, magnetic, and X-ray diffraction results reveal that a Mg insertion layer of around 1.2 nm gives rise to the highest perpendicular magnetic anisotropy, saturation magnetization, as well as the best CoFe and MgO crystallinity. Other Mg insertion thicknesses give rise to either under- or over-oxidation of the CoFe|MgO interface; a strong over-oxidation of the CoFe layer leads to the maximum VCMA effect. These results show that precise control over the Mg insertion thickness and CoFe oxidation level at the CoFeB|MgO interface is crucial for the development of electric-field-controlled perpendicular magnetic tunnel junctions with low write voltage.

36 MATERIALS SCIENCE↗

Precision grid and hand motion for accurate needle insertion in brachytherapy

Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of the 256 GAPD/scintillator elements of a detector block was <3% for 60 min, and simultaneous PET and MR images of a brain phantom were successfully acquired. Conclusions: Experimental results indicate that a compact and lightweight PET insert for hybrid PET/MRI can be developed using GAPD arrays and charge signal transmission method proposed in this study without significant interference.

60 APPLIED LIFE SCIENCES↗