Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumentation: interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Towards quantum telescopes: demonstration of a two-photon interferometer for precision astrometry

Classical optical interferometry requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with a corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.

47 OTHER INSTRUMENTATION↗

Requirements for probing chiral Casimir-Polder forces in a molecular Talbot-Lau interferometer

We theoretically investigate the influence of chiral Casimir-Polder (CP) forces in Talbot-Lau interferometry, based on three nanomechanical gratings. We study scenarios where the second grating is either directly written into a chiral material or where the nanomask is coated with chiral substances. We show requirements for probing enantiospecific effects in matter-wave interferometry in the transmission signal and the interference fringe visibility, which depend on the de Broglie wavelength and the molecular chirality. The proposed setup is particularly sensitive to CP forces in the nonretarded regime where chiral effects can be comparable in magnitude to their electric and magnetic counterparts. While the first and third gratings do not change the phase of the matter wave, applying a coating of chiral substances to them enhances the instrument's chiral selectivity. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Simultaneous measurement of surface velocity and plasma density with interferometric velocimetry

The apparent velocity measured by an interferometric surface velocimeter is a function of both the surface velocity and the time derivative of the refractive index along the measurement path. We employed this dual sensitivity to simultaneously measure km/s surface velocities and 10 18 cm -3 average plasma densities with combined VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry) measurements in experiments performed on the Z Pulsed Power Facility. We detail the governing equations, associated assumptions, and analysis specifics and show that the surface velocity can be extracted without knowledge of the specific plasma density profile.

47 OTHER INSTRUMENTATION↗

Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer

We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

47 OTHER INSTRUMENTATION↗

Laser adaptive holographic hydroacoustic intensimeter

A new type of a vector hydrophone, a laser adaptive hydroacoustic intensimeter, is investigated. Two identical, spatially separated coil-type sensors are used as a primary receiver of the acoustic signal. The signals received at the sensor output are phase demodulated in a two-channel adaptive holographic interferometer based on two dynamic holograms multiplexed in a CdTe photorefractive crystal. Using a laser intensimeter, the acoustic field formed in a limited volume is studied. The performance characteristics of the intensimeter are determined experimentally; its threshold sensitivity, according to the acoustic field intensity, constitutes 0.1 × 10{sup −13} W m{sup −2}. (laser applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of predictive performance models for supersonic gas-jet nozzles at the Laboratory for Laser Energetics

We present results characterizing the neutral-density distributions produced by the supersonic nozzles used in experiments on the OMEGA-60 and OMEGA-EP laser systems at the University of Rochester’s Laboratory for Laser Energetics (LLE). Axisymmetric Fluent® simulations using LLE nozzle specifications capture the viscous effects, gas expansion, and shock waves that complicate flow predictions for offsets above the nozzle exit. Here, these simulations show good agreement with neutral-density measurements obtained using a four-wave shearing interferometer. An analytical form is given for the plateau length. Fits to simulation data for boundary layer thickness, mean plateau density, and density ramps are given as functions of nozzle offset and nozzle backing pressure for a number of nozzles and gases.

47 OTHER INSTRUMENTATION↗

High Speed, Localized Multi-Point Strain Measurements on a Containment Vessel at 1.7 MHz Using Swept-Wavelength Laser-Interrogated Fiber Bragg Gratings

Dynamic elastic strain in ~1.8 and 1.0 m diameter containment vessels containing a high explosive detonation was measured using an array of fiber Bragg gratings. The all-optical method, called real-time localized strain measurement, recorded the strain for 10 ms after detonation with additional measurements being sequentially made at a rate of 1.7 MHz. A swept wavelength laser source provided the repetition rate necessary for such high-speed measurements while also providing enough signal strength and bandwidth to simultaneously measure 8 or more unique points on the vessel’s surface. The data presented here arethen compared with additional diagnostics consisting of a fast spectral interferometer and an optical backscatter reflectometer to show a comparison between the local and global changes in the vessel strain, both dynamically and statically to further characterize the performance of the localized strain measurement. The results are also compared with electrical resistive strain gauges and finite element analysis simulations.

47 OTHER INSTRUMENTATION↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

Thin-film lithium niobate electro-optic terahertz wave detector

Here, the design, fabrication, and validation of a thin-film lithium niobate on insulator (LNOI) electro-optic (EO) time-domain terahertz (THz) wave detector is reported. LNOI offers unprecedented properties for the EO detection of freely propagating THz wave radiation pulses and transient electric fields because of the large EO coefficient of the material, engineering of the velocity matching of the THz wave and optical wave, and much reduced detector size. The proof-of-concept device is realized using thin-film lithium niobate optical waveguides forming a Mach–Zehnder interferometer with interferometer arms electrically poled in opposite directions. THz waves are coupled effectively to the fully dielectric device from free space without using antennas or plasmonics. The detection of THz waves with frequencies up to 800 GHz is successfully demonstrated. The detector allows for the detection of THz frequency electric fields up to 4.6 MV/m. The observed frequency response of the device agrees well with theoretical predictions.

47 OTHER INSTRUMENTATION↗

Phase Demodulation by Frequency Chirping in Coherence Microwave Photonic Interferometry

This paper presents a signal processing method to demodulate the optical interference phase of cascaded individual optical fiber intrinsic Fabry-Perot interferometric (IFPI) sensors in a coherent microwave-photonic interferometry (CMPI) distributed sensing system. The new method utilizes the chirp effect of electro-optic modulator (EOM) to create a quasi-quadrature optical interference phase shift between two adjacent pulses which correspond to two adjacent reflection points in the time domain. The phase shift can be controlled by adjusting the bias voltage that is applied to the EOM. The interference phase is calculated by elliptically fitting the phase shift. The interference phase change is proportional to the optical path difference (OPD) change of the interferometer, and the sign can be used to differentiate the increase or decrease of the OPD. The method is demonstrated for distributed strain sensing, showing good linearity, high resolution and large dynamic range.

42 ENGINEERING↗

Real-time laser ultrasonic monitoring of laser-induced thermal processes

Abstract Intra- and inter-layer integrity of components fabricated with advanced manufacturing techniques, such as laser powder bed fusion, is dependent upon rapid heating, melting, and solidification processes. There is a need for new techniques to provide in situ feedback of these processes. Here a laser-based ultrasonic technique to probe thermal effects induced by a high-power continuous wave laser in titanium samples is described. Numerical simulations were performed to show that, for a spatially uniform heating beam, laser-induced surface acoustic waves are strongly influenced by surface heating conditions, are dispersive in the case of rapid heating, and that an abrupt velocity reduction happens upon the onset of surface melting. Furthermore, laser-based ultrasound experimental results which monitor the transient change of surface wave travel time associated with high power laser surface heating are provided. A pulsed laser is used to generate high frequency surface acoustic waves that propagate through the laser-heated region and are detected using a photorefractive crystal-based interferometer. Qualitative agreement is observed between theory and experiment with both showing a rapid reduction in the surface wave velocity at the onset of illumination and further decrease in surface wave velocity associated with melting. It is demonstrated that changes in the surface wave velocity can be used to track local heating and detect the onset of surface melting in real time.

36 MATERIALS SCIENCE↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Sagnac fourier spectrometer (SAFOS)

A technique and device to determine the spectrum of electromagnetic radiation in a certain range of wavelengths comprising: splitting said radiation into more than one beam; let these beams counter-propagate in a Sagnac-type ring interferometer; and imprinting a wavelength-dependent angular tilt onto the wavefront of each beam by at least one dispersive element which preferably is a transmission grating or grism; and re-combining the multiple beams on a detector that exhibits spatial resolution and can therefore resolve the fringes formed by interference; and perform the mathematical operations to determine the spectrum of said radiation from the obtained interferogram, wherein the dispersive element is mounted on a stage providing linear and/or rotational movement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A sensitive high repetition rate arrival time monitor for X-ray free electron lasers

X-ray free-electron laser sources enable time-resolved X-ray studies with unmatched temporal resolution. To fully exploit ultrashort X-ray pulses, timing tools are essential. However, new high repetition rate X-ray facilities present challenges for currently used timing tool schemes. Here we address this issue by demonstrating a sensitive timing tool scheme to enhance experimental time resolution in pump-probe experiments at very high pulse repetition rates. Our method employs a self-referenced detection scheme using a time-sheared chirped optical pulse traversing an X-ray stimulated diamond plate. By formulating an effective medium theory, we confirm subtle refractive index changes, induced by sub-milli-Joule intense X-ray pulses, that are measured in our experiment. The system utilizes a Common-Path-Interferometer to detect X-ray-induced phase shifts of the optical probe pulse transmitted through the diamond sample. Owing to the thermal stability of diamond, our approach is well-suited for MHz pulse repetition rates in superconducting linear accelerator-based free-electron lasers.

47 OTHER INSTRUMENTATION↗

Increasing Baselines and Precision of Optical Interferometers Using Two-Photon Interference

Observations using interferometers provide sensitivity to features of images on angular scales much smaller than any single telescope, on the order of Δθ ~ λ/b where b is the interferometric baseline. Present-day optical interferometers are essentially classical, interfering single photons with themselves. However, there is a new wave of interest in interferometry using multiple photons, whose mechanisms are inherently quantum mechanical, which offer the prospects of increased baselines and finer resolutions among other advantages. We will discuss recent ideas and results for quantum-assisted interferometry using the resource of entangled pairs, and specifically a two-photon amplitude technique aimed at improved precision in astrometry.

47 OTHER INSTRUMENTATION↗

Unveiling contextual realities by microscopically entangling a neutron

The development of qualitatively new measurement capabilities is often a prerequisite for critical scientific and technological advances. Here we introduce an unconventional quantum probe, an entangled neutron beam, where individual neutrons can be entangled in spin, trajectory and energy. The spatial separation of trajectories from nanometers to microns and energy differences from peV to neV will enable investigations of microscopic magnetic correlations in systems with strongly entangled phases, such as those believed to emerge in unconventional superconductors. We develop an interferometer to prove entanglement of these distinguishable properties of the neutron beam by observing clear violations of both Clauser-Horne-Shimony-Holt and Mermin contextuality inequalities in the same experimental setup. Our work opens a pathway to a future of entangled neutron scattering in matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗