Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrating sphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Nondestructive Characterization of Antireflective Coatings on PV Modules

Antireflective coatings (ARCs) are used on the vast majority of solar photovoltaic (PV) modules to increase power production. However, ARC longevity can vary from less than 1 to over 15 years depending on coating quality and deployment conditions. A technique that can quantify ARC degradation nondestructively on commercial modules would be useful both for in-field diagnostics and accelerated aging tests. In this article, we demonstrate that accurate measurements of ARC spectral reflectance can be performed using a modified commercially available integrating-sphere probe. The measurement is fast, accurate, nondestructive, and can be performed outdoors in full-sun conditions. We develop an interferometric model that estimates coating porosity, thickness, and fractional area coverage from the measured reflectance spectrum for a uniform single-layer coating. We demonstrate the measurement outdoors on an active PV installation, identify the presence of an ARC, and estimate the properties of the coating.

14 SOLAR ENERGY↗

Modeling thin layers of analytes on substrates for spectral analysis: use of solid/liquid n and k values to model reflectance spectra

Since solids are only sometimes seen en masse in a pure bulk form, and for liquids other than water almost never, a capability to model reflectance spectra from analytes deposited on various substrates would be highly advantageous. If available, the real, n ( ν ) , and imaginary, k ( ν ) , components of the complex refractive index, n n + i k , can be used to simulate infrared spectra, accounting for reflection, refraction, and absorption phenomena as a function of wavelength. We focus on using the Pacific Northwest National Laboratory (PNNL) derived n / k vectors for solid and liquid analytes deposited as thin layers on different types of substrates including conductors, such as aluminum, and inorganic dielectrics, such as glass. The model is an adaptation of the Monte Carlo ray trace modeling program, TracePro, extended through the use of its macrolanguage. The model is tested using thin films of organic liquids including silicone oil and no. 2 diesel fuel, as well as organic solids such as caffeine and acetaminophen on aluminum and glass. The predicted spectra for the solid films were compared to experimental hemispherical reflectance data measured using a Fourier transform spectrometer with an integrating sphere. The thickness of the calculated layer is a parameter for predicting the (transflectance) spectra and is obtained using the areal density measured from gravimetric methods to generate the thin-layer samples. Comparison of the calculated spectra with experimental hemispherical reflectance data shows excellent agreement, indicating promise for the use of measured n / k data to synthesize reference spectral data. In particular, accounting for the inhomogeneity of the deposits greatly improved the match with experimental data. Finally, the theoretical modeling shows that for thicker layers (ca. 20 to 100 μm) of typical organics possessing moderately strong k values, the longwave infrared features are often saturated and better spectral contrast is obtained from the overtone/combination bands in the shortwave infrared.

42 ENGINEERING↗

Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems

Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400–1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8–24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10–50 MHz. Imaging results showed that tungsten filaments yielded 1.1–4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120–200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.

Hsu, Hsun-Chia↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical and traceable atmospheric longwave irradiance data sets with traceability to the International System of units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World InfraRed Standard Group (WISG) not to SI units. In 2013 the Absolute Cavity Pyrgeometer (ACP), [Reda et al., 2012] was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS) developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) [J. Grobner, 2012]. ACP and IRIS are absolute instruments traceable to SI units through the International Temperature Scale ITS-90. Results of six comparisons between ACP and IRIS at different location have shown that the irradiance measured by WISG pyrgeometers is underestimating clear-sky atmospheric longwave irradiance by 2 to 6 W/m 2 [Grobner et al., 2014]. Therefore, once the world reference is established with traceability to SI units the WISG would be corrected then used to calibrate field pyrgeometers with traceability to SI units. The described method below is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Gröbner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Gröbner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

Initial Benchmarks of UV LEDs and Comparisons with White LEDs

The primary goal of this report is to benchmark the initial level of performance of a selection of commercial UV LEDs across all three bands (i.e., UV-A, UV-B, UV-C). To provide the initial performance benchmarks, a test matrix containing 13 different UV LED products was created in association with the LED Systems Reliability Consortium (LSRC). The products in this test matrix were all commercially available as of June 2021, and at least 22 samples of each product were tested. In addition, two common, commercial white LEDs were tested to provide a benchmark against blue-pumped white LEDs. Testing of the samples included electrical performance testing (e.g., current-voltage measurements) and photometric testing in a calibrated integrating sphere capable of measuring devices in the UV-A, UV-B, and UV-C bands. The electrical testing provided insights into the performance of the semiconductor layers in the LEDs, allowing parameters such as the threshold voltage (V th ) and serial resistance (R serial ) of each sample to be determined. The photometric testing provided insights into emission wavelengths, peak shapes, and radiant efficiencies for each sample. Combined, the information from these tests permits the overall device efficiencies to be compared and provides insights into the electrical and optical performance of the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Latest Development to Establish the World Reference with Traceability to SI Units for Measuring the Atmospheric Shortwave and Longwave Irradiance

To date, Interim world reference traceable to blackbody (not sky/atmosphere) is used as a reference noted as a World Infrared Standard Group (WISG). Plan forward: to develop a reference standards traceable to SI InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. Absolute Cavity Pyrgeometer (ACP) developed by NLR is a self-calibrating radiometer using heat substitution to measure the atmospheric longwave irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

14 SOLAR ENERGY↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Portable reflectometer.

Portable integrating sphere reflectometer, describing optical system, construction, etc

Finkel, M. W.↗

Solar radiation calibration facility.

A recently completed calibration facility for the NASA Mississippi Test Site is described. It combines the spectrum of water cooled long arc xenon radiation sources with the integration sphere concept covered by a special barium sulfate diffusely reflecting paint. The sphere is six feet in diameter and completely encompasses the four xenon sources (2.5 kW each) and the five pyranometers under calibration. The sources are contained within the base of the central pedestal and allow the radiation to be emitted into the lower hemisphere. Only through diffuse reflection and multiple scattering is the radiation finally incident upon the test zone, which is in the equatorial plane of the sphere on the top of the pedestal. The sphere is temperature controlled.

Hershey, T. L.↗

Vacuum-ultraviolet reflectometer

Baffle, three-blade chopper, and split spherical mirror transmit alternating dual beam into integrating sphere. Alternating reference and sample beams are detected by high gain photomultiplier and modified logarithmic ratiometer. Device is useful in fusion research, high power laser work, and spectrometer or monochromator construction.

Allen, T. H.↗

Calibration source for remote sensors

The source described was developed as a calibration target for the multispectral scanner (MSS) which was flown on the Earth Resources Technology Satellite A (LANDSAT 1). The wavelength region of interest covered the four (4) MSS bands extending from 0.5 to 1.1 micrometers, although the target was calibrated from 0.32 to 2.5 micrometers. The following characteristics for the target were required: (1) large aperture, sufficient to accommodate an instrument with a 9 inch (23 centimeters(cm)) aperture and 2 1/2 deg field of view (fov), (2) highly diffuse energy from target, (3) high spatial uniformity across aperture area of source, (4) spectrally calibrated in absolute units, (5) stable output over long periods of time (1-2 yrs), and (6) rugged, yet portable enough to be easily transported long distances without detrimental effects on the operational capabilities of the target. Two approaches were considered: a thirty (30) inch (76 cm) diameter integrating sphere with a twelve inch (30.5 cm) exit port, or the use of one hemisphere of a 76 cm sphere in conjunction with a Kodak ektolite screen. The screen has the property of reflecting back uniformly into a well defined area the majority of the light received. After some preliminary trials it seemed that the 76 cm sphere would give the most satisfactory results.

Mclean, J. T.↗

High temperature reflectance of hyperpure slip cast silica

An experimental program to optically characterize hyperpure slip cast silica at elevated temperatures is described. This sintered ceramic material is being used in the development of a reflective heat shield for the Outer Planet Entry Probe. A unique high temperature integrating sphere reflectometer is described and reflectance data in the spectral range 0.23-2.3 micron are presented at temperatures up to 1427 C in air and helium environments. Kubelka-Munk (K-M) scattering and absorptance coefficients (K and S), using the Reichman extension of the K-M theory, are presented as is a unique method of obtaining K and S from the Reichman equations using only reflectance data. The hyperpure slip cast silica material was found to retain its high diffuse reflectance at temperatures up to 1204 C, with slight degradation occurring at higher temperatures.

Dillow, C. F.↗

Optical properties of ion beam textured metals

Copper, silicon, aluminum, titanium and 316 stainless steel were textured by 1000 eV xenon ions from an 8 cm diameter electron bombardment ion source. Simultaneously sputter-deposited tantalum was used to facilitate the development of the surface microstructure. Scanning electron microscopy of the ion textured surfaces revealed two types of microstructure. Copper, silicon, and aluminum developed a cone structure with an average peak-to-peak distance ranging from 1 micron for silicon to 6 microns for aluminum. Titanium and 316 stainless steel developed a serpentine ridge structure. The average peak-to-peak distance for both of these materials was 0.5 micron. Spectral reflectance was measured using an integrating sphere and a holraum reflectometer. Total reflectance for air mass 0 and 2, solar absorptance and total emittance normalized for a 425 K black body were calculated from the reflectance measurements.

Hudson, W. R.↗