Search NASA⌕ Search

SEARCH · Search NASA

Results for “intensifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A photon counting array photometer using an intensified charge coupled device

An array photometer which uses an intensified charge coupled device was developed. This system, the University of Maryland Array Photometer (UMAP), has the ability to discriminate single photoelectron events in real time at a 4 Megahertz rate. The photosensor uses an S-20 photocathode and a Fairchild CCD202 with a 100 by 100 array of separate individual channels. The overall system has demonstrated a noise level which permits single photoelectron discrimination, a scan rate of 400 frames per second, a very linear response, and very low lag. The UMAP system has a very large dynamic range exceeding 10,000 in the photon counting mode. A special technique to extend the dynamic range to 1,000,000 was described. The performance parameters of this system, both in the laboratory and on the telescope were cited. Data from these observations were discussed to illustrate the system sensitivity, which is basically limited by the pixel size in the array, rather than the electrooptics.

Currie, D. G.↗

Photoelectron counting with an image intensifier tube and a self-scanned photodiode array

A self-scanned photodiode array was fiber-optically coupled to an ITT proximity-focused image intensifier tube. It was determined that a single photoelectron event produces 34,000 charge carriers in a photodiode. This charge is only a factor of 2.8 above the rms noise level of the preamplifier used in the tests, but standard charge-sensitive techniques are at least a factor of 12 better. The image tube and photodiode array combination can be packaged in a disk 5.1 cm in diameter and 2.6 cm thick.

Sandel, B. R.↗

Test results on intensified charge coupled devices

CCD imaging arrays were evaluated for a photon counting astronomical sensor. Results show noise corresponding to less than 100 rms electrons and gains of approximately 1000 at 10kV accelerating voltage (greater than 5000 at 25kV). Measured charge transfer efficiencies are in excess of 0.9999, signal saturation levels are as high as 990000 electrons per pixel and peak quantum efficiencies are greater than 75%. Successful proximity focussed intensified charge coupled devices (ICCD) have been fabricated, although problems still exist with contamination and possible structural failures in the CCD's during tube manufacture.

Williams, J. T.↗

Magnifying image intensifier

A magnetically focused image intensifier was improved to increase the usable range of magnification without degradation of image quality. The power requirements of the focusing coils are minimal. The arrangement of the focusing coils reverses the direction of the axial magnetic field distribution between the planes of the photocathode and the phosphor screen.

Vine, J.↗

Electrostatically focused intensified charge coupled devices

Work performed to develop intensified charge coupled devices (ICCDs) is presented. Four ICCDs, containing 100 x 160 arrays, were fabricated. Electron gains up to 3200 at 15 keV were achieved. Photocathode sensitivities ranged from 190 to 410 micro A/lumen. Dark currents varied from 11 nA/sq cm to 37 nA/sq cm. There was serious concern about the reliability of the bonding scheme for ICCDs due to occassional bond failure. Two solutions to this problem were developed. One involved a modification of the existing bonding technique, and the other was the development of a protected bond pad employing a barrier metal between the aluminum metallization and the gold bond wire. An accumulation process was characterized with respect to its most critical variable. This characterization led to the achievement of reproducible spectral response and the discovery and elimination of dark current increase associated with this process.

Walker, J. W.↗

Characteristics of a microchannel plate intensifier

A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

Sandie, W. G.↗

Microchannel intensified electrography

Although electrography is an attractive electronic imaging technique, it suffers at low light levels from limitations imposed by microphotometer and emulsion grain noise. The use of microchannel intensification allows individual photoelectron events to be unambiguously detected and measured, with little loss of achievable resolution. A series of quantitative studies have been conducted to determine the gains in detectivity and SNR yielded by the use of this technique, through microphotometry and computer analysis of images identical or similar to laboratory light sources, by means of both unintensified and microchannel-intensified electromagnetic Schmidt cameras. Applications of the technique to far-UV wide field imaging and nebular spectrograph experiments are described.

Heckathorn, H. M.↗

Interfacing a Two-Stage Image Intensifier Tube to an Echelle Spectrograph

An Echelle spectrograph has been in use at the Marshall Space Flight Center for a number of years. Research has been carried out in the study of the internal motions of ionized gas clouds in the interstellar medium. In order to extend the ability of the spectrograph to allow investigations of the faint outer regions of the gas clouds and to make possible the initiatiion of new research programs dealing with the study of sunspots and the zodiacal light, a two-stage image intensifier tube was incorporated into the instrument. The objective of this work was to interface the image tube with the spectrograph.

Flesch, T. R.↗

Intensified silicon photodiode array detector linearity Application to coherent anti-Stokes Raman spectroscopy

The linearity of an intensified silicon photodiode array multichannel detector is studied with coherent anti-Stokes Raman and other similar signals. Studies with diffuse and focused (spherically and cylindrically) signals resolved apparent saturation problems which limit the dynamic range of the detector. In addition, it has been shown that there is no short-range wavelength (473-532-nm) dependence on this saturation. Theoretical explanations for these phenomena are also included.

Antcliff, R. R.↗

Low temperature multi-alkali photocathode processing technique for sealed intensified CCD tubes

A low temperature photocathode process has been used to fabricate an intensified CCD visual photocathode image tube, by incorporating a thinned, backside-illumined CCD as the target anode of a digicon tube of Hubble Space Telescope (HST) design. The CCD digicon tube employs the HST's sodium bialkali photocathode and MgF2 substrate, thereby allowing a direct photocathode quantum efficiency comparison between photocathodes produced by the presently employed low temperature process and those of the conventional high temperature process. Attention is given to the processing chamber used, as well as the details of gas desorption and photocathode processing.

Doliber, D. L.↗

An intensified CCD detector using the phosphor TPB

The Research Amplifying Imaging Detector consists of a microchannel plate image intensifier with a thin coating (3500-10,000 A) of the phosphor tetraphenyl-butadiene (TPB) on the entrance window to convert EUV radiation to visible, and coupled via a lens to a CCD detector. This design allows great flexibility in selecting the pixel size and field of view, with a simple mechanical design. The phosphor appears to be quite rugged, with no degradation having appeared during several months of testing both in and out of vacuum. Tests have been made at visible and EUV (304 A) wavelengths of the following performance aspects: EUV spectral sensitivity, spatial resolution (both of components and of the system as a whole), noise, linearity, and dynamic range. An improved detector for the Coronal Diagnostic Spectrometer experiment on the Solar Heliospheric Observatory satellite is being presently designed.

Thompson, William T.↗

Application of the intensified CCD to airglow and auroral measurements

New detector technology exemplified by advanced CCD and intensified CCD (ICCD) systems have important advantages for both spectrographic and imaging research. However, to realize the full potential of this new technology, the detector and the optical system as a whole must be considered. It is frequently not enough to simply substitute an ICCD for an earlier detector; rather, to achieve optimum results, the optics must be adapted to the specific detector. Properly designed airglow spectrographs based on the ICCD detector offer the advantages of high throughput over a broad spectral range, precise wavelength stability, low noise, and compactness. Imagers having the wide field and the high sensitivity needed for airglow research are practical as well.

Broadfoot, A. L.↗

Formation of the stable auroral arc that intensifies at substorm onset

Observational evidence that the auroral arc that intensifies at substorm onset is formed on magnetic field lines that map to within about 1 to 2 Re of synchronous orbit, where plasma pressures are about 1 to 10 nPa during the substorm growth phase, is discussed. It is proposed that the arc is formed by a perpendicular magnetospheric-current divergence that results from a strong dawn-to-dusk directed pressure gradient in the vicinity of magnetic midnight. It is estimated that the current divergence is sufficiently strong that a greater than 1 kV field-aligned potential drop is required to maintain ionospheric-current continuity. It is suggested that the azimuthal pressure gradient results from proton drifts in the vicinity of synchronous orbit that are directed nearly parallel to the cross-tail electric field.

Lyons, L. R.↗

Formation of the stable auroral arc that intensifies at substorm onset

In a companion paper, we present observational evidence that the stable, growth-phase auroral arc that intensifies at substorm expansion phase onset often forms on magnetic field lines that map to within approximately 1 to 2 R(sub e) of synchronous. The equatorial plasma pressure is 1 to 10 nPa in this region, which can give a cross-tail current greater than 0.1 A/m. In this paper, we propose that the arc is formed by a perpendicular magnetospheric-current divergence that results from a strong dawn-to-dusk directed pressure gradient in the vicinity of magnetic midnight. We estimate that the current divergence is sufficiently strong that a is greater than 1 kV field-aligned potential drop is required to maintain ionospheric-current continuity. We suggest that the azimuthal pressure gradient results from proton drifts in the vicinity of synchronous orbit that are directed nearly parallel to the cross-tail electric field.

Lyons, L. R.↗

High Speed Intensified Video Observations of TLEs in Support of PhOCAL

The third observing season of PhOCAL (Physical Origins of Coupling to the upper Atmosphere by Lightning) was conducted over the U.S. High Plains during the late spring and summer of 2013. The goal was to capture using an intensified high-speed camera, a transient luminous event (TLE), especially a sprite, as well as its parent cloud-to-ground (SP+CG) lightning discharge, preferably within the domain of a 3-D lightning mapping array (LMA). The co-capture of sprite and its SP+CG was achieved within useful range of an interferometer operating near Rapid City. Other high-speed sprite video sequences were captured above the West Texas LMA. On several occasions the large mesoscale convective complexes (MCSs) producing the TLE-class lightning were also generating vertically propagating convectively generated gravity waves (CGGWs) at the mesopause which were easily visible using NIR-sensitive color cameras. These were captured concurrent with sprites. These observations were follow-ons to a case on 15 April 2012 in which CGGWs were also imaged by the new Day/Night Band on the Suomi NPP satellite system. The relationship between the CGGW and sprite initiation are being investigated. The past year was notable for a large number of elve+halo+sprite sequences sequences generated by the same parent CG. And on several occasions there appear to be prominent banded modulations of the elves' luminosity imaged at >3000 ips. These stripes appear coincident with the banded CGGW structure, and presumably its density variations. Several elves and a sprite from negative CGs were also noted. New color imaging systems have been tested and found capable of capturing sprites. Two cases of sprites with an aurora as a backdrop were also recorded. High speed imaging was also provided in support of the UPLIGHTS program near Rapid City, SD and the USAFA SPRITES II airborne campaign over the Great Plains.

Lyons, Walter A.↗

Investigating Lightning Behavior in Rapidly Intensifying Atlantic Tropical Cyclones

Lightning is a useful tool in forecasting and understanding the behavior of tropical cyclones (TCs). The Geostationary Lightning Mapper (GLM) aboard the GOES-16 geostationary satellite measures a multitude of lightning parameters, such as flash extent density (FED), average flash area (AFA) and optical energy for most of North America, South America, and the Pacific Ocean. GLM has brought about an era of spaceborne measurements to track storms many miles off the coasts and has allowed for the study of lightning throughout a TCs entire lifespan. FED has been found to be indicative of strength and intensification in TCs, but optical energy is a relatively new parameter that has not been studied intensively. This presentation analyzes the relationship between rapid intensification (RI) and GLM optical energy, AFA, and FED in Hurricanes Florence (2018) and Laura (2020). Using a 24-hour time interval in which each storm underwent RI, optical energy was analyzed from the innermost 100 kilometers of the eye and then was averaged for each minute to determine if there was a relationship between optical energy, AFA, FED, and intensification. Optical energy, FED, and AFA spiked just before RI began and then fell as the storms intensified more rapidly. These parameters increased again as intensification slowed slightly, while the optical energy peaks much lower in Hurricane Laura and much higher in Hurricane Florence. While these results show a pattern in lightning in these two TCs, further investigation of parameters like updraft strength and charge separation from microwave imagery during these secondary peaks in which optical energy behaves differently than the first peak may provide further insight as to the behavior of these TCs during RI.

Kiahna Mollette↗

Monocrystal-based microchannel plate image intensifier

A monocrystalline scintillator comprises a monocrystal and an optical plate wherein a first side of the monocrystal is adhered to the optical plate. The monocrystal comprises at least one of a rare earth garnet, a perovskite crystal, a rare-earth silicate, and a monocrystal oxysulphide. The scintillator assembly includes an adhesive adhering the optical plate to the first side of the monocrystal. The adhesive can comprise an ultra-high vacuum compatible adhesive. The adhesive is substantially transparent and has a refractive index matching the optical plate. The scintillator assembly can also include a reflective coating on the second side of the monocrystal. The monocrystalline scintillator assembly can be incorporated in a microchannel plate image intensifier tube to provide improved spatial resolution and temporal response.

Lumpkin, Alex H.↗