Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometer calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Angular diameter measurements of stars

Angular diameters determined with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm. The uniform disk diameters resulting from fits to the visibility observations have rms residuals of order 1 percent for the 800 nm measurements and less than 3 percent for the 450 nm measurements. The improvement over previous observations with this instrument is due to improved data analysis and the use of a wider range of baseline lengths. An analysis of the calibration systematics for the Mark III Optical Interferometer is included. There is good agreement between these measurements and previously published data. The changes in uniform disk diameter between wavelengths of 450 and 800 nm agree with models of stellar atmospheres.

Mozurkewich, D.↗

Analysis of Calibration Errors for Both Short and Long Stroke White Light Experiments

This work will analyze focusing and tilt variations introduced by thermal changes in calibration processes. In particular the accuracy limits are presented for common short- and long-stroke experiments. A new, simple, practical calibration scheme is proposed and analyzed based on the SIM PlanetQuest's Micro-Arcsecond Metrology (MAM) testbed experiments.

instruments↗

SIM PlanetQuest Spectral Calibration Development Unit Beam Combiner

The beam combiner of an astronomical long-baseline interferometer combines the two beams of starlight to form white-light fringes. We describe beam combiner in the SIM PlanetQuest Spectral Calibration Development Unit (SCDU). In addition to forming white light fringes, the beam combiner provides other functions such as separating the light for guiding, fringe tracking, and science measurement. It is designed to function over the optical bandpass 450-950 nm. Coating design is critical to beam combiner as residual dispersion and mismatches affect the ability to accurately measure the position of stars of varying spectral types.

stellar interferometer↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

The minitrack tracking function description, volume 1

The treatment of tracking data by the Minitrack system is described from the transmission of the nominal 136-MHz radio beacon energy from a satellite and the reception of this signal by the interferometer network through the ultimate derivation of the direction cosines (the angular coordinates of the vector from the tracking station to the spacecraft) as a function of time. Descriptions of some of the lesser-known functions operating on the system, such as the computer preprocessing program, are included. A large part of the report is devoted to the preprocessor, which provides for the data compression, smoothing, calibration correction, and ambiguity resolution of the raw interferometer phase tracking measurements teletyped from each of the worldwide Minitrack tracking stations to the central computer facility at Goddard Space Flight Center. An extensive bibliography of Minitrack hardware and theory is presented.

Englar, T. S., Jr.↗

Characterization and operation optimization of large aperture optical interferometers using binary pseudorandom array test standards

Recently, a technique for calibration of the Modulation Transfer Function (MTF) of a broad variety of metrology instrumentation has been established. The technique is based on test samples structured according to binary pseudorandom (BPR) one-dimensional sequences and two-dimensional arrays. The inherent power spectral density of BPR gratings and arrays, has a deterministic white-noise-like character that allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: Functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments working with support of the U.S. Department of Energy on industrialization of the technique. The goal is to develop affordable BPR test samples, application procedures, and data processing software, suitable for thorough characterization of optical interferometers and microscopes, as well as x-ray, electron (scanning and transmission), and atomic force microscopes. We report on the development of BPR array test samples optimized for advanced characterization (including the instrumental MTF and aberrations) and operation optimization of large aperture optical interferometers. We describe the sample fabrication process and tests to verify the compliance to desired surface topography. The data acquisition and analysis procedures for application of the technique for precise focusing of Fizeau interferometer are discussed in detail.

Yashchuk, VV↗

Neural-Net Based Optical NDE Method for Structural Health Monitoring

This paper answers some performance and calibration questions about a non-destructive-evaluation (NDE) procedure that uses artificial neural networks to detect structural damage or other changes from sub-sampled characteristic patterns. The method shows increasing sensitivity as the number of sub-samples increases from 108 to 6912. The sensitivity of this robust NDE method is not affected by noisy excitations of the first vibration mode. A calibration procedure is proposed and demonstrated where the output of a trained net can be correlated with the outputs of the point sensors used for vibration testing. The calibration procedure is based on controlled changes of fastener torques. A heterodyne interferometer is used as a displacement sensor for a demonstration of the challenges to be handled in using standard point sensors for calibration.

Decker, Arthur J.↗

Sensitivity and Calibration of Non-Destructive Evaluation Method That Uses Neural-Net Processing of Characteristic Fringe Patterns

This paper answers some performance and calibration questions about a non-destructive-evaluation (NDE) procedure that uses artificial neural networks to detect structural damage or other changes from sub-sampled characteristic patterns. The method shows increasing sensitivity as the number of sub-samples increases from 108 to 6912. The sensitivity of this robust NDE method is not affected by noisy excitations of the first vibration mode. A calibration procedure is proposed and demonstrated where the output of a trained net can be correlated with the outputs of the point sensors used for vibration testing. The calibration procedure is based on controlled changes of fastener torques. A heterodyne interferometer is used as a displacement sensor for a demonstration of the challenges to be handled in using standard point sensors for calibration.

Decker, Arthur J.↗

The radial velocity search for extrasolar planets

Stars are observed with a ground-based instrument designed to measure small changes in the line-of-sight velocities. The purpose of the observations is to detect large planets by the oscillatory reflex motion they induce on the stars they are orbiting. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. Changes in the line-of-sight velocities are revealed by changes in the Doppler shift of the absorption-line spectra of stars. The scrambling of incident light by an optical fiber and the stability of wavelength calibration by a tilt-tunable Fabry-Perot etalon provide immunity to systematic errors that historically have effected more conventional radial velocity spectrographs. A cross-dispersed echelle spectrograph spatially separates the orders of constructive interference transmitted through the etalon. Selecting several echelle diffraction orders in the vicinity of 4250 to 4750 A, which are imaged on a CCD, about 350 points on the profile of the stellar spectrum are sampled by successive orders of interferometric transmission through the etalon.

Mcmillen, R. S.↗

Digital phase demodulation for low-coherence interferometry-based fiber-optic sensors

In this paper, we describe a digital phase demodulation scheme for low-coherence interferometry-based fiber-optic sensors by employing a simple generation of phase-shifted signals at the interrogation interferometer. The scheme allows a real-time calibration process and offers capability of measuring large variations (up to the coherence of the light source) at the bandwidth that is only limited by the data acquisition system. Finally, the proposed phase demodulation method is analytically derived and its validity and performance are experimentally verified using fiber-optic Fabry–Perot sensors for measurement of strains and vibrations.

47 OTHER INSTRUMENTATION↗

Broadband Stability of the Habitable Zone Planet Finder Fabry–Pérot Etalon Calibration System: Evidence for Chromatic Variation

The comblike spectrum of a white light–illuminated Fabry–Pérot etalon can serve as a cost-effective and stable reference for precise Doppler measurements. Understanding the stability of these devices across their broad (hundreds of nanometers) spectral bandwidths is essential to realizing their full potential as Doppler calibrators. However, published descriptions remain limited to small bandwidths or short time spans. We present an ∼6 month broadband stability monitoring campaign of the Fabry–Pérot etalon system deployed with the near-infrared Habitable Zone Planet Finder (HPF) spectrograph. We monitor the wavelengths of each of ∼3500 resonant modes measured in HPF spectra of this Fabry–Pérot etalon (free spectral range = 30 GHz, bandwidth = 820–1280 nm), leveraging the accuracy and precision of an electro-optic frequency comb reference. These results reveal chromatic structure in the Fabry–Pérot mode locations and their evolution with time. We measure an average drift on the order of 2 cm s{sup –1} day{sup −1}, with local departures up to ±5 cm s{sup –1} day{sup −1}. We discuss these behaviors in the context of the Fabry–Pérot etalon mirror dispersion and other optical properties of the system and the implications for the use of similar systems for precise Doppler measurements. Our results show that this system supports the wavelength calibration of HPF at the ≲10 cm s{sup −1} level over a night and the ≲30 cm s{sup −1} level over ∼10 days. Our results also highlight the need for long-term and spectrally resolved study of similar systems that will be deployed to support Doppler measurement precision approaching ∼10 cm s{sup −1}.

42 ENGINEERING↗

Effect of Near-field Distribution on Transmission Characteristics of Fiber-fed Fabry–Perot Etalons

Fiber-fed etalons are widely employed in advanced interferometric instruments such as gravitational-wave detectors, ultrastable lasers and calibration reference for high-precision spectrographs. We demonstrate that variation in near-field distribution of the feeding fiber would deteriorate the spectrum precision of the fiber-fed Fabry–Perot etalon, especially when precision at the order of 3 × 10{sup -10} or higher is required. The octagonal fiber reinforced with double scrambler could greatly improve the steadiness and uniformness of the near-field distribution. When building wavelength calibrators for sub-m s{sup -1} precision radial-velocity instruments, the double scrambler should be considered meticulously.

47 OTHER INSTRUMENTATION↗

Radiometrically accurate FTS for atmospheric emission observations

The calibration and operational performance of an FTIR-based airborne high-resolution interferometer sounder (HIS) for use in broadband measurements of atmospheric emission at 3.8-16.6 microns are described. The radiometric and wavelength calibration procedures in the laboratory involved the use of reference black bodies at 300 and 245 K and the known wavelength of the HIS HeNe laser (corrected for FOV effects), respectively. The atmospheric verification program included downlooking observations from the NASA U2/ER2 aircraft (where resolving power of 1800-3800 was demonstrated) and uplooking observations from the ground; good agreement with data from balloon-borne radiosondes is obtained, with absolute temperature uncertainties of less than 0.5 K and reproducibilities of 0.1-0.2 K over most of the measurement domain.

Revercomb, H. E.↗

Visible-Infrared Hyperspectral Image Projector

The VisIR HIP generates spatially-spectrally complex scenes. The generated scenes simulate real-world targets viewed by various remote sensing instruments. The VisIR HIP consists of two subsystems: a spectral engine and a spatial engine. The spectral engine generates spectrally complex uniform illumination that spans the wavelength range between 380 nm and 1,600 nm. The spatial engine generates two-dimensional gray-scale scenes. When combined, the two engines are capable of producing two-dimensional scenes with a unique spectrum at each pixel. The VisIR HIP can be used to calibrate any spectrally sensitive remote-sensing instrument. Tests were conducted on the Wide-field Imaging Interferometer Testbed at NASA s Goddard Space Flight Center. The device is a variation of the calibrated hyperspectral image projector developed by the National Institute of Standards and Technology in Gaithersburg, MD. It uses Gooch & Housego Visible and Infrared OL490 Agile Light Sources to generate arbitrary spectra. The two light sources are coupled to a digital light processing (DLP(TradeMark)) digital mirror device (DMD) that serves as the spatial engine. Scenes are displayed on the DMD synchronously with desired spectrum. Scene/spectrum combinations are displayed in rapid succession, over time intervals that are short compared to the integration time of the system under test.

Bolcar, Matthew↗

Laser calibration of the DIII-D coherence imaging system

Here, we describe an in situ calibration technique for Coherence Imaging Spectroscopy (CIS) that measures 2-D images of ion flows on DIII-D. A low power CW diode laser that is tuneable in the range 464-468 nm along with a precision wavemeter (10 –5 nm resolution) is used to characterize the interferometer phase as a function of wavelength in the region of C iii (465 nm) and He ii (468 nm). The interferometer is stabilized both mechanically and thermally to minimize drift during the calibration. Optical stirring and an integration sphere are utilized to obtain spatially uniform calibration images. The quality of the calibration data enables a measurement of phase versus wavelength over approximately 10 fringes of the interferometer. These coefficients can also be related to the geometry of the optics and the birefringent crystal of the interferometer. On DIII-D, the integration sphere with the laser light is inserted into the CIS optical system between shots and the laser image and wavelength are automatically recorded, providing a zero velocity reference

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large aperture Fizeau interferometer commissioning and preliminary measurements of a long x-ray mirror at European X-ray Free Electron Laser

The European XFEL (X-ray Free Electron Laser) is a large facility under construction in Hamburg, Germany. It will provide a transversally fully coherent x-ray radiation with outstanding characteristics: high repetition rate (up to 2700 pulses with a 0.6 ms long pulse train at 10 Hz), short wavelength (down to 0.05 nm), short pulse (in the femtoseconds scale), and high average brilliance (1.6 ⋅ 10{sup 25} (photons s{sup −1} mm{sup −2} mrad{sup −2})/0.1% bandwidth). The beam has very high pulse energy; therefore, it has to be spread out on a relatively long mirror (about 1 m). Due to the very short wavelength, the mirrors need to have a high quality surface on their entire length, and this is considered very challenging even with the most advanced polishing methods. In order to measure the mirrors and to characterize their interaction with the mechanical mount, we equipped a metrology laboratory with a large aperture Fizeau interferometer. The system is a classical 100 mm diameter commercial Fizeau, with an additional expander providing a 300 mm diameter beam. Despite the commercial nature of the system, special care has been taken in the polishing of the reference flats and in the expander quality. We report the first commissioning of the instrument, its calibration, and performance characterization, together with some preliminary results with the measurement of a 950 mm silicon substrate. The intended application is to characterize the final XFEL mirrors with nanometer accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗