Search NASASearch

SEARCH · Search NASA

Results for “interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

An Arbitrary Time Interval Generator Base on Vernier Clocks with 0.67 ps Adjustable Steps Implemented in FPGA

In TDC testing or timing system implementation tasks, it is often desirable to generate signal pulses with fine adjustable time intervals. In delay cell-based schemes, the time adjustment steps are limited by the propagation delays of the cells, which are typically 15 to 20 picoseconds per step and are sensitive to temperature and operating voltage. In this document, a purely digital scheme based on two vernier clocks with small frequency difference generated using cascaded PLL is reported. The scheme is tested in two families of low-cost FPGA and 0.67 and 0.97 picoseconds adjustable steps of the time intervals are achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Exceedance Probabilities and Recurrence Intervals for Extended Power Outages in the United States

This report provides estimates of recurrence intervals and conditional exceedance probabilities for major power outages by U.S. region between 2015 and 2021. Additionally, we provide estimates for grid management, particularly outages caused by California’s public safety power shutoffs (PSPS), and for natural outages caused by major hurricanes. Outage recurrence intervals are the average number of years between outage events, and conditional exceedance probabilities are the likelihoods that a customer who experiences a major power outage will experience an outage exceeding a given duration. Major outage events are those that affect 10,000 or more customers, as defined by the U.S. Department of Energy’s (DOE’s) Electric Emergency Incident and Disturbance Report, called OE-417 (DOE 2020). These results can be applied to determine the likelihood of experiencing long-duration outages, which can be integrated into cost-benefit analyses of resilience solutions and broader energy resilience studies.

Ericson, Sean [National Renewable Energy Laborator

Adaptive Framework for Maintenance Scheduling Based on Dynamic Preventive Intervals and Remaining Useful Life Estimation

Data-based prognostic methods exploit sensor data to forecast the remaining useful life (RUL) of industrial settings to optimize the scheduling of maintenance actions. However, implementing sensors may not be cost-effective or practical for all components. Traditional preventive approaches are not based on sensor data; however, they schedule maintenance at equally spaced intervals, which is not a cost-effective approach since the distribution of the time between failures changes with the degradation state of other parts or changes in working conditions. This study introduces a novel framework comprising two maintenance scheduling strategies. In the absence of sensor data, we propose a novel dynamic preventive policy that adjusts intervention intervals based on the most recent failure data. When sensor data are available, a method for RUL prediction, designated k-LSTM-GFT, is enhanced to dynamically account for RUL prediction uncertainty. The results demonstrate that dynamic preventive maintenance can yield cost reductions of up to 51.8% compared to conventional approaches. The predictive approach optimizes the exploitation of RUL, achieving costs that are only 3–5% higher than the minimum cost achievable while ensuring the safety of critical systems since all of the failures are avoided.

Nunes, Pedro (ORCID:0000000180012172)

Calibration-interval adjustment indicator - A concept

Circuit, when used with decision table, permits relatively unskilled personnel to maintain effective quality control. Design determines required changes in calibration intervals. Interval readings are recorded to nearest integer, making high precision unnecessary. Specific required performance-history information is discussed.

Hedene, P. S.

Systolic and diastolic time intervals in pulsus alternans - Significance of alternating isovolumic relaxation

Systolic and diastolic time intervals in 14 cardiac patients with pulsus alternans revealed significant alternation of preinjection period (PEP), isovolumic contraction time (IVCT), left ventricular ejection time (LVET), ejection time index (ETI), PEP/LVET, and carotid dD/dt with better functional values in the strong beats. Cycle length, duration of electromechanical systole (EMS) and total diastole, i.e., isovolumic relaxation period (IRP) and diastolic filling period (DFP) occurred in 7 out of 8 patients. These diastolic intervals alternated reciprocally such that the IRP of the strong beats encroached upon the DFP of the next (weak) beats.

Spodick, D. H.

Extraterrestrial solar spectrum, 3000-6100 A at 1-A intervals

Standard values of the solar constant and extraterrestrial solar spectrum are reviewed. In the visible and near UV, this listing of average irradiance over 100-A bandwidths at 50-A intervals was found to be inadequate for many applications. A more detailed spectrum obtained from solar scans with a Perkin-Elmer, Model 112 monochromator was found to give sufficient detail. A normalization program was developed to make the Perkin-Elmer curve agree with the standard curve. Values of extraterrestrial solar spectral irradiance at 1-A intervals in the range 3000-6100 A have been derived. The results are presented in tabular form and as spectral charts.

Thekaekara, M. P.

Feedback precision and postfeedback interval duration

Precision of feedback gain was manipulated in a simple positioning task. An optimum was found; an increase in precision past that optimum produced deleterious effects upon rate of acquisition. In a second study, increasing postfeedback interval removed that optimum. The feedback precision effects were then replicated in a timing task. The combined results of the 3 studies were interpreted as supportive of an information-processing approach to the study of postfeedback interval events for simple motor skills. The findings additionally supported specific predictions by Bilodeau and deductions from Adams' 1971 theory of motor learning.

Rogers, C. A., Jr.

Constant-load versus heart rate-targeted exercise - Responses of systolic intervals

Various systolic intervals were measured prior to and during heart rate-targeted bicycle ergometer exercise. There were striking similarities within each matched exercise set for Q-Im, isovolumetric contraction time, preejection period (PEP), and PEP/left ventricular ejection time (LVET). LVET was significantly shorter for rate-targeted exercise. It is concluded that either constant-load or rate-targeted bicycle ergometry may be used with the choice of method determined by the purpose of the protocol, and that systolic intervals (except LVET) should not be much altered owing to the method chosen.

Lance, V. Q.

Decision-related cortical potentials during an auditory signal detection task with cued observation intervals

Cortical-evoked potentials were recorded from human subjects performing an auditory detection task with confidence rating responses. Unlike earlier studies that used similar procedures, the observation interval during which the auditory signal could occur was clearly marked by a visual cue light. By precisely defining the observation interval and, hence, synchronizing all perceptual decisions to the evoked potential averaging epoch, it was possible to demonstrate that high-confidence false alarms are accompanied by late-positive P3 components equivalent to those for equally confident hits. Moreover the hit and false alarm evoked potentials were found to covary similarly with variations in confidence rating and to have similar amplitude distributions over the scalp. In a second experiment, it was demonstrated that correct rejections can be associated with a P3 component larger than that for hits. Thus it was possible to show, within the signal detection paradigm, how the two major factors of decision confidence and expectancy are reflected in the P3 component of the cortical-evoked potential.

Squires, K. C.

Pre- and postflight systolic time intervals during LBNP - The second manned Skylab mission

Before and after the 59 day Skylab 3 flight, the astronauts were stressed with lower body negative pressure (LBNP), and their vectorcardiograms, pneumograms, phonocardiograms, and carotid pulse tracings were monitored together with the intervals of systole. In the immediate postflight period elevations in heart rate and blood pressure were observed in response to -50 mm Hg of LBNP. Postflight abnormalities in the systolic time intervals (STI) at rest and during stress were due to an increase in afterload and a decrease in preload. As blood volume was restored and blood pressure reduced, STI abnormalities persisted as long as one month, suggesting a possible reduction in ventricular contractility and/or a functional impairment to venous return.

Bergman, S. A., Jr.

Systolic time interval data acquisition system. Specialized cardiovascular studies

The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

Baker, J. T.

Deriving winds for hurricanes using short interval satellite imagery

Results are presented for a study program designed to develop a better means of obtaining wind data needed by hurricane forecasters and to determine the optimum space and time resolution of satellite data used to obtain such winds. The discussion covers cloud tracking with an image display and manipulation system and analysis of IR imagery of Hurricane Eloise. It is shown that greater resolution in time and space of satellite imagery made it possible to derive up to six times as many low-level winds in a hurricane case, to eliminate 'bad winds' caused by mistaking cloud growth for cloud motion, and to remove ambiguities that would have caused difficulty in tracking clouds using only the imagery taken at 30-min intervals. It is suggested to use short-interval imagery (less than 10 min) for wind determination for future research in areas of tropical cyclones.

Gentry, R. C.

The benefits of using short-interval satellite images to derive winds for tropical cyclones

During the 1975, 1976 and 1977 North Atlantic hurricane seasons, NOAA/NESS and NASA/GSFC conducted a cooperative program to determine the best resolution and frequency now available from satellite images for deriving winds to study and forecast tropical cyclones. High spatial and temporal resolution satellite imagery made it feasible to provide a large number of lower and upper tropospheric winds which can be obtained by tracking clouds within 650 km of tropical cyclone centers. Up to 10 (5) times as many low-level winds were derived from images spaced at 3 or 7.5 min intervals as from those at 30 min (15 min) intervals. Rapid-scan full-resolution IR and visible images minimized the 'erroneous' winds derived by tracking cloud elements that propagate by growing on one side and dissipating on the other and by tracking repetitive patterns that provided ambiguous indications of direction of movement.

Rodgers, E.

Effect of display update interval, update type, and background on perception of aircraft separation on a cockpit display on traffic information

The concept of a cockpit display of traffic information (CDTI) includes the integration of air traffic, navigation, and other pertinent information in a single electronic display in the cockpit. Concise display symbology was developed for use in later full-mission simulator evaluations of the CDTI concept. Experimental variables used included the update interval motion of the aircraft, the update type, (that is, whether the two aircraft were updated at the same update interval or not), the background (grid pattern or no background), and encounter type (straight or curved). Only the type of encounter affected performance.

Jago, S.

Detection of heavy convective precipitation using rapid interval digital radar and satellite data

A study was carried out to investigate the evolution of thunderstorms with short-interval (5 min) geosynchronous digital satellite data and with digital radar data (12 min interval) in order to determine the potential and limitations of using the satellite data to detect regions of heavy convective precipitation. Initial results indicate that satellite-based estimates of thunderstorm updraft intensity are related to storm precipitation rate as indicated in the digital radar data. The conclusions give support to the effort to use satellite data for detection of heavy convective precipitation, but emphasize the need for high time resolution (5 min) data.

Negri, A. J.

Computation of the intervals of uncertainties about the parameters found for identification

A modeling method to calculate the intervals of uncertainty for parameters found by identification is described. The region of confidence and the general approach to the calculation of these intervals are discussed. The general subprograms for determination of dimensions are described. They provide the organizational charts for the subprograms, the tests carried out and the listings of the different subprograms.

Mereau, P.

An interval logic for higher-level temporal reasoning

Prior work explored temporal logics, based on classical modal logics, as a framework for specifying and reasoning about concurrent programs, distributed systems, and communications protocols, and reported on efforts using temporal reasoning primitives to express very high level abstract requirements that a program or system is to satisfy. Based on experience with those primitives, this report describes an Interval Logic that is more suitable for expressing such higher level temporal properties. The report provides a formal semantics for the Interval Logic, and several examples of its use. A description of decision procedures for the logic is also included.

Schwartz, R. L.