Cardiovascular adaptation to O-G (Experiment 294) - Instrumentation for invasive and noninvasive studies

Many astronauts returning from space have difficulties regulating blood pressure, some to the point of fainting during quiet standing. Experiment 294 was designed to study this and other cardiovascular effects of adaptation to microgravity and to understand the mechanisms behind it. To accomplish this several cardiovascular variables had to be measured accurately. Heart rate, blood pressure, cardiac output (blood pumped by the heart each minute), stroke volume (blood pumped by the heart with each beat), limb flow, limb compliance, heart size and central venous pressure all had to been recorded during various stresses to understand fully the adaptation to space and the readaptation to earth's gravity. Numerous pieces of equipment were used. Some were purpose-built for the Spacelab mission and others were derived from commercial hardware. Developing spaceflight hardware is challenging and costly, but can lead to significant new information in the unique environment of space.

Buckey, Jay C.↗

Development and Feasibility Testing of Image-Guided Minimally Invasive Tissue for Diagnosis Treatment of Benign and Malignant Breast Disease

Dr. Robert Mah and Dr. Stefanie Jeffrey worked on the development of the NASA Smart Probe in its application as a device to measure and interpret physiologic and image-based parameters of breast tissue. To date the following has been achieved: 1 . Choice of candidate sensors to be tested in breast tissue. 2. Preliminary designs for probe tip, specifically use of different tip shapes, cutting edges, and sensor configuration. 3. Design of sonographic guidance system. 4. Design of data extraction and analysis tool using scanned information of images of the breast tissue to provide a higher dimension of information for breast tissue characterization and interpretation. 5. Initial ex-vivo (fruit and tofu) and in-vivo (rodent) testing to confirm unique substance and tissue characterization by the Smart Probe software.

Jeffrey, Stefanie S.↗

Invasion of the Giant X-Ray Bubbles

More bizarre news from the bizarre world of neutron stars: They got dozens of giant X-ray bubbles taller than the Empire State Building forming and popping every second. Yet finding evidence of this bubble blowing was no childish endeavor. It took a team of Berkeley scientists just about all they could muster: three days' worth of observational data and 1,200 hours of number-crunching on the slickest of supercomputers at the Lawrence Livermore National Laboratory (LLNL). Mind you, these are the same powerful computers used to model nuclear reactions and calculate Bill Gates' salary. Neutron stars are already known as the bad boys of the cosmic neighborhood. They are the core remains of exploded stars, with a mass greater than our sun condensed into a sphere no bigger than Manhattan, A teaspoon of its densely-packed surface matter, the analogy goes, would weigh three billion tons back on earth. Its 10 trillion gauss magnetic field could wipe your credit card clean at a distance half-way to the moon. Its intense gravity lures gas from nearby stars, spinning the neutron star to speeds of up to a thousand times a second. But giant X-ray bubbles dancing on the surface? That even freaked out the discoverers. "Early on, I tended to disbelieve what the calculations were telling me," said Richard Klein, who splits his time between Berkeley and LLNL. "The bubbles 'appeared' and I wasn't convinced they were real."

Wanjek, Christopher↗

Non-Invasive, Quantitative, and Remote Detection of Early Radiation Cataracts for Applications in Bio-Astronautics and Bio-Informatics

Human exploration of Mars may be a possibility in the next twenty years. Maintaining good vision is an essential aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts. A compact device based on the technique of dynamic light scattering (DLS) is designed for monitoring an astronaut's ocular health during long-duration space travel. Preliminary data on the simulated effects of ionizing radiation exposure to the ocular tissues of nonhuman animals and results on the sensitivity of DLS over established clinical procedures in investigating cataracts are presented. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An internet web based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. Cataract studies on-board the International Space Station (ISS) will be helpful in designing better protective radiation shields for future space vehicles and space suits.

Ansari, Rafat R.↗

Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

Ueno, Toshiaki↗

Mars Invasion

Currently there are two spacecraft headed to Mars. The Pathfinder mission is expected to land on the red planet on July 4, 1997 and the Global Surveyor will land on September 11, 1997. Both of these missions were under development prior to the August 7th announcement of the possible discovery of early life forms on Mars. Mars will be actively explored by robotics over the next decade. The ultimate exploration will be carried out by humans early in the 21st century. This talk will cover what we know and what we hope to find out in the future about Mars. It will discuss the possible human scenarios for human exploration.

OHandley, Douglas↗

Non-Invasive Evaluation of Corneal Abnormalities Using Static and Dynamic Light Scattering

A preliminary study of corneal abnormalities in intact bovine eyes is presented. Twenty-one eyes were treated with chemicals, cotton swabs, and radial and photo-refractive surgeries. Dynamic and static light scattering was performed as a function of the penetration depth into the corneal tissue. Topographical maps of corneal refractive power from untreated and treated corneas were also obtained using videokeratoscopy and results compared. The ultimate aim is to develop the technique of dynamic light scattering (DLS) for clinical applications in early evaluation of corneal complications after laser-assisted in situ keratomileusis (LASIK) surgeries and other corneal abnormalities.

Ansari, Rafat R.↗

Non-Invasive Method of Determining Absolute Intracranial Pressure

A method is presented for determining absolute intracranial pressure (ICP) in a patient. Skull expansion is monitored while changes in ICP are induced. The patient's blood pressure is measured when skull expansion is approximately zero. The measured blood pressure is indicative of a reference ICP value. Subsequently, the method causes a known change in ICP and measured the change in skull expansion associated therewith. The absolute ICP is a function of the reference ICP value, the known change in ICP and its associated change in skull expansion; and a measured change in skull expansion.

William T Yost↗

Method and Apparatus for Non-Invasive Measurement of Changes in Intracranial Pressure

A method and apparatus for measuring intracranial pressure. In one embodiment, the method comprises the steps of generating an information signal that comprises components (e.g., pulsatile changes and slow changes) that are related to intracranial pressure and blood pressure, generating a reference signal comprising pulsatile components that are solely related to blood pressure, processing the information and reference signals to determine the pulsatile components of the information signal that have generally the same phase as the pulsatile components of the reference signal, and removing from the information signal the pulsatile components determined to have generally the same phase as the pulsatile components of the reference signal so as to provide a data signal having components wherein substantially all of the components are related to intracranial pressure.

William T Yost↗

Non-invasive assessment of otolith formation during development of the Japanese red-bellied newt, Cynops pyrrhogaster

Pre-mated adult female newts and embryos have been flown on the International Microgravity Laboratory-2 (IML-2) Space Shuttle flight in 1994 (Wiederhold et al., 1992b). With the specimens available from this flight, the calcification of otoliths, ulna, radius and backbone of the flown larvae and adult newts were analyzed. The experiments presented here studied the development of the otoliths on the ground. Otoliths of living newts, from embryo to adult, were observed in situ with the application of a new X-ray and bio-imaging analyzer system. For the establishment of this method, newts at different developmental stages were used. An imaging plate temporarily stores the X-ray energy pattern at the bio-imaging analyzer. A latent image on the imaging plate was transformed into a digital time series signal with an image reader. Acquired digital information was computed with the image processor. The processed information was recorded on film with an image recorder, in order to visualize it on an enlargement computed radiograph. To analyze development of the otoliths, photo-stimulated luminescence level was detected by an image analyzer, using transmitted X-ray photons. A single clump of otoconia could first be seen at stage 33. Stage-36 embryos first have distinguishable otoliths, with the utricle in front and saccule behind. Our results show that this X-ray method detects the otoliths equally as well as sectioning. In the newt, the mandibular/maxillary bone formed before the spine. It is suspected that for the newt embryo, living in water, feeding becomes necessary prior to support of the body.

NASA Discipline Neuroscience↗

Incidence of associated events during the performance of invasive procedures in healthy human volunteers

Metabolic investigations often utilize arteriovenous sampling and muscle biopsy. These investigations represent some risk to the subject. We examined 369 studies performed in the General Clinical Research Center between January 1994 and May 2003 for events related to femoral catheterization and muscle biopsies. Incidents were further examined by age (younger: 18-59 yr, n=133; and older: 60-76 yr, n=28). There were no clinically defined major complications associated with either procedure. The incidence of femoral catheter repositioning or reinsertion was higher in the older group (25.5 vs. 9.7%). There was no difference in the incidence of premature removal of catheters, ecchymosis or hematoma, or the persistence of pain after discharge. The occurrence of all incidents did not increase with multiple catheterizations. Muscle biopsy was associated with infrequent ecchymosis or hematoma in both groups (1.1 and 3.6% in younger and older groups, respectively). Both procedures entail a small likelihood of a vagallike response (3.3% overall), resulting in nausea, dizziness, and rarely a loss of consciousness. These results indicate that, in skilled hands and a defined clinical setting, the incidents associated with femoral catheterization and muscle biopsy in healthy volunteers are reasonable and largely controllable.

NASA Discipline Musculoskeletal↗

Non-invasive method of determining diastolic intracranial pressure

A method is presented for determining diastolic intracranial pressure (ICP) in a patient. A first change in the length of a path across the skull of the patient caused by a known change in ICP is measured and used to determine an elasticity constant for the patient. Next, a second change in the length of the path across the patient's skull occurring between systolic and diastolic portions of the patient's heartbeat is measured. The patient's diastolic ICP is a function of the elasticity constant and the second change.

Yost, William T.↗

Non-invasive Optical End-to-End Test of a Large TMA Telescope (JWST) from the Intermediate Focus

The James Webb Space Telescope (JWST) requires testing of the full optical system in a cryogenic vacuum environment before launch. Challenges with the telescope architecture and the test environment lead to placing removable optical test sources at the Cassegrain intermediate focus of the Telescope. The Science Instrument suite will be used to align the telescope and to verify the wavefront error. The Science Instruments capture test images that are analyzed using focus diverse phase retrieval. The wavefront sensing algorithms have the large dynamic range required to measure the relatively small wavefronts of interest in the presence of the large aberrations resulting from the off-axis source locations at the intermediate focus. These inherent aberrations of the off-axis design are removed analytically from the measured data. The test design and in-situ wavefront sensing process enables a number of tests to verify the alignment and optical quality of the system.

Whitman, Tony↗

Wireless sensing system for non-invasive monitoring of attributes of contents in a container

A wireless sensing system monitors the level, temperature, magnetic permeability and electrical dielectric constant of a non-gaseous material in a container. An open-circuit electrical conductor is shaped to form a two-dimensional geometric pattern that can store and transfer electrical and magnetic energy. The conductor resonates in the presence of a time-varying magnetic field to generate a harmonic response. The conductor is mounted in an environmentally-sealed housing. A magnetic field response recorder wirelessly transmits the time-varying magnetic field to power the conductor, and wirelessly detects the harmonic response that is an indication of at least one of level of the material in the container, temperature of the material in the container, magnetic permeability of the material in the container, and dielectric constant of the material in the container.

Woodard, Stanley E.↗

The Space Microbe Invasion: To Eat or Not to Eat

Objective: To investigate how different cleaning agents sanitize an assortment of vegetables and fruits for ~nsumption on board the International Space Station (ISS). -Description: This laboratory investigation will have students testing different cleaning agents on a variety of vegetables and fruits that can be grown on board the ISS. Students will determine which cleaning agent most effectively lowers the number of bacteria on a variety of vegetables and fruits. This lab will also lend itself to investigations dealing with pH and its' role in lowering bacterial counts. In addition, students will figure out the correct balance between plant architecture and effectiveness of sanitizing these surfaces to achieve lower bacteria counts. This will be determined based on swabbed bacteria samples later grown on a Petri dish.

Munoz, Angela↗

Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector using Non-Invasive Laser, Optical and X-ray Techniques

The spray characteristics of a Liquid-Liquid Double Swirl Coaxial Injector were studied using noninvasive Optical, Laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler Particle Analysis characterized droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, x-ray radiographs allowed for investigations of sheet thickness and breakup length to be quantified for different recess exits and inlet pressures. Finally Computed Tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

Radke, C. R.↗