Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverter availability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Effects of Atmospheric Models on the Estimation of Infrasonic Source Functions at the Source Physics Experiment

We invert infrasound signals for an equivalent seismoacoustic source function using different atmospheric models to produce the necessary Green’s functions. The infrasound signals were produced by a series of underground chemical explosions as part of the Source Physics Experiment (SPE). In a previous study, we inverted the infrasound data using so-called predictive atmospheric models, which were based on historic, regional-scaled, publicly available weather observations interpolated onto a 3D grid. For the work presented here, we invert the same infrasound data, but using atmospheric models based on weather data collected in a time window that includes the approximate time of the explosion experiments, which we term postdictive models. We build two versions of the postdictive models for each SPE event: one that is based solely on the regional scaled observations, and one that is based on both regional scaled observations combined with on-site observations obtained by a weather sonde released at the time of the SPE. We then invert the observed data set three times, once for each atmospheric model type. We find that the estimated seismoacoustic source functions are relatively similar in waveform shape regardless of which atmospheric model that we used to construct the Green’s functions. However, we find that the amplitude of the estimated source functions is systematically dependent on the atmospheric model type: using the predictive atmospheric models to invert the data generally yields estimated source functions that are larger in amplitude than those estimated using the postdictive models.

54 ENVIRONMENTAL SCIENCES↗

Electric Drive Technology Trends, Challenges, and Opportunities for Future Electric Vehicles

The transition to electric road transport technologies requires electric traction drive systems to offer improved performances and capabilities, such as fuel efficiency (in terms of MPGe, i.e., miles per gallon of gasoline-equivalent), extended range, and fast-charging options. The enhanced electrification and transformed mobility are translating to a demand for higher power and more efficient electric traction drive systems that lead to better fuel economy for a given battery charge. To accelerate the mass-market adoption of electrified transportation, the U.S. Department of Energy (DOE), in collaboration with the automotive industry, has announced the technical targets for light-duty electric vehicles (EVs) for 2025. This article discusses the electric drive technology trends for passenger electric and hybrid EVs with commercially available solutions in terms of materials, electric machine and inverter designs, maximum speed, component cooling, power density, and performance. Additionally, the emerging materials and technologies for power electronics and electric motors are presented, identifying the challenges and opportunities for even more aggressive designs to meet the need for next-generation EVs. Some innovative drive and motor designs with the potential to meet the DOE 2025 targets are also discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Positive-Sequence Phasor Modeling of Droop-Controlled, Grid-Forming Inverters with Fault Current Limiting Function

Traditional positive-sequence phasor models of droop-controlled, grid-forming inverters do not have the fault current limiting function. During a short-circuit fault the model generates unrealistic high fault current making the simulation results less practical. This paper develops a fault current limiting function for the positive-sequence phasor model of droop-controlled, grid-forming inverters, which can effectively limit the inverter output current at the predefined maximum during faults. A user-written model has been developed for the commercially-available software Siemens/PTI PSS/E. Fault studies on a modified IEEE 39-bus system with all grid-forming inverters verify the effectiveness of the developed fault current limiting function. The proposed model can be used to evaluate how the limited fault currents of droop-controlled, grid-forming inverters impact the bulk power system transient stability under fault conditions.

Du, Wei↗

System-Level Efficiency Study of Modular DC/DC and Fuel Cell Stack Series–Parallel Configurations

This paper presents a system-level efficiency study of modular DC/DC converter and fuel cell stack configurations under series, parallel, and series–parallel connections. The investigation considers selected DC/DC converter topologies, including isolated and non-isolated architectures, boost, non-inverting buck-boost, and resonant converters, integrated with commercially available fuel cell stacks, including the Accelera FCE150, Ballard FCgen-HPS, and Toyota TFCM2. DC/DC converter modules are evaluated in modular configurations rated at 60 kW and 90 kW and two distinct output voltage ranges, specifically 580–730V and 780–930V, examining how different interconnection schemes impact overall system efficiency. The converters are evaluated under full load (100%), partial load (66%), and light load (33%) conditions, providing a comprehensive assessment of efficiency and operational characteristics across varying power demands. Approximately two-thousand efficiency data points are obtained from laboratory prototype–level component measurements and validated design evaluations across multiple converter topologies, modular configurations, voltage ranges, and load conditions, providing a robust dataset for comparative system-level efficiency analysis. The results highlight the effects of modularity and topology selection on system-level efficiency, offering a “playbook” framework for designers to select appropriate DC/DC converter arrangements and fuel cell stack connections for series, parallel, or hybrid configurations based on efficiency considerations.

DC/DC↗

Adjoint Waveform Tomography for Crustal and Upper Mantle Structure of the Middle East and Southwest Asia for Improved Waveform Simulations Using Openly Available Broadband Data

Here we present a new model of radially anisotropic seismic wavespeeds for the crust and upper mantle of a broad region of the Middle East and Southwest Asia (MESWA) derived from adjoint waveform tomography. The new model enables fully 3D simulations of complete three-component waveforms and provides improved fits that were not possible with previous models. We inverted over 32,000 waveforms from 192 earthquakes recorded by over 1000 openly available broadband seismic stations from permanent and temporary networks in the region with highly uneven coverage. Inversion iterations proceeded from the period band 50–100 s in six stages and 54 total iterations reducing the minimum period to 30 s. Our final model, MESWA, improves waveform fits compared to the starting and other models for both the data used in the inversion and an independent validation set of 66 events. Restitution tests indicate that the model resolves features in the central part of the model to depths of about 150 km. The new model reveals tectonic features imaged by other studies and methods but in a new holistic model of anisotropic shear and compressional wavespeeds (V S and V P , respectively) covering a larger domain with smaller scale length and amplified features. Examples include low crustal V S in the Tethyan belt and low mantle VS following divergent (Gulf of Aden, Red Sea) and transform (Dead Sea fault) margins of the Arabian plate. Low V S is imaged below Cenozoic volcanic centers of the Mecca–Madina–Nafud Line, Arabian Peninsula, and the Türkiye–Iran border region. Elevated V S tracks Makran subduction under southeast Iran with near vertical dip. MESWA could be used as a starting model for further improvements, say, using waveforms from in-country seismic networks that are not currently openly available and/or smaller-scale studies targeting a shorter period. The model could be used to improve earthquake hazard studies and nuclear explosion monitoring.

58 GEOSCIENCES↗

Adjoint Waveform Tomography for Crustal and Upper Mantle Structure the Middle East and Southwest Asia for Improved Waveform Simulations Using Openly Available Broadband Data

We present a new model of radially anisotropic seismic wavespeeds for the crust and upper mantle of a broad region of the Middle East and Southwest Asia (MESWA) derived from adjoint waveform tomography. We inverted waveforms from 192 Global Centroid Moment Tensor earthquakes (MW 5.5-7.0) recorded by over 1000 openly available broadband seismic stations from permanent and temporary networks in the region. Spatial coverage of the available data is highly uneven due to earthquakes clustered along plate boundaries and sparse coverage of open seismic networks in the region. We considered three possible starting models: the SPiRaL global model (Simmons et al., 2021); MEC-1 (Kaviani et al., 2020); and CSEM2.0 (Noe et al., 2023). Because the SPiRaL model provides good fits to the observed waveforms measured by the time-bandwidth product of selected windows in several period bands, provides all the necessary parameters and covers the entire domain we used it for the starting model with the period band 50-100 seconds. Inversion iterations proceeded using time-frequency phase misfits in six stages and 54 total iterations reducing the minimum period to 30 seconds. Our final model, MESWA, provides improved waveform fits compared to the starting model for both the data used in the inversion and an independent validation data set of 66 events. Two metrics of waveform fit (the time-frequency phase misfit used in the optimization and normalized L2 misfit) were both reduced by nearly 60% for both data sets and MESWA provides significantly larger misfit reductions relative to the SPiRaL model than the MEC-1 or CSEM models. We also find that MESWA provides a larger time-bandwidth product of selected windows indicating that more information content of the observed waveforms is explained by MESWA than the other models. Our new model reveals tectonic features imaged by other studies and methods but in a new holistic model of shear and compressional wavespeeds (v S and v P , respectively) with anisotropy covering the crust and uppermost mantle of a larger domain. MESWA has smaller scale-length features and tends to sharpen some features relative to the SPiRaL starting model. Examples include: low crustal v S in the TurkishIranian Plateau, Zagros Mountains, Afghan Central Blocks and Sulaiman Fold Belt; low mantle vSfollowing divergent (Gulf of Aden, Red Sea) and transform (Dead Sea Fault) margins of the Arabian Plate; low and high v S in the mantle beneath the Arabian Shield and Platform, respectively. Low vS is imaged below Cenozoic volcanic centers of the Arabian Peninsula, the so-called Mecca-Madina-Nafud (MMN) Line. Positive anisotropy (v SH > v SV ) is inferred for asthenospheric depths across the region except where up/downwelling may influence fabric alignment (e.g. Afar, Red Sea, Arabian Shield). Elevated vS tracks Makran subduction under southeast Iran. MESWA resembles the SPiRaL model in its long-wavelength structure, but enhances shorter wavelengths features on the order of 200 km and smaller. The resulting model could be used for as a starting model for further improvements, say using waveforms from in-country seismic networks that are not openly available or smaller-scale studies targeting shorter period waveforms. The model also could be used for source characterization and moment tensor inversion to improve earthquake hazard studies and nuclear explosion monitoring.

58 GEOSCIENCES↗

PV Generation and Load Forecasting for Adjuntas PR Community Microgrids

Existing frameworks to forecast time-series photovoltaic (PV) output power and consumer load for microgrid operations and controls assume a near-continuous availability of real-time input features from the field assets such as PV inverters, energy meters, and weather station. These incoming data points are used to periodically retrain models and update forecast snapshots over a moving horizon window, be it one hour-ahead, one-day ahead, or one-week ahead. However, such frameworks are not resilient to disruptions in data availability caused by losses in communications between the field sensors and data loggers. Hence, there is a need for programs that assume no availability of real-time microgrid asset data and still make reliable forecasts that can be used for decision-making. Such programs would be apt to function in extreme weather events such as hurricanes and would use lightweight recursive time-series models to independently forecast solar irradiance and ambient temperature, then compute PV power from those forecasts, as well as independently forecast consumer load. The codebase performs forecasting for the scenario of when the microgrid does not have a reliable access to forecasts or real-time observations of solar irradiance (I) and ambient temperature (AT) and load (Load) to be able to adequately forecast, in real-time, the PV power production or a business' load. In this case, using historical values of PV power and load, a univariate forecasting of generation and consumption are respectively made. The use-case in particular has two sub-scenarios: one, a normal 7-day ahead forecast where the unavailability of real-time data is assumed due to infrastructure issues such as loss of communication or sensor maintenance or service downtimes. Whereas a hurricane-caused unavailability of real-time data requires a second model trained specifically on historical hurricane days to be able to capture the extreme day behavior of generation in particular, and load if applicable. A gradient boosted regression tree comprises an ensemble of additive models that map between the input of historical values (be it irradiance, temperature, or load) and their corresponding output forecasts of a given horizon such that the individual learner predictions are summed up over the total number of such learners in the ensemble to produce an aggregate forecast. A weighting mechanism is applied to the training data in each iteration, where actual and forecast values are compared to penalize incorrect forecasts by increasing the weight and reducing it to reward correct forecasts. The code's benefits are that it: (a) accounts for a contingency where communication loss renders newly measured real-time data unavailable for model tuning and snapshot updates; (b) presents blind forecasting that recursively determines the next time-step value in a horizon using the forecast of the same attribute from a prior step; and (c) employs lightweight models that, once trained, can reliably generalize for different horizons, which make them suitable for enhancing the resilience of field microgrids prone to extreme events that encounter disruptions to data availability.

Sundararajan, Aditya [Oak Ridge National Laborator↗

Efficient Topology Assessment for Integrated Transmission and Distribution Network with 10,000+ Inverter-based Resources

The renewable energy proliferation calls upon the grid operators and planners to systematically evaluate the potential impacts of distributed energy resources (DERs). Considering the significant differences between various inverter-based resources (IBRs), especially the different capabilities between grid-forming inverters and grid-following inverters, it is crucial to develop an efficient and effective assessment procedure besides available co-simulation framework with high computation burdens. This paper presents a streamlined graph-based topology assessment for the integrated power system transmission and distribution networks. Graph analyses were performed based on the integrated graph of modified miniWECC grid model and IEEE 8500-node test feeder model, high performance computing platform with 40 nodes and total 2400 CPUs has been utilized to process this integrated graph, which has 100,000+ nodes and 10,000+ IBRs. The node ranking results not only verified the applicability of the proposed method, but also revealed the potential of distributed grid forming (GFM) and grid following (GFL) inverters interacting with the centralized power plants.

Graph Analysis, Topology evaluation, Infrastructur↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

Bragg coherent diffraction imaging by simultaneous reconstruction of multiple diffraction peaks

Bragg coherent diffractive imaging (BCDI) is a non-invasive microscopy technique that can visualize the morphology and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. While BCDI has been successfully applied in various studies of materials, it is less successful for highly-strained crystals. Specifically, it is difficult to correctly reconstruct the electron density of a highly-strained object using conventional phase retrieval algorithms. Although various algorithms have been developed to overcome this challenge, most of them require a priori knowledge that is not always available in practice. Here we report on a new phase retrieval workflow that can invert diffraction patterns from multiple Bragg peaks simultaneously. The new workflow is explored via simulated diffraction from crystals with various strain conditions. Furthermore, reconstructions from the new workflow consistently demonstrate more accurate electron density maps, in comparison with the conventional method. For highly-strained crystals, the new workflow improves the reliability and consistency of BCDI phase retrieval significantly.

36 MATERIALS SCIENCE↗

Microgrid-Integrated Solar-Storage Technology (MISST)

Microgrid-Integrated Solar-Storage Technology (MISST) project addresses availability and variability issues inherent in the solar photovoltaic (PV) technology by utilizing smart inverters for solar PV/battery storage and working synergistically with other components within a microgrid community. A key contribution of this project to the state-of-the-art is the practical implementation of seamless and coordinated control between the previously developed and DOE-funded Microgrid Master Controller (MMC) and the MISST controller, the latter is a dedicated solar-storage controller to manage high penetration of solar PV and energy storage systems.

14 SOLAR ENERGY↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Variable Resource Resilience: How Systems Experience Increased Resilience from Variable and Hybrid Resources

Variable resources like wind and solar are often seen as detriments to system resilience rather than benefits because they may not be available with the capacities or services required during a high-impact low-frequency (HILF) event, whether that is a physical threat, natural disaster, or cyber attack. However, resilience goals and metrics are inadequate for electric energy delivery systems with inverter-based resources. Examination of this topic reveals that renewable resources are well suited to combat many resilience hazards due to local resource availability. Metrics that demonstrate the resilience value of variable resources are presented and categorized for resource (wind, solar, storage, hybrid) and installation type (bulk utility scale, behind-the-meter, front-of-the-meter, isolated). Distributed and hybrid systems can further enhance resilience benefits my maximizing resource potential for a locality. A case study demonstrating quantitative resilience benefits from wind alone is provided for St. Mary's, AK, which concludes that hundreds of thousands of dollars are saved by the addition of a wind turbine in the face of realistic fuel shortage and extreme winter weather scenarios.

17 WIND ENERGY↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗