Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverter integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Highly Integrated Wide Bandgap Power Module for Next Generation Plug-In Vehicles (Final Report)

Wide bandgap devices are key enablers for high power density traction inverters. A highly integrated wide bandgap (WBG) power module enables higher temperature operation, higher inverter efficiency and overall smaller die area with the same power delivery. However, it requires careful design of the power module to take advantage of all the superior material properties that silicon carbide (SiC) provides over conventional silicon (Si) Insulated Gate Bipolar Transistor (IGBT) based design. This project developed an efficient and densely packed SiC power module for an automotive traction inverter application. Extensive study was performed to select the best performing SiC die considering a wide range of temperature variation, suitability to integrate into target packaging, robust body diode performance and overall high electrical efficiency. Multiple design ideas were explored to achieve lower stray inductance for both power loop and signal loop, uniform current distribution, compact form factor, and very high thermal performance. The final power module package includes all six inverter switches in the same module (six-pack) with die sintered at both bottom and top surfaces utilizing high performance substrate to achieve high electrical and thermal performance. Two power module variants were developed using 900 V and 1200 V devices for operating at two different high voltage levels (> 600 V HV battery). Both power modules were comprehensively characterized, and high efficiency operation of the inverter was confirmed through analysis. Finally, a complete functional inverter was built with the 1200V power modules using other essential components (HV capacitors, gate driver board, controller board, current sensor, connectors etc.) and tested using GM’s standard test procedure. There are several challenges associated with adopting WBG devices for high voltage operation. In order to assess and mitigate those challenges, GM and subrecipients of this project have conducted multiple detailed studies. This includes phase current reconstruction using integrated Rogowski coil, device junction temperature estimation using on-state gate resistance, modeling and testing the effect of high voltage and fast switching on motor insulation and bearings, partial discharge inception voltage measurement under different environmental conditions. Findings of all these studies are summarized in this report.

33 ADVANCED PROPULSION SYSTEMS↗

EMT-TS Hybrid Simulation for Large Power Grids Considering IBR-Driven Dynamics

The escalating integration of inverter-based resources (IBRs) poses new challenges to power systems by introducing fast dynamics with higher frequencies, which may need to be simulated by an electromagnetic transient (EMT) program. As an alternative to conducting EMT simulations for the entire system, which is typically time consuming, hybrid simulation between EMT and phasor-domain transient stability (TS) can greatly reduce the computational burden while preserving the detailed fast dynamics in the EMT zone. This paper establishes an EMT-TS hybrid simulation platform using open-source tools, specifically ParaEMT, GridPACK, and HELICS, which are the EMT simulator, TS simulator, and interface framework, respectively. Case studies on the 240-bus Western Electricity Coordinating Council (WECC) system demonstrate that the developed ParaEMT-HELICS-GridPACK hybrid simulator can accurately capture both slow electromechanical and fast IBR-driven dynamics with a 2.4x speedup.

electromagnetic transient↗

Impact of Inverter-Based Resources on Grid Protection: A Review of Negative-Sequence Current Generation

The increasing integration of inverter-based resources (IBRs) in power grids poses challenges to traditional protection systems, primarily due to their different fault current signatures compared to conventional synchronous generators. Unlike synchronous generators whose fault response is dictated by their physical design, IBRs exhibit a wide range of fault characteristics due to manufacturer-specific control algorithms and settings. This dependence on proprietary control schemes makes modeling IBR behavior during faults significantly more complex, especially considering the rapid evolution of inverter technology and the diverse control strategies employed. While much research has focused on the positive-sequence current injections of IBRs during symmetrical faults, the understanding of negative-sequence current generation during non-symmetrical faults remains limited. This report provides an overview of current research on IBRs' negative-sequence current generation during unbalanced faults and its impact on protection schemes based on negative-sequence components. It covers both type III wind turbines and full-size converter-based IBRs. Additionally, this report reviews strategies for grid-forming controlled inverters to generate negative-sequence current during unbalanced faults, in addition to grid-following controlled ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integral inverter/battery charger for use in electric vehicles

The design and test results of a thyristor based inverter/charger are discussed. A battery charger is included integral to the inverter by using a subset of the inverter power circuit components. The resulting charger provides electrical isolation between the vehicle propulsion battery and ac line and is capable of charging a 25 kWh propulsion battery in 8 hours from a 220 volt ac line. The integral charger employs the inverter commutation components at a resonant ac/dc isolated converter rated at 3.6 kW. Charger efficiency and power factor at an output power of 3.6 kW are 86% and 95% respectively. The inverter, when operated with a matching polyphase ac induction motor and nominal 132 volt propulsion battery, can provide a peak shaft power of 34 kW (45 ph) during motoring operation and 45 kW (60 hp) during regeneration. Thyristors are employed for the inverter power switching devices and are arranged in an input-commutated topology. This configuration requires only two thyristors to commutate the six main inverter thyristors. Inverter efficiency during motoring operation at motor shaft speeds above 450 rad/sec (4300 rpm) is 92-94% for output power levels above 11 KW (15 hp). The combined ac inverter/charger package weighs 47 kg (103 lbs).

Thimmesch, D.↗

A Fast and Accurate Transient Stability Assessment Method Based on Deep Learning: WECC Case Study

Transient stability is one of the critical aspects of power system stability assessment. The increasing integration of inverter-based resources and the retirement of conventional synchronous generators result in the decreasing system inertia and growing complexity of system operating conditions. Using a few selected typical operating conditions cannot guarantee system transient stability in all operating conditions, and the time-domain simulation of all operating conditions requires tremendous time and is often infeasible. This paper proposes a more efficient transient stability assessment method based on deep learning. The binary search method is used to determine the critical clearing time (CCT) in creating training databased by time-domain simulation. This method is fast and accurate with 1 ms resolution. The buses whose CCTs are lower than 200 ms are considered critical buses. Buses close to each other are grouped based on their mutual admittance matrix to reduce the search space of the critical buses. This paper also proposes the generator feature normalization based on the physical model. Case study on the reduced 240-bus WECC system model demonstrates that the proposed method can predict CCT accurately and efficiently.

critical clearing time↗

Transmission Data-Driven User-Defined Model for Inverter-based and Conventional Power Plants

Recent events in Odessa [1], [2] have shed light on the complexities of integrating large Inverter-Based Resource (IBR) plants with the transmission system, prompting NERC to stress continuous performance monitoring by transmission operators. Challenges such as plant control updates, IBR model revisions, Phase-locked loop loss of synchronism, and protection events have been identified, underscoring the need for enhanced monitoring protocols by regulatory bodies. The recent FERC 901 order underscores the importance of accurate data exchange regarding IBRs for reliability studies. However, limited access to IBR plant-related data hampers effective decision-making for transmission operators (TOP). This paper proposes a method for constructing data-driven User-Defined dynamic Models (UDM) for power plants for validating multiple-event data using field measurements from interconnection bus locations. The problem is formulated as a power plant model identification problem and a multi-task learning approach under partial input observability assumptions is proposed in this work. This approach aims to predict aggregated responses of conventional and IBR power plants during various dynamic physical events which is useful for planning studies under diverse disturbance conditions. Ultimately, this methodology emphasizes the importance of plant visibility to operators in addressing power system challenges, facilitating improved planning and operational studies.

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

Inverted thermal conversion - GaAs, a new alternative material for integrated circuits

A new type of GaAs is developed which exhibits inverted thermal conversion (ITC); i.e., it converts from conducting to semiinsulating upon annealing at about 850 C. In device fabrication, its low resistivity prior to high-temperature processing differentiates ITC GaAs from the standard semiinsulating GaAs. The ITC characteristics are obtained through control of the concentration of the midgap donor EL2 based on heat treatment and crystal-growth modification. Thus EL2 does not exist in the conducting state of ITC GaAs. Conversion to the semiinsulating state during 850 C annealing is caused by the formation of EL2.

Lagowski, J.↗

UNIFI's Grid-Forming (GFM) Inverter Reference Design: A Tutorial on Modeling, Control, and Experimental Implementation of GFM Inverters

The UNIFI Consortium's tutorial on grid-forming (GFM) inverters provides a comprehensive guide to the modeling, control, and experimental implementation of GFM inverters. As the integration of renewable energy accelerates, the transition from traditional grid following (GFL) to GFM inverters is crucial to ensure stable and sustainable power systems. This document outlines a reference design for three-phase and single-phase GFM inverters developed at the University of Texas at Austin. The tutorial also provides step-by-step guidance for accessing and using UNIFI’s GitHub repository, enabling users to design, build, and test GFM inverters efficiently. By fostering collaboration and equipping users with accessible resources, this initiative aims to drive widespread adoption of GFM technology across academia, utilities, and industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models [Slides]

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

14 SOLAR ENERGY↗

Integrated Coordination of Voltage Regulators with Distributed Cooperative Inverter Control in Systems with High Penetration of DGs

Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.

coordinated voltage regulator control↗

A Risk Assessment Framework for Cyber-Physical Security in Distribution Grids with Grid-Edge DERs

Integration of inverter-based distributed energy resources (DERs) is reshaping the landscape of distribution grids to fulfill the socioeconomic, environmental, and sustainability goals. Addressing the technological challenges of DER grid integration requires an adaptive communication layer for efficient DER management and control. This transition has given rise to a cyberphysical system (CPS) architecture within the distribution system, causing new vulnerabilities for cyberphysical attacks. To better address potential threats, this paper presents a comprehensive risk assessment framework for cyberphysical security in distribution grids with grid-edge DERs. The framework incorporates a detailed CPS model accounting for dynamic DER characteristics within the distribution grid. It identifies vulnerabilities in DER communication systems, models attack scenarios, and addresses communication latency crucial for inverter control timescales. Subsequently, the quantification of attack impacts employs an attack probability model including both the vulnerability and criticality of cyber components. The proposed risk assessment framework was validated through testing on the modified IEEE 13-node and 123-node test feeders.

cyberattack↗

A Unified Off-Board Charger for Three-Phase Inductive and Single-Phase Conductive EV Charging

This paper presents a unified off-board charger integrating a three-phase inductive power transfer (IPT) system and a single-phase conductive (plug-in) charger for electric vehicles (EVs). The proposed charger shares a high-frequency inverter and an integrated magnetic structure that enables three operating modes: conductive charging, inductive charging, and simultaneous charging. The transmitter coils for the three-phase IPT and the high-frequency transformer windings for the conductive charger are arranged on a common ferrite pad while maintaining magnetic decoupling between the two power transfer paths. The proposed unified architecture effectively increases charger utilization and power density without a proportional increase in cost, weight, or volume. Finite-element analysis using Ansys Maxwell confirms negligible coupling between the inductive and conductive coils, and the extracted parameters are employed in PLECS simulations to verify the independent operation of each charging mode.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Operational characteristics of a 200 C LC parallel resonant circuit

Research efforts are currently underway at the NASA Lewis Research Center to design and demonstrate an inverter capable of operating with a baseplate temperature of 200 C. In support of this project, various electrical components including capacitors, inductors, transformers, cables, and semiconductor switches are being developed or evaluated for integration into the inverter. In this work, a parallel LC resonant circuit was constructed and evaluated under simultaneous electrical and thermal stressing. The tests were performed in the temperature range of 25 to 200 C with an applied voltage of up to 90 V, 20 kHz. The individual components were comprised of high temperature film capacitors and powder core inductors developed in-house. The circuit was characterized in terms of the component currents and case temperatures as well as frequency of resonance as a function of applied bias and temperature. The results obtained, which have indicated good functional stability up to 200 C, are presented and discussed.

Baumann, Eric D.↗

A State-Space Model of an Inverter-Based Microgrid for Multivariable Feedback Control Analysis and Design

In this work, a synchronous model for grid-connected and islanded microgrids is presented. The grid-connected model is based on the premise that the reference frame is synchronized with the AC bus. The quadrature component of the AC bus voltage can be cancelled, which allows to express output power as a linear equation for nominal values in the AC bus amplitude voltage. The model for the islanded microgrid is developed by integrating all the inverter dynamics using a state-space model for the load currents. This model is presented in a comprehensive way such that it could be scalable to any number of inverter-based generators using inductor–capacitor–inductor (LCL) output filters. The use of these models allows designers to assess microgrid stability and robustness using modern control methods such as eigenvalue analysis and singular value diagrams. Both models were tested and validated in an experimental setup to demonstrate their accuracy in describing microgrid dynamics. In addition, three scenarios are presented: non-controlled model, Linear-Quadratic Integrator (LQI) power control, and Power-Voltage (PQ/Vdq) droop–boost controller. Experimental results demonstrate the effectiveness of the control strategies and the accuracy of the models to describe microgrid dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Scalable Emulation of Hydropower Using Real-Time Hardware-in-the-Loop

This presentation covers Motivation: (1) With the increased grid integration of inverter-based resources, hydropower plays a crucial role in maintaining the bulk power system reliability and resilience; and (2) A more dynamic response and new control designs are required to meet the grid requirements. To evaluate any modification, control-prototyping, performance validation and de-risking grid integration of hydropower, a high-fidelity environment is required. Also covers Objectives: (1) To develop data-driven emulation of hydropower using hardware-in-the-loop for different size, types of hydro plants; and (2) To characterize hardware and obtain accurate dynamic response for shaft speed, torque, and power. Provide a mechanical power interface with emulated dynamics of a hydro-turbine shaft that can be coupled to electrical generators for mechanical and electrical PHIL.

electrical↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗