Search NASA⌕ Search

SEARCH · Search NASA

Results for “iterative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Eigenmode analysis of the ITER ICRF antenna plug and electrical solution to the grounding of the antenna

The excitation of resonant modes in the gap between the ITER ICRH antenna plug and the vessel can considerably increase the level of RF currents and voltages on the ITER plug and disturb the radiation characteristic of the array. We report on a study of these modes and a solution to avoid them in the ITER ion cyclotron range of frequencies. From a transmission line approach we show that resonances can be avoided if the distance between the mouth of the line and an added short-circuit is sufficiently small. We therefore propose to position short-circuits at about lm from the antenna mouth, constituted by rows of closely spaced contacts all around the plug. These conclusions are further validated with Microwave Studio simulations. A simplified model of the ITER ICRF array is used for comparing various grounding solutions and it is proved that the solution already inferred from transmission line approximation suppresses the resonances from the frequency domain relevant for ICRH in ITER. The MWS calculations predict that the proposed solution also avoids large RF currents in the blanket modules and in their connectors. Their amplitude barely exceeds 5% of the strap RF currents. This solution avoids perturbation of the antenna array impedance matrix by the coaxial gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of the ITER ECH Waveguide Transmission Line Expansion Unit

The ITER Electron Cyclotron Heating (ECH) system consists of transmission lines made up of individual sections of evacuated, aluminum, circularly corrugated waveguides. The high-intensity beam of electromagnetic radiation, necessary for plasma heating, heats the waveguides and other components in the transmission lines causing the lines to expand and contract. To maintain the structural integrity and the required straightness in the transmission lines, expansion units have to be incorporated into the ECH transmission line system. Calculations of several models of expansion units have been completed in this paper to evaluate the effect of the design and materials on the functionality of the expansion unit. Finally, models have been evaluated assuming three different expansion ranges and several different materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analysis of the ITER Vertical Stability Coils

The ITER vertical stability (VS) coils have been developed through the preliminary design phase by Princeton Plasma Physics Laboratory (PPPL). Final design, prototyping and construction will be carried out by the Chinese Participant Team contributing lab, Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). The VS coils are a part of the in-vessel coil systems which include edge localized mode (ELM) coils as well as the VS coils. An overview of the ELM coils is provided in another paper at this conference.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Shutdown Dose Rate in Fusion Energy Systems Using Hybrid Monte Carlo/Deterministic Techniques - Paper 138

Accurate assessments of shutdown dose rate (SDDR) are critical to support operation, maintenance, and waste disposal planning and to guide possible design changes of critical components in fusion energy systems. An SDDR calculation involves three steps: 1. a neutron transport calculation to determine the space and energy neutron flux distributions, 2. an activation calculation for computing the photon source distribution, and 3. a photon transport calculation for the estimation of the final SDDR. A companion paper describes the challenges of SDDR computations in fusion energy systems and the status of the techniques that are currently being used in SDDR analysis. Of these techniques, the rigorous 2-step (R2S) computational system entails Monte Carlo (MC) neutron and photon transport calculations coupled with a comprehensive activation step using a dedicated inventory code and library. The use of global MC variance reduction techniques was suggested for accelerating the SDDR MC neutron transport calculation. These techniques, which attempt to calculate MC tallies with nearly uniform relative uncertainties in both the low-flux space-energy regions and the high-flux space-energy regions, do not preferentially focus the MC computational efforts toward space-energy regions of high importance to the final decay dose. The ability of these approaches to accurately predict SDDR is inhibited by their prohibitive computational costs, which will be on the order of thousands of processor-years for full-scale modeling of an entire fusion plant. The companion paper describes the theoretical background of the Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) method, which has been proposed to speed up SDDR MC neutron calculations. The MS-CADIS method uses the CADIS method, which has been successfully used for more than a decade in shielding calculations, but focuses on multistep shielding calculations such as SDDR analyses. The companion paper also describes a new method for calculating the uncertainties in SDDR due to uncertainties in the MC neutron calculation. This new method of uncertainty propagation uses the MS-CADIS neutron adjoint source to propagate the uncertainties in the neutron fluxes to the SDDR. This paper describes the application of the MS-CADIS method for speeding up the SDDR MC calculations and for calculating the SDDR uncertainty due to the neutron flux uncertainties. A new metric for assessing the reliability of SDDR calculations was also suggested and used in this analysis. The ITER benchmark problem was used in this analysis. The problem resembles the configuration and geometrical arrangement of an upper port plug in ITER. The analysis compared the efficiency of the MS-CADIS method to the traditional approach of using global MC variance reduction techniques for speeding up SDDR MC neutron calculation. The application of the MS-CADIS method to SDDR calculations in fusion energy systems was tested using the ITER benchmark problem. Compared to the standard FW-CADIS method, the increase in the efficiency of the SDDR neutron MC calculation due to the use of the MS-CADIS method was between 18% and 69%. The MS-CADIS method also increases the fraction of non-zero-scoring mesh tally elements in the space-energy regions of high importance to the final SDDR. Implementation of the MS-CADIS method in the SCALE and the ADVANTG code systems is currently under way. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A Preliminary Analysis of Dose Rates Associated with ITER CVCS Equipment/Area Location

A preliminary analysis of the ITER Chemical and Volume Control System (CVCS) Area was performed to assess dose rates outside the walls and ceiling of the facility after 1.5 years of operation at shutdown, 2 days, and 10 days after shutdown. For this purpose a simplified Monte Carlo computer model was developed using the MCNP (MCNP5 Ver. 1.51) code. Two components are included: the smaller filter tank and the larger ion exchanger. These pieces of equipment are associated with the Integrated Blanket ELM Divertor Primary Heat Transfer System, which will have the largest dose rates associated with activated corrosion products during operation in comparison with other systems. The ion exchanger contained two source regions, a 1.2-m-thick resin bed above a 0.55 m-thick skirt, and a 0.8-m-thick water region. The filter constituted an additional source. Thus the model consisted of three sources (filter, resin, water), homogeneously distributed within the appropriate source regions. However, much of the results (that address individual isotopes) are presented with the two sources in the ion exchanger combined. In these cases the sources are referred to as the 'ion exchanger source' and the 'filter source.' Dimensions for the facility and components, as well as source isotopes and strengths, and material densities, were supplied by US ITER. Because of its simplification, the model does not contain pipes. Consequently, radiation streaming through pipe penetrations, radiation emanating from the pipes, and shielding from the pipes were not considered in this analysis. Dose rates on the outside of two walls and the ceiling were calculated. The two walls are labeled as the 'long' wall (aligned with the X-axis) and the 'short' wall (aligned with the Y-axis). These walls and ceiling were nominally set to 30-cm-thick concrete. In the original analysis, standard concrete (2.3 g/cc density) was used. In addition to the shielding walls/ceiling, a floor and an additional wall opposite the long wall were added for photon scattering contributions. These were both 10-cm-thick, standard concrete structures. Other components (tanks, pipes, etc.), that were not included in the model, would potentially add additional scattering and shielding. Possibly these additional effects will be addressed in a later, more detailed analysis. The room was 29.6 m in length (X-axis), but was limited to 15 m in the model. The inside width (Y axis) and height (Z axis) were 4 m and 3.4 m, respectively. The origin for the model was located inside the room at the corner opposite the long wall and adjacent to the short wall at the floor level. The room was filled with air at standard temperature and pressure. The stainless steel (SS304) wall thicknesses for the ion exchanger and filter were 2.2 cm and 0.8 cm, respectively. The axial center of the filter was located 140 cm from the short wall and 100 cm from the long wall (outer surface). The axial center of the ion exchanger was located 440 cm from the short wall and 250 cm from the long wall (inner surface). The resin was assumed to be a homogeneous mixture of equal atom density fractions of hydrogen and carbon* at a specified density of 1.136 g/cc. The filter material was assumed to be homogeneous carbon at a specified density of 1.8 g/cc. If the filter media were stainless steel and the accumulated activity were the same, the dose rate outside the filter would be lower, provided the density of the stainless steel sintered filter material is significantly higher than 1.8g/cc. The densities of the water and air were assumed to be 1.0 g/cc and 1.096E-3 g/cc, respectively. The model included 10 small volumes placed outside the model adjacent to the wall at locations where the dose rates were expected to be highest and which showed to a degree the fall-off of the dose rate with distance along a particular wall or ceiling. These 'tally cells' are shown in Fig. 2 and are described in Table 1. Each cell had dimensions of 50 cm x 50 cm x 1 cm and was oriented so that the 1-cm-thick dimension was perpendicular to the wall against which the cell was located. Also, smaller tally volumes were placed at 5 cm (updated model), 30 cm, 50 cm, and 100 cm from each source, both radially from the outside of each component at the height of each source mid-plane, and vertically, along the axial centerline, above the ion-exchanger and below the filter. (For the ion exchanger, the vertical distance was limited to 75 cm because of interference from the ceiling.) These tally regions can be seen in Fig. 3. Each cell had dimensions of 5 cm x 5 cm x 1 cm, oriented so that the 1-cm-thick dimension was perpendicular to the X, Y or Z axis.

08 HYDROGEN↗

Geometric Analysis Based Double Closed-loop Iterative Learning Control of Output PDF Shaping of Fiber Length Distribution in Refining Process

In order to improve the pulp quality and to reduce the energy consumption, the fiber length distribution (FLD) is generally employed as one of the important technological indexes in the refining process. Considering that the traditional mean and variance of fiber length are unable to adequately characterize the non-Gaussian distribution properties, this paper proposes a novel geometric analysis based double closed-loop iterative learning control (ILC) method for probability density function (PDF) shaping of output FLD in the refining process. Primarily, a RBF neural network (NN) with Gaussian-type is utilized to approximate the square root PDF in the inner loop, where the RBF basis function parameters (center and width) are tuned between any two adjacent batches by using an ILC law, and the subspace identification method can be applied to establish the state-space model of weight vector. Then, for the sake of accelerating the convergence rate of the closed-loop sysyem, a geometric analysis based ILC method is adopted in the outer loop. Lastly, both simulation and experiments demonstrate the effectiveness and practicability of the proposed approach.

42 ENGINEERING↗

ITER ECH Switch Design and Analysis

The electron cyclotron heating system (ECH) on ITER uses 24 evacuated microwave transmission lines carrying up to 1.4 MW of power each at 170 GHz to provide resonance heating of electrons in the ITER plasma and to enable plasma current drive. A critically important component in this system is the microwave switch that allows the microwaves to be directed from the gyrotrons to either dummy loads or between launchers in the upper and equatorial ports of the ITER tokamak while maintaining the vacuum integrity of the transmission lines. A moveable, water-cooled CuCrZr mirror is used to redirect the microwave transmission between two orthogonal waveguides. In this paper, we describe the optimized design of the mirror cooling passages produced by computational fluid dynamics analysis using ANSYS CFX with k-ε and k-ω shear stress transport turbulence models, and verify that the design parameters for mass flow rate, inlet temperature and pressure are adequate for good thermomechanical performance. Non-uniform heating of the mirror face from the incident microwaves induces deflections that should be less than 25 microns to meet the integrated transmission line efficiency specification. In the current 1.4 MW switch design, 0.03 kg/s of 36°C water at 10 bar inlet pressure can remove the 2660 W of ohmic heating in the mirror produced by the elliptical polarization power and maintain the surface temperature below 150°C. The water delta-T is 21°C with a 0.5 bar pressure drop in the mirror. Finally, the maximum predicted displacement in the center of the mirror face is less than 25 μm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical error analysis of SOLPS-ITER simulations of EAST

Abstract Plasma edge simulations with codes like SOLPS-ITER are widely employed to interpret fusion experiments. However, numerical errors appearing in such simulations are rarely investigated, despite their potential large impact on simulation results. These errors consist of the statistical error and the bias, both resulting from the finite number of employed EIRENE Monte Carlo particles and incomplete convergence, and the discretization error due to the finite resolution of the computational grids. In this contribution, the resulting numerical errors on simulations of pure deuterium and neon seeded H-mode EAST discharges are examined. The statistical error can be kept small compared to other numerical error contributions by averaging the plasma profiles. This allows investigating the bias and discretization errors using Richardson extrapolation. It is shown that grid refinement and the number of employed Monte Carlo particles have the largest influence on the result, in agreement with similar studies of an ITER deuterium case. For the first time, numerical error bars on the entire simulated target profiles are determined showing that the largest numerical error is 17.9%, mainly due to the plasma grid discretization. On top, also numerical errors on simulated neutral pressures are investigated in detail, for which the statistical error is dominant. The analysis demonstrates which setup is needed to keep numerical errors limited: the SOLPS-ITER averaging procedure should be employed including enough EIRENE particles, and the involved grids should be sufficiently refined to reduce discretization errors.

Boeyaert, Dieter (ORCID:0000000309208660)↗

Carbon charge exchange analysis in the ITER-like wall environment

Charge exchange spectroscopy has long been a key diagnostic tool for fusion plasmas and is well developed in devices with Carbon Plasma-Facing Components. Operation with the ITER-like wall at JET has resulted in changes to the spectrum in the region of the Carbon charge exchange line at 529.06 nm and demonstrates the need to revise the core charge exchange analysis for this line. An investigation has been made of this spectral region in different plasma conditions and the revised description of the spectral lines to be included in the analysis is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the phase control of the ITER ICRH antenna array. Influence on the load resilience and radiated power spectrum

The paper analyses how the phasing of the ITER ICRH 24 strap array evolves from the power sources up to the strap currents of the antenna. The study of the phasing control and coherence through the feeding circuits with prematching and automatic matching and decoupling network is made by modeling starting from the TOPICA matrix of the antenna array for a low coupling plasma profile and for current drive phasing (worst case for mutual coupling effects). The main results of the analysis are: (i) the strap current amplitude is well controlled by the antinode V{sub max} amplitude of the feeding lines, (ii) the best toroidal phasing control is done by the adjustment of the mean phase of V{sub max} of each poloidal straps column, (iii) with well adjusted system the largest strap current phasing error is ±20°, (iv) the effect on load resilience remains well below the maximum affordable VSWR of the generators, (v) the effect on the radiated power spectrum versus k{sub //} computed by means of the coupling code ANTITER II remains small for the considered cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phantom experiments to improve parathyroid lesion detection

This investigation tested the hypothesis that visual analysis of iteratively reconstructed tomograms by ordered subset expectation maximization (OSEM) provides the highest accuracy for localizing parathyroid lesions using {sup 99m}Tc-sestamibi SPECT data. From an Institutional Review Board approved retrospective review of 531 patients evaluated for parathyroid localization, image characteristics were determined for 85 {sup 99m}Tc-sestamibi SPECT studies originally read as equivocal (EQ). Seventy-two plexiglas phantoms using cylindrical simulated lesions were acquired for a clinically realistic range of counts (mean simulated lesion counts of 75{+-}50 counts/pixel) and target-to-background (T:B) ratios (range=2.0 to 8.0) to determine an optimal filter for OSEM. Two experienced nuclear physicians graded simulated lesions, blinded to whether chambers contained radioactivity or plain water, and two observers used the same scale to read all phantom and clinical SPECT studies, blinded to pathology findings and clinical information. For phantom data and all clinical data, T:B analyses were not statistically different for OSEM versus FB, but visual readings were significantly more accurate than T:B (88{+-}6% versus 68{+-}6%, p=0.001) for OSEM processing, and OSEM was significantly more accurate than FB for visual readings (88{+-}6% versus 58{+-}6%, p<0.0001). These data suggest that visual analysis of iteratively reconstructed MIBI tomograms should be incorporated into imaging protocols performed to localize parathyroid lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for the precision mass measurement of the stop quark at the international linear collider.

Many supersymmetric models predict new particles within the reach of the next generation of colliders. For an understanding of the model structure and the mechanism(s) of symmetry breaking, it is important to know the masses of the new particles precisely. In this article the measurement of the mass of the scalar partner of the top quark (stop) at an e{sup +}e{sup -} collider is studied. A relatively light stop is motivated by attempts to explain electroweak baryogenesis and can play an important role in dark matter relic density. A method is presented which makes use of cross-section measurements near the pair-production threshold as well as at higher center-of-mass energies. It is shown that this method not only increases the statistical precision, but also greatly reduces the systematic uncertainties, which can be important. Numerical results are presented, based on a realistic event simulation, for two signal selection strategies: using conventional selection cuts, and using an Iterative Discriminant Analysis (IDA). Our studies indicate that a precision of {Delta}m{tilde t}{sub 1} = 0.42 GeV can be achieved, representing a major improvement over previous studies. While the analysis of stops is particularly challenging due to the possibility of stop hadronization, the general procedure could be applied to the mass measurement of other particles as well. We also comment on the potential of the IDA to discover a stop quark in this scenario, and we revisit the accuracy of the theoretical predictions for the neutralino relic density.

43 PARTICLE ACCELERATORS↗

Structural Analysis of the US ITER ECH Transmission Line System

The electron cyclotron heating (ECH) and current drive system is one of the main plasma heating systems for ITER. It uses high-power microwave beams with the power deposition location steerable across the plasma cross section. Microwave power is conveyed via transmission lines (TLs) that run from the gyrotrons in the radio frequency building through the assembly hall and tokamak building to the ECH launchers within the tokamak vacuum vessel. The ECH system includes a vast array of interconnected TL waveguides, in-line components, and support structures.Finite element (FE) modeling provides an essential means of simulating the system, applying loads and determining deflections, rotations, forces, moments, and stresses in order to evaluate various structural and microwave transmission performance metrics. A representative FE model of the overall ECH TL system is developed in ANSYS®. This top-level model defines the centerline of the waveguide system. Waveguide segments are represented by line elements (beams and pipes) with equivalent section properties, and support structures are represented by boundary conditions. A systematic approach is used to model each ECH component with lumped masses and structurally equivalent stiffness matrices or ANSYS superelements.The top-level TL FE model is used to evaluate the various loads (thermal, vacuum, seismic, etc.) and operating scenarios. The top-level model directly calculates stresses in the straight aluminum waveguide segments. The model provides the forces and moments acting on the in-line components for detailed submodel assessments. Displacement results from the top-level analysis feed into a separate microwave performance model to help determine operational efficiency. All TL performance and thermal-structural requirements are met, as specified by the applicable codes and standards, and successfully documented in numerous technical reports and demonstrated at the final design review.

Shanmugasundaram, Aravind↗