Search NASA⌕ Search

SEARCH · Search NASA

Results for “kernel reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluating Performance Portability with the CMS Heterogeneous Pixel Reconstruction code

In the past years the landscape of tools for expressing parallel algorithms in a portable way across various compute accelerators has continued to evolve significantly. There are many technologies on the market that provide portability between CPU, GPUs from several vendors, and in some cases even FPGAs. These technologies include C++ libraries such as Alpaka and Kokkos, compiler directives such as OpenMP, the SYCL open specification that can be implemented as a library or in a compiler, and standard C++ where the compiler is solely responsible for the offloading. Given this developing landscape, users have to choose the technology that best fits their applications and constraints. For example, in the CMS experiment the experience so far in heterogeneous reconstruction algorithms suggests that the full application contains a large number of relatively short computational kernels and memory transfer operations. In this work we use a stand-alone version of the CMS heterogeneous pixel reconstruction code as a realistic use case of HEP reconstruction software that is capable of leveraging GPUs effectively. We summarize the experience of porting this code base from CUDA to Alpaka, Kokkos, SYCL, std::par, and OpenMP offloading. We compare the event processing throughput achieved by each version on NVIDIA and AMD GPUs as well as on a CPU, and compare those to what a native version of the code achieves on each platform.

Andriotis, Nikolaos↗

MO-F-CAMPUS-I-03: GPU Accelerated Monte Carlo Technique for Fast Concurrent Image and Dose Simulation

Purpose: To develop an accurate and fast Monte Carlo (MC) method of simulating CT that is capable of correlating dose with image quality using voxelized phantoms. Methods: A realistic voxelized phantom based on patient CT data, XCAT, was used with a GPU accelerated MC code for helical MDCT. Simulations were done with both uniform density organs and with textured organs. The organ doses were validated using previous experimentally validated simulations of the same phantom under the same conditions. Images acquired by tracking photons through the phantom with MC require lengthy computation times due to the large number of photon histories necessary for accurate representation of noise. A substantial speed up of the process was attained by using a low number of photon histories with kernel denoising of the projections from the scattered photons. These FBP reconstructed images were validated against those that were acquired in simulations using many photon histories by ensuring a minimal normalized root mean square error. Results: Organ doses simulated in the XCAT phantom are within 10% of the reference values. Corresponding images attained using projection kernel smoothing were attained with 3 orders of magnitude less computation time compared to a reference simulation using many photon histories. Conclusion: Combining GPU acceleration with kernel denoising of scattered photon projections in MC simulations allows organ dose and corresponding image quality to be attained with reasonable accuracy and substantially reduced computation time than is possible with standard simulation approaches.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-04: An Advanced Image Processing Method to Improve the Spatial Resolution of Proton Radiographies

Purpose: We present an optimization method to improve the spatial resolution and the water equivalent thickness accuracy of proton radiographies. Methods: The method is designed for imaging systems measuring only the residual range of protons without relying on tracker detectors to determine the beam trajectory before and after the target. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) working as a range telescope. The method uses a decomposition approach of the residual range signal measured by the PPIC and constructs subimages with small size pixels geometrically rearranged and appropriately averaged to be merged into a final single radiography. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. Results: For the step phantom, the effective spatial resolution was found to be 4 and 3 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed X-ray radiography convolved with a Gaussian kernel equal to the proton beam spot-size. For DTA=2.5 mm and RD=2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. An extension of the method allows reducing the dose given to the patient during radiography acquisition. We show that despite a dose reduction of 25 times (leading to a dose of 0.016 mGy for the current imaging set-up), the image quality of the optimized radiographies remains fairly unaffected for both the simulated and experimental results. Conclusion: The optimization method leads to a significant increase of the spatial resolution allowing recovering image details that are unresolved in non-optimized radiographies. These results represent a major step towards clinical application of proton radiography.

60 APPLIED LIFE SCIENCES↗

Evaluation of XCT for Matrix Density Measurement of Particle Fuel Forms

Particle fuel forms generally consist of a dispersion of fuel, such as tristructural isotropic (TRISO) particles, within a refractory matrix (e.g., graphite or silicon carbide). The density of matrix materials for particle fuel forms is of interest for modeling fuel form strength and thermal properties and may be specified as a quality control parameter, depending on reactor design. Some of the uncertainty associated with traditional, manual approaches can be eliminated by performing x-ray computed tomography (XCT) on the fuel forms and applying image processing methods to generate a precise count of the number of particles. This also removes the need to include determination of particle count within each individual fuel form during fabrication. Unfortunately, reconstruction artifacts from high-Z uranium-bearing kernels prevent accurate measurement of individual particle volumes using this approach, so the use of mean particle mass and volume are still necessary for computation of average fuel form matrix density. This method of using XCT to count particles in individual fuel form for determination of average matrix density was applied to three archived compacts from the Advanced Gas Reactor Fuel Development and Qualification (AGR)-1 campaign, four archived compacts with uranium carbide/uranium oxide (UCO) TRISO from the AGR-2 campaign, and three archived UO 2 -TRISO compacts from the AGR-2 campaign. The resulting density values were compared with those previously reported, showing slight changes due to uncertainties in the previously used number of particles in each of these cylindrical, graphite matrix compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reconstructing large-scale structure with neutral hydrogen surveys

Upcoming 21-cm intensity surveys will use the hyperfine transition in emission to map out neutral hydrogen in large volumes of the universe. Unfortunately, large spatial scales are completely contaminated with spectrally smooth astrophysical foregrounds which are orders of magnitude brighter than the signal. This contamination also leaks into smaller radial and angular modes to form a foreground wedge, further limiting the usefulness of 21-cm observations for different science cases, especially cross-correlations with tracers that have wide kernels in the radial direction. Here in this paper, we investigate reconstructing these modes within a forward modeling framework. Starting with an initial density field, a suitable bias parameterization and non-linear dynamics to model the observed 21-cm field, our reconstruction proceeds by {combining} the likelihood of a forward simulation to match the observations (under given modeling error and a data noise model) {with the Gaussian prior on initial conditions and maximizing the obtained posterior}. For redshifts z=2 and 4, we are able to reconstruct 21cm field with cross correlation, r c > 0.8 on all scales for both our optimistic and pessimistic assumptions about foreground contamination and for different levels of thermal noise. The performance deteriorates slightly at z=6. The large-scale line-of-sight modes are reconstructed almost perfectly. We demonstrate how our method also provides a technique for density field reconstruction for baryon acoustic oscillations, outperforming standard methods on all scales. We also describe how our reconstructed field can provide superb clustering redshift estimation at high redshifts, where it is otherwise extremely difficult to obtain dense spectroscopic samples, as well as open up a wealth of cross-correlation opportunities with projected fields (e.g. lensing) which are restricted to modes transverse to the line of sight.

21 cm↗

First simultaneous measurement of the top quark mass in the lepton+jets and dilepton channels at CDF

We present a measurement of the mass of the top quark using data corresponding to an integrated luminosity of 1.9 fb{sup -1} of pp collisions collected at {radical}(s)=1.96 TeV with the CDF II detector at Fermilab's Tevatron. This is the first measurement of the top quark mass using top-antitop pair candidate events in the lepton+jets and dilepton decay channels simultaneously. We reconstruct two observables in each channel and use a nonparametric kernel density estimation technique to derive two-dimensional probability density functions from simulated signal and background samples. The observables are the top quark mass and the invariant mass of two jets from the W decay in the lepton+jets channel, and the top quark mass and the scalar sum of transverse energy of the event in the dilepton channel. We perform a simultaneous fit for the top quark mass and the jet energy scale, which is constrained in situ by the hadronic W boson mass. Using 332 lepton+jets candidate events and 144 dilepton candidate events, we measure the top quark mass to be M{sub top}=171.9{+-}1.7(stat+JES){+-}1.1(other syst) GeV/c{sup 2}=171.9{+-}2.0 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstrating Cross-Facility Data Processing at Scale with Laue Microdiffraction

In February and April 2023 live, at-scale data processing demonstrations were conducted between the Advanced Photon Source (APS), a synchrotron light source, and the Argonne Leadership Computing Facility (ALCF). These tests were run as part of a novel beamline technique: coded aperture laue micro-diffraction. This technique requires a significant amount of compute to decode appeture patterns embedded in the detector stream. An autonomous system was able to send data to ALCF during an experiment, utilize 50 nodes of the Polaris supercomputer to process 6-12 hour scans, and return the data back to the APS within 12-15 minutes behind the detector. With scan points arriving every 72 seconds, the system kept up with the beamline, potentially enabling in-experiment analysis. The data processing system utilizes Globus infrastructure and an on-demand queue to dynamically acquire nodes on Polaris. The underlying reconstruction algorithms were parallelized via MPI and accelerated with custom CUDA kernels.

Prince, Michael↗

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circuits is important for security and reliability assurance. Two scanning operations are required: ptychographic to recover the complex transmissivity of the specimen, and rotation of the specimen to acquire multiple projections covering the 3D spatial frequency domain. Two types of rotational scanning are possible: tomographic and laminographic. For flat, extended samples, for which the full 180° coverage is not possible, the latter is preferable because it provides better coverage of the 3D spatial frequency domain compared to limited-angle tomography. It is also because the amount of attenuation through the sample is approximately the same for all projections. However, both techniques are time consuming because of extensive acquisition and computation time. Here, we demonstrate the acceleration of ptycho-laminographic reconstruction of integrated circuits with 16 times fewer angular samples and 4.67 times faster computation by using a physics-regularized deep self-supervised learning architecture. We check the fidelity of our reconstruction against a densely sampled reconstruction that uses full scanning and no learning. As already reported elsewhere [ Opt. Express 28 , 12872 ( 2020 ) OPEXFF 1094-4087 10.1364/OE.379200 ], we observe improvement of reconstruction quality even over the densely sampled reconstruction, due to the ability of the self-supervised learning kernel to fill the missing cone.

47 OTHER INSTRUMENTATION↗

Microstructure and fission products in the UCO kernel of an AGR-1 TRISO fuel particle after post irradiation safety testing

Tristructural isotropic (TRISO) coated particle fuel as a key fuel concept for the High Temperature Gas-cooled Reactors (HTGRs) and a candidate accident tolerant fuel (ATF) has been currently investigated under the US-DOE Advanced Gas Reactor (AGR) fuel development and qualification program. Over the past decades, extensive studies have been conducted to evaluate the fission product release, diffusion on Ag, Pd and Cd in the SiC layer and the TRISO coating system, and post-safety-test performance. However, to date, there are limited reported results on the fuel kernels’ response to irradiation with or without post irradiation high temperature annealing. To incrementally fulfill this knowledge gap extensive studies using transmission electron microscopes (TEM) and atom probe tomography (APT) were conducted on a TRISO fuel particle kernel with a 19.74% 235U enrichment, irradiated to 18.63% FIMA and subsequently subjected to post-safety testing at 1600ºC for 300 hours.. Microstructure characterizations, elemental analysis, and phase identification were conducted using conventional TEM and scanning TEM (STEM) imaging, energy-dispersive X-ray spectroscopy (EDS), selected-area electron diffraction (SAED) and atom probe tomography (APT). The following findings were made: (1) significant reconstructions and phase evolutions occurred in the irradiated and post-safety annealed fuel kernel, and its microstructure consists of two primary phases, namely a “high-Z (atomic mass)” UC phase and a “low-Z” UO phase, (2) no fission gas bubbles are identified within the fuel kernel, that can be attributed to the high temperature post safety annealing, (3) fission products Zr, Nb, Mo, Ru, Tc and Rh were found to preferentially segregate into UC phase or to form metallic precipitates, while the lanthanide fission products tend to stay in the solution of UO phase, (4) Pd was detected in the rod-shaped precipitates, (5) APT data reveals segregation of Te, Pd, and Ag at the UO and UC phase boundary, and (6) Pd is detected in both the UO and UC phases but with an enrichment in the former one.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MO-FG-CAMPUS-TeP1-05: Rapid and Efficient 3D Dosimetry for End-To-End Patient-Specific QA of Rotational SBRT Deliveries Using a High-Resolution EPID

Purpose: EPID-based patient-specific quality assurance provides verification of the planning setup and delivery process that phantomless QA and log-file based virtual dosimetry methods cannot achieve. We present a method for EPID-based QA utilizing spatially-variant EPID response kernels that allows for direct calculation of the entrance fluence and 3D phantom dose. Methods: An EPID dosimetry system was utilized for 3D dose reconstruction in a cylindrical phantom for the purposes of end-to-end QA. Monte Carlo (MC) methods were used to generate pixel-specific point-spread functions (PSFs) characterizing the spatially non-uniform EPID portal response in the presence of phantom scatter. The spatially-variant PSFs were decomposed into spatially-invariant basis PSFs with the symmetric central-axis kernel as the primary basis kernel and off-axis representing orthogonal perturbations in pixel-space. This compact and accurate characterization enables the use of a modified Richardson-Lucy deconvolution algorithm to directly reconstruct entrance fluence from EPID images without iterative scatter subtraction. High-resolution phantom dose kernels were cogenerated in MC with the PSFs enabling direct recalculation of the resulting phantom dose by rapid forward convolution once the entrance fluence was calculated. A Delta4 QA phantom was used to validate the dose reconstructed in this approach. Results: The spatially-invariant representation of the EPID response accurately reproduced the entrance fluence with >99.5% fidelity with a simultaneous reduction of >60% in computational overhead. 3D dose for 10{sub 6} voxels was reconstructed for the entire phantom geometry. A 3D global gamma analysis demonstrated a >95% pass rate at 3%/3mm. Conclusion: Our approach demonstrates the capabilities of an EPID-based end-to-end QA methodology that is more efficient than traditional EPID dosimetry methods. Displacing the point of measurement external to the QA phantom reduces the necessary complexity of the phantom itself while offering a method that is highly scalable and inherently generalizable to rotational and trajectory based deliveries. This research was partially supported by Varian.

60 APPLIED LIFE SCIENCES↗

Modelling the Lyman-α forest with Eulerian and SPH hydrodynamical methods

ABSTRACT We compare two state-of-the-art numerical codes to study the overall accuracy in modelling the intergalactic medium and reproducing Lyman-α forest observables for DESI and high-resolution data sets. The codes employ different approaches to solving both gravity and modelling the gas hydrodynamics. The first code, Nyx, solves the Poisson equation using the Particle-Mesh (PM) method and the Euler equations using a finite-volume method. The second code, CRK-HACC , uses a Tree-PM method to solve for gravity, and an improved Lagrangian smoothed particle hydrodynamics (SPH) technique, where fluid elements are modelled with particles, to treat the intergalactic gas. We compare the convergence behaviour of the codes in flux statistics as well as the degree to which the codes agree in the converged limit. We find good agreement overall with differences being less than observational uncertainties, and a particularly notable ≲1 per cent agreement in the 1D flux power spectrum. This agreement was achieved by applying a tessellation methodology for reconstructing the density in CRK-HACC instead of using an SPH kernel as is standard practice. We show that use of the SPH kernel can lead to significant and unnecessary biases in flux statistics; this is especially prominent at high redshifts, z ∼ 5, as the Lyman-α forest mostly comes from lower-density regions that are intrinsically poorly sampled by SPH particles.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing Error-Bounded Lossy Compression for Scientific Data on GPUs

Error-bounded lossy compression is a critical technique for significantly reducing scientific data volumes. With ever-emerging heterogeneous high-performance computing (HPC) architecture, GPU-accelerated error-bounded compressors (such as CUSZ and cuZFP) have been developed. However, they suffer from either low performance or low compression ratios. To this end, we propose CUSZ+ to target both high compression ratios and throughputs. We identify that data sparsity and data smoothness are key factors for high compression throughputs. Our key contributions in this work are fourfold: (1) We propose an efficient compression workflow to adaptively perform run-length encoding and/or variable-length encoding. (2) We derive Lorenzo reconstruction in decompression as multidimensional partial-sum computation and propose a fine-grained Lorenzo reconstruction algorithm for GPU architectures. (3) We carefully optimize each of CUSZ kernels by leveraging state-of-the-art CUDA parallel primitives. (4) We evaluate CUSZ+ using seven real-world HPC application datasets on V100 and A100 GPUs. Experiments show CUSZ+ improves the compression throughputs and ratios by up to 18.4x and 5.3x, respectively, over CUSZ on the tested datasets.

Tian, Jiannan↗

Investigation of the accuracy of modeling the orientation distribution function of polycrystalline materials from individual orientations

The accuracy of reconstructing the orientation distribution function of grains in polycrystalline materials by the kernel method from a set of individual orientations has been studied. In particular, the influence of choosing the smoothing kernel in the kernel method and the influence of the dependence on the resulting distribution are taken into account. The rotations obeying the normal distribution on the group SO(3) and obtained by the statistical test method are used as an orientation set. Some aspects of electron backscattering diffraction measurements are considered. This problem is urgent in view of the expanding potential of the experimental study of the texture of polycrystalline materials, especially for electron microscopy, which makes it possible to measure the orientations of individual grains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The First measurement of the top quark mass at CDF II in the lepton+jets and dilepton channels simultaneously

The authors present a measurement of the mass of the top quark using data corresponding to an integrated luminosity of 1.9 fb{sup -1} of p{bar p} collisions collected at {radical}s = 1.96 TeV with the CDF II detector at Fermilab's Tevatron. This is the first measurement of the top quark mass using top-antitop pair candidate events in the lepton + jets and dilepton decay channels simultaneously. They reconstruct two observables in each channel and use a non-parametric kernel density estimation technique to derive two-dimensional probability density functions from simulated signal and background samples. The observables are the top quark mass and the invariant mass of two jets from the W decay in the lepton + jets channel, and the top quark mass and the scalar sum of transverse energy of the event in the diletpon channel. They perform a simultaneous fit for the top quark mass and the jet energy scale, which is constrained in situ by the hadronic W boson mass. using 332 lepton + jets candidate events and 144 diletpon candidate events, they measure the top quark mass to be m{sub top} = 171.9 {+-} 1.7 (stat. + JES) {+-} 1.1 (other sys.) GeV/c{sup 2} = 171.9 {+-} 2.0 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction in quantum field theory with a fundamental length

In this paper, we establish an analog of Wightman's reconstruction theorem for nonlocal quantum field theory with a fundamental length. In our setting, the Wightman generalized functions are defined on test functions analytic in a complex l-neighborhood of the real space and are localizable at scales large compared to l. The causality condition is formulated as continuity of the field commutator in an appropriate topology associated with the light cone. We prove that the relevant function spaces are nuclear and derive the kernel theorems for the corresponding classes of multilinear functionals, which provides the basis for the reconstruction procedure. Special attention is given to the accurate determination of the domain of the reconstructed quantum fields in the Hilbert space of states. We show that the primitive common invariant domain must be suitably extended to implement the (quasi)localizability and causality conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Acquisition of STEM Images by Adaptive Compressive Sensing

Compressive Sensing (CS) allows a signal to be sparsely measured first and accurately recovered later in software [1]. In scanning transmission electron microscopy (STEM), it is possible to compress an image spatially by reducing the number of measured pixels, which decreases electron dose and increases sensing speed [2,3,4]. The two requirements for CS to work are: (1) sparsity of basis coefficients and (2) incoherence of the sensing system and the representation system. However, when pixels are missing from the image, it is difficult to have an incoherent sensing matrix. Nevertheless, dictionary learning techniques such as Beta-Process Factor Analysis (BPFA) [5] are able to simultaneously discover a basis and the sparse coefficients in the case of missing pixels. On top of CS, we would like to apply active learning [6,7] to further reduce the proportion of pixels being measured, while maintaining image reconstruction quality. Suppose we initially sample 10% of random pixels. We wish to select the next 1% of pixels that are most useful in recovering the image. Now, we have 11% of pixels, and we want to decide the next 1% of “most informative” pixels. Active learning methods are online and sequential in nature. Our goal is to adaptively discover the best sensing mask during acquisition using feedback about the structures in the image. In the end, we hope to recover a high quality reconstruction with a dose reduction relative to the non-adaptive (random) sensing scheme. In doing this, we try three metrics applied to the partial reconstructions for selecting the new set of pixels: (1) variance, (2) Kullback-Leibler (KL) divergence using a Radial Basis Function (RBF) kernel, and (3) entropy. Figs. 1 and 2 display the comparison of Peak Signal-to-Noise (PSNR) using these three different active learning methods at different percentages of sampled pixels. At 20% level, all the three active learning methods underperform the original CS without active learning. However, they all beat the original CS as more of the “most informative” pixels are sampled. One can also argue that CS equipped with active learning requires less sampled pixels to achieve the same value of PSNR than CS with pixels randomly sampled, since all the three PSNR curves with active learning grow at a faster pace than that without active learning. For this particular STEM image, by observing the reconstructed images and the sensing masks, we find that while the method based on RBF kernel acquires samples more uniformly, the one on entropy samples more areas of significant change, thus less uniformly. The KL-divergence method performs the best in terms of reconstruction error (PSNR) for this example [8].

Xie, Weiyi↗

SU-F-SPS-06: Implementation of a Back-Projection Algorithm for 2D in Vivo Dosimetry with An EPID System

Purpose: To implement a back-projection algorithm for 2D dose reconstructions for in vivo dosimetry in radiation therapy using an Electronic Portal Imaging Device (EPID) based on amorphous silicon. Methods: An EPID system was used to calculate dose-response function, pixel sensitivity map, exponential scatter kernels and beam hardenig correction for the back-projection algorithm. All measurements were done with a 6 MV beam. A 2D dose reconstruction for an irradiated water phantom (30×30×30 cm{sup 3}) was done to verify the algorithm implementation. Gamma index evaluation between the 2D reconstructed dose and the calculated with a treatment planning system (TPS) was done. Results: A linear fit was found for the dose-response function. The pixel sensitivity map has a radial symmetry and was calculated with a profile of the pixel sensitivity variation. The parameters for the scatter kernels were determined only for a 6 MV beam. The primary dose was estimated applying the scatter kernel within EPID and scatter kernel within the patient. The beam hardening coefficient is σBH= 3.788×10{sup −4} cm{sup 2} and the effective linear attenuation coefficient is µAC= 0.06084 cm{sup −1}. The 95% of points evaluated had γ values not longer than the unity, with gamma criteria of ΔD = 3% and Δd = 3 mm, and within the 50% isodose surface. Conclusion: The use of EPID systems proved to be a fast tool for in vivo dosimetry, but the implementation is more complex that the elaborated for pre-treatment dose verification, therefore, a simplest method must be investigated. The accuracy of this method should be improved modifying the algorithm in order to compare lower isodose curves.

60 APPLIED LIFE SCIENCES↗

Profiling Saturn's rings by radio occultation

The development of reconstruction algorithms that correct for diffraction effects in radio occultation measurements is described. The reciprocal Fresnel transform relationship between the complex amplitude of the observed coherent signal and the complex microwave transmittance of the rings is derived using the Huygens-Fresnel formulation of the diffraction problem. The effects of the finite data segment width, the uncertainties in the Fresnel scale, systematic phase errors in the kernel of the inverse transform, reference oscillator instabilities, and random noise measurements on the resolution of the reconstructed transmittance are analyzed. Examples of reconstructed opacity profiles for some regions of Saturn's rings derived by applying the reconstruction theory to Voyager 1 at Saturn data are presented.

Marouf, Essam A.↗