Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Shock compression of molybdenum single crystals to 110 GPa: Elastic–plastic deformation and crystal anisotropy

To explore the role of crystal anisotropy on the elastic-plastic deformation of BCC single crystals at high shock stresses, molybdenum (Mo) single crystals were shock compressed along [100], [111], and [110] orientations at elastic impact stresses between 20 and 110 GPa. Laser interferometry was used to measure shock wave velocities and particle velocity histories. Along the [100] and [111] orientations, elastic-plastic waves (two wave structure) were observed up to 110 GPa. Along the [110] orientation, the two wave structure was observed only up to 90 GPa. The measured elastic wave amplitudes were analyzed to determine crystal anisotropy effects, impact stress dependence, and the activated slip systems on the Hugoniot elastic limit. The results from our work have provided insight into the role of crystal anisotropy on the elastic-plastic deformation under shock compression at high stresses.

42 ENGINEERING↗

Collective optical Thomson scattering in pulsed-power driven high energy density physics experiments (invited)

Optical collective Thomson scattering is used to diagnose magnetized high energy density physics experiments at the Magpie pulsed-power generator at Imperial College London. The system uses an amplified pulse from the 2nd harmonic of a Nd:YAG laser (3 J, 8 ns, 532 nm) to probe a wide diversity of hightemperature plasma objects; with densities in the range of 10 17 -10 19 cm -3 and temperatures between 10 eV and a few keV. The scattered light is collected from 100 μm-scale volumes within the plasmas, which are imaged onto optical fiber arrays. Multiple collection systems observe these volumes from different directions, providing simultaneous probing with different scattering K-vectors (and different associated α-parameters, typically in the range 0.5 – 3) allowing independent measurements of separate velocity components of the bulk plasma flow. The fiber arrays are coupled to an imaging spectrometer with a gated ICCD. The spectrometer is configured to view the ion-acoustic waves (IAWs) of the collective Thomson scattered spectrum. Fits to the spectra with the theoretical spectral density function S(K,ω) yield measurements of the local plasma temperatures and velocities. Fitting is constrained by independent measurements of the electron density from laser interferometry, and the corresponding spectra for different scattering vectors. Furthermore, this TS diagnostic has been successfully implemented on a wide range of experiments, revealing temperature and flow velocity transitions across magnetized shocks, inside rotating plasma jets and imploding wire arrays, as well as providing direct measurements of drift velocities inside a magnetic reconnection current sheet.

47 OTHER INSTRUMENTATION↗

Shock compression of single-crystal austenitic FeCr18Ni12.5 stainless steel to 60 GPa

We measured the austenitic FeCr18Ni12.5 stainless steel Hugoniot as a function of crystallographic direction to approximately 60 GPa. We shock-compressed FeCr18Ni12.5 samples oriented along $\langle$100$\rangle$, $\langle$110$\rangle$, and $\langle$111$\rangle$ to mean stresses ranging 30.5–58.1 GPa via Ta plate impact in a large-bore powder gun and measured the free-surface velocities with laser interferometry. We unambiguously observed the largest post-shock free-surface velocity along $\langle$100$\rangle$ in each experiment, which consequently produced the lowest shock velocity along that orientation. However, the propagation of experimental uncertainties through the impedance matching scheme used to compute the shock velocity produced sufficient uncertainty overlap to preclude definitive conclusion of Hugoniot anisotropy.

36 MATERIALS SCIENCE↗

Dynamic polarizability of tungsten atoms reconstructed from fast electrical explosion of fine wires in vacuum

For nanosecond electrical explosion of fine metal wires in vacuum generates calibrated, radially expanded gas cylinders of metal atoms are surrounded by low-density fast expanding plasma corona. Here, a novel integrated-phase technique, based on laser interferometry, provides the dynamic dipole polarizability of metal atoms. This data was previously unavailable for tungsten atoms. Furthermore, an extremely high melting temperature and significant pre-melt electronic emission make these measurements particularly complicated for this refractory metal.

74 ATOMIC AND MOLECULAR PHYSICS↗

Polymorphism of gold under laser-based ramp compression to 690 GPa

The high-pressure behavior and polymorphism of gold has attracted strong recent interest from theory as well as from both static and dynamic experiments. In this study, gold was dynamically ramp-compressed to 690 GPa via laser ablation using the Omega Laser Facility (U. Rochester) in order to investigate the stability regions of this noble metal's polymorphs. Here, stresses were determined from measurements of surface or interface velocities by laser interferometry. In situ X-ray diffraction was carried out to constrain the structure and density. The ambient face-centered-cubic (fcc) phase was observed at 162 GPa, followed by a mixed phase region consisting of the fcc and body-centeredcubic (bcc). The presence of only the bcc phase was observed between 377 and 690 GPa. Our results are consistent with recent shock compression experiments and demonstrate that gold transforms to the bcc phase under conditions of both ramp and shock loading.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elastic moduli of hexagonal diamond and cubic diamond formed under shock compression

The relative stiffnesses and strengths of hexagonal diamond and cubic diamond constitute long standing unresolved issues, because relevant experimental results are lacking. Laser interferometry was used to experimentally determine the longitudinal sound speeds and moduli in hexagonal diamond and cubic diamond formed during the shock compression of graphite. The hexagonal diamond longitudinal moduli are significantly larger than the cubic diamond longitudinal moduli, and even exceed averaged cubic diamond single crystal values. Here, the measured hexagonal diamond longitudinal moduli, combined with high-pressure bulk moduli for cubic diamond single crystals, show that shock-formed hexagonal diamond shear moduli are larger than the shear moduli for cubic diamond single crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sound velocities in shock-compressed soda lime glass: Melting and liquid-state response

Longitudinal sound velocities (and elastic moduli) were determined in soda lime glass (SLG) at peak shock stresses ranging between 40 and 90 GPa. Laser interferometry was used to obtain particle velocity histories and sound velocities by impacting SLG samples on lithium fluoride (LiF) optical windows. In all experiments, the SLG response consists of a sharp jump to a constant state followed by a release wave. The measured longitudinal sound velocities and moduli showed a marked decrease between 52 and 58 GPa, providing experimental evidence for the transformation from an amorphous solid to a liquid in shock-compressed SLG. Furthermore, the stress threshold (~55 GPa) for melting in SLG is considerably lower than the threshold reported in shock-compressed fused silica (~72 GPa), showing the effect of network-modifying cations on the onset of melting. The relative values of sound velocities, shock velocities, and the Hugoniot slopes—between 58 and 90 GPa—are fully consistent with the thermodynamic response of a shock-compressed liquid. Using the experimental results, the Grüneisen parameter (Γ) values were determined for liquid SLG to 90 GPa and then used to provide the Mie-Grüneisen equation of state for liquid SLG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic compression of [100] MgF 2 single crystals: Shock-induced polymorphism to highly coordinated structures

AX 2 -type compounds exhibit a rich and complex series of phase transitions under compression. The high-pressure polymorphism of rutile-type AX 2 difluorides can be characterized by a typical sequence from rutile type → Ca Cl 2 type → HP – Pd F 2 type → cotunnite type . Relative to dioxides, the reduced valence and ionic radius of the F – anion in rutile-type MgF 2 (sellaite) results in lowered transition pressures, making it a useful analog for SiO 2 and other dioxides. In this work, MgF 2 single crystals were shock-compressed along the [100] direction to 24 to 120 GPa using plate impact techniques, and wave profiles were measured using laser interferometry. At low stresses (24 to 44 GPa), we observe features consistent with an elastic–inelastic response, followed by a phase transformation. Peak stress-density states in this stress range are consistent with those expected for the modified fluorite-type (HP- PdF 2 ) phase or a related structure. At higher stresses (69 to 91 GPa), we observe a two-wave structure with peak stress-density states consistent with transformation to a denser and likely more highly coordinated phase such as the cotunnite-type structure. Furthermore, at 120 GPa, only a single wave structure is observed, indicating that the wave profile features observed at lower stresses are overdriven.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strength and deformation of shocked diamond single crystals: Orientation dependence

Understanding and quantifying the strength or elastic limit of diamond single crystals is of considerable scientific and technological importance, and has been a subject of long standing theoretical and experimental interest. To examine the effect of crystalline anisotropy on strength and deformation of shocked diamond single crystals, plate impact experiments were conducted to measure wave profiles at various elastic impact stresses up to ~120 GPa along [110] and [111] crystal orientations. Using laser interferometry, particle velocity histories and shock velocities in the diamond samples were measured and were compared with similar measurements published previously for shock compression along the [100] direction. Wave profiles for all three orientations showed large elastic wave amplitudes followed by time-dependent inelastic deformation. From the measured wave profiles, the elastic limits were determined under well characterized uniaxial strain loading conditions. The measured elastic wave amplitudes for the [110] and [111] orientations were lower for higher elastic impact stress (stress attained for an elastic diamond response), consistent with the result reported previously for [100] diamond. The maximum resolved shear stress (MRSS) on the {111}<110> slip systems was determined for each orientation, revealing significant orientation dependence. The MRSS values for the [100] and [110] orientations (~33 GPa) are 25-30% of theoretical estimates; the MRSS value for the [111] orientation is significantly lower (~23 GPa). Our results demonstrate that the MRSS depends strongly on the stress component normal to the {111} planes or the resolved normal stress (RNS), suggesting that the RNS plays a key role in inhibiting the onset of inelastic deformation. Lower elastic wave amplitudes at higher peak stress and the effect of the RNS are inconsistent with typical dislocation slip mechanisms of inelastic deformation, suggesting instead an inelastic response characteristic of shocked brittle solids. The present results show that the elastic limit (or material strength) of diamond single crystals cannot be described using traditional isotropic approaches, and typical plasticity models cannot be used to describe the inelastic deformation of diamond. Analysis of the measured wave profiles beyond the elastic limit, including characterization of the peak state, requires numerical simulations that incorporate a time-dependent, anisotropic, inelastic deformation response. Development of such a material description for diamond is an important need.

36 MATERIALS SCIENCE↗

Counterpropagating Radiative Shock Experiments on the Orion Laser

We present new experiments to study the formation of radiative shocks and the interaction between two counterpropagating radiative shocks. The experiments are performed at the Orion laser facility, which is used to drive shocks in xenon inside large aspect ratio gas cells. The collision between the two shocks and their respective radiative precursors, combined with the formation of inherently three-dimensional shocks, provides a novel platform particularly suited for the benchmarking of numerical codes. The dynamics of the shocks before and after the collision are investigated using point-projection x-ray backlighting while, simultaneously, the electron density in the radiative precursor was measured via optical laser interferometry. Modeling of the experiments using the 2D radiation hydrodynamic codes nym and petra shows very good agreement with the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Piezoelectric Actuation of Graphene-Coated Polar Structures

Ferroelectric materials based on lead zirconate titanate (PZT) are widely used as sensors and actuators because of their strong piezoelectric activity. However, their application is limited because of the high processing temperature, brittleness, lack of conformal deposition, and a limited possibility to be integrated with the microelectromechanical systems (MEMS). Recent studies on the piezoelectricity in the 2-D materials have demonstrated their potential in these applications, essentially due to their flexibility and integrability with the MEMS. In this work, we deposited a few layer graphene (FLG) on the amorphous oxidized Si 3 N 4 membranes and studied their piezoelectric response by sensitive laser interferometry and rigorous finite-element modeling (FEM) analysis. Modal analysis by FEM and comparison with the experimental results show that the driving force for the piezoelectric-like response can be a polar interface layer formed between the residual oxygen in Si 3 N 4 and the FLG. The response was about 14 nm/V at resonance and could be further enhanced by adjusting the geometry of the device. These phenomena are fully consistent with the earlier piezoresponse force microscopy (PFM) observations of the piezoelectricity of the graphene on SiO 2 and open up an avenue for using graphene-coated structures in the MEMS.

36 MATERIALS SCIENCE↗

Pressure-shear experiments on granular materials.

Pressure-shear experiments were performed on granular tungsten carbide and sand using a newly-refurbished slotted barrel gun. The sample is a thin layer of the granular material sandwiched between driver and anvil plates that remain elastic. Because of the obliquity, impact generates both a longitudinal wave, which compresses the sample, and a shear wave that probes the strength of the sample. Laser velocity interferometry is employed to measure the velocity history of the free surface of the anvil. Since the driver and anvil remain elastic, analysis of the results is, in principal, straightforward. Experiments were performed at pressures up to nearly 2 GPa using titanium plates and at higher pressure using zirconium plates. Those done with the titanium plates produced values of shear stress of 0.1-0.2 GPa, with the value increasing with pressure. On the other hand, those experiments conducted with zirconia anvils display results that may be related to slipping at an interface and shear stresses mostly at 0.1 GPa or less. Recovered samples display much greater particle fracture than is observed in planar loading, suggesting that shearing is a very effective mechanism for comminution of the grains.

36 MATERIALS SCIENCE↗

Compendium of Instrumentation Whitepapers on Frontier Physics Needs for Snowmass 2013

Contents of collection of whitepapers include: Operation of Collider Experiments at High Luminosity; Level 1 Track Triggers at HL-LHC; Tracking and Vertex Detectors for a Muon Collider; Triggers for hadron colliders at the energy frontier; ATLAS Upgrade Instrumentation; Instrumentation for the Energy Frontier; Particle Flow Calorimetry for CMS; Noble Liquid Calorimeters; Hadronic dual-readout calorimetry for high energy colliders; Another Detector for the International Linear Collider; e+e- Linear Colliders Detector Requirements and Limitations; Electromagnetic Calorimetry in Project X Experiments The Project X Physics Study; Intensity Frontier Instrumentation; Project X Physics Study Calorimetry Report; Project X Physics Study Tracking Report; The LHCb Upgrade; Neutrino Detectors Working Group Summary; Advanced Water Cherenkov R&D for WATCHMAN; Liquid Argon Time Projection Chamber (LArTPC); Liquid Scintillator Instrumentation for Physics Frontiers; A readout architecture for 100,000 pixel Microwave Kinetic In- ductance Detector array; Instrumentation for New Measurements of the Cosmic Microwave Background polarization; Future Atmospheric and Water Cherenkov ?-ray Detectors; Dark Energy; Can Columnar Recombination Provide Directional Sensitivity in WIMP Search?; Instrumentation Needs for Detection of Ultra-high Energy Neu- trinos; Low Background Materials for Direct Detection of Dark Matter; Physics Motivation for WIMP Dark Matter Directional Detection; Solid Xenon R&D at Fermilab; Ultra High Energy Neutrinos; Instrumentation Frontier: Direct Detection of WIMPs; nEXO detector R&D; Large Arrays of Air Cherenkov Detectors; and Applications of Laser Interferometry in Fundamental Physics Experiments.

Lipton, R.↗

Embedded Fiber Optic Sensors for Measuring Transient Detonation/Shock Behavior;Time-of-Arrival Detection and Waveform Determination.

The miniaturization of explosive components has driven the need for a corresponding miniaturization of the current diagnostic techniques available to measure the explosive phenomena. Laser interferometry and the use of spectrally coated optical windows have proven to be an essential interrogation technique to acquire particle velocity time history data in one- dimensional gas gun and relatively large-scale explosive experiments. A new diagnostic technique described herein allows for experimental measurement of apparent particle velocity time histories in microscale explosive configurations and can be applied to shocks/non-shocks in inert materials. The diagnostic, Embedded Fiber Optic Sensors (EFOS), has been tested in challenging microscopic experimental configurations that give confidence in the technique's ability to measure the apparent particle velocity time histories of an explosive with pressure outputs in the tenths of kilobars to several kilobars. Embedded Fiber Optic Sensors also allow for several measurements to be acquired in a single experiment because they are microscopic, thus reducing the number of experiments necessary. The future of EFOS technology will focus on further miniaturization, material selection appropriate for the operating pressure regime, and extensive hydrocode and optical analysis to transform apparent particle velocity time histories into true particle velocity time histories as well as the more meaningful pressure time histories.

Chavez, Marcus Alexander↗

New Strainmeters used to Monitor Deformation During Injection and Withdrawal

Injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. This has motivated us to develop instrumentation and methods to characterize the strain field resulting from injection and pumping. Three new instruments have been deployed at our field stations near Clemson University and at the Avant Field north of Tulsa, OK. Two use non-contact eddy current transducers configured to measure four components of strain and two tilts to 1 part-per-billion. One system is designed for permanent installation, the other is removable for short term deployments. Another system is a low cost volumetric strainmeter consisting of an embedded optical fiber that is interrogated using laser interferometry. This strainmeter is designed to be a permanently installed and has a resolution of several parts-per-trillion. The field sites are designed to characterize strains during pumping or injection over different scales and in different geologic settings. The Clemson field station is underlain by biotite gneiss, a low permeability crystalline rock overlain by moderate permeability, soft saprolite above 30m depth. The water table is at approximately 9m depth. The strainmeters are in the crystalline rock at approximately 40m depth, and pumping occurs in the overlying saprolite. In contrast, wells at the Avant Field site are much deeper. They are approximately 500m deep and completed in a 25-m-thick oil-bearing sandstone. Strainmeters at the Avant Field are at ~30m depth. These two sites provide contrasting approaches to characterizing strain at 30-40m depth. Water is pumped from an overlying formation at the Clemson site, whereas it is pumped from a much deeper underlying formation at the Avant Field. Preliminary results are available from a brief injection test, and from a longer shut-in test at the Avant Field. Injection is characterized by an increase in tensile strains in both the radial and circumferential directions approximately 220m from the well. The shut-in was characterized by radial tension and circumferential compression in response to a well approximately 1km from the strainmeter. These are the expected signals caused by injection and shut-in according to poroelastic simulations.

DeWolf, Scott↗

Electron density and gas density measurements in a millimeter-wave discharge

Electron density and neutral gas density have been measured in a non-equilibrium air breakdown plasma using optical emission spectroscopy and two-dimensional laser interferometry, respectively. A plasma was created with a focused high frequency microwave beam in air. Experiments were run with 110 GHz and 124.5 GHz microwaves at powers up to 1.2 MW. Microwave pulses were 3 microsec. long at 110 GHz and 2.2 microsec. long at 124.5 GHz. Electron density was measured over a pressure range of 25 to 700 Torr as the input microwave power was varied. Electron density was found to be close to the critical density over the pressure range studied and to vary weakly with input power. Neutral gas density was measured over a pressure range from 150 to 750 Torr at power levels high above the threshold for initiating breakdown. The two-dimensional structure of the neutral gas density was resolved. Intense, localized heating was found to occur hundreds of nanoseconds after visible plasma formed. This heating led to neutral gas density reductions of greater than 80% where peak plasma densities occurred. Spatial and temporal structure of gas heating at atmospheric pressure were found to agree well with numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation and Structure of a Current Sheet in Pulsed-Power Driven Magnetic Reconnection Experiments

We describe magnetic reconnection experiments using a new, pulsed-power driven experimental platform in which the inflows are super-sonic but sub-Alfvenic. The intrinsically magnetised plasma flows are long lasting, producing a well-defined reconnection layer that persists over many hydrodynamic time scales. The layer is diagnosed using a suite of high resolution laser based diagnostics which provide measurements of the electron density, reconnecting magnetic field, inflow and outflow velocities and the electron and ion temperatures. Using these measurements we observe a balance between the power flow into and out of the layer, and we find that the heating rates for the electrons and ions are significantly in excess of the classical predictions. The formation of plasmoids is observed in laser interferometry and optical self-emission, and the magnetic O-point structure of these plasmoids is confrmed using magnetic probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme temperature robust optical sensor designs and fault-tolerant signal processing

Silicon Carbide (SiC) probe designs for extreme temperature and pressure sensing uses a single crystal SiC optical chip encased in a sintered SiC material probe. The SiC chip may be protected for high temperature only use or exposed for both temperature and pressure sensing. Hybrid signal processing techniques allow fault-tolerant extreme temperature sensing. Wavelength peak-to-peak (or null-to-null) collective spectrum spread measurement to detect wavelength peak/null shift measurement forms a coarse-fine temperature measurement using broadband spectrum monitoring. The SiC probe frontend acts as a stable emissivity Black-body radiator and monitoring the shift in radiation spectrum enables a pyrometer. This application combines all-SiC pyrometry with thick SiC etalon laser interferometry within a free-spectral range to form a coarse-fine temperature measurement sensor. RF notch filtering techniques improve the sensitivity of the temperature measurement where fine spectral shift or spectrum measurements are needed to deduce temperature.

47 OTHER INSTRUMENTATION↗