Search NASASearch

SEARCH · Search NASA

Results for “laser seeding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of a controllable particle generator for LV seeding in hypersonic wind tunnels

The paper describes the considerations that went into the development of a controllable particle generator for laser velocimeter seeding in a hypersonic wind tunnel operating at 3.45 million N/sq m, 533 K, and stream speed of about 1000 m/sec. Operating conditions determined the choice of a silicone oil as the material, and the requirement that the particle follow the flow within a certain accuracy range put constraints on the allowable particle size range. The principle of the particle generating device chosen was that of the LaMer generator, in which a liquid is first vaporized, mixed with the carrier gas, and then condensed under carefully controlled conditions. Preliminary results of studies on the effect of various apparatus parameters on the particle median diameter are given.

Feller, W. V.

OH Planar Laser Induced Fluorescence (PLIF) Measurements for the Study of High Pressure Flames: An Evaluation of a New Laser and a New Camera System

Planar laser induced fluorescence (PLIF) is used by the Combustion Branch at the NASA Glenn Research Center (NASA Glenn) to assess the characteristics of the flowfield produced by aircraft fuel injectors. To improve and expand the capabilities of the PLIF system new equipment was installed. The new capabilities of the modified PLIF system are assessed by collecting OH PLIF in a methane/air flame produced by a flat flame burner. Specifically, the modifications characterized are the addition of an injection seeder to a Nd:YAG laser pumping an optical parametric oscillator (OPO) and the use of a new camera with an interline CCD. OH fluorescence results using the injection seeded OPO laser are compared to results using a Nd:YAG pumped dye laser with ultraviolet extender (UVX). Best settings of the new camera for maximum detection of PLIF signal are reported for the controller gain and microchannel plate (MCP) bracket pulsing. Results are also reported from tests of the Dual Image Feature (DIF) mode of the new camera which allows image pairs to be acquired in rapid succession. This allows acquisition of a PLIF image and a background signal almost simultaneously. Saturation effects in the new camera were also investigated and are reported.

Tedder, Sarah

High Harmonic Generation Seeding Echo-Enabled Harmonic Generation toward a Storage Ring-Based Tender and Hard X-ray-Free Electron Laser

To align with the global trend of integrating synchrotron light source (SLS) and free electron laser (FEL) facilities on one site, in line with examples such as SPring-8 and SACLA in Japan and ELETTRA and FERMI in Italy, we actively explore FEL options leveraging the ultralow-emittance electron beam of the NSLS-II upgrade. These options show promising potential for synergy with storage ring (SR) operations, thereby significantly enhancing our facility’s capabilities. Echo-enabled harmonic generation (EEHG) is well-suited to SR-based FELs, and has already been demonstrated with the capability of generating extremely narrow bandwidth as well as high brightness, realized using diffraction-limited short pulses in transverse planes and Fourier transform-limited bandwidth in the soft X-ray spectrum. However, regarding a conventional EEHG scheme, the combination of the shortest seed laser wavelength (256 nm) and highest harmonic (200) sets the short wavelength limit to λ = 1.28 nm. To further extend the short wavelength limit down to the tender and hard X-ray region, a vital option is to shorten the seed laser wavelength. Thanks to recent advances in high harmonic generation (HHG), packing 10 9 photons at one harmonic within a few-femtosecond pulse could turn such a novel HHG source into an ideal seeding for EEHG. Thus, compared to the cascaded EEHG, the HHG seeding option could not only lower the cost, but also free the SR space for accommodating more user beamlines. Moreover, to mitigate the SASE background noise on the sample and detector, we combine the HHG seeding EEHG with the crab cavity short pulse scheme for maximum benefit.

36 MATERIALS SCIENCE

High Spectral Resolution Lidar Measurements Using an I2 Absorption Filter

The University of Wisconsin high spectral resolution lidar (HSRL) measures optical properties of the atmosphere by separating the Doppler-broadened molecular backscatter return from the unbroadened aerosol return. The HSRL was modified to use an I2 absorption cell The modified HSRL transmitter uses a continuously pumped, Q-switched, injection seeded, frequency doubled Nd:YAG laser operating at a 4 kHz pulse repetition rate. This laser is tunable over a 124 GHz frequency range by temperature tuning the seed laser under computer control.

Eloranta, E. W.

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers

Particle Streak Velocimetry of Supersonic Nozzle Flows

A novel velocimetry technique to probe the exhaust flow of a laboratory scale combustor is being developed. The technique combines the advantages of standard particle velocimetry techniques and the ultra-fast imaging capabilities of a streak camera to probe high speed flows near continuously with improved spatial and velocity resolution. This "Particle Streak Velocimetry" technique tracks laser illuminated seed particles at up to 236 picosecond temporal resolution allowing time-resolved measurement of one-dimensional flows exceeding 2000 m/s as are found in rocket nozzles and many other applications. Developmental tests with cold nitrogen have been performed to validate and troubleshoot the technique with supersonic flows of much lower velocity and without background noise due to combusting flow. Flow velocities on the order of 500 m/s have been probed with titanium dioxide particles and a continuous-wave laser diode. Single frame images containing multiple streaks are analyzed to find the average slope of all incident particles corresponding to the centerline axial flow velocity. Long term objectives for these tests are correlation of specific impulse to theoretical combustion predictions and direct comparisons between candidate green fuels and the industry standard, monomethylhydrazine, each tested under identical conditions.

Willits, J. D.

Seeding techniques used in the Vortex Research Facility

For many years, the Vortex Research Facility used kerosene vapor as seeding particles. The kerosene vapor formed (approx. 1 micron) particles initially. After injection into the test section, the vapor would begin to condense and form larger particles. By switching to solid particles, this has been eliminated. The uniform-sized (approx. 1 micron) solid particle seeding is used both to seed the Laser Velocimeter system and for flow visualization. After injection, the solid particles reach a uniform suspension before the vehicle is launched. It is found that the kerosene vapor poses a problem because it is a heated gas which modified the test section temperature distribution. It also produces high turbulence and secondary air currents because it was continually injected from the time of vehicle launch until model passage. In cases where the effects of either turbulence or the vertical temperature distribution are of interest, this hot gas injection method is unsuitable. Both types of seeding particles provide adequate flow visualization but are sensitive to vertical temperature distributions.

Satran, D. R.

Injection-seeded operation of a Q-switched Cr,Tm,Ho:YAG laser

Single-frequency Tm,Ho:YAG lasers operating near 2 microns are attractive sources for several applications including eye-safe laser radar (lidar) and pumping of AgGaSe2 parametric oscillators for efficient generation of longer wavelengths. As part of a program to develop a coherent lidar system using Tm,Ho:YAG lasers, a diode laser-pumped tunable CW single-longitudinal-mode (SLM) Cr:Tm:Ho:YAG laser and a flashlamp-pumped single-transverse-mode Q-switched Cr,Tm,Ho:YAG laser were developed. The CW laser was used to injection-seed the flashlamp-pumped laser, resulting in SLM Q-switched output. Operational characteristics of the CW and Q-switched lasers and injection-seeding results are reported.

Henderson, Sammy W.

Frequency stabilization and transverse mode discrimination in injection-seeded unstable resonator TEA CO2 lasers

Longitudinal mode selection by injection has been demonstrated as a viable technique for TEA-CO2 lasers with pulse energies of a Joule or greater. Once reliable generation of single-longitudinal-mode (SLM) pulses is obtained, the characteristics and the causes of intrapulse frequency variation can be studied. These include the effect of the decaying plasma, the thermal gradient due to the energy dissipation associated with the laser mechanism itself, and the pressure shift of the center frequency of the laser transition. The use of the positive-branch unstable resonator as an efficient means of coupling a discharge with large spatial dimensions to an optical cavity mode introduces another concern: namely, what can be done to emphasize transverse mode discrimination in an unstable resonator cavity while maintaining high coupling efficiency. These issues are discussed in this paper, and relevant experimental results are included.

Ancellet, G. M.

Demonstration of frequency control and CW diode laser injection control of a titanium-doped sapphire ring laser with no internal optical elements

Theoretical and experimental frequency narrowing studies of a Ti:sapphire ring laser with no intracavity optical elements are reported. Frequency narrowing has been achieved using a birefringent filter between a partially reflecting reverse wave suppressor mirror and the ring cavity output mirror. Results of CW diode laser injection seeding are reported.

Bair, Clayton H.

The development of a 3-D laser velocimeter for the NASA Langley low turbulence pressure wind tunnel

The design of an orthogonal, three-dimensional laser velocimeter with in situ sizing (LVIS) system for a high-Reynolds-number facility, the NASA Langley low turbulence pressure wind tunnel (LTPT), is discussed. Special attention is paid to the laser velocimeter seeding subsystems, while all other subsystems are approached from the users standpoint. The evaluation of the LVIS system leads to the conclusion that seeding of large scale pressure wind tunnels remains a problem, while using the polydispersed seeding requires further investigation. A Cassegrain mirror receiver optics may be successfully implemented in lieu of similar lens systems. General agreement is observed between the mean velocity LVIS measurements as compared to conventional pitot and hot-wire data.

Jones, Gregory S.

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimetric (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single CW laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640 x 480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.

Full field gas phase velocity measurements in microgravity

Measurement of full-field velocities via Particle Imaging Velocimetry (PIV) is common in research efforts involving fluid motion. While such measurements have been successfully performed in the liquid phase in a microgravity environment, gas-phase measurements have been beset by difficulties with seeding and laser strength. A synthesis of techniques developed at NASA LeRC exhibits promise in overcoming these difficulties. Typical implementation of PIV involves forming the light from a pulsed laser into a sheet that is some fraction of a millimeter thick and 50 or more millimeters wide. When a particle enters this sheet during a pulse, light scattered from the particle is recorded by a detector, which may be a film plane or a CCD array. Assuming that the particle remains within the boundaries of the sheet for the second pulse and can be distinguished from neighboring particles, comparison of the two images produces an average velocity vector for the time between the pulses. If the concentration of particles in the sampling volume is sufficiently large but the particles remain discrete, a full field map may be generated.

Griffin, Devon W.

Diode-pumped Ho:Tm:YLF laser pumping and AgGaSe2 parametric oscillator

Tuning of both the pump laser, a Ho:Tm:YLF laser operating on the 5 I 7 - 5 I 8 transition, and an AgGaSe2 parametric oscillator has been demonstrated. Tuning of the Ho:Tm:YLF laser is complicated but not frustrated by the existence of both CO2 and H2O lines in the vicinity of the laser transition. Tuning of the parametric oscillator was achieved by tuning of the pump laser. Injection seeding of the parametric oscillator on the nonresonant signal was also demonstrated. In addition, the measured efficiencies of the parametric oscillator were compared by two different methods, measuring the parametric-oscillator output energy and measuring the energy depleted from the pump. By comparison of these measurements, the intrinsic efficiency of the parametric oscillator cab be determined

Barnes, Norman P.

TPSAS-NF1676L-11308-DND

The Lidar Atmospheric Sensing Experiment (LASE) system has operated on the NASA ER-2, P-3, and DC-8 aircraft during the past 16 years and participated in 13 field experiments. This system provides vertical profiles of water vapor mixing ratio and aerosol and cloud backscattering. A brief overview is presented on the upgrade of LASE that included refurbishment of laser diode seeding, control and data system, and zenith receiver system. These developments have enhanced the operational reliability of the system and improved its performance. The LASE system was deployed on the NASA DC-8 aircraft recently for the NASA GRIP (Genesis and Rapid Intensification Processes) field experiment, which was conducted during August and September 2010 from operational bases in Fort Lauderdale, FL and St. Croix, VI. Initial measurements from this field experiment are presented including distributions of water vapor, aerosol, and clouds. Temperature profiles from DC-8 dropsondes and nearby radiosondes are used to derive relative humidity profiles from the LASE water vapor mixing ratio profiles. Comparisons of LASE water vapor mixing ratio profiles with those measured by the new AVAPS-II dropsondes from the NASA DC-8 are also presented.

Susan A Kooi

Seeding Method for Velocimetry and Visualization of Supersonic Retropropulsion Nozzle Plumes

In the current work, the “Venturi seeder” method for nozzle plumes is improved and studied to determine suitability for particle image velocimetry. This seeding method involves independently pressurizing the primary flow path and a separate seed liquid reservoir, connecting them at the throat of a Venturi contraction upstream of the nozzle. The pressure differential at the throat causes the liquid to enter the nozzle channel where it is atomized into particles by strong shearing forces. This new seeding system was characterized by conducting a series of diagnostics using different exit nozzle pressure ratios and seed reservoir pressures. Shadowgraph imaging confirmed the nozzle plumes to be underexpanded jets. A particle sizing device determined that generated DEHS oil particles had median aerodynamic diameters of 0.67, 0.69, and 0.73 μm for seed liquid reservoir pressure supplies of 0.67, 0.60, and 0.93 MPa and primary flow path pressures of 0.67, 0.76, and 0.93 MPa measured downstream of the Venturi throat, respectively. These diameters were within the threshold for acceptable response time in typical gas flows (≤ 1 μm). PIV experiments were conducted on the nozzle plume for all presented cases; mean axial and transverse velocities appeared as expected for the underexpanded jet structure, including the Mach disk and re-acceleration regions. Additional sizing analysis based on the particle response times across the normal shock again showed particle diameters to be well less than 1 μm for all cases. The results suggest that this method is an inexpensive and relatively simple solution to the problem of seeding nozzle plumes. The method will be used in testing of supersonic retropropulsion models in the Unitary Plan Wind Tunnel at The NASA Langley Research Center in 2022.

particle image velocimetry

Solid state laser

A wavelength-tunable, injection-seeded, dispersion-compensated, dispersively-pumped solid state laser includes a lasing medium; a highly reflective mirror; an output coupler; at least one isosceles Brewster prism oriented to the minimum deviation angle between the medium and the mirror for directing light of different wavelengths along different paths; means for varying the angle of the highly reflective mirror relative to the light from at least one Brewster angle for selecting a predetermined laser operating wavelength; a dispersion compensation apparatus associated with the lasing medium; a laser injection seeding port disposed between the dispersion compensation apparatus and one of the mirror and coupler and including a reflective surface at an acute non-Brewster angle to the laser beam for introducing a seed input; a dispersion compensation apparatus associated with the laser medium including opposite chirality optical elements; the lasing medium including a pump surface disposed at an acute angle to the laser beam to define a discrete path for the pumping laser beam separate from the pumped laser beam.

Rines, Glen A.