Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Feasibility of using distributed chemical sensing for CO2 leakage monitoring

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CCS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed using optical spectroscopy in optical fiber for direct detection of CO 2 . The main approach is based on Raman interrogation within gas-filled Holey Fibers (HoFs), so that the location and concentration of the gases would be provided simultaneously via backscattering. Additionally, Infrared (IR) Absorption Spectroscopy could also be used, and the architecture would be more discrete since interleaving with standard solid core fibers and Fiber Bragg Grating (FBG) sections is required to enable reflection to the I/O controls. The possible Raman length or the IR numbers of sections would be defined based on signal to noise ratio. The optical spectroscopy methodology would overcome current roadblocks to CCS, as fiber optics will allow for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of using distribute chemical sensing for CO2 leakage monitoring

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with standard solid core fibers and Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously by means of reflectometry. The methodology would overcome current roadblocks to using fiber optics for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

54 ENVIRONMENTAL SCIENCES↗

Virtual refrigerant charge sensing algorithm for residential CO₂ heat pumps

Natural refrigerants are increasingly adopted in next-generation heat pump systems, among which CO₂ heat pumps have attracted significant attention. However, due to their high operating pressures, the leakage risk is higher, resulting in undercharge conditions and degraded heat pump performance. Thus, developing an accurate refrigerant charge level detection technique is necessary to guarantee safe and efficient operation. Although virtual refrigerant charge (VRC) level calculation algorithms for CO₂ heat pumps exist, they typically rely on empirically selected features without a systematic selection framework, leading to multicollinearity and potential overfitting, which limit their prediction accuracy and generalizability. To address these issues, this study proposes a VRC algorithm framework with a systematic feature selection method that identifies physically meaningful and statistically significant features, and is applied using a residential CO₂ heat pump as a case study. The method is extended from previous work on conventional refrigerants to account for charge behavior in CO₂ gas coolers. The selected features include gas cooler outlet density, evaporator pressure, and superheat temperature. The results demonstrate that the proposed feature selection method significantly improves prediction accuracy compared to existing VRC approaches. A relatively small training dataset (∼30 samples) is sufficient for feature identification and model development. The developed algorithm achieves less than 3% prediction error under both undercharge and overcharge conditions, representing reductions of 46.7% and 35.3% compared to two recent reference VRC algorithms for transcritical CO₂ heat pumps reported in the literature. The proposed algorithm and feature selection method enhance leakage detection capability, facilitate the deployment of CO₂ heat pump systems, and contribute to reduced energy waste and maintenance costs.

Guo, Fangzhou [Lawrence Berkeley National Laborato↗

LLNL Kimberlina 1.2 NUFT Simulations June 2018 (v2)

This dataset contains the output 6,000, 3-dimensional reactive multi-phase flow and transport aquifer simulations of brine and CO2 leakage into a protective aquiver in California’s San Joaquin Valley and input data files detailing the geologic mesh, aquifer physical properties and CO2 and brine injection rates. This data set was generated as an ongoing effort with the US DOE National Risk Assessment Partnership (NRAP) to evaluate the effectiveness of monitoring techniques to detect brine and CO2 leakage from legacy wells into underground sources of drinking water overlaying a CO2 storage reservoir. Each simulation contains a unique set of input parameters, generated stochastically. The outputs consist of these upper three geologic layers (from top): the Etchegoin, Macoma-Chanac, Santa Margarita-McLure formations. These simulations span the several distances (1, 3 and 6 km or wells W31-0.2, W31-0.5 and W31-1.0, respectively) from the CO2 injector, initiated from bottom hole pressure and saturation to calculate wellbore leakage from the storage reservoir, with low and high regional groundwater gradients and wellbore leakage into 5 leaky nodes. The dataset includes 1,000 unique simulations for each distance, which each contain a unique aquifer heterogeneity, aquifer and caprock permeability, and two model generations are included with a high permeability (prod07) and hybrid permeability (prod09). The range of permeability distributions is listed in Table 1. Each model generation consists of 3,000 simulations. Included in the dataset are the leakage rates determined from 2D wellbore models which utilize the pressure and CO2 saturation from LBL's reservoir simulations, NUFT mesh files with distributed lithology, NUFT rocktab files which describe the material properties for the geologic layers and the NUFT input files and post-processed output 'ntab' files. Each ntab file contains spatial (rows) and temporal (columns) model output tables for each model cell, the locations (x,y,z) and dimensions for each cells (dx, dy, dz). Table 1. Permeability distribution ranges for prod07 and prod09 model generations Geologic Layer: Permeability Range (log10 m^2) prod07 prod09 Etchegoin -12.92 to -10.92 -13.70 to -11.44 Macoma-Chanac -12.72 to -10.72 -13.50 to -11.24 Santa Margarita-McLure -12.70 to -10.70 -13.48 to -11.22 The input files used to generate the model include which are included in the dataset are: Time series of CO2 leakage input into the model (ex: Q_brn.W31-0.2.sim1000.layers123.tab) Time series of CO2 leakage input into the model (ex: Q_CO2.W31-0.2.sim1000.layers123.tab) Physical properties of the aquifer materials detailing the aquifer porosity, solid density, partitioning coefficients, permeabilities and van-Genuchten parameters detailed in a NUFT rocktab file: (ex: sim1000.usnt.rocktab) Numerical mesh and geologic data assigned to each model cell detailed in a NUFT genmsh format (ex: sim1000.mesh_k16.prod07.trans.genmsh) The primary output parameters are: pH (use absolute value) Change in TDS (mg/kg) Change in Pressure (Pa) Change CO2 gas saturation (fraction range 0.0-1.0) for example, the directory /p/lscratchh/mansoor1/nrap/kimberlina/prod09/mainfiles/sim1000/W31- 0.2 contains: sim1000.W31-0.2.trans.pH.red.ntab sim1000.W31-0.2.no_bg.trans.TDS.red.ntab sim1000.W31-0.2.usnt.P.deltabg.red.ntab sim1000.W31-0.2.usnt.CO2_sat.deltabg.red.ntab Each row in the NTAB files consist of model output per numerical grid cell. Each output file contains 33 columns (variables), including the information of numerical records, geologic location and sizes and the simulated parameter values over time. The first 13 variables are about numerical records and relative geologic information for a simulation grid: 1. index: simulation index 2. i: the ith grid of x-axis 3. j: the ith grid of y-axis 4. k: the ith grid of z-axis 5. element_ref: element reference 6. nuft_ind: nuft index 7. x: grid location in the x axis direction 8. y: grid location in the y axis direction 9. z: grid location in the z axis direction 10. dx: grid length in the x axis direction 11. dy: grid length in the y axis direction 12. dz: grid length in the z axis direction 13. volume: volume of the simulation grid The remainder (14, 15, 16...) variables are the simulated parameter values over time, take Pressure as an example, are: 14. 0.0y: initial pressure per cell. 15. 10.0y: simulated pressure at the end of the 10th year. 16. 20.0y: simulated pressure at the end of the 20th year. ... (repeated for every 10 years until 200 years)... The model extends 10,000 m, 5,000 m and 1,411 m in the x,y and z dimensions, respectively. The mesh consists of 164,832 cells with mesh dimensions of 101 x 51 x 32 (nx, ny, nz), with cell dimensions ranging from 100 m laterally (along x and y-axis) and model layers are as designated in the z-axis: Layer 1: atmosphere (1e-30 m thick) Layer 2: upper caprock (10 m thick) Layers 3-13: Etchegoin (536.23 m thck) Layers 14-27: Macoma-Chanac (679.04 m thick) Layers 28-32: Santa Margarita-McLure (185.94 m thick) The wellbore is placed along node i=51, j=26, and extends vertically along 5 nodes from the top to the bottom of the model. Special instructions when extracting files: Each Gzip archive (ex: prod07.sim1000-sim00099.tar.gz) contains 100 simulations. Gzip archives should be transferred into base directories (ie. In Linux: mkdir prod07; mv prod07.*.tar.gz prod07/.) before extracting, or files will be overwritten. Each sub-simulation tree should have the following file structure pattern (using the linux 'tree' command): |-- prod07 | |-- sim0001 | |-- W31-0.2 | | |-- Q_brn.W31-0.2.sim0001.layers123.tab | | |-- Q_co2.W31-0.2.sim0001.layers123.tab | | |-- sim0001.W31-0.2.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.2.trans.pH.red.ntab | | |-- sim0001.W31-0.2.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.2.usnt.P.deltabg.red.ntab | |-- W31-0.5 | | |-- Q_brn.W31-0.5.sim0001.layers123.tab | | |-- Q_co2.W31-0.5.sim0001.layers123.tab | | |-- sim0001.W31-0.5.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.5.trans.pH.red.ntab | | |-- sim0001.W31-0.5.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.5.usnt.P.deltabg.red.ntab | |-- W31-1.0 | | |-- Q_brn.W31-1.0.sim0001.layers123.tab | | |-- Q_co2.W31-1.0.sim0001.layers123.tab | | |-- sim0001.W31-1.0.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-1.0.trans.pH.red.ntab | | |-- sim0001.W31-1.0.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-1.0.usnt.P.deltabg.red.ntab | |-- sim0001.mesh_k16.prod07.trans.genmsh Disclaimer This document was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor Lawrence Livermore National Security, LLC, nor any of their employees makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or Lawrence Livermore National Security, LLC. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or Lawrence Livermore National Security, LLC, and shall not be used for advertising or product endorsement purposes. Lawrence Livermore National Laboratory is operated by Lawrence Livermore National Security, LLC, for the U.S. Department of Energy, National Nuclear Security Administration under Contract DE-AC52-07NA27344. This report was reviewed and released as LLNL-MI-753464.

aquifer↗

Empirical Bounding Analysis and User Recommendations for a Neutron Multiplicity Detector

Neutron multiplicity detectors are useful for a variety of applications including nuclear emergency response, nuclear nonproliferation, safeguards, and criticality safety. When measuring black-box problems (i.e., when the system being measured is completely unknown) with systems that have relatively low detection efficiency, expert analysis is frequently required to determine appropriate bounds for system parameters such as neutron multiplication and neutron leakage. This is because the detection efficiency can vary wildly, which also means that the resulting system parameters can have large variations. This work applies an empirical approach to provide bounds on system parameters (such as system multiplication, neutron leakage, and detector efficiency). The results of this bounding analysis are then used as inputs to provide recommendations to users regarding criticality safety. In addition to describing the method used, this work provides sample results from a measurement campaign performed at the National Criticality Experiments Research Center (NCERC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing spatiotemporal forecasts of CO 2 plume migration using deep learning networks with transfer learning and interpretation analysis

Accurate and timely forecasts of CO 2 plume distribution throughout the injection and post-injection phases are crucial for detecting plume migration, assessing leakage risks, and supporting operational decisions in geologic carbon storage (GCS). Current convolutional neural network-based approaches primarily focus on spatial information and overlook temporal dependencies in plume distributions, thus limiting their ability to capture dynamic movement effects and provide accurate predictions of plume migration. In this work, we propose two deep learning models, Auto-Encoder (AE)-LSTM and Encoder-Decoder (ED)-ConvLSTM, each uniquely designed to capture both spatial and temporal features. We apply the proposed methods to forecast the dynamic distribution of CO 2 plumes based on 108 reservoir simulations over a 30-year injection and a 30-year post-injection period. The results indicate that the ED-ConvLSTM model outperforms the AE-LSTM model in accurately predicting the spatiotemporal dynamics of CO 2 plume migration, achieving R 2 values above 0.99. To provide a deeper understanding of these model predictions, we employ a gradient-based explanation method on the trained models. This approach provides insights into the influence of input variables on plume migration forecasts and uncovers the underlying prediction mechanisms of the proposed models. Furthermore, we introduce a transfer learning technique, enabling fast and accurate plume migration forecasting in the post-injection phase by leveraging the trained model during the injection phase. This reduces the necessity for extensive data collection or re-training. In conclusion, the methods proposed in our work enhances the performance and interpretability of CO 2 plume migration forecasts, thereby facilitating informed decision-making throughout the entire lifecycle of GCS applications.

58 GEOSCIENCES↗

Data-assimilated time-lapse visco-acoustic full-waveform inversion: Theory and application for injected CO 2 plume monitoring

Continuous seismic monitoring for quantifying CO 2 plume migration and detection of any potential leakages in the subsurface is essential for the security of long-term anthropogenic carbon dioxide geologic storage. Traditional time-lapse full-waveform inversion (TLFWI) methods aim to map the CO 2 distribution by estimating seismic velocity changes, but recent studies find that CO 2 -induced attenuation is an important complement to seismic velocity for tracking the CO 2 plumes and even quantifying the CO 2 saturation. We have developed a novel data-assimilated TLFWI method to construct high-resolution time-lapse velocity and attenuation changes from dense time-lapse monitoring data. This method consists of two theoretical developments: visco-acoustic full-waveform inversion (QFWI) and multiparameter hierarchical matrix-powered extended Kalman filter (mHiEKF). The method is capable of (1) posing temporal constraints to retrieve time-lapse information from dense monitoring data by using mHiEKF, (2) accurately recovering high-spatial-resolution velocity and attenuation perturbations using first-order equation system-based QFWI, and (3) providing the model uncertainty by estimating their model standard deviation. With numerical examples, we first find the effectiveness of the new QFWI on estimating accurate velocity and attenuation models simultaneously. Then, a CO 2 leakage case and a realistic Frio-II CO 2 monitoring case are presented to find the advantages and applicability of our data-assimilated QFWI method for estimating time-lapse changes using dense time-lapse monitoring surveys. Here, by assimilating time-lapse seismic monitoring data over time, our data-assimilated QFWI method can improve the resolution of velocity and attenuation changes and decrease their model uncertainties.

58 GEOSCIENCES↗

Integration of seismic-pressure-petrophysics inversion of continuous active-seismic monitoring data for monitoring and quantifying CO 2 plume (Final Report)

The overall objective of this project is to develop and validate an integrated package of joint seismic-pressure-petrophysics inversion (jSPPI) of continuous active-source seismic monitoring dataset capable of providing real-time monitoring of CO 2 plume during geologic carbon sequestration (GCS). The three specific developments include: (a) the methodologies for fast seismic full waveform inversion of continuous active source seismic monitoring, (CASSM) datasets for simultaneously estimating velocity and attenuation, and with data assimilation; (b) joint Bayesian petrophysical inversion of seismic models and pressure data for providing and updating CO 2 saturation models; (c) the methods using multiple datasets including (Crainfield and Frio-II borehole) synthetic, laboratory, and field CASSM datasets. The outcomes of jSPPI include (a) a workflow for processing CASSM data, (b) Bayesian inversion algorithms using CASSM data and pressure response data, and (c) integration with data assimilation algorithms for continuously updating site-specific models used for prediction and reservoir management. The validation of joint FWI will be conducted using synthetic models based on the Cranfield and Frio experiments as well as field CASSM datasets collected as part of the Frio-II pilot injection. To quantify and map the mass and distribution of CO 2 (saturation), we will jointly invert velocity and attenuation measurements from the FWI with a Bayesian approach using a rock physics model for attenuation (e.g., White’s attenuation model with two selected patch sizes (White, 1976; Dutta and Seriff, 1979)). The Bayesian inversion will be applied to each time step in the CASSM survey in an updating scheme, which integrates with an ensemble of reservoir simulations at each step. A more complete experimental validation dataset will be collected as part of a mesoscale (2-3 m) gas-CO 2 injection experiment utilizing a higher frequency version of the CASSM system developed for laboratory studies; the integrated inversion will be demonstrated using this dataset which will provide both a dense geometry as well as more precise secondary confirmation measurements (e.g. saturation) typically not available in the field. The resulting real-time map of CO 2 saturation is able to provide a deeper scientific understanding of the complex, time-varying dynamics of subsurface fluid flow migration path as well as the rapid detection of CO 2 leakage hazards.

25 ENERGY STORAGE↗

Forest Carbon Emissions from Cropland Expansion in the Brazilian Cerrado Biome

Land use, land use change, and forestry accounted for two-thirds of Brazil's greenhouse gas emissions profile in 2005. Amazon deforestation has declined by more than 80% over the past decade, yet Brazil's forests extend beyond the Amazon biome. Rapid expansion of cropland in the neighboring Cerrado biome has the potential to undermine climate mitigation efforts if emissions from dry forest and woodland conversion negate some of the benefits of avoided Amazon deforestation. Here, we used satellite data on cropland expansion, forest cover, and vegetation carbon stocks to estimate annual gross forest carbon emissions from cropland expansion in the Cerrado biome. Nearly half of the Cerrado met Brazil's definition of forest cover in 2000 (greater than or equal to 0.5 ha with greater than or equal to 10% canopy cover). In areas of established crop production, conversion of both forest and non-forest Cerrado formations for cropland declined during 2003-2013. However, forest carbon emissions from cropland expansion increased over the past decade in Matopiba, a new frontier of agricultural production that includes portions of Maranhao, Tocantins, Piau­, and Bahia states. Gross carbon emissions from cropland expansion in the Cerrado averaged 16.28 Tg C yr (exp -1) between 2003 and 2013, with forest-to-cropland conversion accounting for 29% of emissions. The fraction of forest carbon emissions from Matopiba was much higher; between 2010-2013, large-scale cropland conversion in Matopiba contributed 45% of total Cerrado forest carbon emissions. Carbon emissions from Cerrado-tocropland transitions offset 5-7% of the avoided emissions from reduced Amazon deforestation rates during 2011-2013. Comprehensive national estimates of forest carbon fluxes, including all biomes, are critical to detect cross-biome leakage within countries and achieve climate mitigation targets to reduce emissions from land use, land use change, and forestry.

remote sensing↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas leak-detection system

Data monitoring of gas leakage in satellites and spacecraft is facilitated by adding gaseous radioisotopes to cold compressed gas and mounting a detector in the thrust nozzle.

Roselli-Lorenzini, F. G.↗

Integrated CMOS photodetectors and signal processing for very low-level chemical sensing with the bioluminescent bioreporter integrated circuit

We report an integrated CMOS microluminometer optimized for the detection of low-level bioluminescence as part of the bioluminescent bioreporter integrated circuit (BBIC). This microluminometer improves on previous devices through careful management of the sub-femtoampere currents, both signal and leakage, that flow in the front-end processing circuitry. In particular, the photodiode is operated with a reverse bias of only a few mV, requiring special attention to the reset circuitry of the current-to-frequency converter (CFC) that forms the front-end circuit. We report a sub-femtoampere leakage current and a minimum detectable signal (MDS) of 0.15 fA (1510 s integration time) using a room temperature 1.47 mm2 CMOS photodiode. This microluminometer can detect luminescence from as few as 5000 fully induced Pseudomonas fluorescens 5RL bacterial cells. c2002 Elsevier Science B.V. All rights reserved.

Non-NASA Center↗

Propellant Feed System Leak Detection: Lessons Learned From the Linear Aerospike SR-71 Experiment (LASRE)

This paper presents pertinent results and assessment of propellant feed system leak detection as applied to the Linear Aerospike SR-71 Experiment (LASRE) program flown at the NASA Dryden Flight Research Center, Edwards, California. The LASRE was a flight test of an aerospike rocket engine using liquid oxygen and high-pressure gaseous hydrogen as propellants. The flight safety of the crew and the experiment demanded proven technologies and techniques that could detect leaks and assess the integrity of hazardous propellant feed systems. Point source detection and systematic detection were used. Point source detection was adequate for catching gross leakage from components of the propellant feed systems, but insufficient for clearing LASRE to levels of acceptability. Systematic detection, which used high-resolution instrumentation to evaluate the health of the system within a closed volume, provided a better means for assessing leak hazards. Oxygen sensors detected a leak rate of approximately 0.04 cubic inches per second of liquid oxygen. Pressure sensor data revealed speculated cryogenic boiloff through the fittings of the oxygen system, but location of the source(s) was indeterminable. Ultimately, LASRE was cancelled because leak detection techniques were unable to verify that oxygen levels could be maintained below flammability limits.

Hass, Neal↗

Prediction of Leakage Current and Depletion Voltage in Silicon Detectors Under Extraterrestrial Radiation Conditions

Silicon detection is a mature technology for registering the passage of charged particles. At the same time it continues to evolve toward increasing radiation tolerance as well as precision and adaptability. For these reasons it is likely to remain a critical element of detection of systems associated with extraterrestrial exploration. Silicon sensor leakage current and depletion voltage depend on the integrated fluence received by the sensor and on its thermal history during and after the irradiation process. For minimal assumptions on shielding and hence on the particle energy spectrum, and using published data on Martian ground temperature, we predict the leakage current density and the depletion voltage, as a function of time, of silicon sensors in transit to and deployed continuously on the Mars surface for a duration of up to 28 Earth-years, for several sensor geometries and a worst-case temperature scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High levels of exfoliated fragments following glycocalyx destruction in hemorrhagic fever with the renal syndrome are associated with mortality risk

Background The glycocalyx is a gel-like structure that covers the luminal side of vascular endothelial cells. It plays an important role in maintaining the integrity of the vascular endothelial barrier structure. However, the presence or absence of glycocalyx destruction in hemorrhagic fever with renal syndrome (HFRS) and its specific mechanism and role is still unclear. Methods In this study, we detected the levels of exfoliated glycocalyx fragments, namely, heparan sulfate (HS), hyaluronic acid (HA), and chondroitin sulfate (CS), in HFRS patients and investigated their clinical application value on the evaluation of disease severity and prognosis prediction. Results The expression of exfoliated glycocalyx fragments in plasma was significantly increased during the acute stage of HFRS. The levels of HS, HA, and CS in HFRS patients during the acute stage were significantly higher than in healthy controls and convalescent stages of the same type. HS and CS during the acute stage gradually increased with the aggravation of HFRS, and both fragments showed a significant association with disease severity. In addition, exfoliated glycocalyx fragments (especially HS and CS) showed a significant correlation with conventional laboratory parameters and hospitalization days. High levels of HS and CS during the acute phase were significantly associated with patient mortality and demonstrated an obvious predictive value for the mortality risk of HFRS. Conclusion Glycocalyx destruction and shedding may be closely associated with endothelial hyperpermeability and microvascular leakage in HFRS. The dynamic detection of the exfoliated glycocalyx fragments may be beneficial for the evaluation of disease severity and prognosis prediction in HFRS.

Du, Hong↗

Fluid leakage detector for vacuum applications

A leak detection system for use with a fluid conducting system in a vacuum environment, such as space, is described. The system preferably includes a mesh-like member substantially disposed about the fluid conducting system, and at least one sensor disposed within the mesh-like member. The sensor is capable of detecting a decrease in temperature of the mesh-like member when a leak condition causes the fluid of the fluid conducting system to freeze when exposed to the vacuum environment. Additionally, a signal processor in preferably in communication with the sensor. The sensor transmits an electrical signal to the signal processor such that the signal processor is capable of indicating the location of the fluid leak in the fluid conducting system.

Farkas, Tibor↗

Seismic H2: Version 1.0

Seismic-H2 is an integrated software package for geological hydrogen reservoir simulation, optimization, and leakage monitoring. The package includes multiple components: (1) code used for modeling seismic wave propagation in 3D heterogeneous elastic media based on finite-difference method to support detection of geological hydrogen storage reservoir leakage; (2) 3D reservoir simulations of leaks from an underground reservoir and 3D simulations of saline aquifers and depleted gas reservoirs; (3) seismic monitoring costs of passive and active seismic monitoring required for UHS; (4) rock physics calculations and interpolations for converting the reservoir simulations from part (2) into the elastic media models in part (1); (5) pre-processing seismic data; and lastly (6), a GUI interface that combines these different components.

Creasy, Neala↗