Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of possible reactivation of undetected faults during CO 2 injection

Geologic storage of carbon dioxide can efficiently contribute to reduce greenhouse gas emissions to the atmosphere. Two major hazards of this technology are leakage towards the ground surface and fluid-induced seismicity. While major faults may be detected and avoided during site characterization, undetected subseismic faults could be encountered once injection has started. This paper investigates leakage and reactivation of undetected faults through coupled thermal–hydraulic–mechanical modeling. The simulations are performed using a recently developed sequential simulator, TOUGH-Pylith, that allows to accurately account for the thermodynamics of brine-CO 2 injection mixtures, and to model faults as surfaces of discontinuity using state-of-the-art fault friction laws. The simulator is benchmarked against well-known analytical solutions and subsequently applied to investigate two cases of CO 2 injection injection close to undetected faults under normal and strike-slip faulting regimes. Furthermore, although the scenarios are generic and represent unfavorable conditions, they suggest that leakage could occur and that undetected faults could trigger minor seismic events. Therefore, careful site characterization and continuous monitoring during operations should be always performed.

58 GEOSCIENCES↗

Design Choices in Anomaly Detection for Industrial Control Systems: Insights from Gas Pipeline Data

Industrial control systems (ICS) remain vulnerable to increasingly sophisticated cyberattacks, yet evaluating anomaly detection models in these environments is challenging due to temporal dependencies, missing-not-at-random patterns, and extremely imbalanced datasets. These factors make common practices—especially random data splits and naïve imputation—prone to severe temporal leakage, which can inflate reported performance and obscure real-world limitations. In this work, we systematically examine classical machine learning models, temporal deep learning architecture, and tensor-decomposition–based methods on a gas-pipeline dataset using a fully temporally separated evaluation pipeline designed to mimic realistic deployment conditions. Our findings show that proper temporal handling and MNAR-aware preprocessing significantly alter the relative performance of popular anomaly-detection methods, providing practical guidance for designing reliable, leakage-resistant ICS intrusion-detection systems.

97 MATHEMATICS AND COMPUTING↗

The Impact of Time-Aware Design Choices in ICS Anomaly Detection

Industrial control systems (ICS) remain vulnerable to increasingly sophisticated cyberattacks, yet evaluating anomaly detection models in these environments is challenging due to temporal dependencies, missing-not-at-random patterns, and extremely imbalanced datasets. These factors make common practices—especially random data splits and na¨ıve imputation— prone to severe temporal leakage, which can inflate reported performance and obscure real-world limitations. In this work, we systematically examine classical machine learning models, temporal deep learning architecture, and tensordecomposition– based methods on a gas-pipeline dataset using a fully temporally separated evaluation pipeline designed to mimic realistic deployment conditions. Our findings show that proper temporal handling and MNAR-aware preprocessing significantly alter the relative performance of popular anomaly-detection methods, providing practical guidance for designing reliable, leakage-resistant ICS intrusion-detection systems.

97 MATHEMATICS AND COMPUTING↗

Experimental study on nanoparticle injection by using a lab-scale wellbore system

After long-term underground storage of CO 2 gas, leakage generated from the cement annulus in the wellbore system is often detected due to unbalanced pressure, chemical attack, etc. Here in this paper, nanoparticle injection technology is introduced to inject different types of nanoparticles into the cementitious material for repairing the leakage paths through electrochemical means. The pressure vessel is designed and built to provide a realistic underground environment with high pressure and high temperature. The testing results are evaluated by the saturate-drying method, charge-passed method, and X-ray microscopy (XRM) test. The results consistently show that all types of nanoparticles tested in this paper can be successfully driven into the cement annulus within the wellbore system. The pressure (6.89 MPa) and temperature (80 °C) in the pressure vessel, and the surrounding rock can directly affect the injection effectiveness. The nanoparticle injection technology is proven to be beneficial to the cracked cement annulus for preventing the leakage of CO 2 gas through the lab-scale wellbore system.

36 MATERIALS SCIENCE↗

Temperature-dependent charge barrier height of amorphous germanium contact detector

The exploration of germanium (Ge) detectors with amorphous Ge (a-Ge) contacts has drawn attention to the searches for rare-event physics such as dark matter and neutrinoless double-beta decay. The charge barrier height (CBH) of the a-Ge contacts deposited on the detector surface is crucial to suppress the leakage current of the detector in order to achieve a low-energy detection threshold and high-energy resolution. The temperature-dependent CBH of a-Ge contacts for three Ge detectors is analyzed to study the bulk leakage current (BLC) characteristics. The detectors were fabricated at the University of South Dakota using homegrown crystals. The CBH is determined from the BLC when the detectors are operated in the reverse bias mode with a guard-ring structure, which separates the BLC from the surface leakage current (SLC). Here the results show that CBH is temperature dependent. The direct relation of the CBH variation to temperature is related to the barrier inhomogeneities created on the interface of a-Ge and crystalline Ge. The inhomogeneities that occur at the interface were analyzed using the Gaussian distribution model for three detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Frequency Conversion in High-Q Superconducting Resonators: Axion Electrodynamics, QED, and Nonlinear Meissner Radiation

High-Q superconducting resonators have been proposed and developed as detectors of light-by-light scattering mediated by the hypothesized axion or virtual electron–positron pairs in quantum electrodynamics: the Euler–Heisenberg (EH) interaction. Photon frequency and mode conversion is central to the scheme for detecting such rare events. Superconducting resonators are nonlinear devices. The Meissner screening currents that confine the electromagnetic fields to the vacuum region of a superconducting RF cavity are nonlinear functions of the EM field at the vacuum–superconducting interface, and as a result can generate source currents and frequency conversion of microwave photons in the cavity. In this report we consider photon frequency and mode conversion in superconducting resonators with high quality factors from Meissner currents in single- and dual-cavity setups proposed for axion and QED searches based on light-by-light scattering. In a single cavity with two pump modes, photon frequency conversion by the Meissner screening current dominates photon generation by the EH interaction for cavities with Q≲1012⁠. The Meissner currents also generate background photons that limit the operation of the resonator for axion detection in three-mode, single-cavity setups. We also consider the leakage of photons from pump modes into the signal mode for both axion- and EH-mediated light-by-light scattering. Photon frequency conversion by the EH interaction can compete with Meissner and leakage radiation in ultra-high-Q cavities that are beyond the current state of the art. Meissner radiation and leakage backgrounds can be suppressed in dual-cavity setups with appropriate choices for pump and spectator modes, as well as the single-cavity setup proposed for heterodyne detection of galactic axion dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Lyman alpha and Lyman continuum emission of Mg Ⅱ -selected star-forming galaxies

We present observations with the Cosmic Origins Spectrograph onboard the Hubble Space Telescope of seven compact low-mass star-forming galaxies at redshifts, z, in the range 0.3161–0.4276, with various O 3 Mg 2 = [O iii] λ5007/Mg ii λ2796+2803 and Mg 2 = Mg ii λ2796/Mg ii λ2803 emission-line ratios. We aim to study the dependence of leaking Lyman continuum (LyC) emission on the characteristics of Mg ii emission together with the dependencies on other indirect indicators of escaping ionizing radiation. LyC emission with escape fractions f esc (LyC) = 3.1–4.6 percent is detected in four galaxies, whereas only 1σ upper limits of f esc (LyC) in the remaining three galaxies were derived. A strong narrow Lyα emission line with two peaks separated by V sep ~ 298–592 km s -1 was observed in four galaxies with detected LyC emission and very weak Lyα emission is observed in galaxies with LyC non-detections. Our new data confirm the tight anticorrelation between f esc (LyC) and V sep found for previous low-redshift galaxy samples. V sep remains the best indirect indicator of LyC leakage among all considered indicators. It is found that escaping LyC emission is detected predominantly in galaxies with Mg 2 ≳ 1.3. A tendency of an increase of f esc (LyC) with increasing of both the O 3 Mg 2 and Mg 2 is possibly present. However, there is substantial scatter in these relations not allowing their use for reliable prediction of f esc (LyC).

79 ASTRONOMY AND ASTROPHYSICS↗

Seismic Elastic Double-Beam Characterization of Faults and Fractures for CO₂ Storage Site Selection

Site characterization for underground injection and storage of gigatonne-scale CO₂ requires reliable and cost-effective methods to detect and characterize faults and fractures and to assess their stress state and fault activation potential. This is critical, as wastewater injection and disposal have been shown to activate faults and induce earthquakes, and CO₂ leakage remains a key concern for long-term storage. In this project, we developed seismic methods to detect and characterize large-scale sedimentary and crystalline basement faults and associated small-scale fractures below conventional seismic imaging resolution using multicomponent (9C) surface seismic data. Machine learning was used to automatically interpret large-scale faults, providing key information for estimating the maximum magnitude of potential induced earthquakes. High-fidelity imaging was achieved by exploiting redundancy across multiple elastic wave modes, where independent images from different modes and frequencies cross-validate each other. We also used our nonlinear signal comparison (NLSC) method for ground roll removal, improving data quality in complex near-surface conditions. The methods were validated using field data acquired in central Montana. Results show that basement faults extend into the sedimentary section and that small-scale fractures are widespread above the basement. The inferred stress orientation is consistent with regional stress data, and the estimated maximum induced earthquake magnitude is small (Mw ~2.3). The developed workflow provides a practical approach for fault and fracture characterization and for assessing induced seismicity and leakage risk. It is directly applicable to CO₂ storage site selection and to other subsurface systems.

02 PETROLEUM↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

AGR-5/6/7 Final Release-to-Birth Ratio Data Analysis

AGR-5/6/7 is the last of a series of Advanced Gas Reactor (AGR) experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tristructural isotropic (TRISO) low-enriched fuel for use in the high-temperature gas cooled reactor (HTGR). AGR configuration and irradiation conditions are based on prismatic HTGR technology that is distinguished primarily through the use of helium coolant, a low-power-density ceramic core capable of withstanding very high temperatures, and TRISO-coated particle fuel. The AGR tests provide valuable irradiation-performance data to support fuel process development, qualify fuel for normal operation and accident conditions, and support development and validation of fuel performance and fission-product (FP) transport models and codes. Each AGR test consists of multiple independently controlled and monitored capsules containing fuel compacts placed in a graphite cylinder shrouded by a steel shell. Release-to-birth ratios (R/B) for fission-gas isotopes released from each capsule are calculated from release rates, measured by germanium detectors in the Fission Product Monitoring System (FPMS) installed downstream from each capsule, and birth rates calculated using numerical models of FG generation. The R/Bs are a critical measure of the ability of the fuel kernel, the particle coating layers, and the compact matrix to retain fission-gas atoms, preventing their release into the sweep-gas flow, and the impact of initially defective particles and/or particle-coating failures that occur during irradiation. For fission-gas isotopes, particle failure is defined as failure of all coating layers, allowing gaseous fission atoms to escape from a particle. During the first five cycles (162B ? 165A), R/Bs were stable in the 10-8?10-6 range, and no in-pile particle failures were observed, based on the gross gamma counts. The maximum R/B value of around 2 ? 10-6 for Kr-85m resulted from the presence of as-fabricated exposed kernels (based on the high exposed kernel fraction), the dispersed uranium, and high fuel particle temperatures in Capsule 1. Comparison of capsule-measured R/Bs from these early cycles to predictions using the previously developed AGR R/B model demonstrated FG release from the AGR-5/6/7 TRISO fuel was comparable to that of previous experiments. In addition, the Kr-85m R/B per-exposed-kernel values are comparable to R/B values obtained in AGR-3/4 irradiation experiment and four irradiation experiments performed during 1980s: (1) HRB-17/18, (2) COMEDIE-BD1, (3) HFR B1, and (4) HRB-21. In contrast, all measured R/B values are lower than predictions by the commonly used Richards and German models, which are intentionally conservative. A large number of in-pile particle failures occurred in Capsule 1 by the end of Cycle 166A. During the final four cycles (166A ? 168A), apparent damage to the Capsule 1 gas line appeared to cause FG leakage from that capsule into the other four capsules, resulting in an increase in fission gas (FG) detected in the effluent for all capsules. Isolation of the Capsule 1 gas line during the last three cycles also prevented measurement of its FG release. Thus, R/Bs in all capsules after Cycle 166A are highly uncertain because of undefined amount of leakage from Capsule 1, especially for long-lived isotopes. A few hundred in-pile particle failures were estimated for Capsule 1 before the end of Cycle 166A, but the total number of failures is unknown due to the lack of FG release data in the later cycles. Based primarily on evidence from the gross gamma counts during Cycle 168A, approximately 15 particles failed in Capsule 3 and four particles failed in Capsule 2. In-pile failures in Capsule 3 were anticipated because this capsule was designed to operate beyond the HTGR normal operating temperature range. In contrast, no in-pile failures were identified in the top two capsules (4 and 5) based on the absence of the typical spikes in gross gamma counts and low failure estimates using the AGR model, developed in INL/EXT-14-32970, for R/B of the short-lived isotopes (Kr-89 and Xe-137) with minimal leakage from Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gas transport across the low-permeability containment zone of an underground nuclear explosion

Understanding the nature of gas transport from an underground nuclear explosion (UNE) is required for evaluating the ability to detect and interpret either on-site or atmospheric signatures of noble gas radionuclides resulting from the event. We performed a pressure and chemical tracer monitoring experiment at the site of an underground nuclear test that occurred in a tunnel in Nevada to evaluate the possible modes of gas transport to the surface. The site represents a very well-contained, low gaspermeability end member for past UNEs at the Nevada National Security Site. However, there is very strong evidence that gases detected at the surface during a period of low atmospheric pressure resulted from fractures of extremely small aperture that are essentially invisible. Our analyses also suggest that gases would have easily migrated to the top of the high-permeability collapse zone following the detonation minimizing the final distance required for migration along these narrow fractures to the surface. This indicates that on-site detection of gases emanating from such low-permeability sites is feasible while standoff detection of atmospheric plumes may also be possible at local distances for sufficiently high fracture densities. Finally, our results show that gas leakage into the atmosphere also occurred directly from the tunnel portal and should be monitored in future tunnel gas sampling experiments for the purpose of better understanding relative contributions to detection of radioxenon releases via both fracture network and tunnel transport.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Predictions for the Detectability of Milky Way Satellite Galaxies and Outer-Halo Star Clusters with the Vera C. Rubin Observatory

We predict the sensitivity of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) to faint, resolved Milky Way satellite galaxies and outer-halo star clusters. We characterize the expected sensitivity using simulated LSST data from the LSST Dark Energy Science Collaboration (DESC) Data Challenge 2 (DC2) accessed and analyzed with the Rubin Science Platform as part of the Rubin Early Science Program. We simulate resolved stellar populations of Milky Way satellite galaxies and outer-halo star clusters over a wide range of sizes, luminosities, and heliocentric distances, which are broadly consistent with expectations for the Milky Way satellite system. We inject simulated stars into the DC2 catalog with realistic photometric uncertainties and star/galaxy separation derived from the DC2 data itself. We assess the probability that each simulated system would be detected by LSST using a conventional isochrone matched-filter technique. We find that assuming perfect star/galaxy separation enables the detection of resolved stellar systems with $M_V$ = 0 mag and $r_{1/2}$ = 10 pc with >50% efficiency out to a heliocentric distance of ~250 kpc. Similar detection efficiency is possible with a simple star/galaxy separation criterion based on measured quantities, although the false positive rate is higher due to leakage of background galaxies into the stellar sample. When assuming perfect star/galaxy classification and a model for the galaxy-halo connection fit to current data, we predict that 89 +/- 20 Milky Way satellite galaxies will be detectable with a simple matched-filter algorithm applied to the LSST wide-fast-deep data set. Different assumptions about the performance of star/galaxy classification efficiency can decrease this estimate by ~7%-25%, which emphasizes the importance of high-quality star/galaxy separation for studies of the Milky Way satellite population with LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Effect of Surface Passivation of CZTS Semiconductor Detector on Leakage Current

Cadmium Zinc Telluride Selenide (CdZnTeSe or CZTS)has shown high crystal quality for room-temperature gamma ray and X-ray detection applications compared to Cadmium Zinc Telluride (CdZnTe or CZT) [1,2]. Current applications of CZT include medical imaging, homeland security, and X-ray and gamma ray astronomy [3]. CZST has similar potential applications

Kangethe, Anthony [Morgan State Univ., Baltimore, ↗

Uncooled GeSn MWIR Photodetectors Using Fully Relaxed Thin Triple‐Step Buffer

GeSn photodetectors monolithically grown on Ge virtual substrates demonstrate mid-wave infrared (MWIR) detection at room temperature. The lattice mismatch between GeSn and Ge causes dislocations and compressive strain, creating leakage pathways and unwanted indirect band transitions. Designed thin Ge 0.91 Sn 0.09 triple-step buffer layers of ≈175 nm total thickness reduce dislocations and enable full relaxation, showing 100% lattice relaxation and smooth surface roughness of 0.83 nm with shorter auto-correlation length in surface morphology compared to single-step buffers. Ge 1-x Sn x photodetectors (x = 0.09, 0.12, and 0.15) on triple-step buffers with n-i-p configurations achieve lattice strain relaxations of 99%, 88%, and 80%, respectively. Ge 0.91 Sn 0.09 and Ge 0.88 Sn 0.12 show gradual variation in auto-correlation amplitude, while Ge 0.85 Sn 0.15 shows an increase due to lattice mismatch. Shockley–Read–Hall recombination current dominates at low reverse bias due to mismatch-induced dislocations, while band-to-band tunneling current dominates at higher reverse bias due to narrowing bandgap under strong electric fields. Here, the photodetectors show extended spectral response with increasing Sn composition of i-GeSn active layer sandwiched by barriers. Ge 0.88 Sn 0.12 and Ge 0.85 Sn 0.15 exhibit extended wavelength cut-offs of 3.12 and 3.27 µm at room temperature, demonstrating significant potential for silicon-based MWIR applications.

GeSn↗

In situ TEM observation of calcium silicate hydrate nanostructure at high temperatures

Fire poses a substantial threat to concrete structures because calcium silicate hydrate (C-S-H) is not thermally stable at high temperatures. Herein, in situ TEM at temperatures from 20 to 800 °C was conducted to study the thermal-induced structural changes in C-S-H. We captured C-S-H shrinks at an average rate of 0.02 μm{sup 2}/{sup o}C upon heating with three stages observed, including induction, constant, and rapid periods. Our observation revealed that an 800 nm pore could be healed during pore structure evolution owing to the reconstruction and deformation among C-S-H blocks. The Ca/Si ratio was dropped at higher temperatures because of the leakage of calcium ions from the C-S-H structure to form CaO precipitates. The temperature-driven phase transformation and degradation were also detected using electron diffraction that C-S-H was transformed into metastable calcium silicate minerals above 800 °C. This work provides insights into the nanoscale transformation of C-S-H at high temperatures.

36 MATERIALS SCIENCE↗