Corrosion Fatigue Life Evaluation of 17-4PH in Support of Water Filled Turbine Hubs
High cycle corrosion fatigue (HCCF) life S-N tests were conducted on wrought 17-4PH in various water environments under accelerated testing conditions. For tests conducted in aerated Columbia River water and in aerated ASTM Type IV water, at ~10 6 cycles, the HCCF stress amplitude was ~70% of the value in air. For deaerated water, the value was ~80%. These values are consist with the small amount of literature data on HCCF life of 17-4PH in water environments. The measured fatigue life both in air and water are much better than the ASME trend curve of high cycle fatigue life of moderate and high strength steels. Measured values were also much better than found in a hydropower-relevant study in the literature on cast 17-4PH. The effect of Amersite 61W on HCCF life was evaluated and found to cause very low times to specimen failure compared to all other water environments.