Search NASA⌕ Search

SEARCH · Search NASA

Results for “locality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Localizing resonant magnetic perturbations for edge localized mode control in KSTAR

An external 3D magnetic perturbation typically drives a resonant response at the rational surfaces from the core to the edge of tokamak plasmas, due to strong mode coupling and amplification. In this paper, we present a method to isolate the edge from core resonant fields using the ideal perturbed equilibrium code and to design an edge-localized resonant magnetic perturbation (RMP) for effective edge localized mode (ELM) control. A robust feature of the edge-localized RMP is the curtailed response to the field at the low-field-side (LFS) midplane, as opposed to typical RMPs which strongly resonate with the LFS fields. This emphasizes the importance of off-midplane coils to improve ELM control without provoking a large core response that could lead to devastating instabilities. The conceptual design of new ELM control coils based on the edge-localized RMP in KSTAR shows how this new insight can be utilized to enhance the efficiency of our ELM suppression capabilities. Simple window-pane coils matching the edge-localized resonant mode structure substantially expand in the ELM suppression window beyond the existing coil. Further optimization using the flexible optimized coils using space-curves code leads to additional enhancement in the edge-localized control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metastable solubility and local structure of amorphous calcium carbonate (ACC)

The properties of amorphous calcium carbonate provide the foundation for understanding mineralization of calcified skeletons but inconsistencies between studies suggest the physical picture is incomplete. This study quantifies the metastable solubility and structure of ACC produced under a series of chemical conditions. Using complementary in situ methods that quantify ACC structure (in situ PDF analysis) in parallel with chemical composition (TGA, ICP-OES), we find two short-range structures are produced that also show distinct morphological differences. Conditions with high carbonate ion concentrations stabilize a Ca-rich ACC with short-range order that is independent of Mg content. In contrast, low carbonate solutions favor Mg-rich ACC with mixed Ca- and Mg-short range order. Measurements of solubility product determined from supersaturated and undersaturated conditions find the distinctive structures are related to solution carbonate activity while solubility is primarily determined by the magnesium content of the solid. Bulk solubility is a composite that concurs with established values. The findings demonstrate the type of ACC that forms is tuned by Mg2+ and CO3-2- concentration and suggest ACC structure, not bulk composition, is a reliable indicator of intermediate phase. This chemical framework also provides a basis for interpreting apparent differences between observations of ACC in synthetic and natural systems that reconciles previous structural studies.

Mergelsberg, Sebastian T.↗

Local environment and composition of magnesium gallium layered double hydroxides determined from solid-state {sup 1}H and {sup 71}Ga NMR spectroscopy

Ordering of gallium(III) in a series of magnesium gallium (MgGa) layered double hydroxides (LDHs), [Mg{sub 1−x}Ga{sub x}(OH){sub 2}(NO{sub 3}){sub x}·yH{sub 2}O] was investigated using solid-state {sup 1}H and {sup 71}Ga NMR spectroscopy as well as powder X-ray diffraction. Three different proton environments from Mg{sub 3}-OH, Mg{sub 2}Ga-OH and intergallery water molecules were assigned and quantified using ({sup 1}H,{sup 71}Ga) HETCOR and {sup 1}H MAS NMR. A single {sup 71}Ga site originating from the unique Ga site in the MgGa LDH's was observed in {sup 71}Ga MAS and 3QMAS NMR spectra. Both {sup 1}H MAS NMR spectra recorded at 21.1 T (900 MHz) and elemental analysis show that the synthesized MgGa LDH's had a lower Mg:Ga ratio than that of the starting reactant solution. The origin of this is the formation of soluble [Ga(OH){sub 4}]{sup −} complexes formed during synthesis, and not due to formation of insoluble gallium (oxy)hydroxides. No sign of Ga-O-Ga connectivities or defects were detected for the MgGa LDH's. - Graphical abstract: Two types of hydroxides groups are observed in magnesium gallium layered double hydroxides revealing an ordering of Ga in the cation layer. - Highlights: • Ga is ordered in our magnesium gallium layered double hydroxides. • Ga depletion due to formation of soluble Ga complexes during synthesis. • No sign of Ga rich regions in magnesium gallium LDHs. • Solid state {sup 1}H and {sup 71}Ga give detailed insight into the structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local structure and structural rigidity of the green phosphor β-SiAlON:Eu{sup 2+}

Eu{sup 2+} inserted in β-Si{sub 3−x}Al{sub x}O{sub x}N{sub 4−x} is a material that shows exceptional promise as a green-emitting phosphor. Synchrotron X-ray and neutron scattering, in conjunction with first-principles calculations and Eu L{sub 3} X-ray absorption measurements, yield a consistent picture of the composition, and the favorable position for Eu{sup 2+} substitution in the crystal structure. The Debye temperature Θ{sub D}, which is a proxy for structural rigidity relating to effectiveness as a phosphor, is very high for the starting β-Si{sub 3}N{sub 4} framework and is determined to decrease only slightly for the small amounts of Al{sup 3+} and O{sup 2−} co-substitution that are required for charge balance associated with Eu{sup 2+} insertion.

36 MATERIALS SCIENCE↗

Towards in-situ high precision local material velocity measurements in lattice materials under dynamic compression

The study of dynamic compression of materials requires high precision spatial and temporal resolution to infer the material state at any given time. In ultra-fast imaging experiments such as those performed at the Dynamic Compression Sector at the Advanced Photon Source, the current CCD frame rate is less than the X-ray pulse rate necessitating that 4 CCDs be used to image a single scintillator screen to obtain the same projection of transmitted or diffracted beam at time intervals synchronized with the X-ray beam. The use of multiple-camera setups is often employed for a variety of reasons including enhancing the temporal resolution through interleaving frames or increasing the number of viewpoints, for example. Physical corrections are made to have each CCD approximately viewing the same field of view, however we present corrections that can be made after the data collection to further refine and be able to compare movements and changes in the sample between independent CCDs. These software corrections enable higher precision and higher fidelity comparison of position changes due to sample deformation. Furthermore, we present a method to correct images (or frames) as a demonstration toward high fidelity displacement measurements in these types of ultra-fast multi-camera setup experiments.

36 MATERIALS SCIENCE↗

Quantifying the local influence at a tall tower site in nocturnal conditions

The influence of the local terrestrial environment on nocturnal atmospheric CO 2 measurements at a 329-m television transmitter tower (and a component of a CO 2 monitoring network) was estimated in this paper with a tracer release experiment and a subsequent simulation of the releases. This was done to characterize the vertical transport of emissions from the surface to the uppermost tower level and how it is affected by atmospheric stability. The tracer release experiment was conducted over two nights in May of 2009 near the Department of Energy’s Savannah River Site (SRS) in South Carolina. Tracer was released on two contrasting nights—slightly stable and moderately stable—from several upwind surface locations. Measurements at the 329-m level on both nights indicate that tracer was able to mix vertically within a relatively short (~24 km) distance, implying that nocturnal stable conditions do not necessarily prevent vertical dispersion in the boundary layer and that CO 2 measurements at the tower are at least partly influenced by nearby emissions. A simulation of the tracer release is used to calculate the tower footprint on the two nights to estimate the degree to which the local domain affects the tower readings. The effect of the nocturnal boundary layer on the area sampled by the tower can be seen clearly, as the footprints were affected by changes in stability. Finally, the contribution of local sources to the measurements at the tower was minimal, however, suggesting that nocturnal concentrations at upper levels are contributed mostly by regional sources.

54 ENVIRONMENTAL SCIENCES↗

Local Response and Impact on Survival After Local Ablation of Liver Metastases From Colorectal Carcinoma by Computed Tomography-Guided High-Dose-Rate Brachytherapy

Purpose: To determine local tumor control after CT-guided brachytherapy at various dose levels and the prognostic impact of extensive cytoreduction in colorectal liver metastases. Methods and Materials: Seventy-three patients were treated on a single-center prospective trial that was initially designed to be randomized to three dose levels of 15 Gy, 20 Gy, or 25 Gy per lesion, delivered in a single fraction. However, because there was a high rate of cross-over of subjects from higher to lower dose levels, this study is better understood as a prospective trial with three dose levels. No upper size limit for the metastases was applied. We assessed time to local progression, progression-free survival, and overall survival. Results: According to safety constraints cross-over was performed. The final assignment was n = 98, n = 68, and n = 33 in the 15-Gy, 20-Gy, and 25-Gy groups, respectively. Median diameter of the largest tumor lesion in each patient was 5 cm (range, 1-13.5 cm). Estimated mean local recurrence-free survival for all lesions was 34 months (median not reached). The group assigned to 15 Gy after cross-over displayed 34 local recurrences out of 98 lesions; 20 Gy, 15 out of 68 lesions; 25 Gy, 1 out of 33 lesions. The difference between the 25-Gy and the 20-Gy or 15-Gy group was significant (p < 0.05). Repeated local tumor ablations were the most prominent factor for increased survival and dominated additional systemic antitumor treatments. Conclusions: Local tumor control after CT-guided brachytherapy of colorectal liver metastases demonstrated a strong dose dependency. The role of extensive minimally invasive tumor ablation in metastatic colorectal cancer needs to be further established.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative Radiation Therapy Reduces Local Recurrence Rates in Patients With Microscopically Involved Circumferential Resection Margins After Resection of Locally Advanced Rectal Cancer

Purpose: Intraoperative radiation therapy (IORT) is advocated by some for patients with locally advanced rectal cancer (LARC) who have involved or narrow circumferential resection margins (CRM) after rectal surgery. This study evaluates the potentially beneficial effect of IORT on local control. Methods and Materials: All surgically treated patients with LARC treated in a tertiary referral center between 1996 and 2012 were analyzed retrospectively. The outcome in patients treated with IORT with a clear but narrow CRM (≤2 mm) or a microscopically involved CRM was compared with the outcome in patients who were not treated with IORT. Results: A total of 409 patients underwent resection of LARC, and 95 patients (23%) had a CRM ≤ 2 mm. Four patients were excluded from further analysis because of a macroscopically involved resection margin. In 43 patients with clear but narrow CRMs, there was no difference in the cumulative 5-year local recurrence-free survival of patients treated with (n=21) or without (n=22) IORT (70% vs 79%, P=.63). In 48 patients with a microscopically involved CRM, there was a significant difference in the cumulative 5-year local recurrence-free survival in favor of the patients treated with IORT (n=31) compared with patients treated without IORT (n=17) (84 vs 41%, P=.01). Multivariable analysis confirmed that IORT was independently associated with a decreased local recurrence rate (hazard ratio 0.24, 95% confidence interval 0.07-0.86). There was no significant difference in complication rate of patients treated with or without IORT (65% vs 52%, P=.18) Conclusion: The current study suggests that IORT reduces local recurrence rates in patients with LARC with a microscopically involved CRM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Radiation Therapy Improves Local Control After Surgical Resection in Patients With Localized Adrenocortical Carcinoma

Purpose: Adrenocortical carcinoma (ACC) is a rare malignancy known for high rates of local recurrence, though the benefit of postoperative radiation therapy (RT) has not been established. In this study of grossly resected ACC, we compare local control of patients treated with surgery followed by adjuvant RT to a matched cohort treated with surgery alone. Methods and Materials: We retrospectively identified patients with localized disease who underwent R0 or R1 resection followed by adjuvant RT. Only patients treated with RT at our institution were included. Matching to surgical controls was on the basis of stage, surgical margin status, tumor grade, and adjuvant mitotane. Results: From 1991 to 2011, 360 ACC patients were evaluated for ACC at the University of Michigan (Ann Arbor, MI). Twenty patients with localized disease received postoperative adjuvant RT. These were matched to 20 controls. There were no statistically significant differences between the groups with regard to stage, margins, grade, or mitotane. Median RT dose was 55 Gy (range, 45-60 Gy). Median follow-up was 34 months. Local recurrence occurred in 1 patient treated with RT, compared with 12 patients not treated with RT (P=.0005; hazard ratio [HR] 12.59; 95% confidence interval [CI] 1.62-97.88). However, recurrence-free survival was no different between the groups (P=.17; HR 1.52; 95% CI 0.67-3.45). Overall survival was also not significantly different (P=.13; HR 1.97; 95% CI 0.57-6.77), with 4 deaths in the RT group compared with 9 in the control group. Conclusions: Postoperative RT significantly improved local control compared with the use of surgery alone in this case-matched cohort analysis of grossly resected ACC patients. Although this retrospective series represents the largest study to date on adjuvant RT for ACC, its findings need to be prospectively confirmed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗