Search NASA⌕ Search

SEARCH · Search NASA

Results for “low head”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA Tech Briefs, June 2014

Topics include: Real-Time Minimization of Tracking Error for Aircraft Systems; Detecting an Extreme Minority Class in Hyperspectral Data Using Machine Learning; KSC Spaceport Weather Data Archive; Visualizing Acquisition, Processing, and Network Statistics Through Database Queries; Simulating Data Flow via Multiple Secure Connections; Systems and Services for Near-Real-Time Web Access to NPP Data; CCSDS Telemetry Decoder VHDL Core; Thermal Response of a High-Power Switch to Short Pulses; Solar Panel and System Design to Reduce Heating and Optimize Corridors for Lower-Risk Planetary Aerobraking; Low-Cost, Very Large Diamond-Turned Metal Mirror; Very-High-Load-Capacity Air Bearing Spindle for Large Diamond Turning Machines; Elevated-Temperature, Highly Emissive Coating for Energy Dissipation of Large Surfaces; Catalyst for Treatment and Control of Post-Combustion Emissions; Thermally Activated Crack Healing Mechanism for Metallic Materials; Subsurface Imaging of Nanocomposites; Self-Healing Glass Sealants for Solid Oxide Fuel Cells and Electrolyzer Cells; Micromachined Thermopile Arrays with Novel Thermo - electric Materials; Low-Cost, High-Performance MMOD Shielding; Head-Mounted Display Latency Measurement Rig; Workspace-Safe Operation of a Force- or Impedance-Controlled Robot; Cryogenic Mixing Pump with No Moving Parts; Seal Design Feature for Redundancy Verification; Dexterous Humanoid Robot; Tethered Vehicle Control and Tracking System; Lunar Organic Waste Reformer; Digital Laser Frequency Stabilization via Cavity Locking Employing Low-Frequency Direct Modulation; Deep UV Discharge Lamps in Capillary Quartz Tubes with Light Output Coupled to an Optical Fiber; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems, Version II; Advanced Sensor Technology for Algal Biotechnology; High-Speed Spectral Mapper; "Ascent - Commemorating Shuttle" - A NASA Film and Multimedia Project DVD; High-Pressure, Reduced-Kinetics Mechanism for N-Hexadecane Oxidation; Method of Error Floor Mitigation in Low-Density Parity-Check Codes; X-Ray Flaw Size Parameter for POD Studies; Large Eddy Simulation Composition Equations for Two-Phase Fully Multicomponent Turbulent Flows; Scheduling Targeted and Mapping Observations with State, Resource, and Timing Constraints;

Source record↗

An aerodynamic investigation of two 1.83-meter-diameter fan systems designed to drive a subsonic wind tunnel

An experimental, aerodynamic investigation was made of two 1.83 m diameter fan systems which are being considered for the repowered drive section of the 40- by 80-foot wind tunnel at NASA Ames Research Center. One system was low speed, the other was high speed. The low speed fan was tested at various stagger angles from 32.9 deg to 62.9 deg. At a fan blade stagger angle of 40.8 deg and operating at a tip speed of 1155 m/sec, the low speed fan developed 207.3 m of head. The high speed fan had a design blade stagger angle of 56.2 deg and was tested at this stagger angle only. The high speed fan operating at 191.5 m/sec developed 207.3 m of head. Radial distributions of static pressure coefficients, total pressure coefficients, and angles of swirl are presented. Radial surveys were conducted at four azimuth locations in front of the fan, and repeated downstream of the fan. Data were taken for various flow control devices and for two inlet contraction lengths.

Page, V. R.↗

Simple Magnetometer for Autopilots

Simple, low-cost magnetometer is suitable for heading-reference applications in autopilots and other directional control systems. Sensing element utilizes commercially available transformer core; and supporting electronics consist of one transistor, two readily-available integrated-circuit chips, and associated resistors and capacitors.

Garner, H. D.↗

Influence of gravity on cat vertical vestibulo-ocular reflex

The vertical vestibulo-ocular reflex (VOR) was recorded in cats using electro-oculography during sinusoidal angular pitch. Peak stimulus velocity was 50 deg/s over a frequency range from 0.01 to 4.0 Hz. To test the effect of gravity on the vertical VOR, the animal was pitched while sitting upright or lying on its side. Upright pitch changed the cat's orientation relative to gravity, while on-side pitch did not. The cumulative slow component position of the eye during on-side pitch was less symmetric than during upright pitch. Over the mid-frequency range (0.1 to 1.0 Hz), the average gain of the vertical VOR was 14.5 percent higher during upright pitch than during on-side pitch. At low frequencies (less than 0.05 Hz) changing head position relative to gravity raised the vertical VOR gain and kept the reflex in phase with stimulus velocity. These results indicate that gravity-sensitive mechanisms make the vertical VOR more compensatory.

Tomko, D. L.↗

The Arthromitus stage of Bacillus cereus: intestinal symbionts of animals

In the guts of more than 25 species of arthropods we observed filaments containing refractile inclusions previously discovered and named "Arthromitus" in 1849 by Joseph Leidy [Leidy, J. (1849) Proc. Acad. Nat. Sci. Philadelphia 4, 225-233]. We cultivated these microbes from boiled intestines of 10 different species of surface-cleaned soil insects and isopod crustaceans. Literature review and these observations lead us to conclude that Arthromitus are spore-forming, variably motile, cultivable bacilli. As long rod-shaped bacteria, they lose their flagella, attach by fibers or fuzz to the intestinal epithelium, grow filamentously, and sporulate from their distal ends. When these organisms are incubated in culture, their life history stages are accelerated by light and inhibited by anoxia. Characterization of new Arthromitus isolates from digestive tracts of common sow bugs (Porcellio scaber), roaches (Gromphodorhina portentosa, Blaberus giganteus) and termites (Cryptotermes brevis, Kalotermes flavicollis) identifies these flagellated, spore-forming symbionts as a Bacillus sp. Complete sequencing of the 16S rRNA gene from four isolates (two sow bug, one hissing roach, one death's head roach) confirms these as the low-G+C Gram-positive eubacterium Bacillus cereus. We suggest that B. cereus and its close relatives, easily isolated from soil and grown on nutrient agar, enjoy filamentous growth in moist nutrient-rich intestines of healthy arthropods and similar habitats.

Non-NASA Center↗

Synthetic Vision Enhanced Surface Operations With Head-Worn Display for Commercial Aircraft

Experiments and flight tests have shown that airport surface operations can be enhanced by using synthetic vision and associated technologies, employed on a Head-Up Display (HUD) and head-down display electronic moving maps (EMM). Although HUD applications have shown the greatest potential operational improvements, the research noted that two major limitations during ground operations were its monochrome form and limited, fixed field-of-regard. A potential solution to these limitations may be the application of advanced Head Worn Displays (HWDs) particularly during low-visibility operations wherein surface movement is substantially limited because of the impaired vision of pilots and air traffic controllers. The paper describes the results of ground simulation experiments conducted at the NASA Langley Research Center. The results of the experiments showed that the fully integrated HWD concept provided significantly improved path performance compared to using paper charts alone. When comparing the HWD and HUD concepts, there were no statistically-significant differences in path performance or subjective ratings of situation awareness and workload. Implications and directions for future research are described.

Arthur, Jarvis J., III↗

Experiment Design and Visualization Techniques for an X-59 Low-boom Variability Study

This presentation outlines the design of experiments approach and data visualization techniques for a simulation study of sonic booms from NASA’s X-59 supersonic aircraft. The X-59 will soon be flown over communities across the contiguous USA as it produces a low-loudness sonic boom, or low-boom. Survey data on human perception of low-booms will be collected to support development of potential future commercial supersonic aircraft noise regulatory standards. The macroscopic atmosphere plays a critical role in the loudness of sonic booms. The extensive sonic boom simulation study presented herein was completed to assess climatological, geographical, and seasonal effects on the variability of the X-59’s low-boom loudness and noise exposure region size in order to inform X-59 community test planning. The loudness and extent of the noise exposure region make up the “sonic boom carpet.” Two spatial and temporal resolutions of atmospheric input data to the simulation were investigated. A Fast Flexible Space-Filling Design was used to select the locations across the USA for the two spatial resolutions. Analysis of simulated X-59 low-boom loudness data within a regional subset of the northeast USA was completed using a bootstrap forest to determine the final spatial and temporal resolution of the countrywide simulation study. Atmospheric profiles from NOAA’s Climate Forecast System Version 2 database were used to generate over one million simulated X-59 carpets at the final selected 138 locations across the USA. Effects of aircraft heading, season, geography, and climate zone on low-boom levels and noise exposure region size were analyzed. Models were developed to estimate loudness metrics throughout the USA for X-59 supersonic cruise overflight, and results were visualized on maps to show geographical and seasonal trends. These results inform regulators and mission planners on expected variations in boom levels and carpet extent from atmospheric variations. Understanding potential carpet variability is important when planning community noise surveys using the X-59.

X-59↗

Low-Frequency Otolith Function in Microgravity: A Re-Evaluation of the Otolith Tilt-Translation Reinterpretation (OTTR) Hypothesis

On Earth, the low-frequency afferent signal from the otoliths encodes head tilt with respect to the gravitational vertical, and the higher frequency components reflect both tilt and linear acceleration of the head. In microgravity, static tilt of the head does not influence otolith output, and the relationship between sensory input from the vestibular organs, and the visual, proprioceptive and somatosensory systems, would be disrupted. Several researchers have proposed that in 0-g this conflict may induce a reinterpretation of all otolith signals by the brain to encode only linear translation (otolith tilt-translation reinterpretation or OTTR). Ocular counter-rolling (OCR) is a low-frequency otolith-mediated reflex, which generates compensatory torsional eye movements (rotation about the visual axis) towards the spatial vertical during static roll tilt with a gain of approximately 10%. Transient linear acceleration and off-axis centrifugation at a constant angular velocity can also generate OCR. According to the OTTR hypothesis, OCR should be reduced in microgravity, and immediately upon return from a 0-g environment. Results to date have been inconclusive. OCR was reduced following the 10 day Spacelab-1 mission in response to leftward roll tilts (28-56% in 3 subjects and unchanged in one subject), and sinusoidal linear oscillations at 0.4 and 0.8 Hz. OCR gain declined 70% in four monkeys following a 14 day COSMOS mission. Following a 30 day MIR mission OCR gain decreased in one astronaut, but increased in two others following a 180 day mission. We have studied the affect of microgravity on low-frequency otolith function as part of a larger study of the interaction of vision and the vestibular system. This experiment (E-047) involved off-axis centrifugation of payload crewmembers and flew aboard the recent Neurolab mission (STS 90). Presented below are preliminary results focusing on perception and the OCR response during both centrifugation and static tilt.

Moore, Steven T.↗

Transition of Attention in Terminal Area NextGen Operations Using Synthetic Vision Systems

This experiment investigates the capability of Synthetic Vision Systems (SVS) to provide significant situation awareness in terminal area operations, specifically in low visibility conditions. The use of a Head-Up Display (HUD) and Head-Down Displays (HDD) with SVS is contrasted to baseline standard head down displays in terms of induced workload and pilot behavior in 1400 RVR visibility levels. Variances across performance and pilot behavior were reviewed for acceptability when using HUD or HDD with SVS under reduced minimums to acquire the necessary visual components to continue to land. The data suggest superior performance for HUD implementations. Improved attentional behavior is also suggested for HDD implementations of SVS for low-visibility approach and landing operations.

Ellis, Kyle K. E.↗

A dynamical model for reflex activated head movements in the horizontal plane

We present a controls systems model of horizontal-plane head movements during perturbations of the trunk, which for the first time interfaces a model of the human head with neural feedback controllers representing the vestibulocollic (VCR) and the cervicocollic (CCR) reflexes. This model is homeomorphic such that model structure and parameters are drawn directly from anthropomorphic, biomechanical and physiological studies. Using control theory we analyzed the system model in the time and frequency domains, simulating neck movement responses to input perturbations of the trunk. Without reflex control, the head and neck system produced a second-order underdamped response with a 5.2 dB resonant peak at 2.1 Hz. Adding the CCR component to the system dampened the response by approximately 7%. Adding the VCR component dampened head oscillations by 75%. The VCR also improved low-frequency compensation by increasing the gain and phase lag, creating a phase minimum at 0.1 Hz and a phase peak at 1.1 Hz. Combining all three components (mechanics, VCR and CCR) linearly in the head and neck system reduced the amplitude of the resonant peak to 1.1 dB and increased the resonant frequency to 2.9 Hz. The closed loop results closely fit human data, and explain quantitatively the characteristic phase peak often observed.

NASA Discipline Neuroscience↗

Dynamics of the G-excess illusion

The G-excess illusion is increasingly recognized as a cause of aviation mishaps especially when pilots perform high-speed, steeply banked turns at low altitudes. Centrifuge studies of this illusion have examined the perception of subject orientation and/or target displacement during maintained hypergravity with the subject's head held stationary. The transient illusory perceptions produced by moving the head in hypergravity are difficult to study onboard centrifuges because the high angular velocity ensures the presence of strong Coriolis cross-coupled semicircular canal effects that mask immediate transient otolith-organ effects. The present study reports perceptions following head movements in hypergravity produced by high-speed aircraft maintaining a banked attitude with low angular velocity to minimize cross-coupled effects. Methods: Fourteen subjects flew on the NASA KC-135 and were exposed to resultant gravity forces of 1.3, 1.5, and 1.8 G for 3 minute periods. On command, seated subjects made controlled head movements in roll, pitch, and yaw at 30 second intervals both in the dark and with faint targets at a distance of 5 feet. Results: head movement produced transient perception of target displacement and velocity at levels as low as 1.3 G. Reports of target velocity without appropriate corresponding displacement were common. At 1.8 G when yaw head movements were made from a face down position, 4 subjects reported oscillatory rotational target displacement with fast and slow alternating components suggestive of torsional nystagmus. Head movements evoked symptoms of nausea in most subjects, with 2 subjects and 1 observer vomiting. Conclusions: The transient percepts present conflicting signals, which introduced confusion in target and subject orientation. Repeated head movements in hypergravity generate nausea by mechanisms distinct from cross-coupled Coriolis effects.

Baylor, K. A.↗

Practical design of magnetic heading sensors

Although fluxgate magnetometers have been in use for many years, and a number of theoretical studies of these sensors are available, very little information has been published on the engineering choices relating to the detailed design of magnetometers intended for navigational applications in aircraft and other vehicles. This paper addresses some of the problems encountered in the design of the sensing head, the choice of operating mode, and the design of the supporting electronics for a simple low-cost magnetometer system which will produce a digital readout of the magnetic heading of the vehicle in which it is mounted. A major goal of this study has been to develop a design which minimizes circuit complexity, is easy to fabricate and calibrate, and utilizes a minimum of specialized components. Such a magnetometer system is intended either as a stand-alone indicating instrument or as a source of magnetic heading information for a more sophisticated navigational system.

Garner, H. D.↗

Mechanisms of Orthostatic Tolerance Improvement Following Artificial Gravity Exposure Differ Between Men and Women

We recently determined that a short exposure to artificial gravity (AG) improved the orthostatic tolerance limit (OTL) of cardiovascularly deconditioned subjects. We now seek to determine the mechanisms of that improvement in these hypovolemic men and women. Methods. We determined the orthostatic tolerance limit (OTL) of 9 men and 8 women following a 90 min exposure to AG compared to 90 min of head down bed rest (HDBR). In both cases (21 days apart), subjects were made hypovolemic (low salt diet plus 20 mg intravenous furosemide). Orthostatic tolerance was determined from a combination of head up tilt and increasing lower body negative pressure until presyncope. Mean values and correlations with OTL were determined for heart rate, blood pressure, stroke volume, cardiac output and peripheral resistance (Finometer), cerebral artery blood velocity (DWL), partial pressure of carbon dioxide (Novametrics) and body segmental impedance (UFI THRIM) were measured during supine baseline, during OTL to presyncope and during supine recovery Results. Orthostatic tolerance of these hypovolemic subjects was significantly greater on the day of AG exposure than on the HDBR day. Regression of OTL on these variables identified significant relationships on the HDBR day that were not evident on the AG day: resting TPR correlated positively while resting cerebral flow correlated negatively with OTL. On both days, women's resting stroke volume correlated positively with orthostatic tolerance. Higher group mean values of stroke volume and cerebral artery flow and lower values of blood pressure, peripheral vascular and cerebrovascular resistance both at control and during OTL testing were observed on the AG day. Even though regression of OTL on resting stroke volume was significant only in women, presyncopal stroke volume reached the same level on each day of study for both men and women while the OTL test lasted 30% longer in men and 22% longer in women. Cerebral artery flow appeared to follow stroke volume and absolute values of cerebral flow did not correlate with the development of presyncope. Women responded to AG exposure with elevated cerebral flow at resting control and throughout the OTL test, implying a loss of autoregulation in deconditioned (hypovolemic) women following AG exposure. Conclusions. Before countermeasures to space flight cardiovascular deconditioning are established, gender differences in cardiovascular responses to orthostatic stress, in general, and to orthostatic stress following exposure to artificial gravity, in particular, need to be determined. Since, in both men and women, a single, acute bout of AG exposure improved orthostatic tolerance, the feasibility of short exposures to AG during longer spaceflights or prior to entry into a gravity (Earth or Mars) environment, should be explored. Given the known beneficial effects of AG on other organ systems, the present study indicates that the positive effects of AG on cardiac stroke volume make AG a likely candidate for maintaining cardiovascular conditioning.

Evans, J. M.↗

Topography and tectonics of mid-oceanic ridge axes

Numerical fluid dynamic models of mid-oceanic ridge axes were constructed using distributions of material properties constrained by seismic studies and thermal calculations. The calculations indicate that spreading is passive except for forces caused by density differences due to thermal expansion and partial melt. Except for geometric differences due to temperature distribution, one set of mechanical properties can adequately explain central rifts of slow ridges and central peaks of fast ridges. Viscous head loss in the upwelling material dominates at low spreading rates where material ascends through a narrow conduit. Thermal expansion and partial melting dominate at high spreading rates where a wide low viscosity crustal magma chamber is present. The preferred rheology is 10 to the 20th poise for the upwelling lithosphere; less than 5 x 10 to the 17th for the crustal magma chamber and axial intrusion zone at fast ridges, and a yield stress of 200 bars for the lithosphere. The calculation correctly predicts the existence of central peaks at 'hot-spot' ridges, where seismic evidence indicates a large magma chamber.

Sleep, N. H.↗

The Increase in Frictional Resistance Caused by Various Types of Rivet Heads as Determined by Tests of Planing Surfaces

The increase in the frictional resistance of a surface caused by the presence of rivet heads was determined by towing four planing surfaces of the same dimensions. One surface was smooth and represented a surface without rivet heads or one with perfectly flush countersunk rivets. The other three surfaces were each fitted with the same number of full-size rivet heads but of a different type arranged in the same pattern on each surface. The surfaces were towed at speeds representative of the high water speeds encountered by seaplanes during take-off and the range of Reynolds Number covered by the test was from 4 x 10(exp 6) to 18 x 10(exp 6). The rivet heads investigated were oval countersunk, brazier, and round for rivets having shanks 5/32 inch in diameter. The oval countersunk heads were sunk below the surface by dimpling the plating around them. The results of the tests showed that, for the rivet heads investigated, the increase in the friction coefficient of the surface is directly proportional to the height of the rivet head. The order of merit in regard to low resistance is flush countersunk, oval countersunk (whether sunk below the surface or not), brazier, and round.

Truscott, Starr↗

Moving base simulation of an ASTOVL lift-fan aircraft

Using a generalized simulation model, a moving-base simulation of a lift-fan short takeoff/vertical landing fighter aircraft was conducted on the Vertical Motion Simulator at Ames Research Center. Objectives of the experiment were to (1) assess the effects of lift-fan propulsion system design features on aircraft control during transition and vertical flight including integration of lift fan/lift/cruise engine/aerodynamic controls and lift fan/lift/cruise engine dynamic response, (2) evaluate pilot-vehicle interface with the control system and head-up display including control modes for low-speed operational tasks and control mode/display integration, and (3) conduct operational evaluations of this configuration during takeoff, transition, and landing similar to those carried out previously by the Ames team for the mixed-flow, vectored thrust, and augmentor-ejector concepts. Based on results of the simulation, preliminary assessments of acceptable and borderline lift-fan and lift/cruise engine thrust response characteristics were obtained. Maximum pitch, roll, and yaw control power used during transition, hover, and vertical landing were documented. Control and display mode options were assessed for their compatibility with a range of land-based and shipboard operations from takeoff to cruise through transition back to hover and vertical landing. Flying qualities were established for candidate control modes and displays for instrument approaches and vertical landings aboard an LPH assault ship and DD-963 destroyer. Test pilot and engineer teams from the Naval Air Warfare Center, Boeing, Lockheed, McDonnell Douglas, and the British Defence Research Agency participated in the program.

Chung, William W. Y.↗

Tilt and Translation Motion Perception during Pitch Tilt with Visual Surround Translation

The central nervous system must resolve the ambiguity of inertial motion sensory cues in order to derive an accurate representation of spatial orientation. Previous studies suggest that multisensory integration is critical for discriminating linear accelerations arising from tilt and translation head motion. Visual input is especially important at low frequencies where canal input is declining. The NASA Tilt Translation Device (TTD) was designed to recreate postflight orientation disturbances by exposing subjects to matching tilt self motion with conflicting visual surround translation. Previous studies have demonstrated that brief exposures to pitch tilt with foreaft visual surround translation produced changes in compensatory vertical eye movement responses, postural equilibrium, and motion sickness symptoms. Adaptation appeared greatest with visual scene motion leading (versus lagging) the tilt motion, and the adaptation time constant appeared to be approximately 30 min. The purpose of this study was to compare motion perception when the visual surround translation was inphase versus outofphase with pitch tilt. The inphase stimulus presented visual surround motion one would experience if the linear acceleration was due to foreaft self translation within a stationary surround, while the outofphase stimulus had the visual scene motion leading the tilt by 90 deg as previously used. The tilt stimuli in these conditions were asymmetrical, ranging from an upright orientation to 10 deg pitch back. Another objective of the study was to compare motion perception with the inphase stimulus when the tilts were asymmetrical relative to upright (0 to 10 deg back) versus symmetrical (10 deg forward to 10 deg back). Twelve subjects (6M, 6F, 22-55 yrs) were tested during 3 sessions separated by at least one week. During each of the three sessions (out-of-phase asymmetrical, in-phase asymmetrical, inphase symmetrical), subjects were exposed to visual surround translation synchronized with pitch tilt at 0.1 Hz for a total of 30 min. Tilt and translation motion perception was obtained from verbal reports and a joystick mounted on a linear stage. Horizontal vergence and vertical eye movements were obtained with a binocular video system. Responses were also obtained during darkness before and following 15 min and 30 min of visual surround translation. Each of the three stimulus conditions involving visual surround translation elicited a significantly reduced sense of perceived tilt and strong linear vection (perceived translation) compared to pre-exposure tilt stimuli in darkness. This increase in perceived translation with reduction in tilt perception was also present in darkness following 15 and 30 min exposures, provided the tilt stimuli were not interrupted. Although not significant, there was a trend for the inphase asymmetrical stimulus to elicit a stronger sense of both translation and tilt than the out-of-phase asymmetrical stimulus. Surprisingly, the inphase asymmetrical stimulus also tended to elicit a stronger sense of peak-to-peak translation than the inphase symmetrical stimulus, even though the range of linear acceleration during the symmetrical stimulus was twice that of the asymmetrical stimulus. These results are consistent with the hypothesis that the central nervous system resolves the ambiguity of inertial motion sensory cues by integrating inputs from visual, vestibular, and somatosensory systems.

O'Sullivan, Brita M.↗