Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass gauging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Post-glacial Sediment Load and Subsidence in Coastal Louisiana

Sea level rise in the Gulf of Mexico has occurred at a rate of 1.8-2.2 mm/yr during the 20th century, or nearly the same as observed globally due to combined steric and water mass changes. Tide gauges in coastal Louisiana, however, record a substantially larger rate of rise and while a number of causal mechanisms may be responsible, their specific contribution is poorly understood. Using a realistic viscoelastic Earth model, detailed geologic parameters for south Louisiana and new GPS data, we demonstrate that Holocene sedimentary loading in the Gulf and Mississippi River delta is capable of contributing to 1-8 mm/yr of subsidence over areas of 30-0.75 x 10(exp 3) km(exp 2).

rheology mantle↗

Modal Propellant Gauging: High-resolution and non-invasive gauging of both settled and unsettled liquids in reduced gravity.

The modal response of a liquid-filled tank to external acoustic excitation can be used to infer with high resolutionthe mass of contained liquid, the mass flow rate of liquids into and out of the tank, and changes in tank pressure.Both contained liquid mass and internal ullage pressure affect the modal response of the tank walls through fluidmass-loading of the tank walls and pressure-induced wall stiffening, respectively. Modal Propellant Gauging refersto the technology that exploits these shifts in modal frequencies to infer the mass of propellant in a tank. MPG is anon-invasive gauging technology that has demonstrated gauging resolutions of 1% for settled propellants and 2-3%for unsettled, sloshing propellants. Extensive parabolic flight testing of the MPG system on model tanks has beenconducted to validate the technology in reduced gravity. MPG testing on a qualification tank for the Orion Program'sEuropean Service Module has also been conducted and is reported here. Finite element modeling of the OrionESM "upper" tank is discussed and compared with measurement data. Three computational approaches to massdetermination, Peak Tracking, Point Sensor, and Spectral Density methods, are described here. Use cases are definedand analyzed in the context of the Orion ESM Qualification tank data, and an implementation scheme for continuousmass gauging on the Orion ESM is discussed.Keywords: Propellant Mass Gauging, Modal Analysis, Orion ESM

Propellant Mass Gauging↗

Microphysical Properties of Snow and Their Link to Ze-S Relations During BAECC 2014

This study uses snow events from the Biogenic Aerosols-Effects on Clouds and Climate (BAECC) 2014 campaign to investigate the connection between properties of snow and radar observations. The general hydrodynamic theory is applied to video-disdrometer measurements to retrieve masses of falling ice particles. Errors associated with the observation geometry and the measured particle size distribution (PSD) are addressed by devising a simple correction procedure. The value of the correction factor is determined by comparison of the retrieved precipitation accumulation with weighing-gauge measurements. Derived mass-dimensional relations are represented in the power-law form m = amDbm. It is shown that the retrieved prefactor am and exponent bm react to changes in prevailing microphysical processes. From the derived microphysical properties, event-specific relations between the equivalent reflectivity factor Ze and snowfall precipitation rate S (Ze = 5 azsSbzs ) are determined. For the studied events, the prefactor of the Ze-S relation varied between 53 and 782 and the exponent was in the range of 1.19-1.61. The dependence of the factors azs and bzs on the m(D) relation and PSD are investigated. The exponent of the Ze-S relation mainly depends on the exponent of the m(D) relation, whereas the prefactor azs depends on both the intercept parameterN0 of the PSDand the prefactors of them(D) andy(D) relations. Changes in azs for a given N0 are shown to be linked to changes in liquid water path, which can be considered to be a proxy for degree of riming.

von Lerber, Annakaisa↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

International Space Station (ISS) Environmental Control and Life Support System (ECLSS) Vent Flow Reflection and Detection by Robotic External Leak Locator (RELL)

On-orbit Robotic External Leak Locator (RELL) (i.e., mass spectrometer and ion gauge) measurements on the International Space Station (ISS) are presented to show the detection of recurring Environmental Control and Life Support System (ECLSS) vents at multiple ISS locations and RELL pointing directions. The path of ECLSS effluents to the RELL detectors is not entirely obvious at some locations, but the data indicates that diffuse gas-surface reflection or scattering resulting from plume interaction with vehicle surfaces is responsible. RELL was also able to confirm the ISS ECLSS constituents and distinguish them from the ammonia leak based on the ion mass spectra and known venting times during its operation to locate a leak in the ISS port-side External Active Thermal Control System (EATCS) coolant loop.

Gas/Surface Reflections or Scattering↗

International Space Station (ISS) Environmental Control and Life Support System (ECLSS) Vent Flow Reflection and Detection by Robotic External Leak Locator (RELL)

On-orbit Robotic External Leak Locator (RELL) (i.e., mass spectrometer and ion gauge) measurements on the International Space Station (ISS) are presented to show the detection of recurring Environmental Control and Life Support System (ECLSS) vents at multiple ISS locations and RELL pointing directions. The path of ECLSS effluents to the RELL detectors is not entirely obvious at some locations, but the data indicates that diffuse gas-surface reflection or scattering resulting from plume interaction with vehicle surfaces is responsible. RELL was also able to confirm the ISS ECLSS constituents and distinguish them from the ammonia leak based on the ion mass spectra and known venting times during its operation to locate a leak in the ISS port-side External Active Thermal Control System (EATCS) coolant loop.

Gas/Surface Reflections or Scattering↗

Rocket/Radar Sporadic-E Experiment Conducted during the El Coqui 2 Campaign

In order to investigate the complex electrodynamics and neutral-plasma coupling inherent to sporadic-E layers in the earth's mid-latitude ionosphere, a series of rocket/radar experiments were planned as part of the NASA El Coqui H Campaign from Tortuguero Launch Range, Puerto Rico, in March-April, 1998. The rocket experiments consisted of two pairs of "mother-daughter" payloads with limited apogees so that the payloads "hovered" in the sporadic-E region (95-125 km). Each payload pair included vector DC and AC electric field detectors, a highly accurate flux-gate DC magnetometer, an ion mass spectrometer, an ionization gauge, and spaced-electric field receivers to measure the wavelength and phase velocity of the unstable plasma waves. Separate rockets were included to simultaneously carry aloft TMA trails to measure the neutral wind and its velocity shear, believed responsible for the sporadic-E layer formation. In addition to the rocket experiments, incoherent scatter radar measurements of plasma density and drift velocity were gathered almost every night during the 3 week campaign. Continuous VHF backscatter radar operations were carried out from a site near Salinas, Puerto Rico, where 3-m backscatter echoes were observed associated with sporadic-E and other types of low altitude ionospheric layers. Other radars that operated during the campaign included an HF backscatter system near Ponce, Puerto Rico, and a second VHF backscatter radar set up near Aguadila Puerto Rico. On 24 March 1998, one of the instrumented rockets was launched, attaining an apogee of 129 km. The payloads successfully pierced an intense sporadic-E layer observed by both the Arecibo radar and the in-situ density and ion mass spectrometer probes. In-situ DC electric fields revealed very low (about 1-2 mV/m) ambient fields with small amplitude structures of the same order. No high frequency (short scale) waves were observed, consistent with the VHF backscatter observations at the time of the launch. An overview of the observations will be presented.

Pfaff, R.F.↗

Pre-Flight Assessment of Xenon Propellant Usage and Usage Uncertainty for the Psyche Mission

NASA’s Psyche mission will launch in 2022 and begin a 3.6-year cruise to the metallic asteroid Psyche, the largest metal asteroid in the solar system. All primary propulsion will be done with the flight-proven SPT-140 electric propulsion subsystem. The Psyche mission will feature the first use of Hall thrusters for a NASA mission, and the first use of Hall thrusters beyond cis-lunar space, which has presented some unique challenges. In this paper we describe the Psyche propellant feed system architecture, expected propellant usage for the mission, propellant gauging requirements, and challenges associated with propellant gauging. Data from two recent Maxar electric orbit-raising missions with SPT-140 thrusters are reviewed and used to assess in-flight performance. We develop a pressure-volume-temperature gauging method that incorporates the propellant temperature distributions observed in the flight data, and use this method to provide an improved quantitative understanding of in-flight propellant consumption rates and their uncertainties. The results are in excellent agreement with the results of standard Maxar gauging methods and we determine a propellant usage uncertainty of ± 7.1% 3σ based on flight telemetry. Additionally, we demonstrate that the bookkeeping method of propellant gauging accurately predicts the tank pressure flight data. This work has led to design changes in the Psyche spacecraft avionics that will further improve propellant gauging uncertainties, which is particularly important for later phases of the mission. Finally, we statistically combine the predicted propellant mass uncertainties from the two gauging methods and demonstrate that the system will meet the mission requirements for propellant uncertainty. Together, all of this work provides confidence that the Psyche mission can be successfully completed within the existing propellant budget and propellant tank capacity.

Baldwin, Jeff↗

An Intelligent Strain Gauge with Debond Detection and Temperature Compensation

The harsh rocket propulsion test environment will expose any inadequacies associated with preexisting instrumentation technologies, and the criticality for collecting reliable test data justifies investigating any encountered data anomalies. Novel concepts for improved systems are often conceived during the high scrutiny investigations by individuals with an in-depth knowledge from maintaining critical test operations. The Intelligent Strain Gauge concept was conceived while performing these kinds of activities. However, the novel concepts are often unexplored even if it has the potential for advancing the current state of the art. Maturing these kinds of concepts is often considered to be a tangential development or a research project which are both normally abandoned within the propulsion-oriented environment. It is also difficult to justify these kinds of projects as a facility enhancement because facility developments are only accepted for mature and proven technologies. Fortunately, the CIF program has provided an avenue for bringing the Intelligent Strain Gauge to fruition. Two types of fully functional smart strain gauges capable of performing reliable and sensitive debond detection have been successfully produced. Ordinary gauges are designed to provide test article data and they lack the ability to supply information concerning the gauge itself. A gauge is considered to be a smart gauge when it provides supplementary data relating other relevant attributes for performing diagnostic function or producing enhanced data. The developed strain gauges provide supplementary signals by measuring strain and temperature through embedded Karma and nickel chromium (NiCr) alloy elements. Intelligently interpreting the supplementary data into valuable information can be performed manually, however, integrating this functionality into an automatic system is considered to be an intelligent gauge. This was achieved while maintaining a very low mass. The low mass enables debond detection and temperature compensation to be performed when the gauge is utilized on small test articles. It was also found that the element's mass must be relatively small to avoid overbearing the desired thermal dissipation characteristics. Detecting the degradation of a gauge s bond was reliably achieved by correlating thermal dissipation with the bond s integrity. This was accomplished by precisely coupling a NiCr element with a Karma element for accurately interjecting and quantifying thermal energy. A finite amount of thermal energy is consistently placed in the gauge by electrically powering the NiCr element. The energy will only be temporarily stored before it begins to dissipate into the surrounding structure through the gauge bond. The ability to transmit the energy into the structure becomes greatly inhibited by any discontinuity in the bond s substrate. Therefore, the way the thermal dissipation occurs will reveal even the slightest change in the integrity of the bond.

Jensen, Scott L.↗

Miniature Piezoelectric Macro-Mass Balance

Mass balances usually use a strain gauge that requires an impedance measurement and is susceptible to noise and thermal drift. A piezoelectric balance can be used to measure mass directly by monitoring the voltage developed across the piezoelectric balance, which is linear with weight or it can be used in resonance to produce a frequency change proportional to the mass change (see figure). The piezoelectric actuator/balance is swept in frequency through its fundamental resonance. If a small mass is added to the balance, the resonance frequency shifts down in proportion to the mass. By monitoring the frequency shift, the mass can be determined. This design allows for two independent measurements of mass. Additionally, more than one sample can be verified because this invention allows for each sample to be transported away from the measuring device upon completion of the measurement, if required. A piezoelectric actuator, or many piezoelectric actuators, was placed between the collection plate of the sampling system and the support structure. As the sample mass is added to the plate, the piezoelectrics are stressed, causing them to produce a voltage that is proportional to the mass and acceleration. In addition, a change in mass delta m produces a change in the resonance frequency with delta f proportional to delta m. In a microgravity environment, the spacecraft could be accelerated to produce a force on the piezoelectric actuator that would produce a voltage proportional to the mass and acceleration. Alternatively, the acceleration could be used to force the mass on the plate, and the inertial effects of the mass on the plate would produce a shift in the resonance frequency with the change in frequency related to the mass change. Three prototypes of the mass balance mechanism were developed. These macro-mass balances each consist of a solid base and an APA 60 Cedrat flextensional piezoelectric actuator supporting a measuring plate. A similar structure with 3 APA 120 Cedrat flextensional piezoelectric actuators spaced equidistantly at 120 degrees supporting the plate and a softer macro balance with an APA 150 actuator/sensor were developed. These flextensional actuators were chosen because they increase the sensitivity of the actuator to stress, allow the piezoelectric to be pre-stressed, and the piezoelectric element is a stacked multilayer actuator, which has a considerably lower input impedance than a monolithic element that allows for common instruments (e.g., input impedance of 10 megohms) to measure the voltage without rapidly discharging the charge/voltage on the piezoelectric actuator.

Sherrit, Stewart↗

Global variability of precipitation according to the Tropical Rainfall Measuring Mission

Numerous studies have documented the effect of El Nino-Southern Oscillation (ENSO) on rainfall in many regions of the globe. The question of whether ENSO is the single most important factor in interannual rainfall variability has received less attention, mostly because the kind of data that would be required to make such an assessment were simply not available. Until 1979 the evidence linking El Nino with changes in rainfall around the world came from rain gauges measuring precipitation over land masses and a handful of islands. From 1980 until the launch of the Tropical Rainfall Measuring Mission (TRMM) in November 1997 the remote sensing evidence was confined to ocean rainfall because of the very poor sensitivity of the instruments over land. In this paper we summarize the results of a principal component analysis of TRMM's 60-month (January 1998 to December 2002) global land and ocean remote-sensing record of monthly rainfall accumulations. Contrary to the first principal component of the rainfall itself, the first three indices of the anomaly are most sensitive to precipitation over the ocean rather than over the land. With the help of archived surface station data the first TRMM rain anomaly index is extended back several decades. Comparison of the extended index with the Southern Oscillation Index confirms that the first principal component of the rainfall anomaly is strongly correlated with the ENSO indices.

rainfall↗

Calibrating Laser Gas Measurements by Use of Natural CO2

An improved method of calibration has been devised for instruments that utilize tunable lasers to measure the absorption spectra of atmospheric gases in order to determine the relative abundances of the gases. In this method, CO2 in the atmosphere is used as a natural calibration standard. Unlike in one prior calibration method, it is not necessary to perform calibration measurements in advance of use of the instrument and to risk deterioration of accuracy with time during use. Unlike in another prior calibration method, it is not necessary to include a calibration gas standard (and the attendant additional hardware) in the instrument and to interrupt the acquisition of atmospheric data to perform calibration measurements. In the operation of an instrument of this type, the beam from a tunable diode laser or a tunable quantum-cascade laser is directed along a path through the atmosphere, the laser is made to scan in wavelength over an infrared spectral region that contains one or two absorption spectral lines of a gas of interest, and the transmission (and, thereby, the absorption) of the beam is measured. The concentration of the gas of interest can then be calculated from the observed depth of the absorption line(s), given the temperature, pressure, and path length. CO2 is nearly ideal as a natural calibration gas for the following reasons: CO2 has numerous rotation/vibration infrared spectral lines, many of which are near absorption lines of other gases. The concentration of CO2 relative to the concentrations of the major constituents of the atmosphere is well known and varies slowly and by a small enough amount to be considered constant for calibration in the present context. Hence, absorption-spectral measurements of the concentrations of gases of interest can be normalized to the concentrations of CO2. Because at least one CO2 calibration line is present in every spectral scan of the laser during absorption measurements, the atmospheric CO2 serves continuously as a calibration standard for every measurement point. Figure 1 depicts simulated spectral transmission measurements in a wavenumber range that contains two absorption lines of N2O and one of CO2. The simulations were performed for two different upper-atmospheric pressures for an airborne instrument that has a path length of 80 m. The relative abundance of CO2 in air was assumed to be 360 parts per million by volume (approximately its natural level in terrestrial air). In applying the present method to measurements like these, one could average the signals from the two N2O absorption lines and normalize their magnitudes to that of the CO2 absorption line. Other gases with which this calibration method can be used include H2O, CH4, CO, NO, NO2, HOCl, C2H2, NH3, O3, and HCN. One can also take advantage of this method to eliminate an atmospheric-pressure gauge and thereby reduce the mass of the instrument: The atmospheric pressure can be calculated from the temperature, the known relative abundance of CO2, and the concentration of CO2 as measured by spectral absorption. Natural CO2 levels on Mars provide an ideal calibration standard. Figure 2 shows a second example of the application of this method to Mars atmospheric gas measurements. For sticky gases like H2O, the method is particularly powerful, since water is notoriously difficult to handle at low concentrations in pre-flight calibration procedures.

Webster, Chris↗

The need for an intermediate mass scale in GUTs

The minimal SU(5) grand unified field theory (GUT) model fails to resolve the strong charge parity (CP) problem, suffers from the cosmological monopole problem, sheds no light on the nature of the 'dark' mass in the universe, and predicts an unacceptably low value for the baryon asymmetry. All these problems can be overcome in suitable grand unified axion models with an intermediate mass scale of about 10 to the 11th power to 10 to the 12th power GeV. An example based on the gauge group SO(10) is presented. Among other things, it predicts that the axions comprise the 'dark' mass in the universe, and that there exists a galactic monopole flux of 10 to the -8th power to 10 to the -7th power/sq cm/yr. Other topics that are briefly discussed include proton decay, family symmetry, neutrino masses and the gauge hierarchy problem.

Shafi, Q.↗

Ionization-Assisted Getter Pumping for Ultra-Stable Trapped Ion Frequency Standards

A method eliminates (or recovers from) residual methane buildup in getter-pumped atomic frequency standard systems by applying ionizing assistance. Ultra-high stability trapped ion frequency standards for applications requiring very high reliability, and/or low power and mass (both for ground-based and space-based platforms) benefit from using sealed vacuum systems. These systems require careful material selection and system processing (cleaning and high-temperature bake-out). Even under the most careful preparation, residual hydrogen outgassing from vacuum chamber walls typically limits the base pressure. Non-evaporable getter pumps (NEGs) provide a convenient pumping option for sealed systems because of low mass and volume, and no power once activated. An ion gauge in conjunction with a NEG can be used to provide a low mass, low-power method for avoiding the deleterious effects of methane buildup in high-performance frequency standard vacuum systems.

Tjoelker, Robert L.↗

Vertical density and temperature structure over northern Europe

Vertical profiles of upper-atmosphere temperature and density over northern Europe constructed from data obtained in November and December 1980, as part of the Energy Budget Campaign, are presented and discussed. Temperature sondes, passive spheres, accelerometers, mass and IR spectrometers, and density gauges were rocket launched from ESRANGE, Sweden and Andoya, Norway; the data are combined with ground measurements to construct 20-120-km-altitude profiles for night periods of severe, moderate, and minimal geomagnetic storm activity. The profiles are compared with each other and with the 1976 U.S. Standard Atmosphere (USSA). In the temperature profiles, increased geomagnetic activity is associated with lower temperatures and flattened profiles in the stratopause region, and higher temperatures in the 70-90-km range. The density profiles show a variation of less than about 15 percent, except for a 25-percent range for the moderate-geomagnetic-activity period. The inferred wavelengths and periods are those expected for internal gravity waves at this altitude, and the divergence from USSA is accounted for by season and latitude dependence.

Philbrick, C. R.↗

The International Space Station (ISS) Port 1 (P1) External Active Thermal Control System (EATCS) Ammonia Leak

From 2011 to 2017, the crew onboard the International Space Station (ISS) was at risk of dire consequences due to an external ammonia leak. Ammonia is used in the External Active Thermal Control System (EATCS) to cool the pressurized modules and external electrical systems. Engineers at NASA's Johnson Space Center (JSC) initially detected the leak in one of two cooling loops by monitoring the system ammonia inventory decay over time. White flakes seen on High Definition (HD) cameras were also thought to be associated with the leakage but not confirmed. Initially, the leak was small enough that the ammonia inventory and system operations were not in jeopardy. However, the leak began to accelerate to the point where troubleshooting and corrective action were vital to the sustainability of the ISS. Therefore, it became imperative that the leak be located and repaired for ISS operations to continue. No tools were readily available on the ISS to locate such a leak when it was initially detected, however NASA engineers were already in the process of developing a new device for this purpose called the Robotic External Leak Locator (RELL). The RELL is a robotic instrument package with a mass spectrometer and an ion pressure gauge. Initial checkout operations with RELL happened to coincide with the increasing leak, and ammonia vapors were measured around the P1 EATCS Radiator #3 flexible jumper hoses. The leak stopped after the radiator and its flexible hoses were remotely isolated from the loop and the ammonia from the isolated segment was vented to space. Astronauts conducted a spacewalk that successfully removed the hoses, which were returned to ground for further investigation. The purpose of this paper is to review the leak detection and isolation efforts, investigation results, lessons learned and the recovery plan.

Cowan, Darnell T.↗

The International Space Station (ISS) Port 1 (P1) External Active Thermal Control System (EATCS) Ammonia Leak

From 2011 to 2017, the crew onboard the International Space Station (ISS) was at risk of dire consequences due to an external ammonia leak. Ammonia is used in the External Active Thermal Control System (EATCS) to cool the pressurized modules and external electrical systems. Engineers at NASA's Johnson Space Center (JSC) initially detected the leak in one of two cooling loops by monitoring the system ammonia inventory decay over time. White flakes seen on High Definition (HD) cameras were also thought to be associated with the leakage but not confirmed. Initially, the leak was small enough that the ammonia inventory and system operations were not in jeopardy. However, the leak began to accelerate to the point where troubleshooting and corrective action were vital to the sustainability of the ISS. Therefore, it became imperative that the leak be located and repaired for ISS operations to continue. No tools were readily available on the ISS to locate such a leak when it was initially detected, however NASA engineers were already in the process of developing a new device for this purpose called the Robotic External Leak Locator (RELL). The RELL is a robotic instrument package with a mass spectrometer and an ion pressure gauge. Initial checkout operations with RELL happened to coincide with the increasing leak, and ammonia vapors were measured around the P1 EATCS Radiator #3 flexible jumper hoses. The leak stopped after the radiator and its flexible hoses were remotely isolated from the loop and the ammonia from the isolated segment was vented to space. Astronauts conducted a spacewalk that successfully removed the hoses, which were returned to ground for further investigation. The purpose of this paper is to review the leak detection and isolation efforts, investigation results, lessons learned and the recovery plan.

Cowan, Darnell T.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗