Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

From Fossil Fuels to Green Mines: Understanding Hydrogen-Shale Interactions for Secure Underground Storage

Hydrogen-powered mining trucks are rapidly gaining traction as a key driver of decarbonization in the mining industry. This surge necessitates a decisive shift towards renewable energy sources, primarily for hydrogen production. However, the inherent intermittency of renewables poses a challenge for continuous operations, demanding efficient storage solutions for hydrogen fuel. Hydrogen, derived from renewables, requires large-scale storage, with underground hydrogen storage (UHS) in depleted oil and gas reservoirs projected to provide this capacity. An impermeable seal (caprock) overlying depleted reservoirs is crucial for preventing leakage and ensuring secure storage. Shale, a potential caprock, has been recognized for its effectiveness in containing natural gas for geological time-periods. This study investigates the impact of hydrogen exposure on the matrix permeability of Marcellus shale, a key factor influencing its sealing capacity. A novel time-resolved approach was employed, measuring matrix permeability after each exposure to understand the dynamic interactions between hydrogen and the shale matrix. Samples were exposed to hydrogen in pressure reactions at realistic reservoir conditions at varying time durations. Preliminary results reveal an initial increase in permeability, while subsequent exposures show a decrease, indicating potential microstructural changes.

08 HYDROGEN↗

INFRARED AND ULTRAVIOLET SPECTRA OF METHANE DILUTED IN SOLID NITROGEN AND IRRADIATED WITH ELECTRONS DURING DEPOSITION AT VARIOUS TEMPERATURES

We recorded the infrared and ultraviolet absorption spectra of CH{sub 4}:N{sub 2} matrix samples that underwent electron bombardment during deposition in the temperature range of 10–44 K. In contrast to a previous experiment on the IR spectroscopy of electron-bombarded icy samples, methyl and azide radicals became the main products upon electron bombardment during deposition; furthermore, reduced production of nitrile species was observed for deposition at 10 and 20 K. On the other hand, for deposition above 33 K, the observed bands of the radical species (such as methyl and azide) decreased, and bands of large nitriles appeared. This observation may suggest that radical species easily diffuse and recombine to form more complex molecules in solid nitrogen at higher temperatures. Further measurements of similar samples at 10–33 K in the UV region revealed the intense band of azide radicals at 272.5 nm and weak, broad, overlapping features of methyl and azide radicals in the 225–197 nm region. For deposition at 44 K, only a broad feature centered at 219.4 nm was observed, and the possible carriers of nitrile species were proposed based on the corresponding IR spectrum and theoretical predictions of excitation energy. This band is similar to the observed absorption feature of Pluto’s surface recorded by the Hubble telescope in terms of both band position and bandwidth. Our findings therefore further support the suggestion that complex nitrile species may exist on the surface of Pluto.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Survey of Collection Media for Environmental Sampling

A study was undertaken to survey other potential sampling media that may be more effective in collecting nuclear materials and at the same time contain less uranium. Approximately 40 natural and synthetic fiber wipers were tested. A few were coated with complexants and/or solvents during the manufacturing process. Adhesives and tapes were also included. The relative merits of each sampling matrix were reviewed on the basis of: 1) efficiency in collecting uranium from surfaces, 2) the ease by which the wiper fabric is separated from the nuclear components, 3) latent uranium background of the wiper, 4) the impact that any dissolved swipe components might have on the chromatographic recovery of uranium, and finally, 5) the presence of any isobaric interferences that the dissolved swipe might contribute to the background during MS analysis. Results from this survey are compared to the standard cotton swipe and recommendations presented for the most promising candidates for further consideration.

Fontenot, Hunter↗

Report for Batch Leach Analyses on Sediments at 100-HR-3 Operable Unit, Boreholes C7620, C7621, C7622, C7623, C7626, C7627, C7628, C7629, C7630, and C7866

This is a revision to a previously released report. This revision contains additional analytical results for the sample with HEIS number B2H4X7. Between November 4, 2010 and October 26, 2011 sediment samples were received from 100-HR-3 Operable Unit for geochemical studies. The analyses for this project were performed at the 331 building located in the 300 Area of the Hanford Site. The analyses were performed according to Pacific Northwest National Laboratory (PNNL) approved procedures and/or nationally recognized test procedures. The data sets include the sample identification numbers, analytical results, estimated quantification limits (EQL), and quality control data. The preparatory and analytical quality control requirements, calibration requirements, acceptance criteria, and failure actions are defined in the on-line QA plan 'Conducting Analytical Work in Support of Regulatory Programs' (CAW). This QA plan implements the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD) for PNNL. Samples were received with a chain of custody (COC) and were analyzed according to the sample identification numbers supplied by the client. All Samples were refrigerated upon receipt until prepared for analysis. All samples were received with custody seals intact unless noted in the Case Narrative. Holding time is defined as the time from sample preparation to the time of analyses. The prescribed holding times were met for all analytes unless noted in the Case Narrative. All reported analytical results meet the requirements of the CAW or client specified SOW unless noted in the case narrative. Due to the requirements of the statement of work and sampling events in the field, the 28 day and the 48 hr requirements cannot be met. The statement of work requires samples to be selected at the completion of the borehole. It is not always possible to complete a borehole and have the samples shipped to the laboratory within the hold time requirements. Duplicate RPD for Uranium 238 (38.9%) was above the acceptance limit (35) in 1E05003-DUP1 for ICPMS-Tc-U-WE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Duplicate RPD for Silver 107 (68.2%) was above the acceptance limit (35) in 2C06004-DUP1 for ICPMS-RCRA-AE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Matrix Spike Recovery for Chromium, Hexavalent (48.8%) was outside acceptance limits (75-125) in 1E23001-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported. Matrix Spike Recovery for Chromium, Hexavalent (50.2%) was outside acceptance limits (75-125) in 2B22010-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported.

54 ENVIRONMENTAL SCIENCES↗

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS. Part 2: Results from actinide doping studies

Previously, we presented actinide isotopic and elemental data from fallout melt glass that was measured using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Direct comparison between these measurements and ‘gold standard’ data obtained by multi-collector ICP-MS showed broad overlap, indicating that HR-ICP-MS is a potentially valuable technique for producing actinide elemental and isotopic data on a relatively rapid timescale. To test the usefulness of this technique further, we doped varying amounts of uranium certified reference materials (CRMs) into a rhyolitic rock standard to establish the effects of uranium concentration and isotopic composition on the accuracy of uranium isotopic analyses by HR-ICP-MS. This also enabled us to quantify peak tailing effects from 238 U on the measurement of 239 Pu and 237 Np, which in turn allows us to constrain correction factors based on measured 237 Np/ 238 U and 239 Pu/ 238 U ratios. A second doping study involved the addition of a mixed actinide standard into three samples with different matrix compositions (termed soil, city, and seawater) to assess whether sample chemistry affects the accuracy and precision of these analyses. Results suggest that this is not the case. Systematic offsets were not observed in elemental or isotopic data derived from the three matrix samples. Results indicate that useful actinide isotopic data can be obtained from whole rock solutions by HR-ICP-MS. Our findings also have implications for solid sampling techniques such as laser ablation ICP-MS, which do not require sample dissolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Texture analysis of AGR program matrix materials

We report the fuel form for high-temperature gas-cooled reactors consists of tristructural isotropic (TRISO) particles embedded in a matrix of graphite flake and carbonized resin. The process of overcoating particles prior to compacting yields a circumferential orientation of the graphite flake surrounding the TRISO particles, which is modified to varied extents when overcoated particles are pressed into the final fuel form. As graphite is highly anisotropic, the texture may impact the properties and performance of the fuel. Ellipsometry was used to measure the texture of the matrix for fueled compacts and unfueled “matrix-only” samples. Results indicated local texture related to the spherical particles in compacts associated with overcoating versus a more linear layered structure in “matrix-only” samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vacuum compatible sample positioning device for matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry imaging

The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in {approx}1 x 10{sup -8} mbar vacuum. The range of motion is set to 100 mm x 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption/ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The ''oversampling'' MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Singular value decomposition utilizing parallel algorithms on graphical processors

One of the current challenges in underwater acoustic array signal processing is the detection of quiet targets in the presence of noise. In order to enable robust detection, one of the key processing steps requires data and replica whitening. This, in turn, involves the eigen-decomposition of the sample spectral matrix, Cx = 1/K xKX(k)XH(k) where X(k) denotes a single frequency snapshot with an element for each element of the array. By employing the singular value decomposition (SVD) method, the eigenvectors and eigenvalues can be determined directly from the data without computing the sample covariance matrix, reducing the computational requirements for a given level of accuracy (van Trees, Optimum Array Processing). (Recall that the SVD of a complex matrix A involves determining V, , and U such that A = U VH where U and V are orthonormal and is a positive, real, diagonal matrix containing the singular values of A. U and V are the eigenvectors of AAH and AHA, respectively, while the singular values are the square roots of the eigenvalues of AAH.) Because it is desirable to be able to compute these quantities in real time, an efficient technique for computing the SVD is vital. In addition, emerging multicore processors like graphical processing units (GPUs) are bringing parallel processing capabilities to an ever increasing number of users. Since the computational tasks involved in array signal processing are well suited for parallelization, it is expected that these computations will be implemented using GPUs as soon as users have the necessary computational tools available to them. Thus, it is important to have an SVD algorithm that is suitable for these processors. This work explores the effectiveness of two different parallel SVD implementations on an NVIDIA Tesla C2050 GPU (14 multiprocessors, 32 cores per multiprocessor, 1.15 GHz clock - peed). The first algorithm is based on a two-step algorithm which bidiagonalizes the matrix using Householder transformations, and then diagonalizes the intermediate bidiagonal matrix through implicit QR shifts. This is similar to that implemented for real matrices by Lahabar and Narayanan ("Singular Value Decomposition on GPU using CUDA", IEEE International Parallel Distributed Processing Symposium 2009). The implementation is done in a hybrid manner, with the bidiagonalization stage done using the GPU while the diagonalization stage is done using the CPU, with the GPU used to update the U and V matrices. The second algorithm is based on a one-sided Jacobi scheme utilizing a sequence of pair-wise column orthogonalizations such that A is replaced by AV until the resulting matrix is sufficiently orthogonal (that is, equal to U ). V is obtained from the sequence of orthogonalizations, while can be found from the square root of the diagonal elements of AH A and, once is known, U can be found from column scaling the resulting matrix. These implementations utilize CUDA Fortran and NVIDIA's CUB LAS library. The primary goal of this study is to quantify the comparative performance of these two techniques against themselves and other standard implementations (for example, MATLAB). Considering that there is significant overhead associated with transferring data to the GPU and with synchronization between the GPU and the host CPU, it is also important to understand when it is worthwhile to use the GPU in terms of the matrix size and number of concurrent SVDs to be calculated.

99 GENERAL AND MISCELLANEOUS↗

Automated Radioanalytical System Incorporating Microwave-Assisted Sample Preparation, Chemical Separation, and Online Radiometric Detection for the Monitoring of Total 99Tc in Nuclear Waste Processing Streams

An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction of Tumor Site from Cancer Pathology Reports using Deep Filters

Purpose: Pathology reports are the primary source of information concerning the millions of cancer cases across the United States. Cancer registries manually process the pathology reports to extract the pertinent information including primary tumor site, behavior, histology, laterality, and grade. Processing a large volume of the pathology reports in a timely manner is a continuing challenge for cancer registries. The purpose of this study is to develop an information extraction pipeline to reliably and efficiently extract reportable information. Method: We have developed a novel inverse-regression (IR) based information extraction pipeline. The inverse-regression based supervised filter has been successfully applied to many application domains. However, its application to the information extraction from unstructured text is hindered primarily by the extreme high-dimensionality of n-gram representations of text. In this study, we attempt to overcome the obstacles by a novel bootstrapping strategy. First, we use an information-theoretic mutual information based filter to discard the excessive and redundant n-gram features. This step reduces the size and improves the condition number of the sample covariance matrix, thus reducing the computational cost and improving the numerical stability of the subsequent inverse-regression step. Then we use localized sliced inverse-regression (LSIR) to learn a low-dimensional discriminatory subspace for information inference. In particular, we use the k-nearest neighbors of an unlabeled pathology report in the learned representation to infer the desired information from the labeled data in a supervised manner. Results: The experiments were conducted on a set of de-identified pathology reports with human expert labels as the ground truth. Our pipeline consistently performed better than or comparable to the best performing state-of-the-art methods while reducing the training and inference times substantially. Conclusion: Our results demonstrate the potential of inverse-regression based information extraction pipeline for reliable and efficient information extraction from unstructured text. The information extracted from the pathology reports can be used along with clinical information, medical imaging, and genomic information to instigate discoveries in cancer research.

Dubey, Abhishek↗

Low-rank matrix decomposition and spatio-temporal sparse recovery for STAP radar

We develop space-time adaptive processing (STAP) methods by leveraging the advantages of sparse signal processing techniques in order to detect a slowly-moving target. We observe that the inherent sparse characteristics of a STAP problem can be formulated as the low-rankness of clutter covariance matrix when compared to the total adaptive degrees-of-freedom, and also as the sparse interference spectrum on the spatio-temporal domain. By exploiting these sparse properties, we propose two approaches for estimating the interference covariance matrix. In the first approach, we consider a constrained matrix rank minimization problem (RMP) to decompose the sample covariance matrix into a low-rank positive semidefinite and a diagonal matrix. The solution of RMP is obtained by applying the trace minimization technique and the singular value decomposition with matrix shrinkage operator. Our second approach deals with the atomic norm minimization problem to recover the clutter response-vector that has a sparse support on the spatio-temporal plane. We use convex relaxation based standard sparse-recovery techniques to find the solutions. With extensive numerical examples, we demonstrate the performances of proposed STAP approaches with respect to both the ideal and practical scenarios, involving Doppler-ambiguous clutter ridges, spatial and temporal decorrelation effects. As a result, the low-rank matrix decomposition based solution requires secondary measurements as many as twice the clutter rank to attain a near-ideal STAP performance; whereas the spatio-temporal sparsity based approach needs a considerably small number of secondary data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel rapid oxidizing fusion method to determine Polonium-210 in air filters

A rapid method for the determination of polonium-210 in air filters has been created for use following a radiological event and for routine environmental monitoring. Air filter samples, including cellulose and glass fiber, are fused with a sodium or potassium nitrate/sodium hydroxide flux material. The alkaline matrix minimizes polonium volatility during sample digestion steps, while efficiently dissolving the air filter and inorganic matter implanted on the filter. The addition of nitrate to the flux destroys organic material which can decrease Polonium recovery during precipitation, extraction and source preparation steps. Polonium is concentrated and separated from the sample matrix using an iron hydroxide precipitation and extraction chromatography with DGA Resin. Polonium-210 is subsequently measured by alpha spectrometry following rapid microprecipitation with bismuth phosphate. The new method employs extraction chromatographic purification to remove alpha emitting interferences and sample matrix constituents which can interfere with 210 Po measurements using alpha spectrometry. The novel blend of sodium hydroxide and alkali metal nitrate digests the air filters quickly and effectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

(U)SAXS characterization of porous microstructure of chert: insights into organic matter preservation

This study characterizes the microstructure and mineralogy of 132 (ODP sample), 1000 and 1880 million-year-old chert samples. By using ultra-small-angle X-ray scattering (USAXS), wide-angle X-ray scattering and other techniques, the preservation of organic matter (OM) in these samples is studied. The scarce microstructural data reported on chert contrast with many studies addressing porosity evolution in other sedimentary rocks. The aim of this work is to solve the distribution of OM and silica in chert by characterizing samples before and after combustion to pinpoint the OM distribution inside the porous silica matrix. The samples are predominantly composed of alpha quartz and show increasing crystallite sizes up to 33 ± 5 nm (1σ standard deviation or SD). In older samples, low water abundances (~0.03%) suggest progressive dehydration. (U)SAXS data reveal a porous matrix that evolves over geological time, including, from younger to older samples, (1) a decreasing pore volume down to 1%, (2) greater pore sizes hosting OM, (3) decreasing specific surface area values from younger (9.3 ± 0.1 m 2 g -1 ) to older samples (0.63 ± 0.07 m 2 g -1 , 1σ SD) and (4) a lower background intensity correlated to decreasing hydrogen abundances. The pore-volume distributions (PVDs) show that pores ranging from 4 to 100 nm accumulate the greater volume fraction of OM. Raman data show aromatic organic clusters up to 20 nm in older samples. Raman and PVD data suggest that OM is located mostly in mesopores. Observed structural changes, silica–OM interactions and the hydro­phobicity of the OM could explain the OM preservation in chert.

(U)SAXS↗

Large-Area Graphene Films as Target Surfaces for Highly Reproducible Matrix-Assisted Laser Desorption Ionization Suitable for Quantitative Mass Spectrometry

Due to the known sweet-spot issues that intrinsically arise from inhomogeneous formation of matrix-analyte crystals utilized as samples in matrix-assisted laser desorption ionization (MALDI) mass spectrometry, its reproducibility and thus its applications for quantification have been somewhat limited. In this paper, we report a simple strategy to improve the uniformity of matrix-analyte crystal spots, which we realized by adapting large-area graphene films, i.e., non-inert, interacting surfaces, as target surfaces. In this example, the graphitic surfaces of the graphene films interact with excess matrix molecules during the sample drying process, which induces spontaneous formation of optically uniform MALDI sample crystal layers on the film surfaces. Further, mass spectrometric imaging reveals that the visible uniformity is indeed accompanied by reproducible MALDI ionization over an entire sample spot, which greatly suppresses the appearance of sweet spots. The results of this study confirm that the proposed method achieves good linear responses of ion intensity to the analyte concentration (R{sup 2} > 0.99) with small relative standard deviations (σ < 10%), which is a range applicable for quantitative measurements using MALDI mass spectrometry. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Setup for optimized grazing incidence x-ray absorption experiments on thin films on substrates

We present a state-of-the-art experimental apparatus and a proper setup to perform x-ray absorption spectroscopy (XAS) experiments in grazing incidence mode. This geometry is appropriate for doped thin films or interfaces buried at moderate depth in a thick matrix, whenever the scattering and/or fluorescence from the matrix has to be strongly attenuated. Both the calculation and the experimental data demonstrate that the specific setup that consists in a grazing incidence and grazing collection geometry is extremely advantageous. In fact, with respect to the standard geometry used to perform XAS experiments in fluorescence mode, the present setup allows an enhancement in the interesting fluorescence signal from the surface layer without a corresponding increase in the elastic scattering contribution from the matrix. The sample holder especially designed for this kind of experiment can work in vacuum and at low temperature. An easy and quick automatic sample alignment procedure is detailed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗