Search NASA⌕ Search

SEARCH · Search NASA

Results for “measured data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measuring the Hubble constant and spatial curvature from supernova apparent magnitude, baryon acoustic oscillation, and Hubble parameter data

Cosmic microwave background (CMB) anisotropy (spatial inhomogeneity) data provide the tightest constraints on the Hubble constant, matter density, spatial curvature, and dark energy dynamics. Other data, sensitive to the evolution of only the spatially homogeneous part of the cosmological model, such as Type Ia supernova apparent magnitude, baryon acoustic oscillation distance, and Hubble parameter measurements, can be used in conjunction with the CMB data to more tightly constrain parameters. Recent joint analyses of CMB and such non-CMB data indicate that slightly closed spatial hypersurfaces are favored in nonflat untilted inflation models and that dark energy dynamics cannot be ruled out, and favor a smaller Hubble constant. Here, we show that the constraints that follow from these non-CMB data alone are consistent with those that follow from the CMB data alone and so also consistent with, but weaker than, those that follow from the joint analyses of the CMB and non-CMB data.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of aerodynamic data measured in air and Freon-12 wind-tunnel test mediums

An experimental investigation was carried out to measure two dimensional static aerodynamic characteristics of a 65 sub l-213 airfoil in air and Freon-12 (dichlorodifluoromethane) test mediums at corresponding test conditions. The purpose of the tests was to compare measurements in the two test mediums and to evaluate reported methods of converting Freon-12 data to equivalent air values. The test article was a two dimensional wing instrumented to measure chordwise surface pressure distributions. The parameters considered were Mach numbers from 0.6 to 1.0, angles of attack of zero deg and 1 deg, and Reynolds numbers based on model chord from 2,000,000 to 21,000,000. The agreement between data measured in the two test mediums is further improved by application of the transonic or area ratio similarity laws. Where flow conditions are characterized by surface shocks or stall, the effects of flow separation may not be identically reflected in the Freon-12 data, even when converted in accordance with existing similarity laws.

Weller, W. H.↗

Constraining the sources of ultra-high-energy cosmic rays across and above the ankle with the spectrum and composition data measured at the Pierre Auger Observatory

In this work we present the interpretation of the energy spectrum and mass composition data as measured by the Pierre Auger Collaboration above 6 × 10$^{17}$ eV. We use an astrophysical model with two extragalactic source populations to model the hardening of the cosmic-ray flux at around 5 × 10$^{18}$ eV (the so-called “ankle” feature) as a transition between these two components. We find our data to be well reproduced if sources above the ankle emit a mixed composition with a hard spectrum and a low rigidity cutoff. The component below the ankle is required to have a very soft spectrum and a mix of protons and intermediate-mass nuclei. The origin of this intermediate-mass component is not well constrained and it could originate from either Galactic or extragalactic sources.To the aim of evaluating our capability to constrain astrophysical models, we discuss the impact on the fit results of the main experimental systematic uncertainties and of the assumptions about quantities affecting the air shower development as well as the propagation and redshift distribution of injected ultra-high-energy cosmic rays (UHECRs).

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of complex glazing products; from optical data measurements to model based predictive controls

Complex glazing systems such as venetian blinds, fritted glass and woven shades require more detailed optical and thermal input data for their components than specular non light-redirecting glazing systems. Various methods for measuring these data sets are described in this paper. These data sets are used in multiple simulation tools to model the thermal and optical properties of complex glazing systems. The output from these tools can be used to generate simplified rating values or as an input to other simulation tools such as whole building annual energy programs, or lighting analysis tools. I also describe some of the challenges of creating a rating system for these products and which factors affect this rating. A potential future direction of simulation and building operations is model based predictive controls, where detailed computer models are run in real-time, receiving data for an actual building and providing control input to building elements such as shades.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determination of instrumentation errors from measured data using maximum likelihood method

The maximum likelihood method is used for estimation of unknown initial conditions, constant bias and scale factor errors in measured flight data. The model for the system to be identified consists of the airplane six-degree-of-freedom kinematic equations, and the output equations specifying the measured variables. The estimation problem is formulated in a general way and then, for practical use, simplified by ignoring the effect of process noise. The algorithm developed is first applied to computer generated data having different levels of process noise for the demonstration of the robustness of the method. Then the real flight data are analyzed and the results compared with those obtained by the extended Kalman filter algorithm.

Keskar, D. A.↗

Measurement of the top quark mass with the template method in the $t\bar{t} \to\mathrm{lepton}+\mathrm{jets}$ channel using ATLAS data

The top quark mass has been measured using the template method in the $t\bar{t} →lepton + jets channel based on data recorded in 2011 with the ATLAS detector at the LHC. The data were taken at a proton-proton centre-of-mass energy of √s = 7 TeV and correspond to an integrated luminosity of 1.04 fb -1 . The analyses in the e + jets and μ + jets decay channels yield consistent results. Here the top quark mass is measured to be m top = 174.5±0.6 stat ±2.3 syst GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimation of terrain iso-gradients from a stochastic range data measurement matrix

The problem of estimating terrain iso-gradients for an autonomous roving vehicle is complicated by the measurement error inherent in the range data matrix. In this paper, the in-path and cross-path slopes at each data point in the multivariable range matrix are expressed in terms of parameters at that data point and those at its surrounding points. The sensitivity in the change of these slopes - due to the errors in measurements in range, elevation angle and azimuth angle are formulated. These sensitivities are used to determine the appropriate statistics of the gradient, which are then used to describe the terrain with a known probability of accuracy.

Shen, C. N.↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

Analysis of pion production data measured by HADES in proton-proton collisions at 1.25 GeV

Baryon resonance production in proton-proton collisions at a kinetic beam energy of 1.25 GeV is investigated. The multi-differential data were measured by the HADES Collaboration. Exclusive channels with one pion in the final state ($np\pi^+$ and $pp\pi^0$ were put to extended studies based on various observables in the framework of a one-pion exchange model and with solutions obtained within the framework of a partial wave analysis (PWA) of the Bonn-Gatchina group. The results of the PWA confirm the dominant contribution of the $\Delta(1232)$, yet with a sizable impact of the $N(1440)$ and non-resonant partial waves.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the inclusive isolated-photon cross section in pp collisions at $\sqrt{s}$ = 13 TeV using 36 fb -1 of ATLAS data

The differential cross section for isolated-photon production in pp collisions is measured at a centre-of-mass energy of 13 TeV with the ATLAS detector at the LHC using an integrated luminosity of 36.1 fb -1 . The differential cross section is presented as a function of the photon transverse energy in different regions of photon pseudorapidity. The differential cross section as a function of the absolute value of the photon pseudorapidity is also presented in different regions of photon transverse energy. Next-to-leading-order QCD calculations from Jetphox and Sherpa as well as next-to-next-to-leading-order QCD calculations from Nnlojet are compared with the measurement, using several parameterisations of the proton parton distribution functions. The predictions provide a good description of the data within the experimental and theoretical uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of Photovoltaic Modeling Tool HelioScope Against Measured Data

HelioScope is a cloud-based solar design software developed by Folsom Labs to model arrays based on physical design. Folsom Labs received a grant from the Department of Energy for the National Renewable Energy Laboratory to validate the performance of HelioScope's simulation engine against measured PV system performance. This study builds upon previous validation work by NREL of multiple other PV modeling tools, using the same fixed-tilt systems with available system specifications. HelioScope designs were set up using the same system specifications and concurrent weather data as were used in previous studies. The predicted performance results from the simulations were compared with measured data and to performance predictions by other PV modeling tools.

14 SOLAR ENERGY↗

Obtaining consistent models of helicopter flight-data measurement errors using kinematic-compatibility and state-reconstruction methods

A new method was developed for application of Kalman Filter/Smoothers to post-flight processing of helicopter flight test dynamic measurements. This processing includes checking for kinematic compatibility among the measurements, identification of a measurement error model, and reconstruction of both measured and unmeasured time histories. Emphasis is placed on identification of a parametric measurement error model which is valid for a set of flight test data. This is facilitated through a new method of concatenating several maneuver time histories. The method also includes a model structure determination step which ensures that a physically realistic parameterization has been achieved. Application of the method to a set of BO-105 flight test data is illustrated. The resulting minimally parameterized error model is shown to characterize the measurement errors of the entire data set with very little variation in the parameter values. Reconstructed time histories are shown to have increased bandwidths and signal to noise ratios.

Fletcher, Jay W.↗

Whole Building Cost and Performance Measurement: Data Collection Protocol Revision 2

This protocol was written for the Department of Energy’s Federal Energy Management Program (FEMP) to be used by the public as a tool for assessing building cost and performance measurement. The primary audiences are sustainable design professionals, asset owners, building managers, and research professionals within the Federal sector. The protocol was developed based on the need for measured performance and cost data on sustainable design projects. Historically there has not been a significant driver in the public or private sector to quantify whole building performance in comparable terms. The deployment of sustainable design into the building sector has initiated many questions on the performance and operational cost of these buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of Nuclear Data Measurement and Analysis at RPI [Slides]

This presentation discusses the experimental, simulation, and nuclear data methods that were validated for the RPI γ-Multiplicity Detector. When the neutron capture γ-cascade data is well-known, the γ-emission spectra can be accurately calculated using the modified simulation tools. The RPI γ-Multiplicity Detector system is now ready for analysis and recommendations for isotopes with deficiencies in γ-ray data. The presentation also discusses future work which includes developing a method for analyzing and adjusting nuclear data for 59 Co, 55 Mn and other measured isotopes including 181 Ta. Additionally, future work includes comparing experimental γ-emission spectra with MCNP-6.2/DICEBOX simulations for 238 U and 235 U. In summation, new capture and transmission measurements for 54 Fe will help improve resonance parameter evaluation. Neutron capture gamma cascade spectra and yields were measured in the resolved resonance region and compared to evaluations. In addition, the pulsed neutron die-away method was developed as a tool to provide data for validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Full Core Multi-Physics PWR Benchmark with Measured Data

In recent years, the importance of modeling and simulation has been highlighted extensively in the DOE research portfolio with concrete examples in nuclear engineering with the CASL and NEAMS programs. These research efforts and similar efforts worldwide aim at the development of high-fidelity multi-physics analysis tools for the simulation of current and next-generation nuclear power reactors. Like all analysis tools, verification and validation is essential to guarantee proper functioning of the software and methods employed. The current approach relies mainly on the validation of single physic phenomena (e.g. critical experiment, flow loops, etc.) and there is a lack of relevant multiphysics benchmark measurements that are necessary to validate high-fidelity methods being developed today. This work introduces a new multi-cycle full-core Pressurized Water Reactor (PWR) depletion benchmark based on two operational cycles of a commercial nuclear power plant that provides a detailed description of fuel assemblies, burnable absorbers, in-core fission detectors, core loading and re-loading patterns. This benchmark enables analysts to develop extremely detailed reactor core models that can be used for testing and validation of coupled neutron transport, thermal-hydraulics, and fuel isotopic depletion. The benchmark also provides measured reactor data for Hot Zero Power (HZP) physics tests, boron letdown curves, and three-dimensional in-core flux maps from 58 instrumented assemblies. The benchmark description is now available online and has been used by many groups. However, much work remains to be done on the quantification of uncertainties and modeling sensitivities. This work aims to address these deficiencies and make this benchmark a true non-proprietary international benchmark for the validation of high-fidelity tools. This report details the BEAVRS uncertainty quantification for the first two cycle of operations and serves as the final report of the project.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Troubleshoot Quartz Crystal Microbalance Measurements Data

We are using a Qpod quartz crystal microbalance (manufactured by Inficon) for use as a low-volume non-volatile residue analysis tool. Inficon has agreed to help troubleshoot some of our measurements and are requesting to view some sample data, which are attached. The basic principle of an NVR analysis is to evaporate a known volume of solvent, and weigh the remaining residue to determine the purity of the solvent. A typical NVR analysis uses 60 g of solvent and can measure residue with an accuracy of +/- 0.01 mg. The detection limit is thus (0.01 mg)/(60 g) = 0.17 ppm. We are attempting to use a quartz crystal microbalance (QCM) to make a similar measurement. The attached data show the response of the QCM as a 5-20 mg drop of solvent evaporates on its surface. The change in mass registered by the QCM after the drop evaporates is the residue that deposits on the crystal. On some measurements, the change in mass in less than zero, which is aphysical since the drop will leave behind ≥0 mass of residue. The vendor, Inficon, has agreed to look at these data as a means to help troubleshoot the cause.

42 ENGINEERING↗

Strategic Petroleum Reserve equation of state model development : current performance against measured data.

This report documents the progression of crude oil phase behavior modeling within the U.S. Strategic Petroleum Reserve vapor pressure program during the period 2004-2009. Improvements in quality control on phase behavior measurements in 2006 coupled with a growing body of degasification plant operations data have created a solid measurement baseline that has served to inform and significantly improve project understanding on phase behavior of SPR oils. Systematic tuning of the model based on proven practices from the technical literature have shown to reduce model bias and match observed data very well, though this model tuning effort is currently in process at SPR and based on preliminary data. The current report addresses many of the steps that have helped to build a strong baseline of data coupled with sufficient understanding of model features so that calibration is possible.

02 PETROLEUM↗