Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of an optical three-dimensional laser tracker using dual modulated laser diodes and a signal detector

Laser trackers are widely used in industry for tasks such as the assembly of airplanes and automobiles, contour measurement, and robot calibration. However, laser trackers are expensive, and the corresponding solution procedure is very complex. The influence of measurement uncertainties is also significant. This study proposes a three-dimensional space position measurement system which consists of two tracking modules, a zero tracking angle return subsystem, and a target quadrant photodiode (QPD). The target QPD is placed on the object being tracked. The origin locking method is used to keep the rays on the origin of the target QPD. The position of the target QPD is determined using triangulation since the two laser rays are projected onto one QPD. Modulation and demodulation are utilized to separate the coupled positional values. The experiment results show that measurement errors in the X, Y, and Z directions are less than {+-}0.05% when the measured object was moved by 300, 300, and 200 mm in the X, Y, and Z axes, respectively. The theoretical measurement error estimated from the measurement model is between {+-}0.02% and {+-}0.07% within the defined measurable range. The proposed system can be applied to the measurements of machine tools and robot arms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Evaluation of Redd Counts as a Measure of Bull Trout Population Size and Trend

Abstract The use of redd counts to monitor abundance and trend of bull trout Salvelinus confluentus has been clouded by uncertainties concerning measurement error, life history variation, and correspondence of redd counts to adult population size. We compared census redd counts with population estimates of mature females for a migratory fluvial population of bull trout (primarily ≥ 300 mm fork length) and for a population of small (<200 mm), likely resident, bull trout. We also compared the measurement error of the experienced surveyors who conducted the redd counts to that of a group of inexperienced surveyors. Although the regression of redd counts on adult females for the migratory population was statistically significant, a large proportion of the variation in the relationship was unexplained (r 2 = 0.47). Despite that variation, redd counts accurately reflected a greater than 50% decline in the population over 10 years; however, 5-year trends in redd counts could be misleading. Power analysis parameterized by using the variation in the number of females per redd and measurement error of experienced surveyors indicated that minimum declines of 44–56% or increases of 78–118% over 10–15 years would be necessary for detection using traditional statistical criteria. Geometric mean abundance of migratory adults derived from redd counts and adults-per-redd values from the present study and published averages were similar to measured adult numbers in most cases. For both migratory and resident populations, redd counts by experienced surveyors were substantially more accurate and precise than those by inexperienced surveyors. Counts of migratory bull trout redds were more accurate and precise than counts of resident bull trout redds, which were significantly smaller and consistently underestimated. Thus, bull trout redd counts can be used to estimate abundance levels and to detect substantial longer-term changes in abundance, particularly for migratory populations. However, the reliability of the counts depends on the skill of the surveyors. Received April 4, 2011; accepted August 8, 2011

Howell, Philip J.↗

Use of Uncertainty in Modeling DFLAW Treatment at Hanford - 17115

Average or mean is understood by most; standard deviation (SD) is understood by few. Certainty is easy to model; uncertainty is not. The flowsheet simulation, described in this paper, placed uncertainties in the G2 model of the Hanford Tank Waste Treatment and Immobilization Plant's (WTP) Direct Feed Low-Activity Waste (DFLAW) process for performance and sensitivity evaluations. G2 is a dynamic material balance model that starts and proceeds with operating logic until all the feed is processed. Dynamic material balance is achieved by tracking the flows, storage, and change of all materials within the plant as time increments. Processing equipment and limitations of the flowsheet are modeled (e.g., equipment types, piping, volumes, flowrates, efficiencies, and physical and chemical environments that impact separations, phase equilibriums, and chemical reactions). Operating logic represents the rules and strategies of a running plant. The G2 model simulated both certainty and uncertainty scenarios for comparison purposes. For the uncertainty scenarios, process decisions were made using presumed values to simulate various operational measurement errors and process variabilities. Presumed means that the known G2 values are adjusted to replicate measurement errors and variabilities. These include: 1) volume measurement, 2) sample analysis, 3) melter decontamination factor (DF), 4) glass former weighing, and 5) glass former composition variations. The errors were randomly generated in accordance with SD values of measurement devices, laboratory methods, and glass former composition ranges. The G2 model runs give insight on the DFLAW process' controllability and the expected range of glass properties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Vegetation and Seasonal Forcing on Carbon Dioxide Fluxes Across the Upper Midwest, USA: Implications for Regional Scaling

Carbon dioxide fluxes were examined over the growing seasons of 2002 and 2003 from 14 different sites in the Upper Midwest (USA) to assess spatial variability of ecosystem–atmosphere CO2 exchange. These sites were exposed to similar temperature/precipitation regimes and spanned a range of vegetation types typical of the region (northern hardwood, mixed forest, red pine, jack pine, pine barrens, and shrub wetland). The hardwood and red pine sites also spanned a range of stand ages (young, intermediate, mature). While seasonal changes in net ecosystem exchange (NEE) and photosynthetic parameters were coherent across the 2 years at most sites, changes in ecosystem respiration (ER) and gross ecosystem production (GEP) were not. Canopy height and vegetation type were important variables for explaining spatial variability of CO2 fluxes across the region. Light-use efficiency (LUE) was not as strongly correlated to GEP as maximum assimilation capacity (Amax). A bottom-up multi-tower land cover aggregated scaling of CO2 flux to a 2000 km2 regional flux estimate found June to August 2003 NEE, ER, and GEP to be -290 ± 89, 408 ± 48, and 698 ± 73 gC m -2 , respectively. Aggregated NEE, ER, and GEP were 280% larger, 32% smaller and 3% larger, respectively, than that observed from a regionally integrating 447 m tall flux tower. However, when the tall tower fluxes were decomposed using a footprint-weighted influence function and then re-aggregated to a regional estimate, the resulting NEE, ER, and GEP were within 11% of the multi-tower aggregation. Excluding wetland and young stand age sites from the aggregation worsened the comparison to observed fluxes. These results provide insight on the range of spatial sampling, replication, measurement error, and land cover accuracy needed for multi-tiered bottom-up scaling of CO2 fluxes in heterogeneous regions such as the Upper Midwest, USA.

54 ENVIRONMENTAL SCIENCES↗

Measuring a Low Horizontal Hydraulic Gradient in a High Transmissivity Aquifer

Abstract High transmissivity aquifers typically have low hydraulic gradients (i.e., a flat water table). Measuring low gradients using water levels can be problematic because measurement error may be greater than the true difference in water levels (i.e., a low signal‐to‐noise ratio). In this study, the feasibility of measuring a hydraulic gradient in the range of 10 −6 to 10 −5 m/m was demonstrated. The study was performed at a site where the depth to water from land surface ranged from 40.1 to 94.2 m and the aquifer transmissivity was estimated at 41,300 m 2 /d (hydraulic conductivity of 18,800 m/d). The goals of the study were to reduce measurement error as much as practicable and assess the importance of factors affecting water level measurement accuracy. Well verticality was the largest source of error (0.000 to 0.168 m; median of 0.014 m), and geodetic survey of casing elevations was the next most important source of error (0.002 to 0.013 m; median of 0.005 m). Variability due to barometric pressure fluctuations was not an important factor at the site. Hydraulic heads were measured to an accuracy of ±0.0065 m, and the average hydraulic gradient was estimated to be 8.0 × 10 −6 (±0.9 × 10 −6 ) m/m. The improvement in accuracy allowed for two reversals in the groundwater flow direction to be identified, after which the gradient averaged 2.5 × 10 −5 (±0.4 × 10 −5 ) m/m. This study showed it is possible to sufficiently control sources of error to measure hydraulic gradients in the 10 −6 to 10 −5 m/m range.

McDonald, John P.↗

Behavior and mechanisms of Doppler wind lidar error in varying stability regimes

Abstract. Wind lidars are widespread and important tools in atmospheric observations. An intrinsic part of lidar measurement error is due to atmospheric variability in the remote-sensing scan volume. This study describes and quantifies the distribution of measurement error due to turbulence in varying atmospheric stability. While the lidar error model is general, we demonstrate the approach using large ensembles of virtual WindCube V2 lidar performing a profiling Doppler-beam-swinging scan in quasi-stationary large-eddy simulations (LESs) of convective and stable boundary layers. Error trends vary with the stability regime, time averaging of results, and observation height. A systematic analysis of the observation error explains dominant mechanisms and supports the findings of the empirical results. Treating the error under a random variable framework allows for informed predictions about the effect of different configurations or conditions on lidar performance. Convective conditions are most prone to large errors (up to 1.5 m s−1 in 1 Hz wind speed in strong convection), driven by the large vertical velocity variances in convective conditions and the high elevation angle of the scanning beams (62∘). Range-gate weighting induces a negative bias into the horizontal wind speeds near the surface shear layer (−0.2 m s−1 in the stable test case). Errors in the horizontal wind speed and direction computed from the wind components are sensitive to the background wind speed but have negligible dependence on the relative orientation of the instrument. Especially during low winds and in the presence of large errors in the horizontal velocity estimates, the reported wind speed is subject to a systematic positive bias (up to 0.4 m s−1 in 1 Hz measurements in strong convection). Vector time-averaged measurements can improve the behavior of the error distributions (reducing the 10 min wind speed error standard deviation to <0.3 m s−1 and the bias to <0.1 m s−1 in strong convection) with a predictable effectiveness related to the number of decorrelated samples in the time window. Hybrid schemes weighting the 10 min scalar- and vector-averaged lidar measurements are shown to be effective at reducing the wind speed biases compared to cup measurements in most of the simulated conditions, with time averages longer than 10 min recommended for best use in some unstable conditions. The approach in decomposing the error mechanisms with the help of the LES flow field could be extended to more complex measurement scenarios and scans.

17 WIND ENERGY↗

Errors in determination of soil water content using time-domain reflectometry caused by soil compaction around wave guides

Application of time domain reflectometry (TDR) in soil hydrology often involves the conversion of TDR-measured dielectric permittivity to water content using universal calibration equations (empirical or physically based). Deviations of soil-specific calibrations from the universal calibrations have been noted and are usually attributed to peculiar composition of soil constituents, such as high content of clay and/or organic matter. Although it is recognized that soil disturbance by TDR waveguides may have impact on measurement errors, to our knowledge, there has not been any quantification of this effect. In this paper, we introduce a method that estimates this error by combining two models: one that describes soil compaction around cylindrical objects and another that translates change in bulk density to evolution of soil water retention characteristics. Our analysis indicates that the compaction pattern depends on the mechanical properties of the soil at the time of installation. The relative error in water content measurement depends on the compaction pattern as well as the water content and water retention properties of the soil. Illustrative calculations based on measured soil mechanical and hydrologic properties from the literature indicate that the measurement errors of using a standard three-prong TDR waveguide could be up to 10%. We also show that the error scales linearly with the ratio of rod radius to the interradius spacing.

54 ENVIRONMENTAL SCIENCES↗

Performance of the Gemini Planet Imager Non-redundant Mask and Spectroscopy of Two Close-separation Binaries: HR 2690 and HD 142527

The Gemini Planet Imager (GPI) contains a 10-hole non-redundant mask (NRM), enabling interferometric resolution in complement to its coronagraphic capabilities. The NRM operates both in spectroscopic (integral field spectrograph, henceforth IFS) and polarimetric configurations. NRM observations were taken between 2013 and 2016 to characterize its performance. Most observations were taken in spectroscopic mode, with the goal of obtaining precise astrometry and spectroscopy of faint companions to bright stars. We find a clear correlation between residual wavefront error measured by the adaptive optic system and the contrast sensitivity by comparing phase errors in observations of the same source, taken on different dates. We find a typical 5σ contrast sensitivity of (2–3) × 10 –3 at $~λ/D$. We explore the accuracy of spectral extraction of secondary components of binary systems by recovering the signal from a simulated source injected into several data sets. We outline data reduction procedures unique to GPI's IFS and describe a newly public data pipeline used for the presented analyses. We demonstrate recovery of astrometry and spectroscopy of two known companions to HR 2690 and HD 142527. NRM+polarimetry observations achieve differential visibility precision of σ ~ 0.4% in the best case. We discuss its limitations on Gemini-S/GPI for resolving inner regions of protoplanetary disks and prospects for future upgrades. We summarize lessons learned in observing with NRM in spectroscopic and polarimetric modes.

79 ASTRONOMY AND ASTROPHYSICS↗

Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (T ETRS , 30–40 °C), ambient temperature (T atm , 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of T atm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal T ETRS for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (T CS ) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, T atm of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.

47 OTHER INSTRUMENTATION↗

LiG Metrology, Correlated Error, and the Integrity of the Global Surface Air-Temperature Record

The published 95% uncertainty of the global surface air-temperature anomaly (GSATA) record through 1980 is impossibly less than the 2σ = ±0.25 °C lower limit of laboratory resolution of 1 °C/division liquid-in-glass (LiG) thermometers. The ~0.7 °C/century Joule-drift of lead- and soft-glass thermometer bulbs renders unreliable the entire historical air-temperature record through the 19th century. A circa 1900 Baudin meteorological spirit thermometer bulb exhibited intense Pb X-ray emission lines (10.55, 12.66, and 14.76 keV). Uncorrected LiG thermometer non-linearity leaves 1σ = ±0.27 °C uncertainty in land-surface air temperatures prior to 1981. The 2σ = ±0.43 °C from LiG resolution and non-linearity obscures most of the 20th century GSATA trend. Systematic sensor-measurement errors are highly pair-wise correlated, possibly across hundreds of km. Non-normal distributions of bucket and engine-intake difference SSTs disconfirm the assumption of random measurement error. Semivariogram analysis of ship SST measurements yields half the error difference mean, ±½Δε 1,2, not the error mean. Transfer-function adjustment following a change of land station air-temperature sensor eliminates measurement independence and forward-propagates the antecedent uncertainty. LiG resolution limits, non-linearity, and sensor field calibrations yield GSATA mean ±2σ RMS uncertainties of, 1900–1945, ±1.7 °C; 1946–1980, ±2.1 °C; 1981–2004, ±2.0 °C; and 2005–2010, ±1.6 °C. Finally, the 20th century (1900–1999) GSATA, 0.74 ± 1.94 °C, does not convey any information about rate or magnitude of temperature change.

54 ENVIRONMENTAL SCIENCES↗

THE MASS-RICHNESS RELATION OF MaxBCG CLUSTERS FROM QUASAR LENSING MAGNIFICATION USING VARIABILITY

Accurate measurement of galaxy cluster masses is an essential component not only in studies of cluster physics but also for probes of cosmology. However, different mass measurement techniques frequently yield discrepant results. The Sloan Digital Sky Survey MaxBCG catalog's mass-richness relation has previously been constrained using weak lensing shear, Sunyaev-Zeldovich (SZ), and X-ray measurements. The mass normalization of the clusters as measured by weak lensing shear is {approx}>25% higher than that measured using SZ and X-ray methods, a difference much larger than the stated measurement errors in the analyses. We constrain the mass-richness relation of the MaxBCG galaxy cluster catalog by measuring the gravitational lensing magnification of type I quasars in the background of the clusters. The magnification is determined using the quasars' variability and the correlation between quasars' variability amplitude and intrinsic luminosity. The mass-richness relation determined through magnification is in agreement with that measured using shear, confirming that the lensing strength of the clusters implies a high mass normalization and that the discrepancy with other methods is not due to a shear-related systematic measurement error. We study the dependence of the measured mass normalization on the cluster halo orientation. As expected, line-of-sight clusters yield a higher normalization; however, this minority of haloes does not significantly bias the average mass-richness relation of the catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

On the errors in measuring the particle density by the light absorption method

The accuracy of absorption measurements of the density of particles in a given quantum state as a function of the light absorption coefficient is analyzed. Errors caused by the finite accuracy in measuring the intensity of the light passing through a medium in the presence of different types of noise in the recorded signal are considered. Optimal values of the absorption coefficient and the factors capable of multiplying errors when deviating from these values are determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sources of the systematic errors in measurements of {sup 214}Po decay half-life time variations at the Baksan deep underground experiments

The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of {sup 214}Po half-life (τ) measurements up to the 2.5 × 10{sup −4} are described. Different possible sources of systematic errors influencing on the τ-value are studied. An annual variation of {sup 214}Po half-life time measurements with an amplitude of A = (6.9 ± 3) × 10{sup −4} and a phase of φ = 93 ± 10 days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours’ variation of the t-value measurements with an amplitude of A = (10.0 ± 2.6) × 10{sup −4} and phase of φ = 1 ± 0.5 hours was found in a solar day 1 hour step t-value sequence formed from the same data sample. It was found that the {sup 214}Po half-life averaged at 480 days is equal to 163.45 ± 0.04 μs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CT reconstruction techniques for improved accuracy of lung CT airway measurement

Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD FBP. Veo reconstructions showed slight improvement over STD FBP reconstructions (4%–9% increase in accuracy). The most improved ID and WA% measures were for the smaller airways, especially for low dose scans reconstructed at half DFOV (18 cm) with the EDGE algorithm in combination with 100% ASIR to mitigate noise. Using the BONE + ASIR at half BONE technique, measures improved by a factor of 2 over STD FBP even at a quarter of the x-ray dose. Conclusions: The flexibility of ASIR in combination with higher frequency algorithms, such as BONE, provided the greatest accuracy for conventional and low x-ray dose relative to FBP. Veo provided more modest improvement in qCT measures, likely due to its compatibility only with the smoother STD kernel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm{sup 2} field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ring retroreflector system consisting of cube-corner reflectors with special coating

The ring retroreflector system (RS) consisting of cubecorner reflectors (CCRs) with a special coating of reflecting surfaces, intended for uniaxially Earth-oriented navigation satellites, is considered. The error of distance measurement caused by both the laser pulse delay in the CCR and its spatial position (CCR configuration) is studied. It is shown that the ring RS, formed by the CCR with a double-spot radiation pattern, allows the distance measurement error to be essentially reduced. (nanogradient dielectric coatings and metamaterials)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parametrized process characterization with reduced resource requirements

Quantum process tomography (QPT) is a powerful tool to characterize quantum operations, but it requires considerable resources, making it impractical for more than two-qubit systems. This study proposes an alternative approach that requires significantly fewer resources for unitary process characterization with a built-in method for state preparation and measurement error mitigation. By measuring the quantum process as rotated through the X and Y axes on the Bloch sphere, we can acquire enough information to reconstruct the quantum process matrix χ and measure its fidelity. We test the algorithm's performance against standard QPT using simulated and physical experiments on several IBM quantum processors and compare the resulting process matrices. We demonstrate with numerical experiments that the method can improve gate fidelity via a noise reduction in the imaginary part of the process matrix, along with a stark decrease in the number of experiments needed to perform the characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗