Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

RF Reference Switch for Spaceflight Radiometer Calibration

The goal of this technology is to provide improved calibration and measurement sensitivity to the Soil Moisture Active Passive Mission (SMAP) radiometer. While RF switches have been used in the past to calibrate microwave radiometers, the switch used on SMAP employs several techniques uniquely tailored to the instrument requirements and passive remote-sensing in general to improve radiometer performance. Measurement error and sensitivity are improved by employing techniques to reduce thermal gradients within the device, reduce insertion loss during antenna observations, increase insertion loss temporal stability, and increase rejection of radar and RFI (radio-frequency interference) signals during calibration. The two legs of the single-pole double-throw reference switch employ three PIN diodes per leg in a parallel-shunt configuration to minimize insertion loss and increase stability while exceeding rejection requirements at 1,413 MHz. The high-speed packaged diodes are selected to minimize junction capacitance and resistance while ensuring the parallel devices have very similar I-V curves. Switch rejection is improved by adding high-impedance quarter-wave tapers before and after the diodes, along with replacing the ground via of one diode per leg with an open circuit stub. Errors due to thermal gradients in the switch are reduced by embedding the 50-ohm reference load within the switch, along with using a 0.25-in. (approximately equal to 0.6-cm) aluminum prebacked substrate. Previous spaceflight microwave radiometers did not embed the reference load and thermocouple directly within the calibration switch. In doing so, the SMAP switch reduces error caused by thermal gradients between the load and switch. Thermal issues are further reduced by moving the custom, highspeed regulated driver circuit to a physically separate PWB (printed wiring board). Regarding RF performance, previous spaceflight reference switches have not employed high-impedance tapers to improve rejection. The use of open-circuit stubs instead of a via to provide an improved RF short is unique to this design. The stubs are easily tunable to provide high rejection at specific frequencies while maintaining very low insertion loss in-band.

Knuble, Joseph↗

Advanced detectors and signal processing

Continued progress is reported toward development of a silicon on garnet technology which would allow fabrication of advanced detection and signal processing circuits on bubble memories. The first integrated detectors and propagation patterns have been designed and incorporated on a new mask set. In addition, annealing studies on spacer layers are performed. Based on those studies, a new double layer spacer is proposed which should reduce contamination of the silicon originating in the substrate. Finally, the magnetic sensitivity of uncontaminated detectors from the last lot of wafers is measured. The measured sensitivity is lower than anticipated but still higher than present magnetoresistive detectors.

Greve, D. W.↗

A psychophysiological evaluation of the perceived urgency of auditory warning signals

One significant concern that pilots have about cockpit auditory warnings is that the signals presently used lack a sense of priority. The relationship between auditory warning sound parameters and perceived urgency is, therefore, an important topic of enquiry in aviation psychology. The present investigation examined the relationship among subjective assessments of urgency, reaction time, and brainwave activity with three auditory warning signals. Subjects performed a tracking task involving automated and manual conditions, and were presented with auditory warnings having various levels of perceived and situational urgency. Subjective assessments revealed that subjects were able to rank warnings on an urgency scale, but rankings were altered after warnings were mapped to a situational urgency scale. Reaction times differed between automated and manual tracking task conditions, and physiological data showed attentional differences in response to perceived and situational warning urgency levels. This study shows that the use of physiological measures sensitive to attention and arousal, in conjunction with behavioural and subjective measures, may lead to the design of auditory warnings that produce a sense of urgency in an operator that matches the urgency of the situation.

Sound↗

NOAA-20 VIIRS polarization effect and its correction

The follow-on Visible Infrared Imaging Radiometer Suite (VIIRS) housed in the NOAA-20 satellite was launched on 18 November 2017. It has 22 spectral bands, among which 14 are reflective solar bands (RSBs) covering the wavelength range from 411 to 2258 nm. Prelaunch polarization sensitivity measurements have revealed that NOAA-20 VIIRS RSBs are much more sensitive to polarization of the incident light than its predecessor, the VIIRS on the Suomi National Polar-orbiting Partnership. For the short wavelength bands, i.e., M1–M4, the polarization sensitivities are out of specifications, especially for band M1, for which the polarization factors can be as large as ∼6%. The polarization effect induces striping in imagery along the track and radiometric bias both along the scan and along the track, resulting in much larger uncertainties in the environmental data records (EDR). In this paper, the polarization effect correction algorithms are described and applied to the NOAA-20 VIIRS RSBs for ocean scenes where the top-of-atmosphere radiance can be separated into the ocean normalized water-leaving radiance, the basis of the ocean color EDR, and the sunlight reflected by the atmosphere, which can be mostly described by the Rayleigh scattering radiance. The errors of the sensor data records (SDR or Level-1B radiance) due to the polarization effect can be as large as ∼1% for bands M1 and M2, and those in the ocean normalized water-leaving radiances are about 13% and 10% for wavelengths at 411 nm (band M1) and 445 nm (band M2), respectively. The polarization effect also induces strong striping in both NOAA-20 VIIRS RSB SDR and normalized water-leaving radiances. It is demonstrated that with the polarization correction applied, the aforementioned errors and artifacts are successfully removed.

NOAA-20↗

The measurement of carbon monoxide and methane in the National Capital Air Quality Control Region. I - Measurement systems

The Carbon Monoxide Pollution Experiment (COPE) and the National Capital Air Quality Control Region (NCAQCR) undertook a series of measurements of atmospheric CO and CH4 to determine the accuracy of the airborne COPE Correlation Interfer4meter. The device, a modified Michelson interferometer, measures the atmospheric column density of CO and CH4 at 2.3 microns with tropospheric measurement sensitivities of 70 and 10 PPB, respectively. Data for evaluating the remote measurements included atmospheric column density measurements at a ground truth site using a van-mounted infrared Fourier spectrometer; continuous ground level gas chromatographic measurements; and chromatographic data from atmospheric grab samples collected by aircraft and at ground locations. The instruments and sampling techniques used in the experiment are described in detail.

Lebel, P. J.↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background(CMB)science depend on increasing the number of sensitive detectorsobserving the sky. New instruments deploy large arrays of superconducting transition-edge sensor(TES)bolometers tileddensely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers andsimplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexingfactor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, whichemploys microwave SQUID multiplexing(μmux). Simons Observatory will use 49 modules containing 70,000bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design,presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor.The median white noise of each readout channel is 65pA Hz. This impacts the projected SO mapping speed by<8%,which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. Wediscuss the measured performance in the context of SO science requirements, which are exceeded.

Heather McCarrick↗

Infrared charge-injection-device array performance at low background

Low-background tests of a 1 x 32 Si:Bi charge-injection-device (CID) IR detector are carried out to evaluate its feasibility for space-based astronomical observations. Optimum performance is obtained at a temperature of 11 K. The sensitivity is found to compare well with that of discrete extrinsic silicon photoconductors. The measured sensitivity and the apparent absence of anomalous effects make extrinsic silicon CID arrays very promising for astronomical applications.

Mccreight, C. R.↗

On the performance of the scattering and crystal polarimeters for the Spectrum-X-Gamma mission

X-ray scattering from a lithium disk and Bragg reflection from a mosaic graphite crystal can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. The sensitivity is enhanced if the polarimeters are placed at the focus of an X-ray telescope. Such devices form two of the components of the Stellar X-ray Polarimeter experiment scheduled to fly on the Spectrum-X-Gamma mission. The expected on-axis performance of the two components is described based on detailed Monte Carlo simulations. The polarimetry experiment is expected to provide sensitive measurements of linear polarization for many cosmic X-ray sources. The nature and utility of such observations is described for pulsing X-ray sources such as the Crab pulsar and Her X-1.

Elsner, R. F.↗

Miniaturized Laser Heterodyne Radiometer for Measurements of CO2 in the Atmospheric Column

We have developed a low-cost, miniaturized laser heterodyne radiometer for highly sensitive measurements of carbon dioxide (CO2) in the atmospheric column. In this passive design, sunlight that has undergone absorption by CO2 in the atmosphere is collected and mixed with continuous wave laser light that is step-scanned across the absorption feature centered at 1,573.6 nm. The resulting radio frequency beat signal is collected as a function of laser wavelength, from which the total column mole fraction can be de-convolved. We are expanding this technique to include methane (CH4) and carbon monoxide (CO), and with minor modifications, this technique can be expanded to include species such as water vapor (H2O) and nitrous oxide (N2O).

CO2↗

The Stellar X-ray Polarimeter - A focal plane polarimeter for the Spectrum X-Gamma mission

This paper describes an X-ray polarimeter that will be flown on the Spectrum X-Gamma mission. The instrument exploits three distinct physical processes to measure polarization: Bragg reflection from a graphite crystal, Thomson scattering from a metallic lithium target, and photoemission from a cesium iodide photocathode. These three methods allow polarization measurements over an energy band from 0.3 to 12 keV. The polarimeter will make possible sensitive measurements of several hundred known X-ray sources. X-ray polarization measurements will make it possible to constrain the geometry of gas flow in X-ray binaries, identify nonthermal emission in supernova remnants, test current models for X-ray emission in radio pulsars, determine the radiation mechanisms in active galactic nuclei, and search for inertial frame dragging (Lense-Thirring effect) around the putative black hole in Cygnus X-1.

Kaaret, P.↗

The Gaseous Content of the Universe at Zeta less than 1.6

Together with graduate student Hsiao-Wen Chen, I have measured and analyzed structural and morphological parameters of 38 galaxies in eight fields for which sensitive measurements of corresponding Ly(alpha) absorption toward background QSOs are available. These measurements are based on Wide Field Planetary Camera 2 (WFPC2) observations obtained with the Hubble Space Telescope (HST) and provide a first look at how the incidence and extent of tenuous gas around galaxies depends on galaxy luminosity, size, and morphological type and on geometry of the impact. The primary result of the analysis is that the amount of gas encountered along the line of sight depends on the galaxy impact parameter and B-band luminosity but does not depend strongly on the galaxy average surface brightness, disk-to-bulge ratio, or redshift. This result confirms and improves upon an anti-correlation between Ly(alpha) absorption equivalent width and galaxy impact parameter found previously. More importantly, this result provides the first quantitative means of relating statistics of faint galaxies to statistics of Ly(alpha) absorption systems. which we plan to exploit to constrain the luminosity function of galaxies beyond the realm of current surveys. Results have been submitted for publication and will greatly improve our statistical conclusions . Together with graduate student Noriaki Yahata. I have measured and classified spectral properties of over 1000 faint galaxies and stars obtained in our low-resolution spectroscopic survey. The goal of this project is two-fold: (1) to exhaustively characterize the spectral properties of all faint galaxies that comprise our current survey, and (2) to gain experience with our measurement and classification code. which ultimately will be used on a data base of 20,000 galaxies to be obtained with the Two-Degree Field (2df) spectrograph at the Anglo-Australian Telescope (AAT). The results will ultimately be used for many goals, but so far we have concentrated on using the results to make a binary classification of the galaxies (i.e. early type versus late type) and to then exploit the density-morphology relationship to obtain a crude density indicator. The primary result of the analysis is that the incidence and extent of tenuous gas around galaxies shows no strong preference for local galaxy environment, at least over the range of densities spanned by the current observations. Along similar lines, two instances of Ly(alpha) absorption lines that arise in groups or clusters were examined. Analysis demonstrates that some can produce corresponding absorption lines and that LY(alpha) absorption lines do not avoid a high-density environment. A new measure of the galaxy-absorber cross-correlation function defines the statistical criterion by which galaxies and absorber pairs are to be matched. I have identified a damped Ly(alpha) absorption system at redshift z equals approximately 0.16, the lowest redshift confirmed to date. The most important results of the analysis are learning that the metal abundances of the absorption system are less than 10 percent of the solar metal abundance and that the absorbing gas is not rotating with the galaxy disk.

Source record↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro- polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with a gain of 2.0 +/- 0.5, less than or equal to 25 e- readout noise, less than or equal to 10 e-/second/pixel dark current, and less than 0.1percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; system gain, dark current, read noise, and residual non-linearity.

Champey, Patrick↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30%) quantum efficiency at the Lyman-$\alpha$ line. The CLASP cameras were designed to operate with ≤10 e- /pixel/second dark current, ≤ 25 e- read noise, a gain of 2.0 and ≤0.1% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, Patrick↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with 10 e-/pixel/second dark current, 25 e- read noise, a gain of 2.0 +/- 0.5 and 1.0 percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, P.↗

Thermoluminescence and the shock and reheating history of meteorites. II - Annealing studies of the Kernouve meteorite

Samples of the unshocked, equilibrated chondrite, Kernouve (H6), have been annealed for 1-100 hours at 500-1200 C, their thermoluminescence sensitivity measured and Na, K, Mn, Ca, and Sc determined by instrumental neutron activation analysis. The TL sensitivity decreased with temperature until by 1000 C it had fallen by 40 percent. The process responsible has an activation energy of 8 kcal/mole and probably involves diffusion. Samples annealed 1000-1200 C had TL sensitivities 0.01 times the unannealed values, most of the decrease occurring at 1100 C. This process has an activation energy of 100 kcal/mole and is probably related to the melting of the TL phosphor, feldspar, with some decomposition and loss of Cs, Na and K. Meteorites whose petrography indicates heating above 1100 C by natural shock heating events (shock facies d-f), have TL sensitivities similar to samples annealed above 1100 C.

Sears, D. W. G.↗

CO2 DIAL sensitivity studies for measurements of atmospheric trace gases

An analysis is presented of the accuracy of infrared differential absorption lidar (DIAL) measurements of trace constituents in the atmosphere. Expressions are derived for the signal-to-noise ratios applicable in the detection of a signal from a scattering cell for the cases of single-detection heterodyne detection and direct detection. Results of computer simulations of the expectation value of the measured return for various measurement conditions are presented which illustrate the sensitivities of plume measurements for horizontal range-resolved and vertical content measurements of NH3 in heterodyne and direct detection. Advantages for long-range measurements of the use of rare isotope laser frequencies, tuning by collision broadening, and closely spaced on and off frequencies are pointed out.

Brockman, P.↗

Preliminary design and performance of an advanced gamma-ray spectrometer for future orbiter missions

A knowledge of the composition of planets, satellites, and asteroids is of primary importance in understanding the formation and evolution of the solar system. Gamma-ray spectroscopy is capable of measuring the composition of meter-depth surface material from orbit around any body possessing little or no atmosphere. Measurement sensitivity is determined by detector efficiency and resolution, counting time and the background flux, while the effective spatial resolution depends upon the field-of-view and counting time together with the regional contrast in composition. The advantages of using germanium as a detector of gamma rays in space are illustrated experimentally and a compact instrument cooled by passive thermal radiation is described. Calculations of the expected sensitivity of this instrument at the moon and Mars show that at least a dozen elements should be measurable, twice the number which have been isolated in the Apollo gamma-ray data

Metzger, A. E.↗