At least 91 records · Page 5

Thermal Control and Enhancement of Heat Transport Capacity of Two-Phase Loops With Electrohydrodynamic Conduction Pumping

There are three kinds of electrohydrodynamics (EHD) pumping based on Coulomb force: induction pumping, ion-drag pumping, and pure conduction pumping. EHD induction pumping relies on the generation of induced charges. This charge induction in the presence of an electric field takes place due to a non-uniformity in the electrical conductivity of the fluid which can be caused by a non-uniform temperature distribution and/or an inhomogeneity of the fluid (e.g. a two-phase fluid). Therefore, induction pumping cannot be utilized in an isothermal homogeneous liquid. In order to generate Coulomb force, a space charge must be generated. There are two main mechanisms for generating a space charge in an isothermal liquid. The first one is associated with the ion injection at a metal/liquid interface and the related pumping is referred to as ion-drag pumping. Ion-drag pumping is not desirable because it can deteriorate the electrical properties of the working fluid. The second space charge generation mechanism is associated with the heterocharge layers of finite thickness in the vicinity of the electrodes. Heterocharge layers result from dissociation of the neutral electrolytic species and recombination of the generated ions. This type of pumping is referred to as pure conduction pumping. This project investigates the EHD pumping through pure conduction phenomenon. Very limited work has been conducted in this field and the majority of the published papers in this area have mistakenly assumed that the electrostriction force was responsible for the net flow generated in an isothermal liquid. The main motivation behind this study is to investigate an EHD conduction pump for a two-phase loop to be operated in the microgravity environment. The pump is installed in the liquid return passage (isothermal liquid) from the condenser section to the evaporator section. Unique high voltage and ground electrodes have been designed that generate sufficient pressure heads with very low electric power requirements making the EHD conduction pumping attractive to applications such as two-phase systems (e.g. capillary pumped loops and heat pipes). Currently, the EHD conduction pump performance is being tested on a two-phase loop under various operating conditions in the laboratory environment. The simple non-mechanical and lightweight design of the EHD pump combined with the rapid control of performance by varying the applied electric field, low power consumption, and reliability offer significant advantages over other pumping mechanisms; particularly in reduced gravity applications.

Seyed-Yagoobi, J.↗

Flight Test Results for the HST Orbital Systems Test (HOST) Capillary Pump Loop Cooling System

The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope (MST) in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will significantly shorten the instrument's useful life. A reverse Brayton cycle mechanical refrigerator will be installed during the Third Servicing Mission (SM3) to provide cooling for the instrument, and thereby extend its operations. A Capillary Pump Loop (CPL) and radiator system was designed, built and tested to remove up to 500 watts of heat from the mechanical cryocooler and its associated electronics. The HST Orbital Systems Test (HOST) platform was flown on the Space Shuttle Discovery (STS-95) as a flight demonstration of the cryocooler system, CPL control electronics, and the CPL/Radiator. This paper will present the flight test results and thermal performance of the CPL system in detail.

Buchko, M.↗

Design of a Mechanical NaK Pump for Fission Space Power

Alkali liquid metal cooled fission reactor concepts are under development for spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid, which has specific pumping requirements. Traditionally, electromagnetic linear induction pumps have been used to provide the required flow and pressure head conditions for NaK systems but they can be limited in performance, efficiency, and number of available vendors. The objective of the project was to develop a mechanical NaK centrifugal pump that takes advantages of technology advances not available in previous liquid metal mechanical pump designs. This paper details the design, build, and performance test of a mechanical NaK pump developed at NASA Marshall Space Flight Center. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

Mireles, Omar R.↗

Design of a Mechanical NaK Pump for Fission Space Power Systems

Alkali liquid metal cooled fission reactor concepts are under development for mid-range spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid. Traditionally, linear induction pumps have been used to provide the required flow and head conditions for liquid metal systems but can be limited in performance. This paper details the design, build, and check-out test of a mechanical NaK pump. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

Mireles, Omar R.↗

Design and performance oof space station photovoltaic radiators

The design and performance of the Space Station Freedom Photovoltaic (PV) Power Module Thermal Control System radiators is presented. The PV Radiator is of a single phase pumped loop design using liquid ammonia as the coolant. Key design features are described, including the base structure, deployment mechanism, radiator panels, and two independent coolant loops. The basis for a specific mass of 7.8 kg/sqm is discussed, and methods of lowering this number for future systems are briefly described. Key performance paramters are also addressed. A summary of test results and analysis is presented to illustrate the survivability of the radiator in the micrometeoroid and orbital debris environment. A design criterion of 95% probability of no penetration of both fluid loops over a 10 year period is shown to be met. Methods of increasing the radiator survivability even further are presented. Thermal performance is also discussed, including a comparison of modeling predictions with existing test results. Degradation in thermal performance due to exposure to atomic oxygen and ultraviolet radiation in the low Earth orbit environment is presented. The structural criteria to which the radiator is designed are also briefly addressed. Finally, potential design improvements are discussed.

White, K. Alan↗

Two-Pipe Heat-Transfer Loop

Device like heat pipe transports heat over long distance with negligible loss in temperature, though with considerably smaller total weight. Uses no pumps or other mechanical means to move working fluid: Instead converts part of available thermal energy to kinetic energy upon vaporization. Vapor carries thermal energy in form of latent heat of vaporization. Delivers thermal energy with drop in temperature of only fraction of degree from source sink.

Richter, Robert↗

Self-contained heat rejection module for future spacecraft

This paper discusses development of a Self-Contained Heat Rejection Module (SHRM) which can be used on a wide variety of future spacecraft launched by the space shuttle orbiter. The SHRM contains radiators which are deployed by a scissor-mechanism and the flow equipment including pumps, accumulator, by-pass valves, and controllers necessary to reject heat from those radiators. Heat transfer between SHRM and the parent vehicle is effected by a contact heat exchanger. This device provides heat transfer between two separate flow loops through a mechanical connection. This approach reduces the time required to attach the SHRM to the payload, and increases the reliability of the SHRM flow loop since breaking into the fluid system in the field is not required. The SHRM concept also includes a refrigeration system to increase heat rejection capacity in adverse environments, or to provide for a lower return temperature, down to -23 C.

Fleming, M. L.↗

Design of an advanced two-phase capillary cold plate

The functional principles and implementation of capillary pumped loop (CPL) two phase heat transport system for various elements of the Space Station program are described. Circulation of the working fluid by the surface-tension forces in a fine-pore capillary wick is the core principle of CPL systems. The liquid, usually NH3 at the moment, is changed into a vapor by heat absorption at one end of the loop, and the vapor is carrried back along the wick by the surface tension within the wick. NASA specifications and the results of mechanical and thermal tests for prototype cold plate and the capillary pump designs are outlined. The CPL is targeted for installation on free-flying platforms, attached payloads, and power subsystem thermal control systems.

Chalmers, D. R.↗

The mechanical design of a vapor compressor for a heat pump to be used in space

A heat pump developed for use in Spacelab as a stand-alone refrigeration unit as well as within a fluid loop system is discussed. It will provide an active thermal control for payloads. Specifications for the heat pump were established: (1) heat removal rates at the source; (2) heat source temperatures from room temperature; (3) heat-sink fluid temperatures at condenser inlet; and (4) minimum power consumption. A reversed Carnot cycle heat pump using Freon 12 as working fluid incorporating a one-cylinder reciprocating compressor was selected. The maximum crankshaft speed was fixed relatively high at 100 rpm. The specified cooling rates then made it necessary to select a cylinder volume of 10 cu cm, which was obtained with a bore of 40 mm and a stroke of 8 mm.

Berner, F.↗

Development of a flow feedback pulse duplicator system with rhesus monkey arterial input impedance characteristics

An in vitro pulsatile pump flow system that is capable of producing physiologic pressures and flows in a mock circulatory system tuned to reproduce the first nine harmonics of the input impedance of a rhesus monkey was developed and tested. The system was created as a research tool for evaluating cardiovascular function and for the design, testing, and evaluation of electrical-mechanical cardiovascular models and chronically implanted sensors. The system possesses a computerized user interface for controlling a linear displacement pulsatile pump in a controlled flow loop format to emulate in vivo cardiovascular characteristics. Evaluation of the pump system consisted of comparing its aortic pressure and flow profiles with in vivo rhesus hemodynamic waveforms in the time and frequency domains. Comparison of aortic pressure and flow data between the pump system and in vivo data showed good agreement in the time and frequency domains, however, the pump system produced a larger pulse pressure. The pump system can be used for comparing cardiovascular parameters with predicted cardiovascular model values and for evaluating such items as vascular grafts, heart valves, biomaterials, and sensors. This article describes the development and evaluation of this feedback controlled cardiovascular dynamics simulation modeling system.

Non-NASA Center↗

Optimization Considerations for Annular Linear Electromagnetic Pumps for Space Nuclear Power and Propulsion

The Need for High Performance Liquid Metal Pumps Testing Power and Efficiency Considerations Liquid metal cooled reactors is one option for space nuclear power for settlements and electric propulsion vehicles (Snap 10 A, SP100, Soviet Topaz reactors) • High heat capacity • High boiling point (NaK~1200K) • Simplified heat transfer loop • Good neutronics Liquid metal EM pumps are desired over conventional pumps owing to lack of seals, bearings elimination of cavitation issues, lower mass and eliminates mechanical impeller • Conduction pumps (typically DC-high current, low voltage; ~5% efficiency) • Induction pumps (typically AC, high efficiency ~40%) Annular linear induction pump is an EM pump with no moving parts and of cylindrical/tubular geometry which makes it straightforward to integrate in conventional piping architectures • Higher inherent reliability • Invented by Einstein and Szilard

ALIP↗

Evaluation of advanced component concepts for an integrated environmental control/life support, resistojet control system

Flow restricting devices were studied for their suitability as liquid water propellant flow limiters for the biowaste resistojet. Flow limiting during the start-up transient is required to prevent thrustor instabilities and icing which could result in heater failure in the electrical resistance heated thrustor (resistojet). The study was directed toward simple devices which would function passively (i.e., without power except from the propellant flow itself), and would offer high reliability and simplicity. In addition to the flow limiting devices, a thermal pumping system was studied to determine whether CO2, desorbed from molecular sieves could be pumped thermally in a space station application. The thermal pump is considered a possible replacement for mechanical pumps. It involves a cyclic, constant volume cryopumping system which employs space radiators to achieve the cryotemperatures. The frozen CO2 would be vaporized periodically, using a waste heat loop, to attain sufficient pressure to transfer a large portion of the trapped CO2 to storage tanks.

Halbach, C. R.↗

NaK Plugging Meter Design for the Feasibility Test Loops

The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

Pearson, J. Boise↗

A unified theory of electrodynamic coupling in coronal magnetic loops - The coronal heating problem

The coronal heating problem is studied, and it is demonstrated that Ionson's (1982) LRC approach results in a unified theory of coronal heating which unveils a variety of new heating mechanisms and which links together previously proposed mechanisms. Ionson's LRC equation is rederived, focusing on various aspects that were not clarified in the original article and incorporating new processes that were neglected. A parameterized heating rate is obtained. It is shown that Alfvenic surface wave heating, stochastic magnetic pumping, resonant electrodynamic heating, and dynamical dissipation emerge as special cases of a much more general formalism. This generalized theory is applied to solar coronal loops and it is found that active region and large scale loops are underdamped systems. Young active region loops and (possibly) bright points are found to be overdamped systems.

Ionson, J. A.↗

Free-Piston Stirling Power Conversion Unit for Fission Surface Power, Phase I Final Report

This report summarizes the design of a 12 kW dual opposed free-piston Stirling convertor and controller for potential future use in space missions. The convertor is heated via a pumped NaK loop and cooling is provided by a pumped water circuit. Convertor efficiency is projected at 27 percent (AC electrical out/heat in). The controller converts the AC electrical output to 120 Vdc and is projected at 91 percent efficiency. A mechanically simple arrangement, based on proven technology, was selected in which the piston is resonated almost entirely by the working space pressure swing, while the displacer is resonated by planar mechanical springs in the bounce space.

Wood, J. Gary↗

Flight Testing of a Cryogenic Capillary Pumped Loop

Future space-based cryogenic systems will require enhanced integration flexibility, lower weight reduced parasitic penalties, better vibration isolation, and a variety of other improvements to meet performance goals. Additionally, there is an increasing need to locate cooling sources remotely from cooled components. In the past flexible conductive links were used and worked well in most cases. However, as the transport lengths increase, conductive couplings become heavier and less effective, and must be replaced by higher performance systems. One available option, which can meet many of these future requirements, is the cryogenic capillary pumped loop (CCPL). The development of the CCPL technology started in 1992, following the success of the room temperature CPLS. The extrapolation of CCPL technology to cryogenic temperatures offers many performance benefits, which are not currently within the reach of traditional heat pipes or conductive links. Specific advantages of the CCPL technology pertaining to cryocooler integration include: (1) greater capillary pumping pressure for improved ground testability; (2) improved mechanical isolation; (3) faster diode shutdown and lower reverse heat leaks; (4) tighter control of detector temperature; (5) variable or fixed conductance operation; and (6) ease of integration due to their flexibility. The applications of CCPL technology are numerous. Military and commercial applications include surveillance satellites, earth observing satellites, deep space observation systems, medical devices, and many other cryogenic systems. Over the past few years, several breadboard and prototype CCPLs have been built and ground tested. A prototype CCPL has demonstrated successful operation between 80K and 110K with heat loads between O.5W and 12W using nitrogen as the working fluid, and 35K and 40K with head loads of 0.25W to 3.5W using neon. In order to verify CCPL performance in a microgravity environment, a flight unit, CCPL-5, was tested onboard the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5W as well as with parasitic heat loads alone. There were no noticeable differences between zero-G and one-G operation.

Ku, Jentung↗

Capillary-Driven Heat Transfer Experiment: Keeping It Cool in Space

Capillary-pumped loops (CPL's) are devices that are used to transport heat from one location to another--specifically to transfer heat away from something. In low-gravity applications, such as satellites (and possibly the International Space Station), CPL's are used to transfer heat from electrical devices to space radiators. This is accomplished by evaporating one liquid surface on the hot side of the CPL and condensing the vapor produced onto another liquid surface on the cold side. Capillary action, the phenomenon that causes paper towels to absorb spilled liquids, is used to "pump" the liquid back to the evaporating liquid surface (hot side) to complete the "loop." CPL's require no power to operate and can transfer heat over distances as large as 30 ft or more. Their reliance upon evaporation and condensation to transfer heat makes them much more economical in terms of weight than conventional heat transfer systems. Unfortunately, they have proven to be unreliable in space operations, and the explanation for this unreliability has been elusive. The Capillary-Driven Heat Transfer (CHT) experiment is investigating the fundamental fluid physics phenomena thought to be responsible for the failure of CPL's in low-gravity operations. If the failure mechanism can be identified, then appropriate design modifications can be developed to make capillary phase-change heat-transport devices a more viable option in space applications. CHT was conducted onboard the Space Shuttle Columbia during the first Microgravity Science Laboratory (MSL-1) mission, STS-94, which flew from July 1 to 17, 1997. The CHT glovebox investigation, which was conceived by Dr. Kevin Hallinan and Jeffrey Allen of the University of Dayton, focused on studying the dynamics associated with the heating and cooling at the evaporating meniscus within a capillary phase-change device in a low-gravity environment. The CHT experimental hardware was designed by a small team of engineers from Aerospace Design & Fabrication (ADF), the NASA Lewis Research Center, and the University of Dayton. The hardware consisted of two experiment modules that each contained an instrumented test loop (idealized capillary-pumped loop), a base unit for power conversion and backlighting, a display unit with 15 LED's (light-emitting diodes) to display temperatures, pressure, heater power, and time, a control unit to select heaters and heater settings, a cooling fan, and associated cables.

Lekan, Jack F.↗