Search NASA⌕ Search

SEARCH · Search NASA

Results for “membrane electrode assembly (MEA)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electrochemical Device Comprising an Electrically-Conductive, Selectively-Permeable Membrane

An electrochemical device, such as a fuel cell or an electrolyzer. In one embodiment, the electrochemical device includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, the membrane including a solid polymer electrolyte and a non-particulate, electrically-conductive material, such as carbon nanotubes, carbon nanofibers, and/or metal nanowires. In addition, each bipolar plate also includes an electrically-conductive fluid chamber in contact with the electrically-conductive, selectively-permeable membrane and further includes a non-porous and electrically-conductive plate in contact with the fluid chamber.

Mittelsteadt, Cortney K.↗

Analysys of the performance a PEM-type electrolyzer in variable energy supply conditions

Here in this article, the main variables related to the performance of a proton exchange membrane-type electrolyzer are analyzed along with the risk of explosion for different operating conditions, notably when the electrolyzer works with a variable solar energy power supply and at high pressure. A novel mathematical model was developed that considers all mass transport phenomena through the membrane electrode assembly (MEA) for water, hydrogen, and oxygen, as well as the water evaporation in the anode and cathode channels. The main findings of this work are that for a solar energy supply operating at high pressure, the electrolyzer cannot function safely throughout the day, since in the hours when solar irradiation is lower, low current densities favor high hydrogen concentrations at the anode. Finally, it was found that greater thicknesses of the membrane increased the explosion risk due to the increase in the MEA temperature and therefore the hydrogen solubility.

08 HYDROGEN↗

Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

Mittelsteadt, Cortney K.↗

Electrochemical Device Comprising Composite Bipolar Plate and Method of Using the Same

An electrochemical device and methods of using the same. In one embodiment, the electrochemical device may be used as a fuel cell and/or as an electrolyzer and includes a membrane electrode assembly (MEA), an anodic gas diffusion medium in contact with the anode of the MEA, a cathodic gas diffusion medium in contact with the cathode, a first bipolar plate in contact with the anodic gas diffusion medium, and a second bipolar plate in contact with the cathodic gas diffusion medium. Each of the bipolar plates includes an electrically-conductive, chemically-inert, non-porous, liquid-permeable, substantially gas-impermeable membrane in contact with its respective gas diffusion medium, as well as a fluid chamber and a non-porous an electrically-conductive plate.

Mittelsteadt, Cortney K.↗

Degradation Mechanisms in Advanced MEAs for PEM Water Electrolyzers Fabricated by Reactive Spray Deposition Technology

Proton exchange membrane water electrolyzers (PEMWEs) have demonstrated enormous potential as the next generation hydrogen production technology. The main challenges that the state-of-the-art PEMWEs are currently facing are excessive cost and poor durability. Understanding the failure modes in PEMWEs is a key factor for improving their durability, lowering the precious metal loading, and hence cost reduction. Here, reactive spray deposition technology (RSDT) has been used to fabricate a membrane electrode assembly (MEA) with one order of magnitude lower Pt and Ir catalyst loadings (0.2–0.3 mg PGM cm –2 ) in comparison to the precious metal loadings in the stat-of-the-art commercial MEAs (2–3 mg PGM cm –2 ). As fabricated MEA with an active area of 86 cm 2 , has been tested for over 5000 h at steady-state conditions that are typical for an industrial hydrogen production system. Herein, we present and discuss the results from a comprehensive post-test analysis of the MEA of interest. The main degradation mechanisms, governing the performance loss in the RSDT fabricated MEA with ultra-low precious metal loadings, have been identified and discussed in detail. All failure modes are critically compared and the main degradation mechanism with the highest impact on the MEA performance loss among the others is identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

International Meeting on Fuel Cell and Electrolyzer Quality Control: Summary Report

Quality control (QC) for both polymer electrolyte membrane fuel cell and electrolysis membrane electrode assembly (MEA) materials is a key challenge for scale-up and cost reduction. Developing methods for detecting defects, as well as measuring critical material properties and understanding the impact of as-manufactured variations in these materials on cell performance and lifetime, are critical barriers. To help address these needs, the National Research Council Canada (NRC), Fraunhofer Institute for Solar Energy Systems (ISE), and the National Renewable Energy Laboratory (NREL) have organized and facilitated a series of workshops on the topic, bringing together industry, academia, and research institutions from North America and Europe. Prior workshops in Canada and Germany have focused on the status of quality tool capabilities and identification of needed developments for fuel cells. These meetings have garnered an excellent response and follow-on attendance, with over 100 unique attendees.

30 DIRECT ENERGY CONVERSION↗

Multi-technique characterization of spray coated and roll-to-roll coated gas diffusion fuel cell electrodes

Here this work reports the characterization of catalyst layer (CL) structure and composition for a set of gas-diffusion electrodes (GDEs) fabricated by different coating methods with the goal of developing a better understanding of CL processing-structure-property-performance relationships. The CL coating techniques used in this study were ultrasonic spray coating, and two roll-to-roll (R2R) methods - gravure and slot die. Scanning transmission electron microscopy (STEM) coupled with X-ray energy dispersive spectroscopy (EDS) analysis of GDE cross-sections provided bulk information, while scanning electron microscopy (SEM) with EDS and X-ray photoelectron spectroscopy (XPS) were used to investigate the near surface and surface composition of the CLs that will be in direct contact with the membrane once the membrane electrode assembly (MEA) is constructed. This study demonstrates that common quantification parameters, namely the F:Pt ratio extracted from cross-sectional STEM-EDS maps and top-down CL measurements with SEM and XPS, along with roughness parameters quantified from SEM micrographs are useful parameters in explaining and potentially predicting performance trends. Additionally, it highlights the importance of understanding key CL surface properties for advancing the manufacturability of high-performance components for polymer electrolyte membrane (PEM) technologies.

30 DIRECT ENERGY CONVERSION↗

Fuel Cell Membrane Electrode Assemblies with Ultra-Low Pt Nanofiber Electrodes (Final Report)

H 2 /air fuel cell membrane-electrode-assemblies (MEAs) were fabricated with electrospun particle/polymer nanofiber mat cathodes (0.1 mg Pt /cm 2 or 0.2 mg Pt /cm 2 Pt/C, PtCo/C or PtNi/C) and anodes (0.1 mg/cm 2 Pt/C), where the binder was a mixture of acid-form perfluorosulfonic acid ionomer (e.g., Nafion™) and poly(acrylic acid) (PAA) carrier polymer or sodium-form PFSA with a carrier polymer of either PAA or polyethylene oxide (PEO). For the latter two cases, the water-soluble carrier was removed from the fibers after electrospinning. MEAs with Pt/C anode/cathode catalyst loadings of 0.1 mg Pt /cm2 each, an 1100 EW PFSA binder (Nafion™ dispersion), and a Nafion 211 membrane produced high power at both high and low relative humidity (RH) conditions, e.g., a maximum power density of 919 mW/cm 2 at 100% RH and 832 mW/cm 2 at 40% RH for a test at 80 °C and 200 kPa abs . The high power at low RH was attributed to nm-size pores within the fibers that trap water via capillary condensation thus maintaining a high proton conductivity of the PFSA binder in the cathode and especially the anode while minimizing/eliminating ionic isolation of catalyst particles in low water content, poorly conductive binder. At the same time, micro-porosity between fibers in the cathode allows for fast removal of electrogenerated water, thus minimizing cathode flooding. Nanofiber MEAs with Pt alloy catalyst cathodes also performed well, where a fibrous PtCo/C catalyst cathode at a loading of 0.1 mg/cm 2 produced 20% more power than a conventional powder cathode MEA, e.g., a maximum power density of 1,045 mW/cm 2 vs. 869 mW/cm 2 at 80 °C, 100% RH, and 200 kPa abs , and a PtNi/C fiber cathode MEAs prepared with Na+-form Nafion + PEO generated a maximum power of 820 mW/cm 2 at 40% RH. Fiber electrode MEAs with a neat Nafion binder (prepared from Na+-form Nafion + PEO or PAA) where the cathode Pt loading was ~0.1 mg/cm 2 exhibited a 25% loss in maximum power at 30,000 metal dissolution cycles, as compared to a 12% loss when the cathode binder was H+-form Nafion + PAA. The performance of a fiber mat electrode MEA with Pt/C catalyst (0.2 mg/cm 2 cathode loading and 0.1 mg/cm 2 anode loading) was excellent. At 80 oC and 200 kPa abs , the maximum power density was 1104 mW/cm 2 . The maximum power was independent of feed gas humidity for 40 < RH < 100%. The power loss after a metal dissolution AST (30,000 voltage cycles) was only 13%.

08 HYDROGEN↗

Recent advances in integrating platinum group metal-free catalysts in proton exchange membrane fuel cells

Platinum group metal (PGM)-free catalysts are promising low-cost materials for the oxygen reduction reaction in proton exchange membrane fuel cells (PEMFCs). A variety of chemical precursors and synthesis methods have been proposed to increase their catalytic activity. In comparison, significantly less attention has been dedicated to the integration of these PGM-free catalysts into operating electrodes by investigating the role of the membrane electrode assembly (MEA) fabrication on the PEMFC performance. Here, we discuss here some remarkable performance improvements recently achieved by tuning catalyst loading, ionomer content, and ink solvent composition, and call for further explorations of the ink processing and MEA fabrication to improve performance.

25 ENERGY STORAGE↗

Anion-exchange membranes with internal microchannels for water control in CO 2 electrolysis

Electrochemical reduction of carbon dioxide (CO 2 R) poses substantial promise to convert abundant feedstocks (water and CO 2 ) to value-added chemicals and fuels using solely renewable energy. However, recent membrane-electrode assembly (MEA) devices that have been demonstrated to achieve high rates of CO 2 R are limited by water management within the cell, due to both consumption of water by the CO 2 R reaction and electro-osmotic fluxes that transport water from the cathode to the anode. Additionally, crossover of potassium (K + ) ions poses concern at high current densities where saturation and precipitation of the salt ions can degrade cell performance. Herein, a device architecture incorporating an anion-exchange membrane (AEM) with internal water channels to mitigate MEA dehydration is proposed and demonstrated. A macroscale, two-dimensional continuum model is used to assess water fluxes and local water content within the modified MEA, as well as to determine the optimal channel geometry and composition. The modified AEMs are then fabricated and tested experimentally, demonstrating that the internal channels can both reduce K + cation crossover as well as improve AEM conductivity and therefore overall cell performance. This work demonstrates the promise of these materials, and operando water-management strategies in general, in handling some of the major hurdles in the development of MEA devices for CO 2 R.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel platinum group metal-free catalyst ink deposition system for combinatorial polymer electrolyte fuel cell performance evaluation

Here, a new system for rapid and precise fabrication of polymer electrolyte fuel cell (PEFC) membrane-electrode assemblies (MEAs) is introduced to facilitate rapid testing and characterization of platinum group metal-free (PGM-free) catalysts, with minimal waste of materials, using commercial combinatorial hardware and multi-channel potentiostat. The commercial combinatorial system, designed for high-throughput catalyst activity evaluation (i.e., low overpotential and current densities) using gas-diffusion electrodes (GDEs), has been further developed to enable simultaneous evaluation of the high current density performance on air of twenty-five cathodes prepared by coating catalyst-ionomer inks directly onto the membrane using a newly-developed deposition system. A nanopipette or micropipette coupled to a precise peristaltic pump is being used for precise and even catalyst ink deposition onto the membrane in each of twenty-five circular electrodes with areas of <1 cm 2 and in the precise locations required by the commercial combinatorial MEA hardware. The automated ink deposition system is coupled with a custom-designed heated vacuum table mounted on a computer-controlled XY stage to prevent deformation of the membrane and electrode layers during ink deposition onto the membrane. This system was utilized to evaluate the impact of ionomer to catalyst ratio on the hydrogen-air fuel cell performance of the PGM-free catalyst.

25 ENERGY STORAGE↗

High-performance and cost-effective membrane electrode assemblies for advanced proton exchange membrane water electrolyzers: Long-term durability assessment

In this work, improved activity and durability performance of a two-cell (86 cm 2 ) proton exchange membrane water electrolyzer (PEMWE) stack is reported for the first time. Both membrane electrode assemblies (MEAs) contain one order of magnitude lower platinum group metal (PGM) loadings compared to the state-of-the-art PEMWEs and incorporate novel Pt recombination layers. The high-performance and cost-effective MEAs are fabricated by the unique reactive spray deposition technology (RSDT). This advanced methodology allows for one-step fabrication of MEAs and ensures precise control and distribution of the catalyst composition and loading. The RSDT-fabricated MEAs contain only 0.2 and 0.3 mg PGM cm –2 loading in the cathode and anode electrodes, respectively, and demonstrate excellent activity and durability for over 3000 h of operation at industrially-relevant operating conditions without showing significant loss in performance. This novel work shows that a significant cost reduction for PEMWEs is achieved while maintaining excellent durability, high catalysts activities, and low hydrogen cross-over.

Proton exchange membrane water electrolyzer↗

Effects of Ink Formulation on the Structure and Performance of PGM-Free Catalyst Layer in PEMFCs

Platinum group metal (PGM) catalysts are the major electrocatalysts for oxygen reduction reaction (ORR) in the polymer electrolyte membrane fuel cells (PEMFCs). The cost becomes unaffordable if the PEMFC is in massive application. The PGM-Free catalyst shows very promising activity in rotation disk electrode (RDE) testing. The half-wave potential could reach 0.91 V versus standard hydrogen electrode (SHE). However, in a membrane electrode assembly (MEA), the performance of PGM-Free catalysts is not good enough to replace the PGM catalysts. Since the PGM-free catalysts are so different from the PGM catalysts in terms of catalytic activity, stability, surface conditions, particle size, etc., the fabrication of PGM-Free catalyst MEA cannot simply copy the method of making PGM MEA. Here we proposed a novel method of fabricating PGM-Free catalyst MEA, so that the intrinsic catalyst activity from RDE can be translated into MEA performance. The method is based on the catalyst coated membrane (CCM) method using optimized ionomer to carbon (I/C) ratio and solvent mixture of catalyst ink. Using this method, the PGM-free catalyst MEA achieved the current density 44.9 mA cm -2 at 0.9 V iR-free in H 2 /O 2 and 150 mA cm -2 at 0.8 V in H 2 /air, which surpassed the performance targets of US Department of Energy (DOE)for PGM-Free catalyst MEA. The property (solvent composition, dispersion of catalyst and ionomer in an ink), structure (pore structure) and the MEA performance have been characterized using, mercury intrusion porosimetry (MIP), MEA testing. A property-structure-performance relationship has been established.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prediction of Performance Variation Caused by Manufacturing Tolerances and Defects in Gas Diffusion Electrodes of Phosphoric Acid (PA)–Doped Polybenzimidazole (PBI)-Based High-Temperature Proton Exchange Membrane Fuel Cells

The automated process of coating catalyst layers on gas diffusion electrodes (GDEs) for high-temperature proton exchange membrane fuel cells results inherently into a number of defects. These defects consist of agglomerates in which the platinum sites cannot be accessed by phosphoric acid and which are the consequence of an inconsistent coating, uncoated regions, scratches, knots, blemishes, folds, or attached fine particles—all ranging from μm to mm size. These electrochemically inactive spots cause a reduction of the effective catalyst area per unit volume (cm2/cm3) and determine a drop in fuel cell performance. A computational fluid dynamics (CFD) model is presented that predicts performance variation caused by manufacturing tolerances and defects of the GDE and which enables the creation of a six-sigma product specification for Advent phosphoric acid (PA)-doped polybenzimidazole (PBI)-based membrane electrode assemblies (MEAs). The model was used to predict the total volume of defects that would cause a 10% drop in performance. It was found that a 10% performance drop at the nominal operating regime would be caused by uniformly distributed defects totaling 39% of the catalyst layer volume (~0.5 defects/μm2). The study provides an upper bound for the estimation of the impact of the defect location on performance drop. It was found that the impact on the local current density is higher when the defect is located closer to the interface with the membrane. The local current density decays less than 2% in the presence of an isolated defect, regardless of its location along the active area of the catalyst layer.

Gurau, Vladimir (ORCID:0000000327429061)↗

Evaluation of IrO 2 catalysts doped with Ti and Nb at industrially relevant electrolyzer conditions: A comprehensive study

A series of commercial Oxygen Evolution Reaction (OER) IrO 2 -based materials doped with acid-stable titanium and niobium species were comprehensively characterized by Brunauer-Emmett-Teller (BET), X-ray diffraction analysis (XRD), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM) with energy dispersive spectroscopy (EDS), and X-ray Scattering. Electrocatalysts were integrated into Membrane Electrode Assembly (MEA) using a fabrication method developed under the US DOE H2NEW consortium. An electrolysis performance in a commercial setup as well as a laboratory screening system was performed at conditions relevant to industrial application. According to the comprehensive characterizations, the studied materials are closer to doped iridium oxides rather than core–shell structures. In an electrolysis cell, the IrO 2 /TiO x catalyst slightly outperforms the IrO 2 /NbO x based on the activity. It was demonstrated that the operation of electrolysis cells at elevated temperatures and the implementation of thinner Nafion-type membranes allows for substantially increased performance, which is consistent with the literature report. Finally, this work provides valuable baselines including characterization and performance for guiding future research in this direction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental measurements of fuel and water crossover in an active DMFC

This work measured polarization curves as well as the high-frequency resistance of active direct methanol fuel cell (DMFC) operates at around 80 °C with active controls of temperature, methanol concentration, airflow rate, and relative humidity. The relative humidity of the air did not have noticeable impacts on the fuel cell unless the operating temperature was near the evaporation temperature of water (100 °C). The hydrophobic water management layer (WML) between the membrane electrode assembly (MEA) and cathode air channel increases the mass transfer resistance and improves the water retention in MEA. Adding a WML increased the peak power density, decreased the ohmic resistance, and improved the fuel efficiency of the fuel cell, especially when it operated near 100 °C. This study also quantitatively measured methanol and water crossover as well as the fuel efficiency at different operating currents. The fuel efficiency increased significantly with the increase of the current density. Using a hydrophobic fuel management layer (FML) between the anode fuel channel and MEA reduced the fuel and water crossover rates and increased the ohmic resistance due to the decrease of the water content of the Nafion membrane. The FML improved fuel efficiency by reducing the methanol crossover. The combination of the FML and WML enabled the steady operation of DMFC using highly concentrated methanol solutions (up to 75 wt%).

08 HYDROGEN↗

The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

Integrated Reference Electrodes in Anion-Exchange-Membrane Electrolyzers: Impact of Stainless-Steel Gas-Diffusion Layers and Internal Mechanical Pressure

Alkaline-membrane electrolyzers operating in pure water might provide scalable low-cost H 2 production but currently lag in performance and durability compared to commercial technologies. Typically, membrane–electrode assemblies (MEAs) are optimized in electrolyzers by changing one parameter at a time and assessing the resulting system performance via two-electrode polarization and impedance measurements. These approaches are limited in their ability to assign performance changes and durability to specific electrodes or processes. We integrate a reference electrode with the MEA to separate anode and cathode responses in both polarization and impedance measurements. Here we illustrate the power of the approach by showing how the fiber diameter of stainless-steel gas-diffusion layers (GDLs) affects performance solely at the anode, while changing the thickness of the cathode GDL simultaneously affects the performance of the anode and cathode due to changes in internal pressure from mechanical compression. This finding was obscured in conventional two-electrode measurements. The work thus guides both high-performance alkaline-membrane water-electrolyzer development and illustrates a useful strategy to study structure–activity relationships in the MEA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗